My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5632 Gall Blvd (6)
Zephyrhills
>
Building Department
>
Building Plans
>
5632 Gall Blvd (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:47:56 PM
Creation date
1/21/2025 3:37:26 PM
Metadata
Fields
Template:
Building Plans
Street #
5632
Location
Gall Blvd
Contractor
Spartan Contracting
Building Plans - Permit #
19779
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I 1 I I I I — I __ I I I I <br />BREAK <br />LOBBY <br />RESTROOM <br />JANITOR <br />RESTROOM <br />ROOM <br />100 <br />r- <br />101 <br />r—i <br />104 <br />r---�— <br />102 <br />103 <br />PLUMBING DEMOLITION PLAN KEYED NOTES: <br />n REMOVE WATER CLOSET AND PIPING AT MAIN: REMOVE EXISTING WATER CLOSET. CUT AND CAP <br />�1 EXISTING WATER SUPPLY, WASTE, AND VENT PIPING AT MAIN. <br />REMOVE LAVATORY AND PIPING AT MAIN: REMOVE EXISTING LAVATORY. CUT AND CAP EXISTING <br />(J WATER SUPPLY, WASTE, AND VENT PIPING AT MAIN. <br />0 EXISTING FIXTURES: ALL EXISTING PLUMBING FIXTURES IN THIS AREA ARE TO REMAIN. <br />BREAK <br />LOBBY RESTROOM JANITOR RESTROOM ROOM <br />PLUMBING PROPOSED PLAN KEYED NOTES - <br />NEW NEW WATER CLOSET CONNECTING TO MAIN: INSTALL NEW WATER CLOSET, CONNECT 1/2" DOMESTIC <br />(J COLD WATER, 4" SANITARY, AND 2" VENT LINES TO EXISTING MAIN. SEE PLUMBING FIXTURE SCHEDULE <br />WC FOR MORE INFORMATION. <br />`/ NEW LAVATORY CONNECTING TO MAIN: INSTALL NEW LAVATORY, CONNECT 1/2" DOMESTIC COLD AND <br />( <br />��/ HOT WATER, 2" SANITARY, AND 1-1/2" VENT LINES TO EXISTING MAIN. PROVIDE ASSE 1070 <br />THERMOSTATIC MIXING VALVE, SET OUTLET TEMPERATURE TO 100°F. SEE PLUMBING FIXTURE <br />SCHEDULE LAV FOR MORE INFORMATION. <br />0VADJUST FLOOR DRAIN: ADJUST EXISTING FLOOR DRAIN HEIGHT AND LOCATION AS NEEDED PER NEW <br />FINISHES TO PROVIDE PROPER SLOPE AND MAKE FLUSH WITH FLOOR. <br />0 RECONFIGURE PLUMBING: RECONFIGURE EXISTING SANITARY STACKS AND WATER LINES AS NEEDED <br />TO CORRESPOND WITH NEW FIXTURE LOCATIONS. REFER TO PLUMBING RISER DIAGRAM FOR <br />ADDITIONAL INFORMATION. <br />0 HOT WATER: PLUMBING CONTRACTOR TO ENSURE THAT EXISTING ELECTRIC TANK WATER HEATER IS <br />IN GOOD WORKING CONDITION AND THAT HOT WATER IS PROVIDED TO FIXTURES, <br />GENERAL PLUMBING NOTES: <br />A. <br />PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM <br />RUNS (100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR <br />ALL LABOR REQUIRED TO INSTALL COMPLETE AND <br />ALTERATION AND REPAIRS. <br />OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE <br />DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. <br />O. <br />ALL VALVES SHALL BE ADJUSTED FOR SMOOTH AND EASY <br />OPERATION. <br />B. <br />RUN ALL SOIL WASTE AND VENT PIPING WITH 2% MINIMUM <br />GRADE UNLESS OTHERWISE NOTED. HORIZONTAL VENT <br />P. <br />ALL VALVES (EXCEPT CONTROL VALVES) AND STRAINERS <br />PIPING SHALL BE GRADED TO DRIP BACK TO THE SOIL OR <br />SHALL BE FULL SIZE OF PIPE BEFORE REDUCING SIZE TO <br />WASTE PIPE BY GRAVITY. <br />MAKE CONNECTIONS TO EQUIPMENT AND CONTROLS, <br />C. <br />ELEVATIONS AS SHOWN ON THE DRAWINGS ARE TO THE <br />Q. <br />PROVIDE CHAINWHEEL OPERATORS FOR ALL VALVES IN <br />CENTERLINE OF ALL PRESSURE PIPING AND TO THE <br />EQUIPMENT ROOMS MOUNTED GREATER THAN T-0" <br />INVERT OF ALL GRAVITY PIPING. <br />ABOVE FLOOR LEVEL; CHAIN SHALL EXTEND TO T-0" <br />ABOVE FLOOR LEVEL. <br />D. <br />ADJUST SEWER INVERTS TO KEEP TOPS OF PIPE IN LINE <br />WHERE PIPE SIZE CHANGES. <br />R. <br />PROVIDE ALL PLUMBING FIXTURES AND EQUIPMENT WITH <br />ACCESSIBLE STOPS. <br />E. <br />MAINTAIN A MINIMUM OF 3'6" OF GROUND COVER OVER <br />ALL UNDERGROUND WATER MAINS AND A MINIMUM OF 3'0" <br />S. <br />UNLESS OTHERWISE NOTED, DRAINS SHALL BE INSTALLED <br />OF GROUND COVER OVER ALL UNDERGROUND SEWERS <br />AT THE LOW POINT OF ROOFS, AREAWAYS, FLOORS, ETC. <br />AND DRAINS. <br />T. <br />PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE <br />F. <br />PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER <br />SYSTEMS AT ENDS OF RUNS, AT CHANGES IN DIRECTION, <br />PIPING SYSTEM BRANCHES IN WHICH BRANCH PIPING <br />NEAR THE BASE OF STACKS, EVERY 50 FEET IN <br />SERVES TWO OR MORE FIXTURES- <br />HORIZONTAL RUNS AND ELSEWHERE AS INDICATED (EDIT <br />HORIZONTAL CLEANOUT SPACING TO SUIT CODE AND <br />G. <br />UNLESS OTHERWISE NOTED, ALL DOMESTIC COLD AND <br />PROJECT REQUIREMENTS). <br />HOT WATER PIPING SHALL BE 12 INCH SIZE. <br />U. <br />ALL CLEANOUTS SHALL BE FULL SIZE OF PIPE FOR PIPE <br />H. <br />UNLESS OTHERWISE NOTED, ALL PIPING IS OVERHEAD, <br />SIZES 6 INCHES AND SMALLER AND SHALL BE 6 INCHES <br />TIGHT TO UNDERSIDE OF SLAB, WITH SPACE FOR <br />FOR PIPE SIZES LARGER THAN 6 INCHES. <br />INSULATION IF REQUIRED- <br />V. <br />ALL BALANCING VALVES AND BUTTERFLY VALVES SHALL <br />I. <br />INSTALL PIPING SO THAT ALL VALVES, STRAINERS, <br />BE PROVIDED WITH POSITION INDICATORS AND MAXIMUM <br />UNIONS, TRAPS, FLANGES, AND OTHER APPURTENANCES <br />ADJUSTABLE STOPS (MEMORY STOPS). <br />REQUIRING ACCESS ARE ACCESSIBLE. <br />W. <br />ALL VALVES SHALL BE INSTALLED SO THAT VALVE <br />J. <br />WHERE DOMESTIC COLD AND HOT WATER PIPING DROPS <br />REMAINS IN SERVICE WHEN EQUIPMENT OR PIPING ON <br />INTO A PIPE CHASE, THE SIZE SHOWN FOR THE PIPE <br />EQUIPMENT SIDE OF VALVE IS REMOVED. <br />DROPS SHALL BE USED TO THE LAST FIXTURE. <br />X. <br />ALL PIPING WORK SHALL BE COORDINATED WITH ALL <br />K. <br />INSTALL ALL PIPING WITHOUT FORCING OR SPRINGING. <br />TRADES INVOLVED. OFFSETS IN PIPING AROUND <br />OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL <br />L. <br />ALL PIPING SHALL CLEAR DOORS AND WINDOWS. <br />COST TO THE OWNER. <br />M. <br />ALL PIPING SHALL GRADE TO LOW POINTS. PROVIDE HOSE <br />Y. <br />PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING SYSTEMS <br />END DRAIN VALVES AT THE BOTTOM OF ALL RISERS AND <br />CONNECTED TO PUMPS AND OTHER EQUIPMENT WHICH <br />LOW POINTS. <br />REQUIRE VIBRATION ISOLATION. FLEXIBLE CONNECTIONS <br />SHALL BE PROVIDED AS CLOSE TO THE EQUIPMENT AS <br />N. <br />UNIONS AND/OR FLANGES SHALL BE INSTALLED AT EACH <br />POSSIBLE OR AS INDICATED ON THE DRAWINGS. <br />PIECE OF EQUIPMENT, IN BYPASSES, AND IN LONG PIPING <br />MECHANICAL SCOPE OF WORK: <br />THE SCOPE OF WORK FOR THIS PROJECT DOES NOT <br />INCLUDE ANY MECHANICAL MODIFICATION TO THE <br />EXISTING SYSTEMS ALREADY IN PLACE. GENERAL <br />CONTRACTOR SHALL FIELD VERIFY IF ANY ALTERATIONS <br />TO THE EXISTING SYSTEMS ARE REQUIRED AND CONTACT <br />THE ARCHITECT OF RECORD PRIOR TO START OF WORK. <br />KEY PLAN: <br />AREA OF WORK <br />LINE AND HATCH LEGEND: <br />NOTE: <br />REFER TO DEMOLITION PLANS FOR NOTES AND REQUIREMENTS. <br />DASHED LINES INDICATE EXISTING TO BE REMOVED. <br />_.._... ...._.. _...... LIGHT DASHED LINES INDICATE EXISTING TO BE <br />REMOVED BUT ARE NOT PART OF DISCIPLINE. <br />LIGHT LINES INDICATE EXISTING TO REMAIN. <br />DARK LINES INDICATE NEW/RELOCATED OR <br />EXISTING TO BE RELOCATED. <br />AREA NOT IN SCOPE OF <br />WORK FOR THIS DISCIPLINE <br />wlmmllHiq r 9^rep 77 <br />�i I I�� <br />I�..I <br />P <br />� wI <br />I <br />_ �I gull llluluulpluil�uuuuluiuuuullluu _.. <br />. +4� �9111111 a iwi Illlltl� i�. <br />yl <br />q � 1 <br />IIII pp .,. IIIII <br />Illlillll <br />ti. <br />� ,,,,. <br />_ p _ <br />J <br />�V!IIIIIIIWII V�VQIaa � 'tlP' MITI-011I L. <br />fi <br />Bank of America W <br />ADA- ZEPHYRHILL S <br />5632 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />SERIAL NUM./MANH. ID: FL2-019 <br />-611 :11 4 1; 1*] 1 — <br />Nelco Architecture, Inc. <br />a licensed affiliate <br />Florida Certificate of Authorization Number: AA26000525 <br />Architect: <br />Client Representative: <br />Firm Name: NELSON <br />Firm Name: JLL <br />Attn: Mark Schroeder <br />Attn: David Berrios <br />T: 404.881.1811 <br />Tel.: 813.245.0909 <br />e-mail: mschroeder@nelsononline.com <br />e-mail: David.Berrios@am.jll.com <br />Engineer: <br />Firm Name: Infinity Engineering Group, LLC, <br />Attn: Brett Nevaril <br />1208 E Kennedy Blvd, STE 230 <br />Tampa, FL 33602 <br />T:813.434-4770 <br />e-mail: brett@iegroup.net <br />Certification of Authorization #27889 <br />General Contractor: <br />Firm Name: Spartan Contracting Corporation <br />Attn: Scott Kramer <br />T:813.481.5778 <br />e-mail: skramer@spartancc.com <br />IIssue Date & Issue Description By Check <br />1 04/23/18 Issue For Review JP VO <br />2 04/27/18 Issue For Permit JP VO <br />ISeal/Signature <br />NISIT SAPPARKHAO, P.E. <br />FL REG. <br />NO. 64085 <br />12)y <br />•�. <br />0 <br />•• No <br />B <br />85 <br />� ' <br />a w <br />STA <br />OF ' �U <br />y <br />Project Name <br />Bank of America <br />Zephyrhills <br />lProject Type <br />ADA Upgrade <br />INELSON Project Number <br />18.00358.00 / 10-65.439 <br />Description <br />PLUMBING DEMOLITION AND PROPOSED PLAN <br />IScale & Sheet Number <br />AS INDICATED <br />P02mOl <br />
The URL can be used to link to this page
Your browser does not support the video tag.