In <br />I <br />4 <br />i <br />ABBREVIATIONS <br />A <br />AMPERES <br />AFF <br />ABOVE FINISHED FLOOR <br />AHU <br />AIR HANDLING UNIT <br />BHP <br />BRAKE HORSEPOWER <br />BTUH <br />BRITISH THERMAL UNIT PER HOUR <br />CFM <br />CUBIC FEET PER MINUTE <br />CLG <br />CEILING <br />CD <br />CONDENSATE DRAIN <br />CU <br />CONDENSING UNIT <br />DB <br />DRY BULB <br />DN <br />DOWN <br />DX <br />DIRECT EXPANSION <br />EA <br />EXHAUST AIR <br />EAT <br />ENTERING AIR TEMPERATURE <br />EF <br />EXHAUST FAN <br />EL <br />ELEVATION <br />EXH <br />EXHAUST <br />EQUIP <br />EQUIPMENT <br />ESP <br />EXTERNAL STATIC PRESSURE <br />FB <br />FILTER BOX <br />FD <br />FIRE DAMPER <br />FLEX <br />FLEXIBLE <br />FLR OR FL <br />FLOOR <br />FPI <br />FINS PER INCH <br />FPM <br />FEET PER MINUTE <br />GALV <br />GALVANIZED <br />HP <br />HEAT PUMP or HORSEPOWER <br />KW <br />KILOWATT <br />LEIS <br />POUNDS <br />MAX <br />MAXIMUM <br />MBH <br />THOUSAND BTU/H <br />MIN <br />MINIMUM <br />OA <br />OUTSIDE AIR <br />RA <br />RETURN AIR AND/OR ROOM AIR <br />RTU <br />ROOFTOP UNIT <br />SA <br />SUPPLY AIR <br />TEMP <br />TEMPERATURE <br />TYP <br />TYPICAL <br />UC <br />UNDERCUT <br />VD <br />MANUAL VOLUME DAMPER <br />V <br />VOLTS <br />WB <br />WET BULB <br />0 <br />ROUND <br />OBD <br />OPPOSED BLADE DAMPER <br />SO FT <br />SQUARE FEET <br />TAD <br />TRANSFER AIR DUCT <br />TAG <br />TRANSFER AIR GRILLE <br />NOT ALL ABBREVIATIONS MAY BE USED <br />GENERAL SYMBOLS <br />PLAN OR DETAIL NO.. <br />SHEET NUMBER <br />O <br />KEYED NOTE TO PLAN <br />QREVISION <br />NUMBER <br />NORTH ARROW <br />MECHANICAL SYMBOLS LEGEND <br />® <br />CEILING SUPPLY DIFFUSER <br />CEILING RETURN GRILLE <br />® <br />CEILING EXHAUST GRILLE <br />CEILING MOUNTED CENTRIFUGAL EXHAUST FAN <br />ED <br />IN -LINE MOUNTED CENTRIFUGAL FAN <br />WALL <br />DUCT <br />i_p` r <br />DYNAMIC FIRE DAMPER <br />STYLE 'B' FIRE DAMPER <br />STYLE 'CR' FIRE DAMPER FOR ROUND DUCTS <br />ALL <br />DUC <br />DYNAMIC SMOKE DAMPER <br />ALL <br />DUCT <br />COMBINATION DYNAMIC FIRE/SMOKE DAMPER <br />SD <br />DUCT SMOKE DETECTOR <br />RETURN/EXHAUST DUCT TURNING DOWN <br />RETURN/EXHAUST DUCT TURNING UP <br />Xi <br />SUPPLY DUCT TURNING DOWN <br />SUPPLY DUCT TURNING UP <br />EXISTING DUCT <br />TRANSFER OPENING IN WALL <br />LIC <br />3/4" UNDERCUT BELOW DOOR <br />RADIANT DAMPER (RD) <br />CONNECT TO EXISTING <br />E- <br />SIDE WALL SUPPLY GRILLE <br />-4---- <br />II <br />SIDE WALL RETURN GRILLE <br />OTHERMOSTAT <br />R <br />REFRIGERANT PIPING (LINE SET) <br />C <br />CONDENSATE DRAIN PIPING <br />!0 <br />PIPE TURNING UP <br />PIPE TURNING DOWN <br />a <br />2 POSITION MOTORIZED DAMPER <br />MANUAL VOLUME DAMPER <br />NOT ALL SYMBOLS MAY BE USED <br />GENERAL NOTES <br />1. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS USED <br />CERTAIN ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE <br />MEANING OF WHICH ARE ILLUSTRATED AND EXPLAINED WITHIN THE <br />LEGEND. <br />2. PLANS ARE DIAGRAMMATIC ONLY. THEY ARE INTENDED TO INDICATE <br />CAPACITY, SIZE, LOCATION, DIRECTION, AND GENERAL <br />ARRANGEMENT, BUT NOT EXACT DETAILS OF CONSTRUCTION. THE <br />FACT THAT ONLY CERTAIN FEATURES OF THE INSTALLATION ARE <br />INDICATED MUST NOT BE TAKEN TO MEAN THAT OTHER FEATURES <br />WILL NOT BE REQUIRED. <br />3. COORDINATE WITH THE OTHER TRADES TO INSURE THAT EACH <br />TRADE SHALL HAVE SUFFICIENT SPACE TO INSTALL THEIR <br />EQUIPMENT (DUCTWORK, PIPING, ELECTRICAL WORK, ETC.) <br />4. IN GENERAL, ALL PIPING AND DUCTWORK SHALL BE RUN IN THE <br />CEILING SPACE UNLESS NOTED OR INDICATED OTHERWISE. <br />5. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS AND FIELD <br />DIMENSIONS. <br />6. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE <br />DIMENSIONS. <br />7. ALL RISES AND DROPS IN PIPING AND DUCTWORK MAY NOT <br />NECESSARILY HAVE BEEN SHOWN. CONTRACTOR TO VERIFY. <br />8. PROVIDE ALL STRUCTURAL MEMBERS, SUPPORT BRACKETS, <br />FLASHING, HARDWARE, ETC. REQUIRED TO INSTALL A COMPLETE <br />SYSTEM. <br />9. MOUNT ALL THERMOSTATS 4 FEET ABOVE FINISHED FLOOR, <br />UNLESS OTHERWISE NOTED. <br />MECHANICAL SPECIFICATIONS <br />1. <br />SCOPE OF WORK SHALL INCLUDE ALL MATERIALS, EQUIPMENT <br />12. <br />PROVIDE ACCESS DOORS AS NECESSARY FOR ACCESS TO <br />20. <br />CONTRACTOR SHALL OBTAIN SERVICES OF A TEST AND <br />AND LABOR NECESSARY FOR A COMPLETE AND PROPERLY <br />CONCEALED VALVES, CLEANOUTS, UNIONS, EXPANSION JOINTS, <br />BALANCE AGENCY TO TEST AND BALANCE ALL AIR AND <br />FUNCTIONING INSTALLATION IN ACCORDANCE WITH LOCAL AND <br />DAMPERS, COILS, JUNCTION BOXES, ETC., WHERE NO OTHER <br />HYDRONIC SYSTEMS. TESTING AND BALANCING SHALL BE <br />STATE CODES, AND CONTRACT DRAWINGS AND SPECIFICATIONS. <br />MEANS OF ACCESS IS SHOWN OR SPECIFIED. <br />PERFORMED IN COMPLETE ACCORDANCE WIT THE LATEST <br />EDITION OF THE AABC STANDARDS OR LATEST EDITION OF <br />2. <br />CONTRACTOR SHALL VISIT THE SITE AND OBSERVE ALL EXISTING <br />13. <br />CONTRACTOR SHALL SET IN; POSITION ALL SLEEVES AND <br />NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND <br />LOCAL CONDITIONS WHICH WOULD AFFECT WORK UNDER THIS <br />INSERTS REQUIRED IN WALLS, PARTITIONS, CEILINGS, OR <br />BALANCING. CONTRACTOR SHALL SUBMIT ANAL TAB REPORT AS <br />CONTRACT. CONTRACTOR SHALL EXAMINE ALL PLANS AND <br />FLOORS. CONTRACTOR SHALL DO ALL CUTTING AND PATCHING <br />PART OF 0&M MANUAL. <br />SPECIFICATIONS FOR THIS PROJECT AND CONSULT THEM FOR <br />OF EXISTING AND/OR NEW BUILDING MATERIALS REQUIRED FOR <br />INSTRUCTIONS PERTAINING TO WORK OF THIS SECTION. <br />INSTALLATION OF WORK HEREIN SPECIFIED. <br />21. <br />LOW PRESSURE DUCTWORK SHALL BE CONSTRUCTED OF <br />GALVANIZED SHEET STEEL AND SHALL CONFORM TO THE <br />3. <br />CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND <br />14. <br />CONTRACTOR SHALL AT ALL TIMES KEEP PREMISES FREE FROM <br />LATEST EDITION OF THE SMACNA "HVAC DUCT CONSTRUCTION <br />INSPECTIONS REQUIRED PERTAINING TO WORK UNDER THIS <br />ACCUMULATIONS OF WASTE . MATERIAL. OR RUBBISH GENERATED <br />STANDARDS". <br />CONTRACT AND PAY ALL CHARGES INCIDENTAL THERETO. <br />BY WORK UNDER THIS CONTRACT. CONTRACTOR SHALL LEAVE <br />THE PREMISES IN A CLEAN, ORDERLY AND ACCEPTABLE <br />22. <br />FLEXIBLE DUCT SHALL CONSIST OF A ZINC COATED SPRING <br />4. <br />FURNISH AND INSTALL MECHANICAL SYSTEMS TO MEET ALL <br />CONDITION. <br />STEEL HELIX PERMANENTLY BONDED TO A FULL INTERIOR LINER. <br />CURRENT REQUIREMENTS OF NATIONAL, STATE AND MUNICIPAL <br />DUCT SHALL HAVE A MINIMUM R-VALUE OF 6.0. <br />CODES, RULES REGULATIONS, LAWS AND STANDARDS AS THEY <br />15. <br />ALL EXCAVATION, BACKFILLING, COMPACTION, TESTING, ETC. <br />ARE ADOPTED BY THE GOVERNING AGENCY AND AS THEY MAY <br />REQUIRED FOR THE INSTALLATION OF UNDERGROUND PIPING <br />23. <br />PROVIDE ALL NECESSARY DUCT SYSTEM ACCESSORIES TO <br />APPLY. <br />SHALL BE DONE BY THE MECHANICAL CONTRACTOR. <br />ASSURE PROPER BALANCE, QUIET AND DRAFTLESS DISTRIBUTION <br />AND CONVEYANCE, AND MINIMIZATION OF TURBULENCE, NOISE <br />5. <br />SUBMIT FOR REVIEW, BEFORE COMMENCING WORK, SHOP <br />16. <br />UPON COMPLETION OF WORK, CONTRACTOR SHALL CLEAN, OIL <br />AND PRESSURE DROP FOR ALL SUPPLY, RETURN, EXHAUST AND <br />DRAWINGS FOR ALL MATERIALS AND EQUIPMENT TO BE PROVIDED <br />AND GREASE ALL FANS, MOTORS AND OTHER RUNNING <br />VENTILATION AIR QUANTITIES INDICATED. <br />UNDER THIS CONTRACT. <br />EQUIPMENT AND APPARATUS WHICH HE INSTALLS AND MAKE <br />CERTAIN ALL SUCH APPARATUS AND MECHANISMS ARE IN <br />24. <br />PROVIDE UL LABELED DYNAMIC FIRE DAMPERS IN ALL FIRE <br />6. <br />ANY DEVIATIONS BETWEEN THE CONTRACT DOCUMENTS AND THE <br />PROPER WORKING ORDER. <br />WALL PENETRATIONS. DAMPERS SHALL HAVE RATING TO MATCH <br />FURNISHED EQUIPMENT MUST BE SEPARATELY ACKNOWLEDGED <br />WALL, <br />AND ADDITIONALLY NOTED ON THE SUBMITTAL. SUCH <br />17. <br />AT THE TIME OF SUBSTANTIAL COMPLETION OF WORK, <br />DEVIATIONS AND ALL NECESSARY ADJUSTMENTS ARE THE <br />CONTRACTOR SHALL FURNISH FOUR (4) COMPLETE PORTFOLIOS <br />25. <br />PROVIDE DUCT ACCESS DOORS FOR EACH MANUAL AND <br />RESPONSIBILITY OF THE CONTRACTOR. <br />CONTAINING SHOP DRAWINGS AND OPERATION AND <br />MOTORIZED DAMPER; FIRE DAMPER; ELECTRIC DUCT HEATER; <br />MAINTENANCE INSTRUCTIONS ON ALL EQUIPMENT FURNISHED <br />AND WHERE ACCESS IS OTHERWISE NECESSARY <br />7. <br />MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN A NEAT <br />UNDER THIS CONTRACT. CONTRACTOR SHALL PROVIDE A <br />AND FIRST CLASS WORKMANLIKE MANNER CONSISTENT WITH <br />MINIMUM OF 2-HOURS OF INSTRUCTIONS TO THE OWNER'S <br />CURRENT INDUSTRY METHODS AND STANDARDS. <br />PERSONNEL ON SYSTEM OPERATION, CHANGEOVER AND ROUTINE <br />MAINTENANCE REQUIREMENTS. <br />8. <br />CONTRACTOR SHALL FURNISH, INSTALL AND CONNECT WITH <br />APPROPRIATE SERVICES ALL ITEMS SHOWN ON ANY DRAWINGS <br />18. <br />THE CONTRACTOR SHALL MAINTAIN A SET OF DRAWINGS AT <br />WITHOUT ADDITIONAL EXPENSE TO OWNER. <br />THE SITE AND EACH DAY SHALL RECORD INSTALLATION OF <br />9. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER PROTECTIVE <br />PIPE, DUCTS, ETC. TO INSURE ACCURATE "AS -BUILT" <br />MEASURES WHEN WORKING OVERHEAD OR IN FINISHED AREAS. <br />DRAWINGS. CONTRACTOR SHALL PROVIDE OWNER TWO (2) SETS <br />HE SHALL REPAIR, REPLACE OR TOUCH-UP ALL FINISHED <br />OF AS -BUILT DRAWINGS AT COMPLETION OF PROJECT. <br />SURFACES WHICH MAY BE DAMAGED AS A RESULT OF HIS <br />19. <br />THE MECHANICAL CONTRACTOR SHALL GUARANTEE EQUIPMENT <br />OPERATIONS. <br />AND INSTALLATION FOR A PERIOD OF ONE YEAR FROM FINAL <br />10. <br />ALL MATERIALS SHALL BE PROTECTED FROM THE WEATHER, <br />ACCEPTANCE. CONTRACTOR SHALL PROVIDE NECESSARY <br />DAMAGE, MOISTURE, DIRT, DEBRIS, ETC. DO NOT INSTALL <br />ADJUSTMENTS AND/OR REPLACEMENTS OF ALL DEFECTIVE <br />DAMAGED EQUIPMENT. <br />EQUIPMENT, MATERIALS AND WORKMANSHIP WITHOUT EXPENSE <br />TO THE OWNER. <br />11. <br />PROVIDE ESCUTCHEONS, FABRICATED PLATES OR COLLARS AT <br />EACH LOCATION WHERE PIPE OR DUCT PASSES THROUGH A <br />FINISHED SURFACE. <br />EXHAUST FAN SCHEDULE <br />DESIGNATION <br />EF-1 <br />LOCATION <br />QUANTITY <br />BATHROOMS <br />5 <br />TYPE <br />CABINET <br />- _ _ _ <br />AIRFLOW (CFM) <br />93 <br />DRIVE TYPE <br />EXT. STATIC (in. wg.) <br />DIRECT <br />0.250 <br />FAN SPEED (RPM) <br />640 <br />MOTOR HORSEPOWER <br />77 WATTS <br />VOLTAGE/PHASE <br />REMARKS <br />120/1 <br />1, 2, 3, 4 <br />CONTROL TYPE <br />WALL SWITCH <br />MANUFACTURER <br />CARNES <br />MODEL NO. <br />VCDD 010C <br />_ <br />REMARKS: <br />1. INTEGRAL BACKDRAFT DAMPER <br />2. INTEGRAL DISCONNECT SWITCH <br />3. PROVIDE WITH RADIATION DAMPER <br />4. PROVIDE WITH WALL CAP; MATCH EXISTING <br />DX SPLIT SYSTEM HEAT PUMP SCHEDULE <br />AHU-120A / HP-120A <br />ALL OTHER NEW <br />UNITS <br />& <br />AHU-120B / HP-120B <br />AHU's & HP's <br />LOCATIONS <br />DAY ROOM <br />ALL STUDIO & MEMORY UNITS <br />QUANTITY OF SPLIT SYSTEMS <br />2_ <br />MANUFACTURER <br />DAI KI N <br />_35 <br />DAIKI N <br />MODEL NUMBER (INDOOR UNIT) <br />FCQ18PAVJU <br />FDXS09LVJU <br />MODEL NUMBER (OUTDOOR UNIT) <br />RZQ18PVJU9 <br />RXS09LVJU <br />INDOOR UNIT TYPE / INSTALLATION <br />CASSETTE / ABOVE CEILING <br />CONCEALED / ABOVE CEILING <br />REFRIGERANT <br />R-410A <br />R-410A <br />SEER <br />17.2 <br />15.1 <br />COOLING CAPACITY (BTUH) <br />18,000 <br />8,500 <br />SENSIBLE CAPACITY (BTUH) <br />14,100 <br />7,130 <br />HEATING CAPACITY (BTUH) <br />20,000 <br />10,000 <br />AIRFLOW (CFM - WET) <br />560 <br />280 <br />INDOOR VOLTAGE/PHASE <br />208/1 <br />208/1 <br />INDOOR UNIT MCA/MOCP <br />0.4 / 15 <br />N/A <br />OUTDOOR VOLTAGE/PHASE <br />208/1 <br />208/1 <br />OUTDOOR UNIT MCA/MOCP <br />16.5120 <br />8 / 15 <br />REMARKS <br />1, 2, 3, 4 <br />1, 2, 3, 4 <br />REMARKS: <br />1. ELECTRICAL TO PROVIDE DISCONNECT SWITCH FOR INDOOR AND OUTDOOR UNIT. <br />2. PROVIDE WALL MOUNTED THERMOSTAT SIMILAR TO EXISTING THERMOSTATS. <br />3. PROVIDE WITH CONDENSATE DRAIN PUMP. <br />4. SIZE AND ROUTE REFRIGERANT LINES PER MANUFACTURER INSTRUCTIONS. <br />. cVEIGH & MANGUM <br />ENGINEERING•INC <br />340 Interstate North Parkway, Suite 360 <br />,Atlanta - Georgia 30339 <br />Ph: (078) 213-1616 Fax: (678) 213-1617 <br />email: majl@McVeighMangum.com <br />of Record: Farshid Yarizadeh License No.: 40287 <br />FOUSE <br />ARCHITECTURE <br />& INTERIORS, P.C. <br />3201 S. Cherokee Lane Suite 340 <br />Woodstock, Georgia 30188 <br />Voice 678-391-5365 <br />Fax 678-391-5362 <br />email: rlf@fousearchitecture.com <br />0 Copyright 2011 Fouse Architecture & Interiors, P.C. <br />Seal: <br />% <br />AL E0 <br />Consultants: CIVIL ENGINEER: <br />STRUCTURAL ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Chad McDonald, P.E. <br />678.213.1616 <br />MEP ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Tony G. Fernandez, P.E. <br />.678.213.1616 <br />Sheet Information: <br />Job Number 11002 <br />Original Issue Date 08-31-2012 <br />Issue Dates: <br />No. I ISSUE I DATE <br />PERMIT/CONSTRUCTION 1 08-31-2012 <br />Sheet Title: <br />MECHANICAL. <br />LEGEND, <br />SCHEDULES <br />AND SPECS <br />Sheet: <br />M-001 <br />FOR CONSTRUCTION <br />P4a <br />®C77H <br />