My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38130 Pretty Pond Rd (6)
Zephyrhills
>
Building Department
>
Building Plans
>
38130 Pretty Pond Rd (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:19:42 PM
Creation date
1/21/2025 3:31:14 PM
Metadata
Fields
Template:
Building Plans
Street #
38130
Location
Pretty Pond Rd
Contractor
Douglas Company
Building Plans - Permit #
6867
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />11 <br />E <br />F <br />2 <br />CODE INFORMATION <br />SHA # 2006-068.00: Bentley Commons @ ZEPHYRHILLS: 108 Units, 103,810 sq. ft. <br />Applicable Codes <br />Florida Building Codes 2004 w/ Amendments Including: <br />Florida Building Code Florida Fuel Gas Code Florida Accessibility Code <br />Florida Mechanical Code Florida Fire Prevention Code <br />Florida Plumbing Code National Electrical Code 2002 <br />Building to be equipped with fire sprinklers per NFPA 13 <br />Building to be equipped with a fire alarm per 907.2.9 <br />(302.1.1) Incidental Use Areas <br />Areas such as storage rooms in excess of 100 sq It and laundry rooms in excess of 100 sq ft shall be protected by 1 hour rated <br />oonstruction or automatic sprinkler system. <br />(302.3) r <br />(302.3.2) Separated Uses between A and R <br />(303) Assembly Group <br />(303.1) A-2 and A-3 (Non -separated) <br />(310) Residential Group <br />(310.1) R-2 <br />(Table 302.3.2) Required Separation of Occupancies <br />R-2 to A-2 or A-3 =1 hours (with sprinkler reduction per 302.3.2 exception) <br />(404) Atrium <br />(404.4) Smoke Control <br />(404.5) Exception 3, Enclosure Not Required w/ smoke Control <br />(503) General Height & Area Limitations <br />Proposed Allowed (per table 503) With Frontage Increase With Sprinkler Increase <br />Building Height 3 Stories 3 Stories N/A 4 Stories <br />Floor Area: 25,213 s.f. 12,000 s.f. 12,000 x 1.75 = 21,000 s.f. 21,000 x 200% = 42,000 s.f. <br />(602) Construction Classification <br />(602.5) Type SA <br />(Table 601) Fire Resistance Ratings Required For Building Elements (hours) <br />Structural frame including columns, girder, trusses: 1 <br />Bearing walls (exterior): 1 <br />Bearing walls (interior) 1 <br />Non -bearing walls & partitions (exterior): 0 <br />Non -bearing walls & partitions (interior): 0 <br />Floor construction (including support beams & posts): 1 <br />Roof construction (including support beams & posts): 1 <br />Corridors (per table 1016.1): 0 <br />Vertical exit enclosure (per 1019.1): 1 <br />(Table 602) Fire Seraration Distance <br />No exterior wall rating required when fire separation distance is greater than 30'-0". <br />Walls separating dwelling units in the same building shall be 1 <br />fire partitions. (per 708.1): <br />(701) Fire Rated Construction <br />(706) Fire Barriers: See drawings A-1.1 thru A-1.4. Fire Barriers shall comply with requirements of 706. <br />(707.2 & 707.4)Shaft Enclosures: Elevator Shaft walls shall be 1 hour rated construction for buildings less than 4 stories.See Florida <br />Mechanical Code For Grease Ducts. <br />(708) Fire Partitions: See drawings A-1.1 thru A-1.4. Corridor Walls and Unit Separations shall comply with requirements of Section 708. <br />(716) Air Transfer Openings <br />Fire Dampers to be supplied as required per Section 716.5.4. <br />(717) Fireblocking and Draftstopping <br />(717.2) Fireblocking to be installed per Section 717 requirements. <br />(717.3.2) Draftstopping is not required when the building is equipped throughout with an automatic sprinkler system installed in accordance <br />with Section 903.3.1.1, "NFPA 13 Srinkler Systems". <br />(719) Insulating Materials <br />(719.4) Concealed insulation will have a flame spread index of not more than 25 and a smoke developed index of not more than450. <br />(803) Interior Finishes <br />(Table 803.5) Interior Finish Requirements for Walls and Ceilings in a Sprinklered Building. <br />Requirements: Class K. Flame Spread 0-25; smoke developed 0-450. <br />Class B: Flame Spread 26-75; smoke developed 0-450. <br />Class C: Flame Spread 76-200; smoke developed 0-450. <br />Use Group Vertical Exits and Exit Access Rooms and <br />Passageways Corridors Enclosed Spaces <br />A2 Class B Class B Class C <br />A3 Class B Class B Class C <br />R2 Class C Class C Class C <br />(901) Fire Protection Systems <br />Required Provided <br />(903) Automatic Sprinkler Systems Y Y <br />(904) A temative Automatic Sprinkler Systems N N <br />(905) Standpipe System N N <br />(906) Portable Fire Extinguishers Y Y <br />Class K rated extinguisher (Ansul System) provided for commercial cooking equipment. <br />Maximum travel distance not to exceed 76-0". <br />Install per NFPA 10 <br />(907) Manual Fire Alarms N Y <br />(907.2.10) Smoke Alarms Y Y <br />To be interconnected within dwelling units. <br />Duct detectors to be provided where required. <br />(908) Emergency Alarm Systems N N <br />(909) Smoke Control Systems (Atrium Area) Y Y <br />(1003) 2cengd <br />ns of Egress <br />(1003.2) The means of egress shall have a ceiling of not less than 7'-6". <br />(1003.3)cts. Provide minimum headroom of 6'-8" <br />(1009.2)ns of egress stairways shall have a ceiling height of no less than 6'-8' 1 <br />1004d <br />(1004.1.2.) Maximum Floor Area Allowances Per Occupant <br />Occupancy (Assembly) Floor Area (sf) <br />Multipurpose Room 570 sq ft @ 15 sq ft per occupant = 38 ooc <br />Library 350 sq ft @ 50 sq It per occupant = 7 occ <br />Lounge/ Reading Areas 1,888 sq ft @ 50 sq ft per occupant = 38 occ <br />Parlor 517 sq ft @ 50 sq It per occupant = 11 occ <br />Dining Areas (net) 2,250 sq ft @ 15 sq ft per occupant = 150 occ <br />Offices 560 sq ft @ 100 sq ft per occupant = 6 occ <br />Activities Room 400 sq ft @ 15 sq ft per occupant = 27 occ <br />Beauty Shop 252 sq ft @ 30 sq It per occupant = 9 occ <br />Gift Shop 235 sq ft @-3U-sq-iFper occupant = <br />Kitchen 1,019 sq ft @ 200 sq It per occupant = 6 occ <br />Billiards Room 595 sq ft @ 11 sq it per occupant = 55 occ <br />Fitness Center 420 sq ft @ 50 sq ft per occupant = 9 occ <br />Mechanical 589 sq ft @ 300 sq It per occupant = 2 occ <br />Storage 984 sq ft @ 300 sq It per occupant = 4 occ <br />TOTAL 370 occ <br />Occupancy (Residential) Floor Area (sf) <br />TOTAL Residential Occupancy, all (3) floors @ 200 sq ft/ occ = 420 occ <br />TOTAL OCCUPANCY FOR FACILITY 790 occ <br />(1005) Egress Width <br />(Table 1005.1) Egress width per occupants served <br />Stairways: 0.3" per occupant <br />Other egress components: 0.2" per occupant <br />(1009) Stairways & Handrails <br />(1009.1) Stairway width shall not be less than 44' <br />(1009.2) Headroom shall have a minimum clearance of 80" <br />(1009.3) Stair riser height shall be 7" max. and 4" min. Treads to be 11" min. <br />(1009.4) Stairway landings width shall not be less than that of the stairway they serve. Every stairway shall have <br />a minimum dimension measured in the direction of travel equal to the width of the stairway. <br />(1009.6) Vertical rise between landings shall be no greater than 12'vertically. <br />(1009.11) Stairways shall have landings at top and bottom. <br />(1013) Exit Access <br />(1013.2.1) Multiple tenants. Where more than one tenant occupies anyone floor of a building or structure, each <br />tenant space shall be provided with access to the required exits without passing through adjacent tenant spaces. <br />(1013. mon path of egress travel is 100 feet. <br />(1014) Exit and Exit Access Doorways <br />(1014.1) Number of exits required in Group R occupancy with >10 occupant load = 2 <br />Number of exits required in Group A occupancy with >50 occupant load = 2 <br />(1015) Exit Access Travel Distance <br />(1015.1) Exit access travel distance in Group R occupancy with automatic sprinkler system = 325' <br />Ezit access travel distance in Group A occupancy with automatic sprinkler system = 200' <br />- � � Ai <br />(1016.2) Corridor width shall be 44" minimum <br />(1101) Accessibility <br />All public areas to provide accessible features per the requirements set forth in the Florida Building Code, Chapter 11. <br />(2902) Minimum Plumbing Facilities <br />Quantities per floor: <br />Use Group Water Closets Lavatories Bath Drinking Fountain Other <br />male female <br />A-2 1 per 75 1 per 75 1 per 200 1 per 500 <br />A-3 1 per 125 1 per 65 1 per 200 1 per 500 <br />R-2 1 per unit 1 per unit 1 per unit 1 kitchen sink per unit <br />1 clothes washer connection per 20 dwelling units (6 connections total) <br />LIFE SAFETY SYMBOLS LEGEND <br />NON FIRE RATED WALL ASSEMBLY <br />- - - - - - - - - - 1 HOUR FIRE RATED PARTITON: RATED CONSTRUCTION TO EXTEND TO UNDERSIDE OF RATED FLOOR OR <br />ROOF CEILING ASSEMBLY (FLORIDA BUILDING CODE, SECTION 708). <br />- - 1 HOUR FIRE RATED BARRIER: RATED CONSTRUCTION TO EXTEND TO UNDERSIDE OF FLOOR OR ROOF <br />DECK ABOVE (FLORIDA BUILDING CODE, SECTION 706. <br />36 DO SIZE OR STAIR WIDTH <br />.20 EGRESS WIDTH UNIT (FLORIDA BUILDING CODE, TABLE 1005.1) <br />180 MAXIMUM ALLOWABLE LOAD <br />123 ACTUALLOAD <br />17- DOOR OR STAIR LOAD CHART <br />_41111111111111- EXIT DISCHARGE <br />88 NUMBER = OCCUPANT LOAD <br />ARROW = DIRECTION OF TRAVEL <br />EMERGENCY LIGHTING BATTERY UNIT <br />-NUMBER OF HEADS AS INDICATED- SEE ELECTRICAL PLANS <br />I EMERGENCY LIGHTING REMOTE HEAD- SEE ELCTRICAL PLANS <br />®� = SIGN - ARROWS INDICATEMECTION OF EXIT <br />SEE ELECTRICAL PLANS <br />FACP FIRE ALARM - CONTROL PANEL: INSTALL PER 907.2.9 <br />FAAP FIRE ALARM ANNUNCIATOR PANEL: INSTALL PER 907.2.9 <br />FIRE ALARM - MANUAL FIRE ALARM PULL STATION <br />SEE ELECTRICAL PLANS <br />FE FIRE EXTINGUISHER: INSTALL PER NFPA-10. <br />GC TO COORDINATE LOCATIONS WITH LOCAL FIRE MARSHAL. <br />WALL MOUNTED EXIT SIGN- FLOOR PROXIMITY EXIT SIGNS <br />ARE TO BE WITHIN 6"-8" OF FLOOR: SEE ELECTRICAL PLANS <br />OS SMOKE DETECTOR- SEE ELECTRICAL PLANS <br />3 <br />I <br />5 <br />SQUARE FOOTAGE RESIDENTIAL: 19,047 SE <br />SQUARE FOOTAGE ASSEMBLY: (see <br />Dining Areas: <br />Bistro: <br />Multipurpose Room: <br />Library: <br />Parlor: <br />Activities Room: <br />Beauty Salon: <br />Gift Shop: <br />Kitchen: <br />Offices: <br />Laundry: <br />Reading Lounge Areas: <br />Mechanical Room: <br />/ 200 SE <br />occ. load chart) <br />136 <br />OCC. <br />23 <br />OCC. <br />33 <br />OCC. <br />7 <br />OCC. <br />10 <br />OCC. <br />24 <br />OCC. <br />3 <br />OCC. <br />8 <br />OCC. <br />7 <br />OCC. <br />7 <br />OCC. <br />2 <br />OCC. <br />13 <br />OCC. <br />3 <br />OCC. <br />FIRST FLOOR TOTAL OCCUPANT LOAD: <br />I <br />96 OCCUPANTS <br />276 OCCUPANTS <br />372 OCCUPANTS <br />7 <br />04 <br />FIRST FLOOR <br />IFE SAFETY PLAN �.9, <br />SCALE: 3/32"=1'-0" <br />v <br />(n <br />Z <br />O_ <br />(n <br />w <br />w <br />H <br />rWi� <br />O <br />E� <br />F� <br />p <br />O <br />U <br />o <br />O <br />O <br />w <br />w <br />� <br />U <br />Q <br />rA <br />Q <br />r�1 <br />Cn <br />o <br />N <br />O° <br />all <br />N <br />^" <br />project no. <br />drawn by: <br />2006-068.00 <br />MCL <br />checked by: <br />2006 <br />c ) <br />approved by: <br />s et o. <br />ti <br />tie <br />NL <br />� N <br />0 N <br />-O 0 <br />C "- <br />O U <br />N <br />L <br />C C <br />0 0 <br />@U <br />L <br />N N <br />7 C <br />0 <br />U) C <br />0) 0) <br />C E <br />c3o -° <br />C U <br />C to <br />0 <br />0) 0 <br />U <br />C <br />f6 � <br />O- U <br />.00 � <br />N <br />D > <br />0) C <br />r <br />0) 03 <br />a) 0 <br />O) <br />4-, C <br />Q � <br />0) <br />C <br />m 0 <br />� to <br />C <br />0) .N <br />�_ <br />r- <br />0) <br />N _ <br />0) � <br />� C <br />E <br />co <br />.0 J .0 <br />O- <br />00 (1) Z <br />�Q a <br />C <br />(L0a) <br />O)M U <br />0 Q O <br />_W <br />UQ� <br />J= � <br />vi IJi LU IL <br />�_2 4 <br />Q Q c>S <br />L <br />O � O <br />[n O U <br />Q 0 <br />a N <br />Y •N <br />E <br />Q U <br />LL L <br />Q 0 U) <br />n0� <br />o °)E <br />o4,(n <br />N +� ' <br />O0o <br />�30 <br />Cl t to <br />U CLQ <br />
The URL can be used to link to this page
Your browser does not support the video tag.