Laserfiche WebLink
POWER SYMBOLS: <br />HOMERUN CIRCUIT TO PANELBOARD <br />CIRCUITING <br />= TIME CONTROLLED <br />= SWITCHED HOT <br />= UNSWITCHED HOT <br />= NEUTRAL <br />=GROUND <br />= ISOLATED GROUND <br />20A, 125V, DUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD <br />(� <br />20A, 125V, DUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD ISOLATED GROUND <br />20A, 125V, GFCI DUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD <br />(� <br />20A, 125V, SPLIT WIRED DUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD <br />20A, 125V, QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD <br />20A, 125V, QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD, ISOLATED GROUND <br />20A, 125V, GFCI QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD <br />20A, 125V, SPLIT WIRED QUADRUPLEX <br />RECEPTACLE (NEMA 5-20R), WALL MTD <br />(b <br />20A, 125V, SIMPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD <br />20A, 125V, SIMPLEX RECEPTACLE <br />(NEMA 5-20R), WALL MTD ISOLATED GROUND <br />POWER RECEPTACLE, FLOOR MTD <br />(SEE SPECS OR NOTES) <br />20A, 125V, DUPLEX RECEPTACLE <br />(NEMA 5-20R), FLOOR MTD <br />® <br />20A, 125V, DUPLEX RECEPTACLE <br />(NEMA 5-20R), FLOOR MTD ISOLATED GROUND <br />® <br />20A, 125V, GFCI DUPLEX RECEPTACLE <br />(NEMA 5-20R), FLOOR MTD <br />20A, 125V, QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), FLOOR MTD <br />20A, 125V, QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), FLOOR MTD ISOLATED GROUND <br />20A, 125V, GFCI QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), FLOOR MTD <br />SPECIAL PURPOSE RECEPTACLE, FLOOR MTD <br />(SEE EQUIPMENT SCHEDULE OR NOTES) <br />0 <br />20A, 125V, DUPLEX RECEPTACLE <br />(NEMA 5-20R), CEILING MTD <br />(1) <br />20A, 125V, DUPLEX RECEPTACLE <br />(NEMA 5-20R), CEILING MTD ISOLATED GROUND <br />U <br />20A, 125V, GFCI DUPLEX RECEPTACLE <br />(NEMA 5-20R), CEILING MTD <br />0 <br />20A, 125V, QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), CEILING MTD <br />0 <br />20A, 125V, QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), CEILING MTD ISOLATED GROUND <br />0 <br />20A, 125V, GFCI QUADRUPLEX RECEPTACLE <br />(NEMA 5-20R), CEILING MTD <br />SPECIAL PURPOSE RECEPTACLE, WALL MTD <br />(SEE EQUIPMENT SCHEDULE OR NOTES) <br />D <br />30A, 125 / 250V, DRYER RECEPTACLE <br />(NEMA 14-30R), WALL MTD <br />R <br />50A, 125 / 250V, RANGE RECEPTACLE <br />(NEMA 14-50R), WALL MTD <br />6 A <br />(ljl� <br />60A, 480V, 3PH, WELDING RECEPTACLE, WALL <br />MTD <br />DROP CORD (SEE SPECS OR NOTES) <br />(�O <br />POWER POLE (SEE SPECS OR NOTES) <br />® <br />RECEPTACLE RACEWAY / PLUG MOLD <br />H <br />JUNCTION BOX, WALL MTD <br />0 <br />JUNCTION BOX <br />JUNCTION BOX, FLOOR MTD <br />JUNCTION BOX, EXPLOSION PROOF <br />3NF;L'1 <br />SAFETY SWITCH, 30A, 3-POLE, NON -FUSED <br />3i3L (; -�:: I <br />SAFETY SWITCH, 30A, 3-POLE, FUSED @ 20A <br />CECI <br />STARTER OR MOTOR CONTROLLER <br />LCEO <br />STARTER, COMBINATION W/ DISC. SWITCH <br />�T <br />TRANSFORMER <br />ELECTRICAL PANEL / ENCLOSURE AS NOTED ON <br />PLAN DRAWINGS, SURFACE/RECESSED MTD <br />I� <br />208Y/120V PANELBOARD, SURFACE/RECESSED <br />MTD <br />[;-mE .fir <br />208Y/120V LIGHTING PANELBOARD, <br />SURFACE/RECESSED MTD <br />480Y/277V PANELBOARD, SURFACE MTD <br />ELECTRIC UTILITY METER <br />LIGHTING SYMBOLS: <br />NOTE: REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE <br />TYPES. REFER TO SENSOR SCHEDULE FOR SENSOR TYPES. <br />REFER TO PLAN DRAWINGS FOR ADDITIONAL SYMBOLS. <br />A: <br />CAPITAL LETTER ADJACENT TO FIXTURE = TYPE <br />a: <br />LOWERCASE LETTER = SWITCHING GROUP <br />EM: <br />EMERGENCY LIGHTING <br />NL: <br />NIGHT LIGHTING (UNSWITCHED FIXTURE) <br />xx <br />SWITCH, 20A, 120/277V, TOGGLE TYPE, U.N.O. <br />a,b,c,... =SWITCHING GROUP <br />BLANK =SINGLE POLE <br />2 =DOUBLE POLE <br />3 =THREE-WAY <br />4 =FOUR-WAY <br />D =DIMMER SWITCH <br />K =SINGLE POLE KEY OPERATED <br />L = LOW VOLTAGE <br />M =MOTOR RATED <br />P =SINGLE POLE W/ PILOT LIGHT <br />RC = REMOTE CONTROL <br />T =TIMER OPERATED SWITCH <br />ePc <br />AUTOMATIC EMERGENCY POWER TRANSFER <br />CONTROLLER <br />os <br />OCCUPANCY SENSOR, CEILING MTD <br />xx <br />Ds xx <br />DAYLIGHT SENSOR, CEILING MTD <br />Rc xx <br />ROOM CONTROLLER <br />os <br />OCCUPANCY SENSOR, WALL MTD <br />Pc <br />PHOTOCELL <br />�c <br />LIGHTING CONTACTOR <br />Tc <br />TIME CLOCK <br />2'X4' LAY -IN TROFFER <br />® <br />2'X4' LAY -IN TROFFER, NIGHT LIGHT <br />2'X4' LAY -IN TROFFER, EMERGENCY LIGHT <br />® <br />2'X2' LAY -IN TROFFER <br />® <br />1'X4' LAY -IN TROFFER <br />fo---i <br />STRIP/CHANNEL FIXTURE <br />-- <br />TRACK LIGHTING W/ DIRECTIONAL HEADS <br />® <br />DOWN LIGHT, CEILING MTD <br />WALL WASHER, CEILING MTD <br />CEILING MTD LIGHT FIXTURE <br />WALL MTD LIGHT FIXTURE <br />WALL SCONCE <br />® <br />WALL PACK <br />SINGLE HEAD POLE MTD LIGHT FIXTURE <br />DUAL HEAD POLE MTD LIGHT FIXTURE <br />® <br />EXHAUST FAN <br />EMERGENCY WALLPACK <br />EXIT SIGN, CEILING/WALL MTD, SINGLE FACE <br />(ARROW INDICATES DIRECTION OF EGRESS) <br />EXIT SIGN, CEILING/WALL MTD, DOUBLE FACE <br />-� <br />(ARROW INDICATES DIRECTION OF EGRESS) <br />Q <br />EXIT SIGN W/ COMBINATION EMERGENCY LIGHT, <br />CEILING/WALL MTD, SINGLE FACE (ARROW <br />INDICATES DIRECTION OF EGRESS) <br />ONE -LINE SYMBOLS: <br />LOW VOLTAGE MOLDED CASE CIRCUIT cuIT BREAKER <br />T <br />(MCCB), THERMAL MAGNETIC, 3-POLE <br />AF - FRAME CURRENT RATING <br />AT - TRIP CURRENT SETTING <br />I <br />DISCONNECT SWITCH, NON -FUSED, <br />3-POLE UNLESS NOTED OTHERWISE <br />FUSED DISCONNECT SWITCH, <br />3-POLE UNLESS NOTED OTHERWISE <br />zoo <br />(200A SWITCH, 100A FUSES) <br />100 <br />FUSE <br />030 '°° <br />3-POLE UNLESS NOTED OTHERWISE <br />(100A HOLDER, 30A FUSES) <br />-I- <br />GROUND (GND) <br />BUS <br />ni <br />TRANSFORMER, DESCRIPTION AND RATING AS <br />NOTED <br />CURRENT TRANSFORMER <br />1 <br />(3) 3) <br />100:5 - CT RATIO <br />(3) - QUANTITY OF THREE REQUIRED <br />• - POLARITY <br />SPECIAL SYSTEMS SYMBOLS: <br />NOTE: UNLESS NOTED OTHERWISE, PROVIDE BACK BOX <br />AND 1" EMPTY CONDUIT STUBBED 6" INTO ACCESSIBLE <br />CEILING SPACE. FOR FLOOR BOXES, PROVIDE CONDUIT <br />EITHER IN SLAB <br />OR VIA FLOOR BELOW TO ACCESSIBLE <br />CEILING SPACE OF DEVICE LOCATION. COORDINATE WITH <br />LV CONTRACTOR FOR FINAL REQUIREMENTS. <br />`7X <br />TELEPHONE OUTLET, WALL MTD <br />1 TELE OUTLET, U.N.O. <br />X = NUMBER OF TELEPHONE PORTS <br />�Y <br />COMBINATION TELE/DATA OUTLET, WALL MTD <br />1 TELE / 1 DATA OUTLET, U.N.O. <br />Y = NUMBER OF DATA PORTS <br />XX <br />0 <br />COMBINATION TELE/DATA OUTLET, WALL MTD <br />1 TELE / 2 DATA OUTLETS, U.N.O. <br />X = NUMBER OF TELEPHONE PORTS <br />Y = NUMBER OF DATA PORTS <br />TELEPHONE OUTLET, FLOOR MTD <br />y <br />DATA OUTLET, FLOOR MTD <br />COMBINATION TELE/DATA OUTLET, FLOOR MTD <br />FA <br />WIRELESS ACCESS POINT, CEILING MTD <br />TELEPHONE BACKBOARD (TBB) <br />I-Q <br />INTERCOM OUTLET <br />E M <br />INTERCOM MASTER STATION <br />El <br />INTERCOM STATION <br />Tv <br />TELEVISION OUTLET, WALL MTD <br />Av <br />A/V OUTLET, WALL MTD <br />Tv <br />TELEVISION OUTLET, CEILING MTD <br />Av <br />A/V OUTLET, CEILING MTD <br />FO <br />VOLUME CONTROL, WALL MTD <br />FEI <br />MICROPHONE OUTLET, WALL MTD <br />AMP 1 <br />SOUND SYSTEM AMPLIFIER <br />F0 <br />SPEAKER, WALL MTD <br />SPEAKER, CEILING MTD <br />BELL <br />CHIME <br />GONG <br />E/ <br />BUZZER <br />-1 <br />HORN "H" OR SIREN "S" <br />aT <br />BELL RINGING TRANSFORMER <br />RELAY <br />BELL & BUZZER COMBINATION <br />❑° <br />ELECTRIC DOOR OPENER <br />w <br />LOW VOLTAGE TRANSFORMER <br />I-O <br />ANNUNCIATOR <br />SINGLE BUTTON PUSHBUTTON STATION <br />• <br />TWO -BUTTON PUSHBUTTON STATION <br />• • • <br />THREE -BUTTON PUSHBUTTON STATION <br />F(t)M <br />CLOCK <br />M = MASTER <br />DF = DOUBLE FACE <br />S = COMBINATION SPEAKER <br />sEc <br />SECURITY CONTROL PANEL <br />KP <br />KEYPAD <br />Dc <br />SECURITY ALARM INITIATING DEVICE <br />DOOR DC = CONTACT <br />GB = GLASS BREAK DETECTOR <br />MD = MOTION DETECTOR <br />VS = VIBRATION SENSOR <br />WC = WINDOW CONTACT <br />cR <br />ACCESS CONTROL DEVICE <br />CR = CARD READER <br />ES = ELECTRIC STRIKE <br />ML = MAGNETIC LOCK <br />RX = REQUEST EXIT PUSH BUTTON <br />::A <br />SECURITY CAMERA, WALL MTD <br />PTZ = PAN/TILT/ZOOM <br />BX = BOX <br />D = MINI DOME <br />BL = BULLET <br />WP = WEATHERPROOF <br />xO <br />SECURITY CAMERA, CEILING MTD <br />PTZ = PAN/TILT/ZOOM <br />BX = BOX <br />D = MINI DOME <br />BL = BULLET <br />WP = WEATHERPROOF <br />MJH <br />NORMAL / EMERGENCY CALL BUTTON <br />PUSH BUTTON <br />I-oT <br />THERMOSTAT, WALL MTD <br />0 <br />THERMOSTAT, CEILING MTD <br />FIRE ALARM SYMBOLS: <br />ED <br />MANUAL FIRE ALARM BOX <br />AUDIBLE NOTIFICATION DEVICE <br />x <br />xx <br />SS = BELL - SINGLE STROKE <br />T = BELL - TROUBLE <br />G = GONG <br />C = CHIME <br />Ejj <br />HORN, WALL MTD <br />F ' <br />HORN, CEILING MTD <br />EP <br />MINI HORN, WALL MTD <br />D FD <br />MINI HORN, CEILING MTD <br />04 <br />SPEAKER, WALL MTD <br />.5w <br />W = WATTAGE TAP <br />SPEAKER, CEILING MTD <br />.5w <br />W = WATTAGE TAP <br />FX <br />STROBE UNIT, WALL MTD <br />CD <br />CD = CANDELA RATING <br />x <br />STROBE UNIT, CEILING MTD <br />D <br />CD = CANDELA RATING <br />CD <br />EK <br />COMBINATION HORN / STROBE, WALL MTD <br />CD = CANDELA RATING <br />CD <br />NA <br />COMBINATION SPEAKER / STROBE, WALL MTD <br />1w <br />W = WATTAGE <br />CD = CANDELA RATING <br />CD <br />COMBINATION HORN / STROBE, CEILING MTD <br />CD = CANDELA RATING <br />CD <br />`M4 <br />COMBINATION SPEAKER / STROBE, CEILING MTD <br />1w <br />W = WATTAGE <br />CD = CANDELA RATING <br />Faa <br />FIRE ALARM ANNUNCIATOR <br />FACP <br />FIRE ALARM CONTROL PANEL <br />®RTS <br />REMOTE ALARM INDICATING & TEST STATION <br />0 <br />KNOX BOX <br />® <br />WATER FLOW SWITCH <br />El <br />NON -ADDRESSABLE OUTPUT RELAY <br />Ps <br />PRESSURE SWITCH <br />D <br />JUNCTION BOX <br />Dc7 <br />DOOR CLOSER <br />DH <br />DOOR HOLDER <br />vs <br />VALVE SUPERVISORY SWITCH (TAMPER SWITCH) <br />vs <br />VALVE W/ INTEGRAL SUPERVISORY SWITCH <br />(TAMPER SWITCH) <br />ABORT SWITCH <br />HEAT DETECTOR (THERMAL DETECTION) <br />HEAT DETECTOR - FIXED TEMPERATURE TYPE <br />j�jjF <br />CDR/F <br />HEAT DETECTOR - COMBINATION RATE OF <br />RISE / FIXED TEMPERATURE TYPE <br />sD <br />SMOKE DETECTOR <br />sD i <br />SMOKE DETECTOR - IONIZATION TYPE <br />sD P <br />SMOKE DETECTOR - PHOTOELECTRIC TYPE <br />sD <br />SMOKE DETECTOR, DUCT MTD <br />Oco <br />CARBON MONOXIDE DETECTOR <br />©co, <br />CARBON DIOXIDE DETECTOR <br />'Mr <br />END OF LINE RESISTOR <br />®x <br />FIRE SERVICE OR EMERGENCY PHONE STATION <br />A = ACCESSIBLE <br />H =HANDSET <br />J = JACK <br />SD M <br />DAMPER - MOTORIZED FIRE / SMOKE <br />RACEWAY SYMBOLS: <br />- UG - <br />UNDERGROUND POWER COMPANY SERVICE <br />FEEDER <br />- OH - <br />OVERHEAD POWER COMPANY SERVICE FEEDER <br />- TEL - <br />UNDERGROUND TELEPHONE SERVICE CONDUIT <br />- <br />CONDUIT BURIED <br />CONDUIT CONCEALED <br />- -- <br />CONDUIT EXPOSED <br />o- <br />CONDUIT UP <br />CONDUIT DOWN <br />p <br />CONDUIT SEAL -OFF <br />T <br />CONDUIT CAP <br />FV <br />CONDUIT TEE BODY <br />r <br />CONDUIT EL BODY <br />CONDUIT SLEEVE WITH BUSHINGS <br />Pa I <br />PULL BOX <br />GENERAL NOTES: <br />1. COMPLETE SYSTEM: FURNISH ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENTS AND SERVICES <br />REQUIRED TO CONSTRUCT, INSTALL, AND MODIFY THE ELECTRICAL SYSTEMS AS HEREIN SPECIFIED AND SHOWN ON THESE DRAWINGS FOR <br />A COMPLETE OPERATIONAL SYSTEM. COORDINATE WORK TO BE PERFORMED OR INSTALLED BY OTHERS AFFECTING THE ELECTRICAL <br />WORK AND FURNISH AND INSTALL ALL NECESSARY STEEL SHAPES, BLOCKING, ANCHORS, SLEEVES, HANGERS, ETC. FOR ATTACHING OR <br />CONNECTING ELECTRICAL WORK TO RELATED WORK OF OTHER TRADES. ALL ITEMS NOT SPECIFICALLY MENTIONED HEREIN, WHICH ARE <br />NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION, SHALL BE PROVIDED WITHOUT ADDITIONAL EXPENSE TO THE OWNER. <br />2. REGULATIONS: ALL ELECTRICAL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE LATEST ADOPTED NATIONAL ELECTRICAL <br />CODE (NEC) AND ALL OTHER APPLICABLE LOCAL BUILDING CODES, RULES, REGULATIONS AND AUTHORITIES HAVING JURISDICTION. <br />3. WORKMANSHIP: ALL WORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER SUBJECT TO THE APPROVAL OF THE OWNER OR <br />OWNER'S AUTHORIZED REPRESENTATIVE. RACEWAY, FIXTURES, AND WIRING DEVICES SHALL BE PROPERLY ALIGNED AND SUPPORTED. <br />RACEWAY SHALL BE GROUPED AND INSTALL IN RUNS WHICH ARE PARALLEL AND PERPENDICULAR WITH BUILDING LINES. <br />4. COORDINATION: PRIOR TO COMMENCEMENT OF WORK, EXAMINE ALL CONSTRUCTION DRAWINGS AND SPECIFICATIONS AND COORDINATE <br />WITH ALL OTHER TRADES IN ORDER TO BECOME FAMILIAR WITH ALL ASPECTS OF THE DESIGN AFFECTING THE ELECTRICAL WORK. REFER <br />TO ARCHITECTURAL DRAWINGS AND EQUIPMENT VENDOR CUT SHEETS FOR EQUIPMENT POWER/CONTROL REQUIREMENTS, CONNECTIONS, <br />MOUNTING HEIGHTS, AND LOCATIONS OF ALL NEW ELECTRICAL DEVICES. FIELD VERIFY EXACT NAMEPLATE DATA ON ALL EQUIPMENT <br />FURNISHED UNDER OTHER DIVISIONS AND/OR BY THE OWNER PRIOR TO THE INSTALLATION OF ELECTRICAL WORK AND MAKE ANY <br />ADJUSTMENTS TO OUTLETS, CONDUITS, WIRE, AND/OR CIRCUIT BREAKER RATINGS AS REQUIRED TO MATCH EQUIPMENT ACTUALLY <br />FURNISHED. FINAL LOCATION OF EQUIPMENT AND DEVICES TO BE COORDINATED WITH OWNER. <br />5. EXISTING CONDITIONS: SURVEY SITE OF WORK PRIOR TO SUBMITTING BID TO BECOME FULLY INFORMED OF ALL CONDITIONS THAT EFFECT <br />THE WORK AND COST THEREOF. CONSIDERATIONS WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDING OF THE AMOUNT OF <br />WORK TO BE PERFORMED. NOTIFY THE ARCHITECT AND/OR ENGINEER IN ADVANCE OF ANY DISCREPANCIES OR OMISSIONS. <br />6. PERMITS: OBTAIN ALL NECESSARY PERMITS, LICENSES, AND INSPECTIONS AS REQUIRED BY THE MUNICIPALITY AND UTILITY COMPANY. PAY <br />ALL ASSOCIATED FEES FOR PERMITS AND OTHER MUNICIPAL AND GOVERNING REQUIREMENTS. <br />7. UTILITIES: COORDINATE WITH POWER AND TELEPHONE COMPANIES FOR SERVICE REQUIREMENTS. NOTIFY UTILITIES OF COMMENCEMENT <br />OF WORK AND MAKE ALL ARRANGEMENTS FOR TEMPORARY SERVICES. THE COST FOR ALL WORK AND MATERIALS REQUIRED BY UTILITY <br />COMPANIES AND SET-UP OF SERVICE SHALL BE INCLUDED IN BID. <br />8. INTERRUPTION OF ELECTRICAL POWER: COORDINATE ALL WORK REQUIRING INTERRUPTION OF ELECTRICAL POWER WITH THE BUILDING <br />OWNER AND OBTAIN WRITTEN PERMISSION FROM THEBUILDING OWNER PRIOR TO SHUTTING DOWN POWER TO ANY SWITCHBOARD. <br />PROVIDE NOTICE TO ALL OTHER TRADES OF ALL SCHEDULED INTERRUPTIONS OF POWER. <br />9. PRODUCTS: ALL ELECTRICAL MATERIALS SHALL BE NEW EXCEPT WHERE SPECIFICALLY NOTED AS EXISTING TO BE REUSED. MATERIAL AND <br />METHODS OF INSTALLATION SHALL CONFORM TO THE STANDARDS OF UNDERWRITERS LABORATORIES, INC. (UL), ANSI, NFPA, ADA, AND ALL <br />APPLICABLE LOCAL ORDINANCES. DEFECTIVE EQUIPMENT AND/OR EQUIPMENT DAMAGED DURING INSTALLATION AND/OR TESTING SHALL BE <br />REPLACED OR REPAIRED IN A MANNER MEETING THE APPROVAL OF THE ARCHITECT AND THE ENGINEER. PROPOSED EQUIPMENT SHALL BE <br />NRTL LISTED, LABELED, OR APPROVED. <br />10. PENETRATIONS: COORDINATE FLOOR AND WALL PENETRATIONS WITH STRUCTURAL ENGINEER. ALL PENETRATIONS THROUGH FIRE -RATED <br />SLABS AND/OR PARTITIONS SHALL BE FIRE -PROOFED BY AN APPROVED METHOD TO THE SAME OR GREATER RATING THAN THAT OF THE <br />SLAB OR PARTITION. ALL PENETRATION SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. <br />11. FAULT CURRENT: VERIFY AVAILABLE FAULT CURRENT WITH POWER COMPANY AND MAKE EQUIPMENT PROVISIONS AS NECESSARY. <br />12. VOLTAGE DROP: INCREASE WIRE SIZES AS REQUIRED TO MAINTAIN VOLTAGE DROPS @ A MAXIMUM OF 3% FOR BRANCH CIRCUITS AND 2% <br />FOR FEEDERS. <br />13. WIRING: ALL CONDUCTORS CARRYING 50 VOLTS OR MORE SHALL BE MINIMUM #12 AWG, CU, UNO. PROVIDE TYPE THHN - THWN FOR ABOVE <br />GROUND AND TYPE THW OR XHHW FOR BELOW GROUND, COORDINATE INSULATION TYPES WITH ENVIRONMENTAL CONDITIONS, NEC <br />REQUIREMENTS, AND CONDUIT FILL REQUIREMENTS. CONDUCTORS #10 AND SMALLER SHALL BE SOLID, CONDUCTORS #8 AND LARGER <br />SHALL BE STRANDED. ALL CONDUCTOR SIZES ARE BASED ON COPPER WITH 60 C INSULATION FOR CIRCUITS RATED 100 A OR LESS AND 75 C <br />FOR CIRCUITS RATED MORE THAN 100 A. <br />14. COLOR CODING: FOR EXISTING WIRING SYSTEMS, COLOR CODING SHALL FOLLOW EXISTING SITE REQUIREMENTS. FOR NEW INSTALLATIONS <br />OR WHERE EXISTING INSTALLATIONS DO NOT HAVE A COLOR CODING CONVENTION, THE FOLLOWING SYSTEMS OF COLOR CODING SHALL <br />BE STRICTLY ADHERED TO AND FOLLOWED THROUGHOUT: <br />CONDUCTOR 480Y/277V 240V OR LESS <br />PHASE A: BROWN BLACK <br />PHASE B: ORANGE RED <br />PHASE C: YELLOW BLUE <br />NEUTRAL: GRAY WHITE <br />EQUIPMENT GROUND: GREEN GREEN <br />ISOLATED GROUND: --- GREEN W/ YELLOW STRIPE <br />15. GROUNDING: ALL CIRCUITS SHALL BE RUN WITH AN INSULATED GREEN COPPER GROUND WIRE SIZED PER NEC. USE OF CONDUIT AS A <br />GROUND IS UNACCEPTABLE. <br />16. CONDUIT: ALL WIRING SHALL BE INSTALLED IN CONDUIT, MINIMUM 1/2" FOR INDOOR AND 3/4" FOR OUTDOOR. EMT IS ACCEPTABLE WITH <br />COMPRESSION FITTINGS ONLY. MC IS ACCEPTABLE FOR FIXTURE WHIPS ONLY. ALL CONDUIT AND WIRING SHALL BE CONCEALED IN <br />CEILINGS AND/OR WALLS UNLESS SPECIFICALLY NOTED OTHERWISE. CHANNEL EXISTING WALLS WHERE REQUIRED. WHERE CONDUITS ARE <br />UNABLE TO BE CONCEALED, HARD PIPED CONDUIT SHALL BE USED AND PAINTED TO MATCH ADJOINING SURFACE. <br />17. ROUTING: CONDUIT ROUTING SHOWN IS SYMBOLIC AND DIAGRAMMATIC. INSTALL CONDUIT TO FIT ACTUAL FIELD CONDITIONS. <br />18. MODIFICATIONS TO EXISTING PANELBOARDS: PROVIDE NEW CIRCUIT BREAKERS AND/OR FUSED SWITCHES AS REQUIRED. NEW EQUIPMENT <br />SHALL MATCH EXISTING INSTALLED EQUIPMENT AND SHALL BE OF THE SAME MANUFACTURER AND TYPE AS SIMILAR EXISTING E (IUIPMENT. <br />INTERRUPTING RATING OF EQUIPMENT SHALL BE THE SAME AS OF THE EXISTING EQUIPMENT. <br />19. IDENTIFICATION: ALL ELECTRICAL DISTRIBUTION EQUIPMENT, TRANSFORMERS, PANELBOARDS, AND OTHER ENCLOSED EQUIPMENT SHALL <br />BE IDENTIFIED AS INDICATED IN THE CONTRACT DOCUMENTS. SAID IDENTIFICATION SHALL CONSIST OF PERMANENTLY ATTACHED <br />ENGRAVED LAMINATED PLASTIC NAMEPLATES. EACH 'BRANCH CIRCUIT OVER -CURRENT PROTECTION DEVICE SHALL BE IDENTIFIED BY <br />CIRCUIT NUMBER AND SCHEDULED INSIDE PANEL DOOR. EACH BRANCH CIRCUIT SPLICE OR TERMINATION SHALL BE IDENTIFIED BY PANEL <br />AND CIRCUIT DESIGNATION SHOWN ON THE JUNCTION OR OUTLET BOX, OR UPON INDIVIDUAL WIRES IN CASES WHERE MORE THAN ONE OF <br />EACH PHASE CONDUCTOR OCCUR. <br />20. SHOP DRAWINGS AND SUBMITTALS: SUBMIT MANUFACTURERS' STANDARD PRODUCT INFORMATION, PERFORMANCE SPECIFICATIONS, <br />PHYSICAL DIMENSIONS, AND OTHER INFORMATION NECESSARY FOR ENGINEER TO ENSURE COMPLIANCE WITH SPECIFICATIONS. SHOP <br />DRAWINGS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING AND INSTALLING ANY EQUIPMENT. <br />21. SUBSTITUTION AND ALTERATIONS: THERE SHALL BE NO DEVIATION FROM THE REQUIREMENTS HEREIN WITHOUT THE WRITTEN APPROVAL <br />OF THE ENGINEER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL COSTS INCURRED RESULTING FROM SUBSTITUTION OF <br />EQUIPMENT AS WELL AS THE PERFORMANCE AND SPACE REQUIREMENTS OF SUCH EQUIPMENT. <br />22. PROJECT RECORD DOCUMENTS: THE ELECTRICAL CONTRACTOR SHALL MAINTAIN AT THE SITE, FOR THE OWNER, ONE COPY OF ALL <br />DRAWINGS, ADDENDA, APPROVED SHOP DRAWINGS, REVISIONS AND OTHER MODIFICATIONS IN GOOD ORDER AND MARKED TO RECORD ALL <br />CHANGES MADE DURING CONSTRUCTION. THE SET OF DRAWINGS AND OTHER INFORMATION SHALL BE DELIVERED TO THE OWNER WITHIN <br />30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AND ONE COPY GIVEN TO THE ENGINEER UPON COMPLETION OF WORK. DRAWINGS <br />SHALL INCLUDE AT A MINIMUM: <br />A. A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND <br />B. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. <br />23. CERTIFICATES OF APPROVAL: ALL CERTIFICATES OF APPROVAL SHALL BE IN TRIPLICATE, DELIVERED TO THE ENGINEER AND BECOME THE <br />PROPERTY OF THE OWNER. <br />24. OPERATIONS AND MAINTENANCE MANUALS: PROVIDE OPERATING AND MAINTENANCE MANUALS TO THE BUILDING OWNER. THE MANUALS <br />SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: <br />A. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, <br />B. OPERATING MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED <br />ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. <br />C. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. <br />25. WARRANTY: THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT SHALL BE HANDED OVER IN PROPER WO <br />RKING ORKING ORDER. <br />ANY WORK OR MATERIALS WHICH DEVELOP DEFECTS, EXCEPT FROM ORDINARY WEAR AND TEAR, WITHIN ONE YEAR FROM THE DATE OF <br />FINAL ACCEPTANCE SHALL BE REPLACED WITHOUT CHARGE. BENEFICIAL USE SHALL NOT BE CONSTRUED AS FINAL ACCEPTANCE. THE <br />ELECTRICAL CONTRACTOR SHALL, DURING THE ONE YEAR GUARANTEE PERIOD, BE RESPONSIBLE FOR THE PROPER REPAIR AND <br />ADJUSTMENTS OF ALL ELECTRICAL SYSTEMS AND EQUIPMENT, APPARATUS, DEVICES, ETC. INSTALLED BY HIM, AND DO ALL WORK <br />NECESSARY TO ENSURE EFFICIENT AND PROPER FUNCTIONING. <br />ABBREVIATIONS: <br />A <br />AMPERE <br />HOA <br />AFF <br />ABOVE FINISHED FLOOR <br />IG <br />AFG <br />ABOVE FINISHED GRADE <br />JB <br />AHJ <br />AUTHORITY HAVING JURISDICTION <br />KVA <br />AFC <br />AVAILABLE FAULT CURRENT <br />KW <br />AIC <br />AMPERE INTERRUPTING CAPACITY <br />L.S.I.G. <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />BLDG <br />BUILDING <br />LTG <br />BRKR <br />BREAKER <br />MCA <br />C <br />CONDUIT <br />MCB <br />CKT <br />CIRCUIT <br />MCC <br />CLG <br />CEILING <br />MCCB <br />CT <br />CURRENT TRANSFORMER <br />MCP <br />CU <br />COPPER <br />MDP <br />CTR <br />CENTER <br />MFS <br />EA <br />EACH <br />MLO <br />EGC <br />EQUIPMENT GROUNDING CONDUCTOR <br />MOCP <br />EOL <br />ELECTRONIC OVERLOAD <br />MTD <br />FDR <br />FEEDER <br />MTS <br />FLA <br />FULL LOAD AMPS <br />N.C. <br />GEC <br />GROUNDING ELECTRODE CONDUCTOR <br />N.O. <br />GFI <br />GROUND FAULT INTERRUPTER <br />NTS <br />GND <br />GROUND <br />OCPD <br />GRS <br />GALVANIZED RIGID STEEL <br />OH <br />HAND -OFF -AUTO <br />P <br />POLE <br />ISOLATED GROUND <br />PH <br />PHASE <br />JUNCTION BOX <br />PNL <br />PANEL <br />KILOVOLT -AMPERE <br />PWR <br />POWER <br />KILOWATT <br />RECEP <br />RECEPTACLE <br />LONG, SHORT, INSTANTANEOUS, <br />RM <br />ROOM <br />GROUND FAULT TRIP <br />SW <br />SWITCH <br />LIGHTING <br />SWBR <br />SWITCHBOARD <br />MINIMUM CIRCUIT AMPS <br />SWGR <br />SWITCHGEAR <br />MAIN CIRCUIT BREAKER <br />TBB <br />TELECOM BACKBOARD <br />MOTOR CONTROL CENTER <br />TELE <br />TELEPHONE <br />MOLDED CASE CIRCUIT BREAKER <br />TYP <br />TYPICAL <br />MOTOR CIRCUIT PROTECTOR <br />UG <br />UNDERGROUND <br />MAIN DISTRIBUTION PANEL <br />LINO <br />UNLESS NOTED OTHERWISE <br />MAXIMUM FUSE SIZE <br />UPS <br />UNINTERRUPTIBLE <br />MAIN LUG ONLY <br />POWER SUPPLY <br />MAXIMUM OVERCURRENT PROTECTION <br />V <br />VOLT <br />MOUNTED <br />VIF <br />VERIFY IN FIELD <br />MANUAL TRANSFER SWITCH <br />W/ <br />WITH <br />NORMALLY CLOSED <br />W <br />WIRE <br />NORMALLY OPEN <br />WP <br />WEATHER PROOF <br />NOT TO SCALE <br />XFMR <br />TRANSFORMER <br />OVERCURRENT PROTECTION DEVICE <br />OVERHEAD <br />Bank of America <br />ADA- ZEPHYRHILLS <br />5632 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />SERIAL NUM./MANH. ID: FL2-019 <br />ON <br />Nelco Architecture, Inc. <br />a licensed affiliate <br />Florida Certificate of Authorization Number: AA26000525 <br />Architect: Client Representative: <br />Firm Name: NELSON Firm Name: ILL <br />Attn: Mark Schroeder Attn: David Berrios <br />T: 404.881.1811 Tel.: 813.245.0909 <br />e-mail: mschroeder@nelsononline.com e-mail: David.Berrios@am.jll.com <br />Engineer: <br />Firm Name: Infinity Engineering Group, LLC. <br />Attn: Brett Nevaril <br />1208 E Kennedy Blvd, STE 230 <br />Tampa, FL 33602 <br />T: 813.434-4770 <br />e-mail: brett@iegroup.net <br />Certification of Authorization #27889 <br />General Contractor: <br />Firm Name: Spartan Contracting Corporation <br />Attn: Scott Kramer <br />T: 813.481.5778 <br />e-mail: skramer@spartancc.com <br />IIssue Date & Issue Description By Check <br />1 04/23/18 Issue For Review KL CV <br />2 04/27/18 Issue For Permit KL CV <br />Seal/Signature <br />NISIT SAPPARKHAO, P.E. <br />FL' REG. NO. 64085 <br />w. <br />• No 6 085 <br />cc <br />r <br />:� STA E OF <br />o Q •• Al <br />40 <br />QI <br />DATE <br />Proiect Name <br />Bank of America <br />Zephyrhills <br />AWA upgraae <br />INELSON Project Number <br />18.00358.00110-65.439 <br />Description <br />ELECTRICAL GENERAL NOTES AND LEGEND <br />Scale & Sheet Number <br />AS INDICATED <br />E00m01 <br />