POWER SYMBOLS:
<br />HOMERUN CIRCUIT TO PANELBOARD
<br />CIRCUITING
<br />= TIME CONTROLLED
<br />= SWITCHED HOT
<br />= UNSWITCHED HOT
<br />= NEUTRAL
<br />=GROUND
<br />= ISOLATED GROUND
<br />20A, 125V, DUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD
<br />(�
<br />20A, 125V, DUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD ISOLATED GROUND
<br />20A, 125V, GFCI DUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD
<br />(�
<br />20A, 125V, SPLIT WIRED DUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD
<br />20A, 125V, QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD
<br />20A, 125V, QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD, ISOLATED GROUND
<br />20A, 125V, GFCI QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD
<br />20A, 125V, SPLIT WIRED QUADRUPLEX
<br />RECEPTACLE (NEMA 5-20R), WALL MTD
<br />(b
<br />20A, 125V, SIMPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD
<br />20A, 125V, SIMPLEX RECEPTACLE
<br />(NEMA 5-20R), WALL MTD ISOLATED GROUND
<br />POWER RECEPTACLE, FLOOR MTD
<br />(SEE SPECS OR NOTES)
<br />20A, 125V, DUPLEX RECEPTACLE
<br />(NEMA 5-20R), FLOOR MTD
<br />®
<br />20A, 125V, DUPLEX RECEPTACLE
<br />(NEMA 5-20R), FLOOR MTD ISOLATED GROUND
<br />®
<br />20A, 125V, GFCI DUPLEX RECEPTACLE
<br />(NEMA 5-20R), FLOOR MTD
<br />20A, 125V, QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), FLOOR MTD
<br />20A, 125V, QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), FLOOR MTD ISOLATED GROUND
<br />20A, 125V, GFCI QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), FLOOR MTD
<br />SPECIAL PURPOSE RECEPTACLE, FLOOR MTD
<br />(SEE EQUIPMENT SCHEDULE OR NOTES)
<br />0
<br />20A, 125V, DUPLEX RECEPTACLE
<br />(NEMA 5-20R), CEILING MTD
<br />(1)
<br />20A, 125V, DUPLEX RECEPTACLE
<br />(NEMA 5-20R), CEILING MTD ISOLATED GROUND
<br />U
<br />20A, 125V, GFCI DUPLEX RECEPTACLE
<br />(NEMA 5-20R), CEILING MTD
<br />0
<br />20A, 125V, QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), CEILING MTD
<br />0
<br />20A, 125V, QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), CEILING MTD ISOLATED GROUND
<br />0
<br />20A, 125V, GFCI QUADRUPLEX RECEPTACLE
<br />(NEMA 5-20R), CEILING MTD
<br />SPECIAL PURPOSE RECEPTACLE, WALL MTD
<br />(SEE EQUIPMENT SCHEDULE OR NOTES)
<br />D
<br />30A, 125 / 250V, DRYER RECEPTACLE
<br />(NEMA 14-30R), WALL MTD
<br />R
<br />50A, 125 / 250V, RANGE RECEPTACLE
<br />(NEMA 14-50R), WALL MTD
<br />6 A
<br />(ljl�
<br />60A, 480V, 3PH, WELDING RECEPTACLE, WALL
<br />MTD
<br />DROP CORD (SEE SPECS OR NOTES)
<br />(�O
<br />POWER POLE (SEE SPECS OR NOTES)
<br />®
<br />RECEPTACLE RACEWAY / PLUG MOLD
<br />H
<br />JUNCTION BOX, WALL MTD
<br />0
<br />JUNCTION BOX
<br />JUNCTION BOX, FLOOR MTD
<br />JUNCTION BOX, EXPLOSION PROOF
<br />3NF;L'1
<br />SAFETY SWITCH, 30A, 3-POLE, NON -FUSED
<br />3i3L (; -�:: I
<br />SAFETY SWITCH, 30A, 3-POLE, FUSED @ 20A
<br />CECI
<br />STARTER OR MOTOR CONTROLLER
<br />LCEO
<br />STARTER, COMBINATION W/ DISC. SWITCH
<br />�T
<br />TRANSFORMER
<br />ELECTRICAL PANEL / ENCLOSURE AS NOTED ON
<br />PLAN DRAWINGS, SURFACE/RECESSED MTD
<br />I�
<br />208Y/120V PANELBOARD, SURFACE/RECESSED
<br />MTD
<br />[;-mE .fir
<br />208Y/120V LIGHTING PANELBOARD,
<br />SURFACE/RECESSED MTD
<br />480Y/277V PANELBOARD, SURFACE MTD
<br />ELECTRIC UTILITY METER
<br />LIGHTING SYMBOLS:
<br />NOTE: REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE
<br />TYPES. REFER TO SENSOR SCHEDULE FOR SENSOR TYPES.
<br />REFER TO PLAN DRAWINGS FOR ADDITIONAL SYMBOLS.
<br />A:
<br />CAPITAL LETTER ADJACENT TO FIXTURE = TYPE
<br />a:
<br />LOWERCASE LETTER = SWITCHING GROUP
<br />EM:
<br />EMERGENCY LIGHTING
<br />NL:
<br />NIGHT LIGHTING (UNSWITCHED FIXTURE)
<br />xx
<br />SWITCH, 20A, 120/277V, TOGGLE TYPE, U.N.O.
<br />a,b,c,... =SWITCHING GROUP
<br />BLANK =SINGLE POLE
<br />2 =DOUBLE POLE
<br />3 =THREE-WAY
<br />4 =FOUR-WAY
<br />D =DIMMER SWITCH
<br />K =SINGLE POLE KEY OPERATED
<br />L = LOW VOLTAGE
<br />M =MOTOR RATED
<br />P =SINGLE POLE W/ PILOT LIGHT
<br />RC = REMOTE CONTROL
<br />T =TIMER OPERATED SWITCH
<br />ePc
<br />AUTOMATIC EMERGENCY POWER TRANSFER
<br />CONTROLLER
<br />os
<br />OCCUPANCY SENSOR, CEILING MTD
<br />xx
<br />Ds xx
<br />DAYLIGHT SENSOR, CEILING MTD
<br />Rc xx
<br />ROOM CONTROLLER
<br />os
<br />OCCUPANCY SENSOR, WALL MTD
<br />Pc
<br />PHOTOCELL
<br />�c
<br />LIGHTING CONTACTOR
<br />Tc
<br />TIME CLOCK
<br />2'X4' LAY -IN TROFFER
<br />®
<br />2'X4' LAY -IN TROFFER, NIGHT LIGHT
<br />2'X4' LAY -IN TROFFER, EMERGENCY LIGHT
<br />®
<br />2'X2' LAY -IN TROFFER
<br />®
<br />1'X4' LAY -IN TROFFER
<br />fo---i
<br />STRIP/CHANNEL FIXTURE
<br />--
<br />TRACK LIGHTING W/ DIRECTIONAL HEADS
<br />®
<br />DOWN LIGHT, CEILING MTD
<br />WALL WASHER, CEILING MTD
<br />CEILING MTD LIGHT FIXTURE
<br />WALL MTD LIGHT FIXTURE
<br />WALL SCONCE
<br />®
<br />WALL PACK
<br />SINGLE HEAD POLE MTD LIGHT FIXTURE
<br />DUAL HEAD POLE MTD LIGHT FIXTURE
<br />®
<br />EXHAUST FAN
<br />EMERGENCY WALLPACK
<br />EXIT SIGN, CEILING/WALL MTD, SINGLE FACE
<br />(ARROW INDICATES DIRECTION OF EGRESS)
<br />EXIT SIGN, CEILING/WALL MTD, DOUBLE FACE
<br />-�
<br />(ARROW INDICATES DIRECTION OF EGRESS)
<br />Q
<br />EXIT SIGN W/ COMBINATION EMERGENCY LIGHT,
<br />CEILING/WALL MTD, SINGLE FACE (ARROW
<br />INDICATES DIRECTION OF EGRESS)
<br />ONE -LINE SYMBOLS:
<br />LOW VOLTAGE MOLDED CASE CIRCUIT cuIT BREAKER
<br />T
<br />(MCCB), THERMAL MAGNETIC, 3-POLE
<br />AF - FRAME CURRENT RATING
<br />AT - TRIP CURRENT SETTING
<br />I
<br />DISCONNECT SWITCH, NON -FUSED,
<br />3-POLE UNLESS NOTED OTHERWISE
<br />FUSED DISCONNECT SWITCH,
<br />3-POLE UNLESS NOTED OTHERWISE
<br />zoo
<br />(200A SWITCH, 100A FUSES)
<br />100
<br />FUSE
<br />030 '°°
<br />3-POLE UNLESS NOTED OTHERWISE
<br />(100A HOLDER, 30A FUSES)
<br />-I-
<br />GROUND (GND)
<br />BUS
<br />ni
<br />TRANSFORMER, DESCRIPTION AND RATING AS
<br />NOTED
<br />CURRENT TRANSFORMER
<br />1
<br />(3) 3)
<br />100:5 - CT RATIO
<br />(3) - QUANTITY OF THREE REQUIRED
<br />• - POLARITY
<br />SPECIAL SYSTEMS SYMBOLS:
<br />NOTE: UNLESS NOTED OTHERWISE, PROVIDE BACK BOX
<br />AND 1" EMPTY CONDUIT STUBBED 6" INTO ACCESSIBLE
<br />CEILING SPACE. FOR FLOOR BOXES, PROVIDE CONDUIT
<br />EITHER IN SLAB
<br />OR VIA FLOOR BELOW TO ACCESSIBLE
<br />CEILING SPACE OF DEVICE LOCATION. COORDINATE WITH
<br />LV CONTRACTOR FOR FINAL REQUIREMENTS.
<br />`7X
<br />TELEPHONE OUTLET, WALL MTD
<br />1 TELE OUTLET, U.N.O.
<br />X = NUMBER OF TELEPHONE PORTS
<br />�Y
<br />COMBINATION TELE/DATA OUTLET, WALL MTD
<br />1 TELE / 1 DATA OUTLET, U.N.O.
<br />Y = NUMBER OF DATA PORTS
<br />XX
<br />0
<br />COMBINATION TELE/DATA OUTLET, WALL MTD
<br />1 TELE / 2 DATA OUTLETS, U.N.O.
<br />X = NUMBER OF TELEPHONE PORTS
<br />Y = NUMBER OF DATA PORTS
<br />TELEPHONE OUTLET, FLOOR MTD
<br />y
<br />DATA OUTLET, FLOOR MTD
<br />COMBINATION TELE/DATA OUTLET, FLOOR MTD
<br />FA
<br />WIRELESS ACCESS POINT, CEILING MTD
<br />TELEPHONE BACKBOARD (TBB)
<br />I-Q
<br />INTERCOM OUTLET
<br />E M
<br />INTERCOM MASTER STATION
<br />El
<br />INTERCOM STATION
<br />Tv
<br />TELEVISION OUTLET, WALL MTD
<br />Av
<br />A/V OUTLET, WALL MTD
<br />Tv
<br />TELEVISION OUTLET, CEILING MTD
<br />Av
<br />A/V OUTLET, CEILING MTD
<br />FO
<br />VOLUME CONTROL, WALL MTD
<br />FEI
<br />MICROPHONE OUTLET, WALL MTD
<br />AMP 1
<br />SOUND SYSTEM AMPLIFIER
<br />F0
<br />SPEAKER, WALL MTD
<br />SPEAKER, CEILING MTD
<br />BELL
<br />CHIME
<br />GONG
<br />E/
<br />BUZZER
<br />-1
<br />HORN "H" OR SIREN "S"
<br />aT
<br />BELL RINGING TRANSFORMER
<br />RELAY
<br />BELL & BUZZER COMBINATION
<br />❑°
<br />ELECTRIC DOOR OPENER
<br />w
<br />LOW VOLTAGE TRANSFORMER
<br />I-O
<br />ANNUNCIATOR
<br />SINGLE BUTTON PUSHBUTTON STATION
<br />•
<br />TWO -BUTTON PUSHBUTTON STATION
<br />• • •
<br />THREE -BUTTON PUSHBUTTON STATION
<br />F(t)M
<br />CLOCK
<br />M = MASTER
<br />DF = DOUBLE FACE
<br />S = COMBINATION SPEAKER
<br />sEc
<br />SECURITY CONTROL PANEL
<br />KP
<br />KEYPAD
<br />Dc
<br />SECURITY ALARM INITIATING DEVICE
<br />DOOR DC = CONTACT
<br />GB = GLASS BREAK DETECTOR
<br />MD = MOTION DETECTOR
<br />VS = VIBRATION SENSOR
<br />WC = WINDOW CONTACT
<br />cR
<br />ACCESS CONTROL DEVICE
<br />CR = CARD READER
<br />ES = ELECTRIC STRIKE
<br />ML = MAGNETIC LOCK
<br />RX = REQUEST EXIT PUSH BUTTON
<br />::A
<br />SECURITY CAMERA, WALL MTD
<br />PTZ = PAN/TILT/ZOOM
<br />BX = BOX
<br />D = MINI DOME
<br />BL = BULLET
<br />WP = WEATHERPROOF
<br />xO
<br />SECURITY CAMERA, CEILING MTD
<br />PTZ = PAN/TILT/ZOOM
<br />BX = BOX
<br />D = MINI DOME
<br />BL = BULLET
<br />WP = WEATHERPROOF
<br />MJH
<br />NORMAL / EMERGENCY CALL BUTTON
<br />PUSH BUTTON
<br />I-oT
<br />THERMOSTAT, WALL MTD
<br />0
<br />THERMOSTAT, CEILING MTD
<br />FIRE ALARM SYMBOLS:
<br />ED
<br />MANUAL FIRE ALARM BOX
<br />AUDIBLE NOTIFICATION DEVICE
<br />x
<br />xx
<br />SS = BELL - SINGLE STROKE
<br />T = BELL - TROUBLE
<br />G = GONG
<br />C = CHIME
<br />Ejj
<br />HORN, WALL MTD
<br />F '
<br />HORN, CEILING MTD
<br />EP
<br />MINI HORN, WALL MTD
<br />D FD
<br />MINI HORN, CEILING MTD
<br />04
<br />SPEAKER, WALL MTD
<br />.5w
<br />W = WATTAGE TAP
<br />SPEAKER, CEILING MTD
<br />.5w
<br />W = WATTAGE TAP
<br />FX
<br />STROBE UNIT, WALL MTD
<br />CD
<br />CD = CANDELA RATING
<br />x
<br />STROBE UNIT, CEILING MTD
<br />D
<br />CD = CANDELA RATING
<br />CD
<br />EK
<br />COMBINATION HORN / STROBE, WALL MTD
<br />CD = CANDELA RATING
<br />CD
<br />NA
<br />COMBINATION SPEAKER / STROBE, WALL MTD
<br />1w
<br />W = WATTAGE
<br />CD = CANDELA RATING
<br />CD
<br />COMBINATION HORN / STROBE, CEILING MTD
<br />CD = CANDELA RATING
<br />CD
<br />`M4
<br />COMBINATION SPEAKER / STROBE, CEILING MTD
<br />1w
<br />W = WATTAGE
<br />CD = CANDELA RATING
<br />Faa
<br />FIRE ALARM ANNUNCIATOR
<br />FACP
<br />FIRE ALARM CONTROL PANEL
<br />®RTS
<br />REMOTE ALARM INDICATING & TEST STATION
<br />0
<br />KNOX BOX
<br />®
<br />WATER FLOW SWITCH
<br />El
<br />NON -ADDRESSABLE OUTPUT RELAY
<br />Ps
<br />PRESSURE SWITCH
<br />D
<br />JUNCTION BOX
<br />Dc7
<br />DOOR CLOSER
<br />DH
<br />DOOR HOLDER
<br />vs
<br />VALVE SUPERVISORY SWITCH (TAMPER SWITCH)
<br />vs
<br />VALVE W/ INTEGRAL SUPERVISORY SWITCH
<br />(TAMPER SWITCH)
<br />ABORT SWITCH
<br />HEAT DETECTOR (THERMAL DETECTION)
<br />HEAT DETECTOR - FIXED TEMPERATURE TYPE
<br />j�jjF
<br />CDR/F
<br />HEAT DETECTOR - COMBINATION RATE OF
<br />RISE / FIXED TEMPERATURE TYPE
<br />sD
<br />SMOKE DETECTOR
<br />sD i
<br />SMOKE DETECTOR - IONIZATION TYPE
<br />sD P
<br />SMOKE DETECTOR - PHOTOELECTRIC TYPE
<br />sD
<br />SMOKE DETECTOR, DUCT MTD
<br />Oco
<br />CARBON MONOXIDE DETECTOR
<br />©co,
<br />CARBON DIOXIDE DETECTOR
<br />'Mr
<br />END OF LINE RESISTOR
<br />®x
<br />FIRE SERVICE OR EMERGENCY PHONE STATION
<br />A = ACCESSIBLE
<br />H =HANDSET
<br />J = JACK
<br />SD M
<br />DAMPER - MOTORIZED FIRE / SMOKE
<br />RACEWAY SYMBOLS:
<br />- UG -
<br />UNDERGROUND POWER COMPANY SERVICE
<br />FEEDER
<br />- OH -
<br />OVERHEAD POWER COMPANY SERVICE FEEDER
<br />- TEL -
<br />UNDERGROUND TELEPHONE SERVICE CONDUIT
<br />-
<br />CONDUIT BURIED
<br />CONDUIT CONCEALED
<br />- --
<br />CONDUIT EXPOSED
<br />o-
<br />CONDUIT UP
<br />CONDUIT DOWN
<br />p
<br />CONDUIT SEAL -OFF
<br />T
<br />CONDUIT CAP
<br />FV
<br />CONDUIT TEE BODY
<br />r
<br />CONDUIT EL BODY
<br />CONDUIT SLEEVE WITH BUSHINGS
<br />Pa I
<br />PULL BOX
<br />GENERAL NOTES:
<br />1. COMPLETE SYSTEM: FURNISH ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENTS AND SERVICES
<br />REQUIRED TO CONSTRUCT, INSTALL, AND MODIFY THE ELECTRICAL SYSTEMS AS HEREIN SPECIFIED AND SHOWN ON THESE DRAWINGS FOR
<br />A COMPLETE OPERATIONAL SYSTEM. COORDINATE WORK TO BE PERFORMED OR INSTALLED BY OTHERS AFFECTING THE ELECTRICAL
<br />WORK AND FURNISH AND INSTALL ALL NECESSARY STEEL SHAPES, BLOCKING, ANCHORS, SLEEVES, HANGERS, ETC. FOR ATTACHING OR
<br />CONNECTING ELECTRICAL WORK TO RELATED WORK OF OTHER TRADES. ALL ITEMS NOT SPECIFICALLY MENTIONED HEREIN, WHICH ARE
<br />NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION, SHALL BE PROVIDED WITHOUT ADDITIONAL EXPENSE TO THE OWNER.
<br />2. REGULATIONS: ALL ELECTRICAL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE LATEST ADOPTED NATIONAL ELECTRICAL
<br />CODE (NEC) AND ALL OTHER APPLICABLE LOCAL BUILDING CODES, RULES, REGULATIONS AND AUTHORITIES HAVING JURISDICTION.
<br />3. WORKMANSHIP: ALL WORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER SUBJECT TO THE APPROVAL OF THE OWNER OR
<br />OWNER'S AUTHORIZED REPRESENTATIVE. RACEWAY, FIXTURES, AND WIRING DEVICES SHALL BE PROPERLY ALIGNED AND SUPPORTED.
<br />RACEWAY SHALL BE GROUPED AND INSTALL IN RUNS WHICH ARE PARALLEL AND PERPENDICULAR WITH BUILDING LINES.
<br />4. COORDINATION: PRIOR TO COMMENCEMENT OF WORK, EXAMINE ALL CONSTRUCTION DRAWINGS AND SPECIFICATIONS AND COORDINATE
<br />WITH ALL OTHER TRADES IN ORDER TO BECOME FAMILIAR WITH ALL ASPECTS OF THE DESIGN AFFECTING THE ELECTRICAL WORK. REFER
<br />TO ARCHITECTURAL DRAWINGS AND EQUIPMENT VENDOR CUT SHEETS FOR EQUIPMENT POWER/CONTROL REQUIREMENTS, CONNECTIONS,
<br />MOUNTING HEIGHTS, AND LOCATIONS OF ALL NEW ELECTRICAL DEVICES. FIELD VERIFY EXACT NAMEPLATE DATA ON ALL EQUIPMENT
<br />FURNISHED UNDER OTHER DIVISIONS AND/OR BY THE OWNER PRIOR TO THE INSTALLATION OF ELECTRICAL WORK AND MAKE ANY
<br />ADJUSTMENTS TO OUTLETS, CONDUITS, WIRE, AND/OR CIRCUIT BREAKER RATINGS AS REQUIRED TO MATCH EQUIPMENT ACTUALLY
<br />FURNISHED. FINAL LOCATION OF EQUIPMENT AND DEVICES TO BE COORDINATED WITH OWNER.
<br />5. EXISTING CONDITIONS: SURVEY SITE OF WORK PRIOR TO SUBMITTING BID TO BECOME FULLY INFORMED OF ALL CONDITIONS THAT EFFECT
<br />THE WORK AND COST THEREOF. CONSIDERATIONS WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDING OF THE AMOUNT OF
<br />WORK TO BE PERFORMED. NOTIFY THE ARCHITECT AND/OR ENGINEER IN ADVANCE OF ANY DISCREPANCIES OR OMISSIONS.
<br />6. PERMITS: OBTAIN ALL NECESSARY PERMITS, LICENSES, AND INSPECTIONS AS REQUIRED BY THE MUNICIPALITY AND UTILITY COMPANY. PAY
<br />ALL ASSOCIATED FEES FOR PERMITS AND OTHER MUNICIPAL AND GOVERNING REQUIREMENTS.
<br />7. UTILITIES: COORDINATE WITH POWER AND TELEPHONE COMPANIES FOR SERVICE REQUIREMENTS. NOTIFY UTILITIES OF COMMENCEMENT
<br />OF WORK AND MAKE ALL ARRANGEMENTS FOR TEMPORARY SERVICES. THE COST FOR ALL WORK AND MATERIALS REQUIRED BY UTILITY
<br />COMPANIES AND SET-UP OF SERVICE SHALL BE INCLUDED IN BID.
<br />8. INTERRUPTION OF ELECTRICAL POWER: COORDINATE ALL WORK REQUIRING INTERRUPTION OF ELECTRICAL POWER WITH THE BUILDING
<br />OWNER AND OBTAIN WRITTEN PERMISSION FROM THEBUILDING OWNER PRIOR TO SHUTTING DOWN POWER TO ANY SWITCHBOARD.
<br />PROVIDE NOTICE TO ALL OTHER TRADES OF ALL SCHEDULED INTERRUPTIONS OF POWER.
<br />9. PRODUCTS: ALL ELECTRICAL MATERIALS SHALL BE NEW EXCEPT WHERE SPECIFICALLY NOTED AS EXISTING TO BE REUSED. MATERIAL AND
<br />METHODS OF INSTALLATION SHALL CONFORM TO THE STANDARDS OF UNDERWRITERS LABORATORIES, INC. (UL), ANSI, NFPA, ADA, AND ALL
<br />APPLICABLE LOCAL ORDINANCES. DEFECTIVE EQUIPMENT AND/OR EQUIPMENT DAMAGED DURING INSTALLATION AND/OR TESTING SHALL BE
<br />REPLACED OR REPAIRED IN A MANNER MEETING THE APPROVAL OF THE ARCHITECT AND THE ENGINEER. PROPOSED EQUIPMENT SHALL BE
<br />NRTL LISTED, LABELED, OR APPROVED.
<br />10. PENETRATIONS: COORDINATE FLOOR AND WALL PENETRATIONS WITH STRUCTURAL ENGINEER. ALL PENETRATIONS THROUGH FIRE -RATED
<br />SLABS AND/OR PARTITIONS SHALL BE FIRE -PROOFED BY AN APPROVED METHOD TO THE SAME OR GREATER RATING THAN THAT OF THE
<br />SLAB OR PARTITION. ALL PENETRATION SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS.
<br />11. FAULT CURRENT: VERIFY AVAILABLE FAULT CURRENT WITH POWER COMPANY AND MAKE EQUIPMENT PROVISIONS AS NECESSARY.
<br />12. VOLTAGE DROP: INCREASE WIRE SIZES AS REQUIRED TO MAINTAIN VOLTAGE DROPS @ A MAXIMUM OF 3% FOR BRANCH CIRCUITS AND 2%
<br />FOR FEEDERS.
<br />13. WIRING: ALL CONDUCTORS CARRYING 50 VOLTS OR MORE SHALL BE MINIMUM #12 AWG, CU, UNO. PROVIDE TYPE THHN - THWN FOR ABOVE
<br />GROUND AND TYPE THW OR XHHW FOR BELOW GROUND, COORDINATE INSULATION TYPES WITH ENVIRONMENTAL CONDITIONS, NEC
<br />REQUIREMENTS, AND CONDUIT FILL REQUIREMENTS. CONDUCTORS #10 AND SMALLER SHALL BE SOLID, CONDUCTORS #8 AND LARGER
<br />SHALL BE STRANDED. ALL CONDUCTOR SIZES ARE BASED ON COPPER WITH 60 C INSULATION FOR CIRCUITS RATED 100 A OR LESS AND 75 C
<br />FOR CIRCUITS RATED MORE THAN 100 A.
<br />14. COLOR CODING: FOR EXISTING WIRING SYSTEMS, COLOR CODING SHALL FOLLOW EXISTING SITE REQUIREMENTS. FOR NEW INSTALLATIONS
<br />OR WHERE EXISTING INSTALLATIONS DO NOT HAVE A COLOR CODING CONVENTION, THE FOLLOWING SYSTEMS OF COLOR CODING SHALL
<br />BE STRICTLY ADHERED TO AND FOLLOWED THROUGHOUT:
<br />CONDUCTOR 480Y/277V 240V OR LESS
<br />PHASE A: BROWN BLACK
<br />PHASE B: ORANGE RED
<br />PHASE C: YELLOW BLUE
<br />NEUTRAL: GRAY WHITE
<br />EQUIPMENT GROUND: GREEN GREEN
<br />ISOLATED GROUND: --- GREEN W/ YELLOW STRIPE
<br />15. GROUNDING: ALL CIRCUITS SHALL BE RUN WITH AN INSULATED GREEN COPPER GROUND WIRE SIZED PER NEC. USE OF CONDUIT AS A
<br />GROUND IS UNACCEPTABLE.
<br />16. CONDUIT: ALL WIRING SHALL BE INSTALLED IN CONDUIT, MINIMUM 1/2" FOR INDOOR AND 3/4" FOR OUTDOOR. EMT IS ACCEPTABLE WITH
<br />COMPRESSION FITTINGS ONLY. MC IS ACCEPTABLE FOR FIXTURE WHIPS ONLY. ALL CONDUIT AND WIRING SHALL BE CONCEALED IN
<br />CEILINGS AND/OR WALLS UNLESS SPECIFICALLY NOTED OTHERWISE. CHANNEL EXISTING WALLS WHERE REQUIRED. WHERE CONDUITS ARE
<br />UNABLE TO BE CONCEALED, HARD PIPED CONDUIT SHALL BE USED AND PAINTED TO MATCH ADJOINING SURFACE.
<br />17. ROUTING: CONDUIT ROUTING SHOWN IS SYMBOLIC AND DIAGRAMMATIC. INSTALL CONDUIT TO FIT ACTUAL FIELD CONDITIONS.
<br />18. MODIFICATIONS TO EXISTING PANELBOARDS: PROVIDE NEW CIRCUIT BREAKERS AND/OR FUSED SWITCHES AS REQUIRED. NEW EQUIPMENT
<br />SHALL MATCH EXISTING INSTALLED EQUIPMENT AND SHALL BE OF THE SAME MANUFACTURER AND TYPE AS SIMILAR EXISTING E (IUIPMENT.
<br />INTERRUPTING RATING OF EQUIPMENT SHALL BE THE SAME AS OF THE EXISTING EQUIPMENT.
<br />19. IDENTIFICATION: ALL ELECTRICAL DISTRIBUTION EQUIPMENT, TRANSFORMERS, PANELBOARDS, AND OTHER ENCLOSED EQUIPMENT SHALL
<br />BE IDENTIFIED AS INDICATED IN THE CONTRACT DOCUMENTS. SAID IDENTIFICATION SHALL CONSIST OF PERMANENTLY ATTACHED
<br />ENGRAVED LAMINATED PLASTIC NAMEPLATES. EACH 'BRANCH CIRCUIT OVER -CURRENT PROTECTION DEVICE SHALL BE IDENTIFIED BY
<br />CIRCUIT NUMBER AND SCHEDULED INSIDE PANEL DOOR. EACH BRANCH CIRCUIT SPLICE OR TERMINATION SHALL BE IDENTIFIED BY PANEL
<br />AND CIRCUIT DESIGNATION SHOWN ON THE JUNCTION OR OUTLET BOX, OR UPON INDIVIDUAL WIRES IN CASES WHERE MORE THAN ONE OF
<br />EACH PHASE CONDUCTOR OCCUR.
<br />20. SHOP DRAWINGS AND SUBMITTALS: SUBMIT MANUFACTURERS' STANDARD PRODUCT INFORMATION, PERFORMANCE SPECIFICATIONS,
<br />PHYSICAL DIMENSIONS, AND OTHER INFORMATION NECESSARY FOR ENGINEER TO ENSURE COMPLIANCE WITH SPECIFICATIONS. SHOP
<br />DRAWINGS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING AND INSTALLING ANY EQUIPMENT.
<br />21. SUBSTITUTION AND ALTERATIONS: THERE SHALL BE NO DEVIATION FROM THE REQUIREMENTS HEREIN WITHOUT THE WRITTEN APPROVAL
<br />OF THE ENGINEER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL COSTS INCURRED RESULTING FROM SUBSTITUTION OF
<br />EQUIPMENT AS WELL AS THE PERFORMANCE AND SPACE REQUIREMENTS OF SUCH EQUIPMENT.
<br />22. PROJECT RECORD DOCUMENTS: THE ELECTRICAL CONTRACTOR SHALL MAINTAIN AT THE SITE, FOR THE OWNER, ONE COPY OF ALL
<br />DRAWINGS, ADDENDA, APPROVED SHOP DRAWINGS, REVISIONS AND OTHER MODIFICATIONS IN GOOD ORDER AND MARKED TO RECORD ALL
<br />CHANGES MADE DURING CONSTRUCTION. THE SET OF DRAWINGS AND OTHER INFORMATION SHALL BE DELIVERED TO THE OWNER WITHIN
<br />30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AND ONE COPY GIVEN TO THE ENGINEER UPON COMPLETION OF WORK. DRAWINGS
<br />SHALL INCLUDE AT A MINIMUM:
<br />A. A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND
<br />B. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION.
<br />23. CERTIFICATES OF APPROVAL: ALL CERTIFICATES OF APPROVAL SHALL BE IN TRIPLICATE, DELIVERED TO THE ENGINEER AND BECOME THE
<br />PROPERTY OF THE OWNER.
<br />24. OPERATIONS AND MAINTENANCE MANUALS: PROVIDE OPERATING AND MAINTENANCE MANUALS TO THE BUILDING OWNER. THE MANUALS
<br />SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING:
<br />A. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE,
<br />B. OPERATING MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED
<br />ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED.
<br />C. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY.
<br />25. WARRANTY: THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT SHALL BE HANDED OVER IN PROPER WO
<br />RKING ORKING ORDER.
<br />ANY WORK OR MATERIALS WHICH DEVELOP DEFECTS, EXCEPT FROM ORDINARY WEAR AND TEAR, WITHIN ONE YEAR FROM THE DATE OF
<br />FINAL ACCEPTANCE SHALL BE REPLACED WITHOUT CHARGE. BENEFICIAL USE SHALL NOT BE CONSTRUED AS FINAL ACCEPTANCE. THE
<br />ELECTRICAL CONTRACTOR SHALL, DURING THE ONE YEAR GUARANTEE PERIOD, BE RESPONSIBLE FOR THE PROPER REPAIR AND
<br />ADJUSTMENTS OF ALL ELECTRICAL SYSTEMS AND EQUIPMENT, APPARATUS, DEVICES, ETC. INSTALLED BY HIM, AND DO ALL WORK
<br />NECESSARY TO ENSURE EFFICIENT AND PROPER FUNCTIONING.
<br />ABBREVIATIONS:
<br />A
<br />AMPERE
<br />HOA
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />IG
<br />AFG
<br />ABOVE FINISHED GRADE
<br />JB
<br />AHJ
<br />AUTHORITY HAVING JURISDICTION
<br />KVA
<br />AFC
<br />AVAILABLE FAULT CURRENT
<br />KW
<br />AIC
<br />AMPERE INTERRUPTING CAPACITY
<br />L.S.I.G.
<br />ATS
<br />AUTOMATIC TRANSFER SWITCH
<br />BLDG
<br />BUILDING
<br />LTG
<br />BRKR
<br />BREAKER
<br />MCA
<br />C
<br />CONDUIT
<br />MCB
<br />CKT
<br />CIRCUIT
<br />MCC
<br />CLG
<br />CEILING
<br />MCCB
<br />CT
<br />CURRENT TRANSFORMER
<br />MCP
<br />CU
<br />COPPER
<br />MDP
<br />CTR
<br />CENTER
<br />MFS
<br />EA
<br />EACH
<br />MLO
<br />EGC
<br />EQUIPMENT GROUNDING CONDUCTOR
<br />MOCP
<br />EOL
<br />ELECTRONIC OVERLOAD
<br />MTD
<br />FDR
<br />FEEDER
<br />MTS
<br />FLA
<br />FULL LOAD AMPS
<br />N.C.
<br />GEC
<br />GROUNDING ELECTRODE CONDUCTOR
<br />N.O.
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />NTS
<br />GND
<br />GROUND
<br />OCPD
<br />GRS
<br />GALVANIZED RIGID STEEL
<br />OH
<br />HAND -OFF -AUTO
<br />P
<br />POLE
<br />ISOLATED GROUND
<br />PH
<br />PHASE
<br />JUNCTION BOX
<br />PNL
<br />PANEL
<br />KILOVOLT -AMPERE
<br />PWR
<br />POWER
<br />KILOWATT
<br />RECEP
<br />RECEPTACLE
<br />LONG, SHORT, INSTANTANEOUS,
<br />RM
<br />ROOM
<br />GROUND FAULT TRIP
<br />SW
<br />SWITCH
<br />LIGHTING
<br />SWBR
<br />SWITCHBOARD
<br />MINIMUM CIRCUIT AMPS
<br />SWGR
<br />SWITCHGEAR
<br />MAIN CIRCUIT BREAKER
<br />TBB
<br />TELECOM BACKBOARD
<br />MOTOR CONTROL CENTER
<br />TELE
<br />TELEPHONE
<br />MOLDED CASE CIRCUIT BREAKER
<br />TYP
<br />TYPICAL
<br />MOTOR CIRCUIT PROTECTOR
<br />UG
<br />UNDERGROUND
<br />MAIN DISTRIBUTION PANEL
<br />LINO
<br />UNLESS NOTED OTHERWISE
<br />MAXIMUM FUSE SIZE
<br />UPS
<br />UNINTERRUPTIBLE
<br />MAIN LUG ONLY
<br />POWER SUPPLY
<br />MAXIMUM OVERCURRENT PROTECTION
<br />V
<br />VOLT
<br />MOUNTED
<br />VIF
<br />VERIFY IN FIELD
<br />MANUAL TRANSFER SWITCH
<br />W/
<br />WITH
<br />NORMALLY CLOSED
<br />W
<br />WIRE
<br />NORMALLY OPEN
<br />WP
<br />WEATHER PROOF
<br />NOT TO SCALE
<br />XFMR
<br />TRANSFORMER
<br />OVERCURRENT PROTECTION DEVICE
<br />OVERHEAD
<br />Bank of America
<br />ADA- ZEPHYRHILLS
<br />5632 GALL BOULEVARD
<br />ZEPHYRHILLS, FL 33542
<br />SERIAL NUM./MANH. ID: FL2-019
<br />ON
<br />Nelco Architecture, Inc.
<br />a licensed affiliate
<br />Florida Certificate of Authorization Number: AA26000525
<br />Architect: Client Representative:
<br />Firm Name: NELSON Firm Name: ILL
<br />Attn: Mark Schroeder Attn: David Berrios
<br />T: 404.881.1811 Tel.: 813.245.0909
<br />e-mail: mschroeder@nelsononline.com e-mail: David.Berrios@am.jll.com
<br />Engineer:
<br />Firm Name: Infinity Engineering Group, LLC.
<br />Attn: Brett Nevaril
<br />1208 E Kennedy Blvd, STE 230
<br />Tampa, FL 33602
<br />T: 813.434-4770
<br />e-mail: brett@iegroup.net
<br />Certification of Authorization #27889
<br />General Contractor:
<br />Firm Name: Spartan Contracting Corporation
<br />Attn: Scott Kramer
<br />T: 813.481.5778
<br />e-mail: skramer@spartancc.com
<br />IIssue Date & Issue Description By Check
<br />1 04/23/18 Issue For Review KL CV
<br />2 04/27/18 Issue For Permit KL CV
<br />Seal/Signature
<br />NISIT SAPPARKHAO, P.E.
<br />FL' REG. NO. 64085
<br />w.
<br />• No 6 085
<br />cc
<br />r
<br />:� STA E OF
<br />o Q •• Al
<br />40
<br />QI
<br />DATE
<br />Proiect Name
<br />Bank of America
<br />Zephyrhills
<br />AWA upgraae
<br />INELSON Project Number
<br />18.00358.00110-65.439
<br />Description
<br />ELECTRICAL GENERAL NOTES AND LEGEND
<br />Scale & Sheet Number
<br />AS INDICATED
<br />E00m01
<br />
|