240 CFM <br />RG._.1.: .' I <br />.... ..... <br />...m.. <br />m <br />S <br />10' 0 <br />_ 260 <br />FLEXIBLE DUCT RUNOUT TO <br />AIR DEVICE. PROVIDE <br />CAN CONNECTION TO TRUNK <br />1 MECHNAICAL PLAN <br />M-1 SCALE: 1 /4" = 1'-0" <br />HANGER STRAP, 1 22 GAUGE <br />SHEET METAL. TYPICAL <br />WRAP INSULATION ABOVE <br />THE CEILING DIFFUSERS <br />rt RGLASS KCT: <br />BOA (R15) <br />SUPPL IR <br />DUC <br />RADIUS NOT LESS THAN <br />CONICAL SPIN -IN FITTING,X THE FLEX DUCT <br />WITH DAMPER DIAMETER <br />(OMIT DAMPER IF PROVIDED IN DIFFUSER) <br />3 SHEET METAL SCREWS THRU HELIX <br />OF FLEXIBLE DUCT, BAND CLAMP, TAPED FLEXIBLE DUCT, 'THERMAFLEX MKE" <br />NOTE: OR "METALFLEX", INSULATED <br />PROVIDE OPPOSED BLADE DAMPER DO NOT SAG OR KINK <br />IN DRYWALL CEILINGS. <br />FLEXIBLE DUCT RUNOUT <br />SCALE: NONE <br />80 CFM 80 CFM <br />00 <br />�20 <br />MECHANICAL LEGEND <br />AxB, AUK SUPPLY AIR DUCT, DIMENSION "A" SHOWN <br />AxB, ARETURN AIR DUCT, DIMENSION "A" SHOWN <br />FLEXIBLE DUCTWORK, SAME SIZE AS DIFFUSER NECK <br />-�-�- REFRIGERANT PIPING <br />CONDENSATE DRAIN PIPING <br />FZ® SUPPLY AIR DIFFUSERS <br />121 RETURN AIR GRILLE <br />® EXHAUST AIR GRILLE <br />FIRE DAMPER <br />Jw VOLUME DAMPER <br />CD THERMOSTAT, 48" A.F.F. <br />® ROOFTOP EXHAUST FAN <br />® CEILING EXHAUST FAN <br />HVAC EQUIPMENT TAG <br />CU DENOTES EQUIPMENT TYPE <br />1 -DENOTES EQUIPMENT NUMBER <br />AIR DEVICE TAG <br />RG-1 DENOTES DEVICE TYPE <br />6 DENOTES NECK/FLEX DUCT SIZE <br />60 -DENOTES AIR FLOW (CFM) <br />KEYED NOTES: (D <br />1. EXISTING SPLIT AIR HANDLING <br />UNIT WITH ELECTRIC HEAT TO REMAIN. <br />CLEAN/SERVICE/REPAIR UNIT AS <br />NECESSARY TO LIKE NEW CONDITION. RE -CONNECT <br />NEW DUCTWORK AS SHOWN ON <br />PLAN. RE -BALANCE AIR FLOWS TO VALUES AS <br />FOLLOWS: <br />A) EXISTING 4 TON UNIT: <br />SUPPLY AIR: 1,475 <br />CFM <br />RETURN AIR: 1,235 <br />CFM <br />OUTSIDE AIR: 240 <br />CFM <br />B) EXISTING 4 TON UNIT, RELOCATE AS SHOWN: <br />SUPPLY AIR: 1,400 <br />CFM <br />RETURN AIR: 1,200 <br />CFM <br />OUTSIDE AIR: 200 <br />CFM <br />2. PROVIDE NEW BATHROOM EXHAUST FAN AND 6" 0 METAL EXHAUST DUCT TO WALL <br />CAP. CONNECT FAN TO ROOM LIGHT <br />SWITCH FOR SIMULTANEOUS OPERATION. <br />3. PROVIDE NEW DIGITAL 7-DAY <br />TEMPERATURE CONTROLLER ON WALL WITH LOCKING <br />CLEAR PLASTIC COVER. MOUNT CONTROLLER MAX. 48" A.F.F. <br />4. PROVIDE 18x6 LOUVER LOW <br />IN DOOR (OR LOUVERED BI-FOLD) FOR RETURN AIR <br />FROM THIS ROOM. COORDINATE <br />EXACT STYLE, FINISH, AND PLACEMENT WITH ARCH. <br />AIR BALANCE + OUTSIDE AIR CALCULATIONS <br />BASED ON 2007 FLORIDA MECHANICAL CODE, TABLE 403.3 <br />VENTILATION <br />SPACE TYPE MEDICAL OFFICE <br />AREA OF USABLE SPACE/PEOPLE 1923 SQFT <br /># OF PEOPLE 7 /1000 SQFT <br />MIN. VENT. MULTIPLIER 20 CFM/PERSON <br />MIN. REQUIRED VENTILATION 269.2 CFM <br />VENTILATION PROVIDED 440 CFM <br />AIR BALANCE <br />OUTSIDE AIR INTAKES <br />EXHAUST AIR <br />OUTLETS <br />EXIST AHU-1 <br />240 <br />CFM <br />EXIST AHU-2 <br />200 <br />CFM <br />EF-1 2 <br />() <br />160 CFM <br />440 <br />CFM <br />160 CFM <br />PRESSURIZATION <br />63.64 <br />% <br />(OA-EA)/OA <br />x 100% <br />AIR DEVICE <br />SCHEDULE <br />TAG <br />FACE SIZE <br />MATERIAL <br />FINISH <br />MANUFACTURER <br />MODEL <br />NOTES <br />SD-1 <br />24x24 <br />STEEL <br />WHITE <br />PRICE <br />SCD <br />1,2,3 <br />RG-1 <br />24x24 <br />STEEL <br />WHITE <br />PRICE <br />PFRF <br />1,2 <br />1. <br />2. <br />3. <br />REFER TO PLANS FOR ALL NECK SIZES. <br />NOISE CRITERIA NOT TO EXCEED 30 NC. <br />ALL CEILING DIFFUSERS ARE 4-WAY THROW, UNLESS NOTED <br />ON PLAN. <br />EXHAUST FAN <br />SCHEDULE <br />TAG <br />AREA SERVED <br />FAN <br />TYPE <br />DRIVE <br />TYPE <br />AIRFLOW <br />(CFM) <br />E.S.P. <br />("W.C.) <br />RPM <br />FAN <br />HP <br />VOLTAGE <br />(V/OHz) <br />SONES <br />DUCT <br />SIZE <br />MANUFACTURER <br />MODEL <br />ACCESS. <br />EF-1 <br />SINGLE TOILET <br />CENT. <br />DIRECT <br />80 <br />0.10 <br />900 <br />54W <br />120/1/60 <br />2.5 <br />40 <br />GREENHECK <br />SP-B80 <br />2,3,4,5,E <br />STANDARD <br />ACCESSORIES: <br />NOTES <br />1 <br />ROOF CURB <br />1. <br />2. <br />PROVIDE VIBRATION ISOLATORS <br />CONNECT EF-1 TO OPERATE <br />WITH ALL FANS. <br />WITH WALL SWITCH. <br />2 <br />BACKDRAFT DAMPER <br />3 <br />BIRDSCREEN <br />4 <br />WALL/ROOF CAP <br />5 <br />DISCONNECT <br />6 <br />SPEED CONTROLLER <br />THREADED ROD HANGER TRAPEZE <br />WITH VIBRATION ISOLATORS (TYP.) <br />INTEGRAL BACKDRAFT DAMPER <br />AIRFLOW <br />EXHAUST FAN INSTALLATION <br />SCALE: NONE <br />CEILING FAN <br />CEILING GRILLE <br />MECHANICAL SPECIFICATIONS: <br />1. GENERAL <br />9, DUCTWORK <br />A. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED FOR A <br />A. SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS" AND "FIBROUS GLASS DUCT <br />COMPLETE SYSTEM AS OUTLINED IN THE CONTRACT DRAWINGS AND THESE <br />CONSTRUCTION STANDARDS" SHALL BE CONSIDERED PART OF THE SPECIFICATIONS FOR <br />SPECIFICATIONS. <br />THIS PROJECT. ANY WORK WHICH DOES NOT CONFORM TO THESE STANDARDS MAY BE <br />B. NOTE THAT DRAWINGS ARE DIAGRAMMATIC ONLY AND INTENDED TO SHOW <br />REJECTED AT ANY TIME. <br />THE GENERAL ARRANGEMENT OF SYSTEMS, NOT EVERY MINUTE DETAIL. <br />B. NOT USED. <br />C. DO NOT SCALE PLANS. <br />C. ALL NEW SUPPLY AND RETURN AIR DUCTWORK SHALL BE CONSTRUCTED OF 1.5" <br />D. PROVIDE ALL NECESSARY FITTINGS, TRANSITITONS, CONNECTORS, ETC. <br />THICK R-6 FOIL FACED ANTI -MICROBIAL FIBERGLASS DUCT BOARD, TAPED AND SEALED, <br />WHETHER SHOWN OR NOT ON PLANS. <br />BY KNAUF, JOHNS MANVILLE, OWENS CORNING, OR EQUIVALENT, <br />E. ALL WORK IS NEW UNLESS OTHERWISE NOTED. <br />D. ALL EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED STEEL, <br />F. THESE PLANS REPRESENT THE DESIGN INTENT BASED ON INFORMATION <br />SMACNA 1 INCH PRESSURE CLASS, SMACNA "A" SEAL CLASS. PROVIDE GRAVITY <br />AVAILABLE AT THE TIME OF DESIGN. ANY SUBSTANTIAL MODIFICATIONS OR <br />BACKDRAFT DAMPERS IN ALL EXHAUST DUCTS NEAR THE BUILDING EXIT POINT. <br />ALTERATIONS MADE DURING THE CONSTRUCTION PHASE SHALL BE REPORTED <br />E. ALL FLEXIBLE DUCTWORK SHALL BE THERMAFLEX TYPE M-KE R-6 OR EQUIVALENT. <br />TO THE ENGINEER PRIOR TO WORK. MODIFICATIONS MADE WITHOUT THE <br />NO FLEX DUCT SHALL EXCEED 10'-0" IN LENGTH. <br />ENGINEER'S WRITTEN APPROVAL SHALL REMAIN THE RESPONSIBILITY OF THE <br />F. NOT USED. <br />CONTRACTOR. <br />G. NOT USED. <br />G. IN CASE OF ANY DISCREPANCIES BETWEEN THE DRAWINGS, <br />H. DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. DUCT SIZE <br />SPECIFICATIONS, FIELD CONDITIONS, CODES, ETC. IT IS THE RESPONSIBILITY <br />SUBSTITUTIONS ARE ACCEPTABLE ONLY IF THE CLEAR AREA SUBSTITUTED IS NOT LESS <br />OF THE CONTRACTOR TO REFER ALL SUCH MATTERS TO THE ENGINEER IN <br />THAN THAT SHOWN AND THE DUCT ASPECT RATIO IS LESS THAN 4 TO 1. <br />WRITING IMMEDIATELY FOR RESOLUTION PRIOR TO EXECUTING ANY WORK. ANY <br />J. PROVIDE 45-DEGREE ENTRY ON ALL RECTANGULAR BRANCH CONNECTIONS. PROVIDE <br />WORK PERFORMED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER <br />CONICAL TAPS WITH DAMPERS ON ALL ROUND BRANCH CONNECTIONS. <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />K. PROVIDE LONG RADIUS ELBOWS, 3-PIECE ELBOWS, OR TURNING VANES AT ALL <br />H. ALL WORK SHALL CONFORM TO THE FOLLOWING CODES (AS APPLICABLE) <br />90-DEGREE TURNS. SUBSTITUTION OF SQUARE ELBOWS IS NOT ACCEPTABLE. <br />AS WELL AS ALL LOCAL REGULATIONS, ORDINANCES, AND AMENDMENTS: <br />L. TEST ALL DUCTWORK FOR LEAKS PRIOR TO CONCEALING. MAXIMUM LEAKAGE RATE IS <br />2007 FLORIDA BUILDING CODE W/ 2009 SUPPLEMENT <br />5 PERCENT. <br />M. DUCTWORK SHALL NOT BE SUPPORTED BY ANYTHING OTHER THAN THE BUILDING <br />2. SCOPE OF WORK <br />STRUCTURE. LIKEWISE, NOTHING SHALL BE SUPPORTED BY THE DUCTWORK. <br />RELOCATE ONE EXISTING AIR HANDLING UNIT. PROVIDE NEW SUPPLY, RETURN, <br />N. PROVIDE VOLUME DAMPERS AT ALL BRANCH TAKE -OFFS OR AS INDICATED ON <br />AND OUTSIDE AIR DUCTWORK FOR BOTH AIR HANDLING UNITS AS SHOWN. <br />PLANS. PROVIDE VOLUME DAMPERS IN ALL AIR DEVICES LOCATED IN HARD CEILINGS. <br />PROVIDE NEW EXHAUST FANS IN TOILETS. <br />P. PROVIDE NORMALLY CLOSED MOTORIZED OUTSIDE AIR DAMPERS TO AUTOMATICALLY <br />OPEN ONLY IN THE OCCUPIED MODE WITH THE COMPRESSOR OR HEAT STRIP <br />3. ITEMS FURNISHED BY CONTRACTOR <br />ENERGIZED. <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL <br />Q. PROVIDE FIRE PROOF FLEXIBLE CONNECTORS AT ALL DUCT CONNECTIONS TO FANS <br />MATERIALS, EQUIPMENT, AND ACCESSORIES NECESSARY TO MAKE A COMPLETE <br />OR AIR HANDLING UNITS, UNLESS SPECIFICALLY NOTED OTHERWISE. <br />INSTALLATION. ALL EQUIPMENT SHALL BE STORED IN A SAFE, DRY PLACE IN <br />THE MANUFACTURER'S ORIGINAL PACKAGING UNTIL READY FOR USE. THE <br />10. FILTERS & BELTS <br />OWNER SHALL NOT BE RESPONSIBLE FOR PROVIDING ANY PART OF THE <br />A. FILTERS SHALL BE OF A SIZE AND ARRANGEMENT SUITABLE TO THE REQUIREMENTS <br />PROJECT, UNLESS SPECIFICALLY NOTED. THE CONTRACTOR SHALL ALSO BE <br />OF THE EQUIPMENT. FILTERS SHALL BE THE WASHABLE TYPE AND PROVIDE 30% <br />RESPONSIBLE FOR PAYING ALL REQUIRED FEES, OBTAINING ALL PERMITS, AND <br />EFFICIENCY. <br />ARRANGING FOR ALL INSPECTIONS, INCLUDING COORDINATION WITH AND <br />B. BELTS SHALL BE REINFORCED RUBBER "V" NOTCH TYPE SUITABLE FOR THE <br />SATISFYING ALL REQUIREMENTS OF ANY APPLICABLE UTILITY COMPANY(IES) AS <br />EQUIPMENT ON WHICH THEY ARE INSTALLED. <br />MAY BE REQUIRED TO EXECUTE THIS SCOPE OF WORK. <br />C. AIR HANDLING UNITS SHALL NOT BE STARTED UNTIL ALL ROUGH CONSTRUCTION IS <br />COMPLETE OR AS OTHERWISE DIRECTED BY THE MANUFACTURER. CHANGE ALL AIR <br />4. WORK IN EXISTING BUILDINGS <br />HANDLING UNIT FILTERS AT THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES. <br />A. DO NOT USE POWDER DRIVEN FASTENERS OF ANY TYPE. <br />D. PROVIDE 2 SPARE SETS OF FILTERS AND BELTS FOR ALL EQUIPMENT. <br />B. ALL ITEMS REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE <br />OWNER. CONTRACTOR SHALL REMOVE ANY UNSATISFACTORY ITEMS FROM THE <br />11. TEMPERATURE CONTROL <br />PROJECT SITE. <br />A. PROVIDE A REMOTE THERMOSTAT FOR CONTROLLING EACH AIR CONDITIONING <br />C. SOME EXISTING ITEMS TO REMAIN WITHOUT WORK ARE SHOWN FOR <br />SYSTEM. ALL THERMOSTATS SHALL BE DIGITAL 7-DAY PROGRAMMABLE TYPE, LOW <br />CLARITY OR REFERENCE ONLY. NOTE THAT ADDITIONAL ITEMS WITHOUT WORK <br />VOLTAGE, WALL MOUNTED, 48" ABOVE FINISHED FLOOR. THE MECHANICAL CONTRACTOR <br />MAY ALSO BE PRESENT. <br />SHALL PROVIDE ALL LOW VOLTAGE WIRING AND SEAL PENETRATIONS BEHIND <br />D. DRAWINGS OF EXISTING SYSTEMS ARE BASED ON EXISTING DOCUMENTS <br />THERMOSTATS WITH EXPANDABLE FOAM INSULATION. THERMOSTATS SHALL HAVE <br />AND FIELD CONDITIONS, SOME OF WHICH MAY BE UNVERIFIED. PRIOR TO <br />SETTINGS FOR "HEAT" AND "COOL" TO PROVIDE COOLING AND STAGES OF HEATING AS <br />SUBMITTING A BID, CONTRACTOR SHALL STUDY THE PLANS AND VISIT THE <br />LISTED IN THE SCHEDULE. THERMOSTATS SHALL ALSO HAVE FAN SETTINGS OF <br />PROJECT SITE IN ORDER TO BECOME FAMILIAR WITH EXISTING CONDITIONS. <br />"ON" -"OFF" -"AUTO". <br />ANY DISCREPANCIES IN THE CONTRACT DOCUMENTS WHICH COULD <br />B. ALL ELECTRIC HEATERS SHALL BE INTERLOCKED WITH AIR HANDLING UNITS TO <br />SIGNIFICANTLY IMPACT THE PROJECT BUDGET OR SCHEDULE MUST BE <br />PROVIDE HEATER SHUTDOWN IN THE EVENT OF FAN FAILURE. HEATER OPERATION <br />REPORTED TO THE ENGINEER IN WRITING IMMEDIATELY. FAILURE TO DO SO <br />SHALL REQUIRE AIRFLOW. <br />WILL NOT BE SUFFICIENT CAUSE FOR DELAYS OR CHANGES LATER IN THE <br />C. PROVIDE HUMIDISTATS FOR CONTROL OF ALL HOT GAS REHEAT COILS. MOUNT <br />PROJECT. CHANGE ORDERS RESULTING FROM FAILURE TO PROPERLY <br />ADJACENT TO THERMOSTAT FOR SAME SYSTEM. SYSTEMS SHALL ENTER <br />INVESTIGATE EXISTING FIELD CONDITIONS WILL NOT BE ACCEPTED. ALL WORK <br />"DEHUMIDIFICATION" MODE UPON SENSING 60% OR GREATER RELATIVE HUMIDITY AND <br />IS NEW UNLESS OTHERWISE NOTED. <br />MAINTAIN THIS MODE UNTIL HUMIDITY DROPS BELOW 50%. <br />E. MODIFICATIONS TO EXISTING SYSTEMS NECESSARY TO CONNECT TO NEW <br />D. ACCEPTABLE MANUFACTURERS ARE: CARRIER, TRANE, WHITE-RODGERS, AND <br />WORK SHALL BE CONSIDERED TO BE PART OF THE BASIC WORK OF THIS <br />HONEYWELL. <br />CONTRACT. <br />F. COORDINATE ALL WORK SCHEDULES WITH THE OWNER TO MINIMIZE <br />12. ELECTRICAL <br />DISRUPTIONS TO EXISTING SYSTEMS OUTSIDE THIS SCOPE OF WORK. <br />A. PROVIDE ALL STARTERS, CONTACTORS, RELAYS, CONTROLS, AND ACCESSORIES TO <br />PROVIDE A COMPLETE POWER AND CONTROL WORKING SYSTEM. THE ELECTRICAL <br />5. COORDINATION <br />CONTRACTOR SHALL PROVIDE ALL DISCONNECT SWITCHES, CONDUIT, AND WIRING FOR <br />ALL WORK ON THIS PROJECT SHALL BE COORDINATED WITH THE OWNER AND <br />ALL EQUIPMENT. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH <br />ALL OTHER TRADES PRIOR TO BEGINNING AY WORK OR ORDERING ANY <br />THE ELECTRICAL SPECIFICATIONS OF THESE DOCUMENTS AND THE NATIONAL ELECTRICAL <br />MATERIALS. CONTRACTOR SHALL REVIEW PLANS OF ALL DISCIPLINES INVOLVED <br />CODE. <br />AND ADVISE THE ARCHITECT IN WRITING OF ANY CONFLICTS, CODE OR SAFETY <br />B. THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL WIRING DIAGRAMS, BE <br />ISSUES THAT MAY EXIST PRIOR TO ANY FABRICATION OR ORDERING OF <br />RESPONSIBLE FOR PROPER OPERATION OF THE COMPLETE SYSTEM, AND SHALL <br />EQUIPMENT. RESOLUTION OF SUCH CONFLICTS WHICH ARE NOT REPORTED <br />SUPERVISE ALL WIRING OF MECHANICAL EQUIPMENT. COORDINATE THE INSTALLATION OF <br />PRIOR TO CONSTRUCTION SHALL REMAIN THE RESPONSIBILITY OF THE <br />ALL EQUIPMENT WITH AND PROVIDE ALL WIRING DIAGRAMS TO THE ELECTRICAL <br />CONTRACTOR AND CHANGE ORDER PROPOSALS FOR SUCH WORK WILL NOT <br />CONTRACTOR PRIOR TO THE ELECTRICAL CONTRACTOR BEGINNING ANY WORK <br />BE ACCEPTED. PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID <br />C. NO WIRING OF ANY KIND SHALL BE EXPOSED IN FINISHED AREAS. WIRING TO ALL <br />CONFLICTS WITH STRUCTURE, FINISHES, AND WORK OF OTHERS. CONTRACTOR <br />MOTORS OR OTHER ELECTRICAL EQUIPMENT SHALL HAVE HEATER ELEMENTS IN EACH <br />SHALL PROVIDE ALL CORE PENETRATIONS AND PATCHING FOR FLOOR <br />PHASE WITH EITHER THE STARTER OR THE CONTACTOR. ALL MOTORS SHALL BE WOUND <br />PENETRATIONS. <br />FOR THE VOLTAGE SPECIFIED AND SHALL HAVE A NAMEPLATE STATING THAT VOLTAGE <br />AND CORRESPONDING AMPERES. WHERE MORE THAN ONE MOTOR OR OTHER <br />6. BASIS OF DESIGN <br />EQUIPMENT IS CONTROLLED BY THE SAME CIRCUIT, OR WHEN THE LOAD EXCEEDS THE <br />A. THE MECHANICAL CONTRACT DOCUMENTS HAVE BEEN PREPARED USING <br />CAPACITY OF THE CONTROL EQUIPMENT, THE CONTRACTOR SHALL PROVIDE ALL <br />THE ASHRAE 97.5% DESIGN CRITERIA WITH THE FOLLOWING DESIGN <br />NECESSARY CONTROLS AND RELAYS. <br />CONDITIONS: <br />INDOOR OUTDOOR <br />13. WARRANTIES AND MAINTENANCE <br />SUMMER 75F DB/50% RH 92F DB/79F WB <br />A. ALL EQUIPMENT SHALL BE STARTED, TESTED, ADJUSTED, LUBRICATED, CLEANED, AND <br />WINTER 72F DB 36F DB <br />PLACED IN GOOD OPERATING CONDITION BY THE CONTRACTOR. CONTRACTOR SHALL <br />B. THE FOLLOWING BUILDING MATERIALS/INSULATION R-VALUES WERE USED <br />GUARANTEE ALL EQUIPMENT, MATERIALS, AND WORKMANSHIP TO BE FREE OF DEFECTS <br />IN THE HVAC CALCULATIONS. IF THE ACTUAL MATERIALS TO BE USED IN THE <br />FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER AND <br />CONSTRUCTION PHASE (VERIFY WITH ARCH.) DIFFER FROM THESE <br />THE CONTRACTOR SHALL REPAIR ANY SUCH DEFECTS AT NO COST TO THE OWNER. ALL <br />SPECIFICATIONS, PARTICULARLY WITH REGARD TO THE ROOF, CONTACT THE <br />EQUIPMENT INCLUDED IN THE PROJECT SHALL BE COVERED BY THE MANUFACTURER'S <br />ENGINEER PRIOR TO CONSTRUCTION IN WRITING IMMEDIATELY TO VERIFY THE <br />WARRANTY FOR THE DURATION OF THAT WARRANTY. COPIES OF ALL MANUFACTURER'S <br />ABILITY OF THE HVAC SYSTEMS TO EFFECTIVELY CONDITON THE SPACE: <br />WARRANTIES AND CONTRACTOR WARRANTIES SHALL BE PROVIDED TO THE OWNER AT <br />WALLS: BLOCK WALLS WITH R-4 BOARD INSULATION <br />FINAL ACCEPTANCE. <br />ROOF: FLAT BUILDING ROOF WITH R-19 BATT INSULATION <br />B. CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE AND REVIEW ALL <br />FLOOR: CONCRETE FLOOR SLAB ON GRADE, NO INSULATION <br />OPERATIONS AND MAINTENANCE OF ALL SYSTEMS. CONTRACTOR SHALL PROVIDE THE <br />GLASS: SINGLE PANE TINTED GLASS WITH NO INTERNAL SHADES <br />OWNER WITH BOUND COPIES OF ALL OPERATION AND MAINTENANCE MANUALS <br />INCLUDING PARTS LISTS, MAINTENANCE SCHEDULES, ETC. <br />7. FANS <br />C. THE CONTRACTOR SHALL CONTINUALLY RECORD ANY AND ALL DEVIATIONS TO THE <br />A. ALL FANS SHALL BEAR THE AMCA CERTIFIED RATINGS LABEL AND THE UL <br />CONTRACT DOCUMENTS MADE DURING CONSTRUCTION AND PROVIDE A COMPLETE SET <br />LABEL. ALL FAN MOTORS SHALL BE PROPERLY GROUNDED. <br />OF THESE RECORD DRAWINGS TO THE OWNER WITHIN 30 DAYS OF COMPLETION OF <br />B. ALL FANS SHALL HAVE A SOUND LEVEL RATING NOT IN EXCESS OF THAT <br />CONSTRUCTION. IF REQUIRED BY THE AUTHORITY HAVING JURISDICTION, IT SHALL BE <br />SPECIFIED. <br />THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE THE SERVICES OF A LICENSED <br />C. ALL CENTRIFUGAL FANS SHALL HAVE TRUE WHEEL WITH INLET <br />PROFESSIONAL ENGINEER TO PROVIDE SIGNED AND SEALED RECORD DRAWINGS. <br />PERPENDICULAR TO DISCHARGE. <br />D. ROOF MOUNTED FANS SHALL HAVE SPUN ALUMINUM HOUSINGS, ROOF <br />20. TEST AND BALANCE <br />CURB, AND DISCONNECT SWITCH MOUNTED INSIDE THE HOUSING. INTEGRAL <br />A. IF THE BUILDING'S MECHANICAL SYSTEMS ARE 15 TONS OR LESS PER SYSTEM, THE <br />BACKDRAFT DAMPERS SHALL BE TOTALLY CHATTERPROOF WITH NO METAL <br />MECHANICAL CONTRACTOR MAY TEST, ADJUST, AND BALANCE THE SYSTEM. <br />CONTACT. <br />B. AIR SYSTEM BALANCING SHALL BE ACCOMPLISHED IN A MANNER TO FIRST REDUCE <br />E. CEILING EXHAUST FANS SHALL HAVE ACOUSTICALLY LINED HOUSINGS AND <br />THROTTLING LOSSES, THEN FAN SPEED SHALL BE ADJUSTED TO MEET DESIGN FLOW <br />SHALL BE PROVIDED WITH A TERMINAL BOX ON THE INSIDE OF THE HOUSING <br />CONDITIONS, EXCEPT THAT DAMPER THROTTLING MAY BE USED FOR BALANCING FAN <br />WITH CORD, PLUG, AND RECEPTACLE. ENTIRE FAN, MOTOR, AND WHEEL <br />MOTORS OF 1 HORSEPOWER OR LESS, OR IF DAMPER THROTTLING RESULTS IN NO <br />ASSEMBLY SHALL BE EASILY REMOVABLE WITHOUT DISTURBING THE HOUSING. <br />GREATER THAN 1 /3 HORSEPOWER DRAW ABOVE THAT REQUIRED IF THE FAN SPEED <br />F. ACCEPTABLE MANUFACTURERS ARE: GREENHECK, COOK, PENN, AND BROAN. <br />WERE ADJUSTED. <br />8. AIR DISTRIBUTION DEVICES <br />E. SPECIFIC TESTS INCLUDE (BUT ARE NOT LIMITED TO): <br />A. PROVIDE AND INSTALL ALL AIR DEVICES IN LOCATIONS INDICATED ON <br />TEST & ADJUST SUPPLY FAN RPM TO DESIGN REQUIREMENTS. <br />DRAWINGS. VERIFY LOCATIONS AND CEILING TYPES WITH ARCH. PRIOR TO <br />TEST & RECORD MOTOR LOAD AMPERES. DO NOT EXCEED NAMEPLATE RATING.IFIC <br />ORDERING. PROVIDE INTEGRAL VOLUME DAMPER FOR ALL AIR DEVICES <br />TEST & RECORD SYSTEM STATIC PRESSURES. <br />LOCATED IN HARD CEILINGS AND INTEGRAL RADIATION DAMPER FOR ALL <br />TEST & RECORD INDOOR COIL ENTERING & LEAVING AIR CONDITIONS. <br />DEVICES LOCATED IN RATED CEILINGS. <br />TEST & RECORD INDOOR COIL LEAVING AIR CONDITIONS. <br />B. ALL AIR DEVICES SHALL BE STEEL. FINISH OF ALL DEVICES SHALL BE <br />TEST & ADJUST EACH AIR DISTRIBUTION DEVICE TO PROVIDE AIRFLOW <br />WHITE UNLESS OTHERWISE NOTED ON PLANS. THE CONTRACTOR SHALL <br />WITHIN 10 PERCENT OF DESIGN. <br />VERIFY FINISH COLOR AND STYLE OF ALL AIR DEVICES WITH THE ARCHITECT <br />TEST & VERIFY OPERATION OF ALL ELECTRIC HEATERS. <br />PRIOR TO ORDERING. <br />C. ALL SURFACES OF DUCTWORK VISIBLE THROUGH AIR DEVICES SHALL BE <br />PAINTED FLAT BLACK. <br />D. ACCEPTABLE MANUFACTURERS ARE: TITUS, PRICE, METALAIRE, TUTTLE & <br />BAILEY, AND BARBER COLEMAN. <br />x � <br />H.-Ek"wR °`4w <br />Hg 'UP <br />WOzPa o-° oazx°m <br />UrywZ v�r wpOa96, <br />3 �H zx EE. <br />Vi¢��Wc{1Y�, �W WWzO X <br />ay"��"WQfal�a�� aQ°N°W <br />� a �uo ' 33zzoz <br />z azoo �:MZW5 � <br />O <br />H <br />G] <br />O <br />U) <br />Q <br />O <br />Q <br />Z <br />QQ <br />a <br />� <br />a <br />w <br />w <br />U <br />Nu <br />L <br />z <br />L <br />Ln <br />U <br />W <br />N <br />U <br />� <br />w <br />Q <br />w <br />Cn <br />� <br />w <br />ca. <br />A <br />zU).. <br />�. <br />. ........... . <br />..... ..... ......... .... .. <br />o� <br />M. <br />Q <br />v <br />aU <br />. :4� <br />N <br />E~ <br />}--i t� <br />� <br />.. <br />o <br />°oa <br />U <br />o . <br />z <br />o <br />o <br />za <br />Wz <br />Q° <br />a� <br />¢3 <br />U <br />DRAWN BY: <br />VCD <br />Q� <br />o <br />DATE: <br />05/10/2011 <br />v� <br />�o <br />a U <br />DCH PROJECT n: <br />11-015 <br />- <br />�w <br />a0 Uo <br />SHEET: <br />R <br />M-1 <br />o6 <br />UC <br />F <br />z <br />