My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38130 Pretty Pond Rd (8)
Zephyrhills
>
Building Department
>
Building Plans
>
38130 Pretty Pond Rd (8)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:39:38 PM
Creation date
1/21/2025 3:33:36 PM
Metadata
Fields
Template:
Building Plans
Street #
38130
Location
Pretty Pond Rd
Contractor
Williams Company Tampa
Building Plans - Permit #
13654
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V, <br />A <br />N <br />0 <br />d <br />FIRE ALARM HORN OR <br />STROBE LIGHT PAINT <br />TO MATCH WALL <br />ALIGN WHEN MOUNTED <br />ON SAME WALL <br />LIGHT SWITCH OR DIMMER <br />FIRE ALARM PULL <br />STATION <br />w RECEPTACLE <br />U <br />z <br />cn —� <br />TELEPHONE OR <br />DATA JACK <br />(TYPJ <br />SCALE: NONE <br />00 W <br />z <br />❑ 6 INCHES <br />CEILING <br />ALIGN HORN ONLY DEVICE WITH TOP OF DOOR FRAME <br />STROBE OR HORN/STROBE DEVICE 80" AFF TO STROBE <br />WALL MOUNTED <br />TELEPHONE <br />RECEPTACLE <br />m <br />TOP OF <br />COUNTER <br />BACKSPLASH <br />FLOOR <br />MOUNTING HEIGHTS OF DEVICES <br />r SERVICE <br />ENTRANCE <br />QUIP. <br />GROUND BUS <br />NEUTRAL BUS <br />ROUNDING ELECTRODE CONDUCTOR <br />NS INDICATED ON POWER RISER DIAGRAM <br />.SIZE PER 2002 NEC TABLE 250-66, MIP <br />GROUND CLAMP ON <br />METALLIC WATER MAI <br />3/4" 0 X 10'-0" CU <br />GROUND ROD DRIVEN <br />TO f3" BELOW FINISH <br />GRADE----\ <br />#6 CU., MINIMUM <br />(TYP) G R 0 <br />SCALE: NONE <br />1/2" CONDUIT TO <br />ABOVE CEILING WITH RG6 <br />CABLE TO CAN CABINET, <br />COORD. WITH OWNER <br />CAN COAX <br />CONNECTOR <br />EXOTHERMIC WELD <br />TO BLDG STEEL <br />(WHERE AVAILABLE) <br />#4 CU, MINIMUM <br />a CONC. FOUNDATION <br />-- OR FOOTING IN DIRECT <br />CONTACT WITH EARTH <br />20' OF 1 /2" GAL. STEEL ROD <br />2" MIN. CONCRETE COVER <br />PROVIDE SHORT PVC SLEEVE OR OTHER <br />DESIGNATION ACCEPTABLE TO THE LOCAL <br />INSPECTOR TO IDENTIFY ROD AS PROPERLY <br />INSTALLED, BONDED <br />UNDING DETAIL. <br />(TYP) G R 0 U <br />SCALE: NONE <br />DUCT TYPE SMOKE <br />DETECTORS FOR <br />RTU'S AS REQUIRED <br />PER CODE TYPICAL <br />PROVIDE SMOKE <br />DETECTOR ABOVE <br />FIRE ALARM CONTROL <br />PANEL <br />P D S S 75cd <br />(tYP) <br />BY EACH EXIT DOOR <br />AS REQUIRED. (TYP) <br />FAAP FACP <br />FIRE ALARM 120V POWER 3/4% TO 'TTB' <br />ANNUNCIATOR PANEL <br />RE ALARM CONTROL PANEL <br />FIRE ALARM SYSTEM NOTES: <br />1. FIRE ALARM DEVICES ARE TO BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND ADA. <br />2. ACTUATION OF ANY PULL STATION, FLOW SWITCH OR SMOKE DETECTOR SHALL ACTIVATE ALARM. <br />3. FIRE ALARM SYSTEM SHALL BE ADDRESSABLE, 24VDC, POWER LIMITED, FULLY SUPERVISED, WITH 60 <br />HOUR STANDBY BATTERY SYSTEM. <br />4. NOTE THAT FIRE ALARM PLANS SUBMITTED HEREIN FOR BUILDING PERMIT ARE NOT PART OF THE <br />BUILDING PLANS REVIEW. A SEPARATE SUBMITTAL AND PERMIT IS REQUIRED FOR THE FIRE ALARM <br />AND/OR FIRE SPRINKLER SYSTEM. <br />5. ALL FIRE ALARM SWITCHES, MODULES, AND WIRING SHALL BE PROVIDED BY THE FIRE ALARM <br />SUB —CONTRACTOR. FIRE ALARM SYSTEM SUB —CONTRACTOR SHALL BE RESPONSIBLE TO SUBMIT <br />120V AC POWER —SUPPLY DETAILED SYSTEM DRAWINGS, CUTSHEETS, WIRING DIAGRAMS, ETC. AS REQUIRED FOR FINAL PERMITTING. <br />FOR RECEPTACLE WITH 6. ALL COMPONENTS NECESSARY FOR CERTIFICATE OF OCCUPANCY SHALL BE INCLUDED IN THE BID. SEE <br />METAL BARRIER IN BOX PLANS FOR MINIMUM NUMBER OF DEVICES. ALLOW FOR THREE MORE SMOKE DETECTORS, FIRE ALARM <br />HORN/STROBES, AND PULL STATIONS EACH AND PROVIDE ADDITIONAL DEVICES WHERE DIRECTED BY FIRE <br />MARSHALL. <br />DUPLEX RECEPTACLE <br />7. ALL TAMPER AND FLOW SWITCH CONNECTION LOCATIONS TO BE FIELD VERIFIED WITH SPRINKLER <br />2 GANG PLATE SUB —CONTRACTOR AS REQ'D. <br />8. COORD. WITH M.C. TO PROVIDE SHUTDOWN INTERLOCK WIRING TO RESPECTIVE AHU AS REQUIRED. <br />BOX DIVIDER 9. PROVIDE DUCT DETECTOR INDICATING PLATE ON CEILING GRID UNDER EACH RESPECTIVE DUCT DETECTOR <br />LOCATION. ADDRESSABLE PANEL DISPLAY TO NOTE ROOM NUMBER FOR ALL DEVICES. <br />t***0-4� FIRE ALARM RISER DIAGRAM- <br />NDING DETAIL <br />NOT TO SCALE <br />_ cVEIGH & MANGUM <br />ENGINEERING•INC <br />340 Interstate North Parkway, Suite 360 <br />Atlanta - Georgia 30339 <br />Ph: (678)213-1616 Fax: (678)213-1617 <br />email: mail(aJMcVeighMangum.com <br />of Record: Tony G. Fernandez License No.: 60754 <br />FOUSE <br />ARCHITECTURE <br />& INTERIORS, P.C. <br />3201 S. Cherokee Lane Suite 340 <br />Woodstock, Georgia 30188 <br />Voice 678-391-5365 <br />Fax 678-391-5362 <br />email: rlf@fousearchitecture.com <br />O Copyright 2011 Fouse Architecture & Interiors, P.C. <br />Seal: <br />Consultants: CIVIL ENGINEER: <br />STRUCTURAL ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Chad McDonald, P.E. <br />678,213.1616 <br />MEP ENGINEER: <br />McVeigh & Mangum Engineering Inc <br />340 N Interstate Parkway, Suite 360 <br />Atlanta, GA 30339 <br />Contact: Tony G. Fernandez, P.E. <br />678.213.1616 <br />Job Title: <br />C <br />ayAy <br />C a a° <br />rw <br />�a <br />w Jd <br />Q AN <br />Sheet Information: <br />Job Number 11002 <br />Original Issue Date 08-31-2012 <br />Issue Dates: <br />No. IISSUE I DATE <br />PERMIT/CONSTRUCTION 08-31-2012 <br />Sheet Title: <br />ELECTRICAL <br />SCHEDULES AND <br />DETAILS <br />Sheet: <br />E-002 <br />FOR CONSTRUCTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.