GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORIDA BUILDING CODE <br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE - RESIDENTIAL 6TH EDITION, <br />T.L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING <br />COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />SLAB: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P,S,F, <br />ROOF! <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S,F, <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S,F, <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F, <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P,S,F, <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2011 FLORIDA <br />BUILDING CODE, RESIDENTIAL 6TH EDITION- SECTION R301,2.1,1. AND 2011 FLORIDA BUILDING CODE <br />6TH EDITION SECTION 1609 <br />COMPONENT t CLADDING WIND LOADS <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - 11 <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 1 EXPOSURE ADJUSTMENT <br />COEFFICIENT • I,O <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602,5 <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32,3/-35.3 <br />2 <br />3 <br />-11016 <br />+32,3/-89,0 <br />4 <br />N/A <br />+35,3/-38.2 <br />5 <br />N/A <br />+35.3/-41,2 <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P,S,F, <br />(MINIMUM), THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED t COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S,F, <br />FOUNDATION LOADING. <br />T.L. HANSON. A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />T.L, HANSON SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS E SLAB -ON -GRADS - <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING, <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL, <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR "5 REBAR, 30" FOR 06 REBAR t 35" FOR "1 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />FINAL SITE GRADING), THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OFF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS, <br />TIMBER MATERIALS: <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION. <br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />"USP" OR "SIMPSON" CONNECTORS SHOWN. <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 "2 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-II INSULATION <br />ATTIC ACCESS: <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ, FT. AND HAVING MINIMUM <br />30 INCHES OF VERTICAL HEIGHT. ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES, <br />WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION M1305,1.3 <br />DRAFTSTOPPING: <br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN <br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING <br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR <br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SQ, FT, <br />NVAC FLAN N.T.S. <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED, THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES, THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />DO NOT APPLY, A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR, THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL, <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING t COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT, <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION), ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS (PER FBC R318), <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS, <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />TRUSSES: <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON 4 ASSOCIATES IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT, <br />EXTERIOR WINDOWS # DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/I62 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1,5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW t DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />ELECTRICAL, PLUMBING E MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411,003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS, <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT, <br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />"AFI" CIRCUIT. <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(U GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES, <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 $0. FT, <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR, <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING, <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING, <br />PRODUCT CATEGORY <br />STRUCTURAL COMPONET <br />ROOFING <br />ROOFING <br />WINDOWS <br />WINDOWS <br />SOFFIT E FASCIA TRIM <br />EXTERIOR DOORS <br />APPROVED PRODUCT LIST <br />SUB CATEGORY MANUFACTURER <br />H10 <br />ASPHALT <br />UNDERLAYMENT <br />SINGLE HUNG <br />NON IMPACT <br />FIXED GLASS <br />NON IMPACT <br />SIMPSON <br />GAF SINGLES ALL <br />GAF <br />PLYGEM 1500 <br />PLYGEM 1500 <br />STATE OF FL. <br />APPROVAL " <br />FL 10456 <br />FL 10124.1 <br />FL 10626.1 <br />FL 16103.1 <br />FL 16104.2 <br />SOFFIT AMERICAN CONSTRUCTION METALS FL 1201CM <br />DOUBLE SWINGING PLAST PRO FL 15221.10 <br />ELECTRICAL LEGEND <br />220 V G.F,I, 110 V <br />J GROUND FAULT <br />(� SWITCH RECEPTACLE <br />IIOV LIGHT <br />110 V CAN BE CEILING <br />OR WALL (TYP) <br />WP 110 V <br />(� WATERPROOF SMOKE <br />`D OUTLET lie DETECTOR <br />CARBON <br />CEILING OC MONOXIDE <br />FAN W/ LIGHT UNIT <br />WALL SCONCE <br />1/2" COX OR 1116" 0513 ROOF SNFATNING <br />NAILED PER ROOF SHEATHING DETAIL <br />WITH SD NAILS, USE STEEL PLYCLIPS <br />AND GAF UNDERLAYMENT AND GAF <br />SHINGLES, <br />SEE TRUSS LAYOUT <br />2X4 WOOD SUB FASCIA WITH <br />ALUMINUM FASCIA AND DRIP <br />ALUMINUM SOFFIT <br />VINLY INSULATED WINDOWS <br />2X4 »2 SPRUCE STUD WALL SPACED 16" OC WITH 1/2" CDX <br />OR 1/16" OSB WALL WALL SHEATHING NAILS 3" OC ON <br />ALL PLATES AND 6" OC ON VERTICAL STUDS. COVER <br />WITH TYVEK HOUSE WRAP AND GALV PAPER BACK <br />WIRE LATH AND 1/8" STUCCO, <br />SINGLE 2X4 P.T. BOTTOM PLATE SECURED <br />TO SLAB WITH A301 ALL THREAD RODS <br />PLACED AS SHOW ON FLOOR PLAN <br />GRADE ro <br />1211 <br />ENGINEERED ROOF <br />TRUSSES 24" OC <br />MINIMUM R-30 INSULATION <br />IN ATTIC AREAS <br />1/2" CEILING TYPE <br />DBL 2 X 4 GYPSUM BOARD <br />TOP PLATE <br />DBL 2 X 12 02 PINE WITH ONE <br />LAYER 1/2" PLYWOOD IN CENTER <br />OVER ALL DOOR AND WINDOW <br />OPENINGS <br />0 <br />■ <br />1 <br />U <br />cy) <br />N <br />LO <br />Z <br />M <br />co <br />Q <br />5H <br />0 <br />R <br />LL <br />_I <br />O <br />N <br />z <br />_ <br />U <br />N <br />LO <br />Z W <br />~ <br />U 0 <br />X1)X <br />Q <br />C/2 <br />UU <br />L L <br />A <br />Z ELN <br />N <br />0 <br />LO <br />00 CD 0) <br />LO <br />co <br />W <br />2 <br />U_ <br />LL <br />LL <br />C <br />N <br />co <br />O <br />>.n <br />Ul <br />0 <br />R-13 INSULATION IN WALLS WITH <br />Q <br />X m <br />1/2" GYPSUM WALLBOARD. <br />V <br />N <br />m w <br />Z <br />z <br />w� <br />W <br />u <br />Wz <br />o <br />w� o <br />TYPICAL 4" CONCRETE SLAB WITH WIRE MESH <br />(n <br />N <br />Z <br />z <br />OR FIBER MESH AND rc MILL VISQUEEN OVER <br />Z <br />W <br />n <br />o U = <br />CLEAN COMPACT TERMITE TREATED SOIL <br />W <br />N <br />U <br />zz <br />a Q <br />3ii <br />W <br />i <br />I <br />Q <br />zz <br />5 <br />Lu <br />_ I5"X12" MONO FOOTINGS WITH <br />, <br />2 EACH 05 REBAR ON CHAIRS <br />n <br />2X4 WOOD EXTERIOR WALL DETAIL <br />NOT TO SCALE <br />ELECTRICAL FLAN 1/411 11 OI' <br />CD <br />z <br />1--1 <br />�I <br />O <br />l� <br />v • <br />�Q <br />1 <br />Z <br />n� <br />Qljtj <br />Z <br />V <br />n <br />Lu <br />N <br />m <br />LIVING <br />318 SQ, FT, <br />0ANSOI°? .EENE N38654 <br />'� �,O.BOX 1128*AD CIT' , FLT526 <br />I HERBY Cr T1�S,PLA i SPECIFICATIONS <br />WERE PRE $ 1 OR UNDI FIG <br />%V C IRECT SUPERVISION <br />ARE IN CO 1�H Capibt/hECTION 1609 OF THE <br />FLORIDA BUILC bd f 261Yx6Ti 6lfION AND ASCE 1-10 3 O 3 <br />FOR 139 MPH WIN1 ESYC x T,ECaORY II AND THE ENTIRE <br />2011 BUILDING COD ' 16,$Ll1L 6TH EDITION <br />