Laserfiche WebLink
1 <br />ELECTRICAL NOTES: <br />1. ALL WORK SHALL BE DONE IN A NEAT AND WORKMAN LIKE MANNER <br />AND SHALL CONFORM TO THE 2005 NATIONAL ELECTRICAL CODE. <br />2. ALL NEW WORK MAY BE INSPECTED BY THE OWNER. <br />3. UPON COMPLETION OF THE WORK. THE ELECTRICAL CONTRACTOR SHALL <br />DEMONSTRATE THAT THE INSTALLATIONS ARE COMPLETE AND IN <br />PERFECT OPERATING ORDER WITH WIRING FREE FROM GROUNDS OR <br />SHORTS AND WITH EQUIPMENT AND RACEWAYS PROPERLY GROUNDED. <br />4. ALL MATERIAL SHALL BE NEW AND U.L. OR EQUALLY APPROVED. <br />5. THE ELECTRICAL CONTRACTOR SHALL TEST ALL EQUIPMENT AND DEVICES <br />INSTALLED TO THE SATISFACTION OF THE OWNER. RESPONSIBILITY AS TO <br />THE OPERATION OF EQUIPMENT SHALL APPLY ONLY TO THOSE ITEMS <br />FURNISHED BY THE ELECTRICAL CONTRACTOR, BUT THE CONTRACTOR <br />ASSUMES ALL RESPONSIBILITY FOR ACCURATE WIRING AND FOR <br />THE CORRECT CONTROL OF ALL DEVICES. <br />6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR AND TEST <br />INSTRUMENTS REQUIRED FOR TESTING ELECTRICAL WORK. <br />7. PROVIDE NAMEPLATES ON CONTROL DEVICES WHICH SHOW THE <br />EQUIPMENT SERVED, VOLTAGE, PHASE AND CIRCUIT NUMBERS. <br />8. CABLE TO BE THHN/THWN COPPER, 60OV, 1/C, #12 AWG (MINIMUM) FOR <br />POWER, #14 AWG FOR 120V. CONTROL UNLESS OTHERWISE NOTED. <br />9. UNDERGROUND CONDUIT MAY BE SCHEDULE 40 PVC. ALL FEEDERS TO <br />PANELS AND EQUIPMENT SHALL BE IN ELECTRICAL METALLIC TUBING (E.M.T.). <br />10. CONTRACTOR SHALL INSTALL EQUIPMENT GROUNDING SYSTEM <br />CONNECTING NON -CURRENT CARRYING METAL PARTS OF WIRING <br />SYSTEM TO THE GROUND. <br />11. TAG ALL WIRES AT PANEL BOARDS AND JUNCTION BOXES WITH FIBER <br />OR PLASTIC TAGS. <br />12. ALL GROUNDING SHALL BE IN STRICT COMPLIANCE WITH THE LATEST <br />OSHA AND NEC REQUIREMENTS. ALL CONDUIT CONNECTIONS <br />MUST BE TIGHT TO MAINTAIN A GROUND PATH. <br />13. ALL CIRCUITS FOR POWER AND LIGHTING SHALL HAVE GROUND <br />CONDUCTOR FOR EQUIPMENT GROUNDING. <br />14. ELECTRICAL SHALL SUBMIT SHOP DRAWINGS ON ALL <br />FIXTURES AND EQUIPMENT. <br />15. SUBMIT TO THE OWNER, CERTIFICATES OF FINAL INSPECTION AND <br />APPROVAL IN DUPLICATE FROM APPROVED INSPECTION AGENCY <br />UPON COMPLETION OF THE WORK. <br />16. PRIOR TO THE FINAL ACCEPTANCE F THE WORK, SUBMIT A WRITTEN <br />STATEMENT TO THE OWNER GUARANTEEING ALL EQUIPMENT AND <br />SYSTEMS AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR <br />ONE YEAR FROM DATE OF ACCEPTANCE. UPON WRITTEN NOTICE AND <br />AT NO EXPENSE TO THE OWNER, PROMPTLY REPAIR AND/OR REPLACE <br />ALL DEFECTIVE MATERIALS. <br />17. CONTRACT DRAWINGS ARE ESSENTIALLY SCHEMATIC. CONTRACTOR <br />SHALL VERIFY LOCATION AND DETAIL INFORMATION PRIOR TO <br />ROUGHING IN. <br />18. VERIFY ALL CEILING CONSTRUCTION PRIOR TO ROUGHING IN. <br />19. CONTRACTOR SHALL VERIFY EXACT ELECTRICAL CHARACTERISTICS <br />OF ALL EQUIPMENT TO BE WIRED. <br />20. ON LIGHTING AND RECEPTACLE CIRCUITS, CONTRACTOR MAY USE <br />METAL CLAD CABLE TYPE 'MC' WHERE ALLOWED BY APPLICABLE <br />CODES LIVING UNIT WIRING FROM ITS LOCAL PANEL MAY BE TYPE 'NM' <br />SUBJECT TO LOCAL AUTHORITY APPROVAL. <br />21. PROVIDE TELEPHONE JACK AND CONDUIT TO ABOVE CEILING FOR <br />TELEPHONE ROUGH -IN. MINIMUM CONDUIT SIZE TO BE 3/4". <br />22. CONTRACTOR SHALL OBSERVE OSHA SAFETY STANDARDS AND <br />MAINTAIN AREA CLEAN DAILY. <br />23. ALL WALL AND ROOF PENETRATIONS BY THIS CONTRACTOR. <br />OPENINGS SHALL BE FLASHED, COUNTER FLASHED AND SEALED <br />WEATHER TIGHT AND WATER PROOF. <br />24. PROVIDE A COMPLETE AND OPERATING FIRE ALARM AND FIRE <br />DETECTION SYSTEM IN ACCORDANCE WITH THE LATEST BOCA <br />AND/OR NFPA 101 REQUIREMENTS FOR THE SPECIFIC TYPE OF <br />BUILDING AND USE. <br />25. PROVIDE ALL REQUIRED MOTOR STARTING, DISCONNECTING AND <br />CONTROL EQUIPMENT FOR EACH ITEM OF MOTOR OPERATED <br />MECHANICAL SYSTEM EQUIPMENT COMPLETE WITH NECESSARY <br />SHORT CIRCUIT AND OVERLOAD PROTECTION. THE CONTRACTOR <br />SHALL COORDINATE WITH THE MECHANICAL CONTRACTORS FOR <br />SCOPE OF WORK INVOLVED. <br />26. PROVIDE ALL NECESSARY ELECTRICAL WORK FOR EACH ITEM <br />OF ELECTRICALLY OPERATED EQUIPMENT FURNISHED BY THE <br />OWNER OR OTHER CONTRACTS. VERIFY ELECTRICAL <br />CHARACTERISTICS PRIOR TO INSTALLATION. <br />27. ALL SAFETY AND DISCONNECT SWITCHES SHALL BE HEAVY DUTY <br />CONSTRUCTION AND OF VOLTAGE AND AMPERE RATING TO SUIT <br />EACH FUNCTION. <br />28. ALL PANELBOARDS TO BE CIRCUIT BREAKER TYPE OF VOLTAGE <br />CHARACTERISTICS AND AMPACITY RATING TO SUIT EACH <br />APPLICATION. MINIMUM SERIES SHORT CIRCUIT RATING TO BE <br />10,000 AMPERES, RMS, U.L. SYMMETRICAL. ALL BUS BARS ARE <br />TO BE COPPER. ALL CIRCUIT BREAKERS TO BE BOLT -ON. <br />29. FIRE ALARM SYSTEM DESIGN TO BE BY AN APPROVED AND CERTIFIED <br />SYSTEM VENDOR OR CONTRACTOR AND INSTALLED IN ACCORDANCE <br />WITH N.F.P.A. REGULATIONS AND LOCAL FIRE MARSHALL'S OFFICE. <br />30. CONTRACTOR TO SUBMIT SYSTEM DESIGN TO FIRE MARSHALL'S OFFICE <br />FOR APPROVAL UTILIZING THE SYSTEM EQUIPMENT SHOWN AS A GUIDE <br />ONLY. ALL MODIFICATIONS AND/OR ADDITIONS TO THE SYSTEM <br />REQUIRED BY THE FIRE MARSHALL'S OFFICE SHALL BE A PART OF THIS <br />CONTRACT. <br />31. LOCATE ALL SYSTEM DETECTORS TO SUIT LIGHTING FIXTURES, <br />MECHANICAL SYSTEMS EQUIPMENT AND AIR DIFFUSERS. <br />32. ALL SYSTEM WIRING SHALL BE TYPE APPROVED FOR APPLICATION. <br />ALL SYSTEM WIRING NOT CONCEALED IN BUILDING CONSTRUCTION <br />SHALL BE INSTALLED IN SPECIFIED ELECTRICAL RACEWAYS. <br />33. SEE FP DRAWINGS FOR EXTENT OF WORK. <br />34. PROVIDE FIRE STOPPING AT ALL FIRE WALL PENETRATIONS. SEE <br />ARCHITECTURAL DRAWINGS FOR FIRE WALL LOCATIONS. <br />35. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE LOCAL UTILITY <br />COMPANY FOR THE TYPE OF ELECTRIC SERVICE TO SERVE THIS PROJECT <br />INCLUDING THE LOCATION OF ENERGY RECORDING EQUIPMENT. ALL <br />CHARGES BY THE UTILITY COMPANY TO THE OWNER SHALL BE INCLUDED <br />INTO THE ELECTRICAL CONTRACT. ANY AND ALL DISCREPANCIES BETWEEN <br />THE CONTRACT DESIGN AND THE UTILITY COMPANY'S REQUIREMENTS SHALL <br />BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND NECESSARY <br />ADDENDUMS DURING THE PROJECT BIDDING PERIOD. <br />36. ALL APPURTENANCES REQUIRED FOR A COMPLETE AND OPERATING <br />SYSTEM ARE NOT SHOWN. CONTRACTOR TO PROVIDE ALL <br />APPURTENANCES NECESSARY FOR A COMPLETE OPERATING SYSTEM. <br />CONTRACTOR TO CONTACT ARCHITECT/ENGINEER IN WRITING, PRIOR <br />TO BIDDING, FOR CLARIFICATION DISCREPANCIES OR OMISSIONS IN <br />DESIGN DOCUMENTS. <br />ELECTRICAL AB13REVIATIONS: <br />A <br />AMP <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />A/C <br />AIR CONDITIONING <br />AC <br />ALTERNATING CURRENT <br />C/B(CB) <br />CIRCUIT BLEAKER <br />C <br />CONDUIT <br />CU <br />COPPER <br />EC <br />ELECTRICAL CONTRACTOR <br />EMT <br />ELECTRICAL METALLIC TUBING <br />GC <br />GENERAL CONTRACTOR <br />GFI <br />GROUND FAULT INTERRUPTER <br />GND <br />GROUND <br />HOA <br />HANDS OFF AUTO <br />HP <br />HORSEPOWER <br />JB <br />JUNCTION BOX <br />KW <br />KILOWATT <br />KV <br />KILOVOLT <br />KV-A <br />KILOVOLT -AMPERE <br />MCC <br />MOTOR CONTROL CENTER <br />N <br />NEUTRAL <br />NIC <br />NOT IN CONTRACT <br />NTS <br />NOT TO SCALE <br />PB <br />PUSH BUTTON <br />PNL <br />PANEL <br />RCPT <br />RECEPTACLE <br />UON <br />UNLESS OTHERWISE NOTED <br />V <br />VOLT <br />WP <br />WEATHERPROOF <br />XFMR <br />TRANSFORMER <br />2 <br />3 <br />FIRE ALARM AND SMOKE DETECTION SYSTEM NOTES: <br />1. PROVIDE APPROVED EARTH GROUND AT THE FIRE ALARM CONTROL PANEL. <br />CHASSIS OR CONDUIT GROUND IS NOT ACCEPTABLE. <br />2. ALL INSTALLATIONS MUST BE IN ACCORDANCE WITH ARTICLE 760 OF THE <br />NATIONAL ELECTRICAL CODE. FIRE ALARM CABLE MUST BE MARKED TYPE <br />FPL (NON -PLENUM) OR FPLP (PLENUM) AS DETERMINED BY TYPE(S) OF <br />CEILING IN THE BUILDING. <br />3. AUXILIARY ALARM RELAY MUST BE WITHIN 3 FEET OF DEVICE IF IT IS TO <br />CONTROL AS PER NFPA 72, CHAPTER 3.9.2.1 LATEST EDITION. <br />4. NO A.C. CARRYING CONDUCTORS ARE ALLOWED TO SHARE RACEWAYS WITH <br />FIRE ALARM SYSTEM WIRING. <br />S. ALL SMOKE DETECTORS SHALL BE LOCATED 3 OR MORE FEET FROM ANY <br />SUPPLY OR RETURN AIR REGISTER. DETECTORS SHALL BE AT LEAST <br />12 INCHES FROM ANY PART OF ANY LIGHTING FIXTURE. <br />6. 110 VAC CIRCUIT FEEDING THE FIRE ALARM CONTROL PANEL(S) SHALL <br />BE DEDICATED EQUIPPED WITH BREAKER LOCK IN ACCORDANCE WITH <br />NFPA 72 LATEST EDITION. <br />7. THIS SYSTEM SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 72. <br />S. MOUNTING HEIGHTS ARE AS FOLLOWS: <br />• PULL STATION: 48" AFF TO HANDLE <br />• HORN STROBE: V-8" AFF OR 6" BELOW CEILING <br />WHICHEVER IS LOWER <br />- STROBE: 6'-8" AFF OR 6" BELOW CEILING <br />WHICHEVER IS LOWER <br />9. DUST COVERS FURNISHED WITH DETECTORS MUST BE INSTALLED WITH EVERY <br />DETECTOR UNTIL FINAL CHECKOUT. <br />10. ANY CABLE OTHER THAN THAT SPECIFIED ABOVE SHALL BE SUBMITTED TO <br />AND APPROVED IN WRITING PRIOR TO PURCHASE. <br />11. SMOKE AND HEAT DETECTORS SHALL BE MOUNTED ON THE CEILING, UNLESS <br />NOTED OTHERWISE. IT IS NOT PERMISSIBLE TO INSTALL DETECTORS ON THE <br />BOTTOM OF OPEN WEB JOISTS, OR ANY BEAM EXCEEDING 12" IN DEPTH <br />FROM CEILING. SMOKE/NEAT DETECTORS CAN BE MOUNTED ON THE BOTTOM <br />OF A SOLID BEAM IF IT MEASURES 12" OR LESS IN DEPTH, PROVIDED THE <br />CEILING IS LESS THAN 10 FEET AFF. <br />12. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR METERING ALL WIRES <br />TO ENSURE THAT THEY ARE FREE AND CLEAR OF GROUNDS AND THE PROPER <br />END -OF -LINE RESISTANCE IS READ. IF GROUNDS AND SHORTS ARE FOUND <br />ON THE SYSTEM WIRING ALL WIRING SHALL BE CORRECTED. <br />13. PROVIDE FIRE STOPPING AT ALL FIRE WALL PENETRATIONS. SEE <br />ARCHITECTURAL DRAWINGS FOR FIRE WALL LOCATIONS. <br />14. ALL APPURTENANCES REQUIRED FOR A COMPLETE AND OPERATING SYSTEM <br />ARE NOT SHOWN. CONTRACTOR TO PROVIDE ALL APPURTENANCES <br />NECESSARY FOR A COMPLETE OPERATING SYSTEM. CONTRACTOR TO <br />CONTACT ARCHITECT/ENGINEER IN WRITING, PRIOR TO BIDDING, FOR <br />CLARIFICATION OF DISCREPANCIES OR OMISSIONS IN DESIGN DOCUMENTS. <br />ELECTRICAL SYMBOLS: <br />2'x4' FLUORESCENT FIXTURE <br />0 Vx4' FLUORESCENT FIXTURE <br />2'x2' FLUORESCENT FIXTURE <br />EXPOSED STRIP LIGHT <br />® EXIT LIGHT <br />EXIT LIGHT WITH DIRECTIONAL ARROW (1 SIDE) <br />1e, EXIT LIGHT WITH DIRECTIONAL ARROW (2 SIDE) <br />FA LIGHTING FIXTURE ON EMERGENCY CIRCUIT <br />NL <br />EMERGENCY LIGHT/BATTERY <br />0 <br />FLUORESCENT WALL SLOT FIXTURE <br />0 <br />RECESSED LIGHTING FIXTURE <br />1_0 <br />WALL -MOUNTED FIXTURE <br />S SWITCH <br />S3 SWITCH - 3 WAY <br />S4 SWITCH - 4 WAY <br />SD SWITCH - DIMMER <br />SA SINGLE POLE SWITCH CONTROLLING LIGHTING FIXTURE <br />SM MANUAL MOTOR STARTER <br />SO OCCUPANCY SENSOR - WALL MOUNTED <br />ST MANUAL MOTOR STARTER SWITCH <br />OS OCCUPANCY SENSOR - CEILING MOUNTED <br />RECEPTACLE - DUPLEX <br />0 <br />ELECTRICAL DEVICE MOUNTING HEIGHTS: <br />9" BELOW CEILING- CLOCKS, PROGRAM LIGHTS, FIRE ALARM GONGS <br />1 & - BATTERY LIGHT UNITS & REMOTE WALL MOUNTED LIGHT <br />HEADS OR V-0" BELOW CEILING. <br />8%6" - PENDANT HUNG INCANDESCENT & STRIP LIGHT FIXTURES, <br />OR SEE ARCH DWGS. <br />6" BELOW CEILING- TOP OF BACK MOUNTED WALL EXIT FIXTURES (NOT ABOVE DO <br />g ABOVE DOOR - WARNING & SIGNALING FIXTURES/SIGNS <br />V-8" - ILLUMINATED FIRE SIGNALS <br />V-6" - TOP OF FLUSH & SURFACE MOUNTED ELECTRICAL LIGHTING 8 <br />PANELBOARDS & TELEPHONE CABINETS <br />V-O" - TOP OF HIGHEST ELECTRICAL SAFETY DISCONNECT SWITCH, N <br />STARTERS,CONTACTORS <br />- WALL MOUNTED ELECTRICAL DEVICE LIGHTING SWITCHES, MA <br />4%0" MOTOR STARTERS, THERMOSTATS & FIRE ALARM PULL STATII <br />- WALL MOUNTED WIRE MOLD <br />- ELECTRICAL RECEPTACLES WITHIN MECHANICAL SPACES, ELE <br />& ELEVATOR ROOMS <br />V-6" - ELECTRICAL RECEPTACLES <br />- TELEPHONE OUTLETS (NON-PUBLIC) <br />- VOICE DATA OUTLETS <br />NOTES: <br />1. MOUNTING HEIGHTS TO CENTER OF OUTLETS UNLESS NOTED <br />2. + INDICATES SPECIAL MOUNTING HEIGHTS <br />3. AC INDICATES ABOVE COUNTER <br />="FI <br />RECEPTACLE - DUPLEX - GROUND FAULT INTERRUPTER <br />=QNP <br />RECEPTACLE - DUPLEX - WEATHERPROOF <br />RECEPTACLE - DUPLEX - SWITCHED ON ONE SIDE <br />SPECIAL RECEPTACLE -RATING AS NOTED <br />® <br />FLOOR MOUNTED DUPLEX RECEPTACLE <br />�J <br />JUNCTION BOX <br />TELEPHONE OUTLET -WALL MOUNTED <br />q <br />HOUSE TELEPHONE/DATA <br />TELEPHONE VERIZON <br />- <br />PANEL BOARD <br />MOTOR <br />UNFUSED SAFETY SWITCH <br />❑F FIRE ALARM PULL STATION <br />FIRE ALARM AUDIOVISUAL ALARM <br />-6 0- CIRCUIT BREAKER <br />TR TRANSFORMER <br />11. GROUND <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />NL NIGHT LIGHT <br />WP WEATHER PROOF <br />2IL 26 HOME RUN TO PANEL & CIRCUIT NOTED <br />�+ CABLE TELEVISION OUTLET <br />® CARD READER <br />WIRE SIZE CHART <br />(FOR 3% VOLTAGE DROP) <br />BREAKER SIZE <br />0'-50, <br />51'-100, <br />101'-150' <br />151'-200' <br />201'-250' <br />120V <br />20A <br />12 <br />10 <br />8 <br />6 <br />4 <br />30A <br />10 <br />8 <br />6 <br />4 <br />3 <br />40A <br />8 <br />6 <br />4 <br />3 <br />2 <br />50A <br />6 <br />4 <br />3 <br />2 <br />1 <br />NOTE: <br />WIRE SIZES FOR CIRCUITS SHALL BE #12 UNLESS CIRCUIT WIRE <br />LENGTH EXCEEDS 50' (FOR 20A). OTHER SIZES SHALL BE AS SHOWN <br />BY THE CHART ABOVE. <br />5 <br />A <br />SCIBMI`f U11) ,A1N(S) HAVE BEEN R VIEWET� <br />8* 20ftyt+ L nARS S OFFICE <br />i <br />be anted this revie of Phn aftftdis a <br />Devi -to assist theycontra in cow4arm ro <br />*12fic-aWlim, safety codes. This, rem is not inwrded <br />te, k aiaat apprmval of the submit plans.. it is, <br />WdT8ctpr*sek responsibility to ensure that the plans are in <br />WnPlefe;Lopliance with att applicabl&NFPA codes ffid <br />I al or iinarlces, in tt event that fuirther examination,or <br />site, Inspectw-rt reveals areas of norl-compliance, if shalt be <br />the cpntrecWs sple responsibility. at theicsole expense 1 <br />bn%, those areas. it) compliance, The. Cityassumes no) <br />Wwp sibillty .for the. contractor's failure. to, be-ia compii <br />04,4111 applicable NFPA_Godes,and local:ordbarx=. <br />VA <br />A4*WWUWWLYW1THALL <br />A00 MM. FLORIDA BUILDING <br />XPWAL��,EGMC CODE AND <br />0 4MYROW ORDINANCES <br />REVIEW DATE <br />P17'y <br />LAM <br />OF ZE H <br />EN <br />U <br />N <br />z <br />O <br />F-' <br />O <br />� <br />E~ <br />Con <br />U <br />a <br />Cn <br />O <br />a <br />U <br />o <br />O <br />Q <br />0) <br />� <br />Gn <br />Un <br />CA <br />6 <br />N <br />c <br />o <br />0 <br />4-1 <br />a <br />ROBERT MUNROE PE #33868 <br />J <br />Q <br />W <br />rn <br />project no. <br />drawn by: <br />2006-068.00 <br />date: <br />checked by: <br />NOV , 2006 <br />scale: <br />approved by: <br />sheet no. <br />El <br />A mO <br />