My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5632 Gall Blvd (6)
Zephyrhills
>
Building Department
>
Building Plans
>
5632 Gall Blvd (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:47:56 PM
Creation date
1/21/2025 3:37:26 PM
Metadata
Fields
Template:
Building Plans
Street #
5632
Location
Gall Blvd
Contractor
Spartan Contracting
Building Plans - Permit #
19779
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FINISH SCHEDULE <br />ACCESSIBLE <br />OPEN OPEN ATM UNISEX UNISEX BREAK <br />OFFICE OFFICE OFFICE ROOM LOBBY RESTROOM JANITOR RESTROOM ROOM <br />MARK <br />DISCRIPTION <br />LAMINATE <br />DESCRIPTION: HIGH WEAR LAMINATE <br />MANUFACTURER: WILSONART <br />COLOR NAME: WALLABY HW <br />COLOR NUMBER: #D439-60HW <br />FINISH: #60 MATTE <br />WALK -OFF MAT <br />VVM-m1 <br />DESCRIPTION: RECESSED FLOOR MAT <br />MANUFACTURER: REESE ENTERPRISES, INC <br />STYLE: PERFEC MAT <br />SIZE: DOUBLE DOOR- 68-1/4" V.T.F. x 6' 4" V.T.F. <br />COLOR: POLYPROPYLENE BRUSH: GRAY TREAD <br />FLAILS: ANODIZED ALUMINUM- CLEAR <br />INSERT: 2" SQ. VINYL EDGE- BLACK <br />GC NOTE: VERIFY TILE THICKNESS UPON DEMO. <br />IF OVERALL THICKNESS IS LESS THAN <br />3/8" NOTIFY ARCHITECT <br />PAINT <br />( P-4 ) <br />DESCRIPTION: INTERIOR PAINT <br />MANUFACTURER: BENJAMIN MOORE <br />STYLE: OC-15 <br />COLOR: BABY FAWN <br />FINISH: EGGSHELL, SATIN IN RESTROOMS <br />---. P-4A <br />DESCRIPTION: INTERIOR EPDXY WALL <br />- <br />COATING <br />MANUFACTURER: DUR-A-FLEX <br />PRODUCT NAME: DUR-A-WALL <br />COLOR: COLOR MATCH TO BENJAMIN <br />MOORE BABY FAWN <br />*TO BE USED ON ALL WALLS IN RESTROOMS <br />BASE <br />(" B-2 <br />DESCRIPTION: RUBBER WALL BASE <br />MANUFACTURER: JOHNSONITE <br />STYLE: 1/8" THICK, 4" HIGH <br />COLOR NAME: GROUNDED <br />COLOR NUMBER: 264 <br />INSTALLATION: USE COVE BASE WITH <br />RESILIENT FLOORING <br />TRANSITION STRIP <br />T_S-1 <br />DESCRIPTION: CARPET/CERAMIC TILE TRANSITION <br />_) <br />MANUFACTURER: GENOTEK <br />MODEL NO.: 233 <br />63 SATIN SILVER <br />PRODUCT NAME: FLEX <br />VINYL COMPOSITE TILE <br />DESCRIPTION: RESILIENT FLOOR TILE <br />MANUFACTURER: ARMSTRONG <br />SIZE: 12" X 12" <br />COLOR NAME: TANNIN <br />COLOR NUMBER: 59243 <br />KEY NOTES GRAPHIC SYMBOLS SHEET NOTES <br />FURNISH AND INSTALL NEW BANK STANDARD THRESHOLD, SEE 05/AO0.40 TO <br />MEET THE FAC STANDARD. <br />FURNISH AND INSTALL NEW BANK STANDARD VERTICAL TACTILE EXIT SIGN, <br />SEE DETAIL 03/A00.41 FOR MOUNTING HEIGHTS AND SPECIFICATION. <br />1D FURNISH AND INSTALL NEW BANK STANDARD RECESSED WALK OFF MAT (WM-1) <br />WITH TS-1 EDGE METAL TO DEFINE THE INSERT. SEE FINISH SCHEDULE. PATCH <br />AND REPAIR SURROUNDING SURFACES DAMAGED OR EXPOSED DURING <br />CONSTRUCTION. <br />0 FURNISH AND INSTALL NEW OCCUPANCY SENSOR SWITCH, SEE MEP DRAWINGS <br />FOR SPECIFICATIONS. <br />l�5 FURNISH AND INSTALL NEW DUPLEX RECEPTACLE, 9" ABOVE COUNTER. SEE MEP <br />DRAWINGS FOR SPECIFICATIONS. <br />(D FURNISH AND INSTALL NEW ACCESSIBLE BANK STANDARD LEVER HARDWARE. <br />ALL OTHER HARDWARE COMPONENTS TO REMAIN. <br />1 PRIVACY SET: MANUFACTURER: SCHLAGE ND40S SPA: FINISH 626 <br />FURNISH AND INSTALL ACCESSIBLE SIGNAGE WITH RAISED CHARACTERS AND <br />BRAILLE INDICATING ROOM AS ACCESSIBLE, SEE 02/AOO.41. <br />GINSTALL NEW BANK STANDARD QUEUE LINE SYSTEM. PROJECT MANAGER TO <br />COORDINATE WITH FINANCIAL MERCHANDISING TEAM. <br />PROVIDE NEW CH-27B BERNHARDT HELIUM CHAIR FOR CUSTOMER FACING ADA <br />TELLER STATION. <br />G <br />PROVIDE NEW CH-513 STEELCASE TURNSTONE A LA CARTE CHAIR FOR BACK OF <br />HOUSE FACING ADA TELLER STATION. <br />11 ADJUST THE DOOR CLOSER AT A MAXIMUM OPENING FORCE OF 5 LB TO MEET <br />THE FAC STANDARD. <br />ALTERNATE: REPLACE THE DOOR CLOSER WITH A UNIT THAT WILL NOT <br />REQUIRE MORE THAN 5 LB TO OPERATE TO MEET FAC STANDARD. <br />G <br />PATCH AND REPAIR ADJACENT SURFACES DAMAGED OR EXPOSED DURING <br />DEMOLITION. <br />G <br />RELOCATE SALVAGED FURNITURE, AS NECESSARY, TO ACCOMMODATE <br />REQUIRED DOOR CLEARANCE. <br />NNOMMEMM EXISTING PARTITION TO REMAIN <br />NEW PARTITION <br />A PARTITION TYPE, SEE AOO.30 <br />EXISTING DOOR TO REMAIN <br />NEW DOOR <br />XX KEYNOTE <br />FIRE EXTINGUISHER CANISTER <br />F_EEC FIRE EXTINGUISHER CABINET <br />ROOM ROOM NAME <br />101 ROOM NUMBER <br />XXX DOOR TAG, SEE AOO.30 <br />5' ADA TURN AROUND SPACE <br />SHADED LOCATIONS DEFINE AREA NOT IN <br />CONTRACT <br />ALIGN ALIGN WITH ESTABLISHED SURFACES A. <br />�4 B. <br />EXTERIOR ELEVATION INDICATION C. <br />D. <br />ON ELEVATION SHEET WHERE SHOWN E. <br />DIRECTION OF ELEVATION <br />4k�� SHEET WHERE SHOWN <br />F. <br />INTERIOR ELEVATION INDICATION <br />G. <br />A..---- -- -- LOCATION ON ROW WHERE SHOWN <br />-- DIRECTION OF ELEVATION <br />ON ELEVATION SHEET WHERE SHOWN <br />SHEET WHERE SHOWN H. <br />I. <br />DETAIL NUMBER <br />DESCRIPTION OF SIMILAR OR TYP. J. <br />AREA TO BE DETAILED K. <br />DIRECTION OF ELEVATION <br />XX ON ELEVATION SHEET WHERE SHOWN L <br />SHEET WHERE SHOWN M. <br />0 REVISION REFERENCE <br />REVIEW GENERAL NOTES BEFORE COMMENCING WORK. <br />IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CERAMIC TILE, <br />CARPETING TACKLES, PARTITIONS, ETC.) CAUSES UNEVENNESS OF SLAB, THE <br />FLOORING VENDOR SHALL PATCH TO LEVEL THE SLAB TO RECEIVE NEW <br />FINISHED FLOORING. <br />PATCH AND REPAIR FIREPROOFING MATERIAL WHERE NECESSARY TO MAINTAIN <br />REQUIRED FIRE RATING. <br />ALL DIMENSIONS ARE TO FINISH FACE OF WALL U.N.O. <br />DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CONTRACTOR IN <br />THE FIELD. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCY IN <br />DIMENSIONS PRIOR TO PROCEEDING WITH THE WORK IN THAT AREA. <br />NEW GYPSUM BOARD CONSTRUCTION ADJOINING EXISTING CONSTRUCTION IN <br />THE SAME PLANE SHALLBE FLUSH WITH NO VISIBLE JOINTS, UNLESS <br />OTHERWISE NOTED. <br />DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS <br />AND SPECIFICATIONS, EXCEPTION: COMPLY WITH MORE STRINGENT <br />REQUIREMENTS OF GYPSUM ASSOCIA11ON GA-216 RECOMMENDED <br />SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD. <br />CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING FOR MILLWORK, <br />LIGHTS, WHITE BOARDS, ETC. PRIOR TO CLOSING WALLS. <br />PENETRATIONS IN GYPSUM BOARD CONSTRUC11ON ABOVE FINISHED CEILING <br />SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AT ACOUSTICAL <br />PARTITIONS AND AT DEMISING PARTITIONS, UNLESS OTHERWISE NOTED. <br />CONTRACTOR SHALL COORDINATE STUD LOCATIONS W/OUTLET DIMENSIONS <br />PRIOR TO CLOSING WALLS W/ G.W.B. <br />WHERE A CHANGE OF PLANE OF 1/4—INCH OR MORE OCCURS, SUBMIT <br />N011FICATION OF THE INSTANCE AND RECOMMENDA11ON FOR PROVIDING A <br />CORREC11ON AND SMOOTH TRANSITION, TO THE A/E FOR REVIEW. <br />SEAL FLOOR PENETRATIONS TO LIKE NEW SLAB CONDITION TO MATCH <br />EXISTING CONSTRUCTION. <br />PATCH AND REPAIR: EXISTING CONSTRUCTION WHERE AFFECTED BY <br />DEMOLITION WORK SHALL BE PROPERLY RESTORED, ALIGNED AND REPAIRED <br />SO AS TO LEAVE NO EVIDENCE OF DEMOLITION OR REMODELING WORK. AREAS <br />OUTSIDE OF THE CONTRACT LIMITS AFFECTED BY DEMOLITION AND NEW <br />CONSTRUCTION TO BE REPAIRED SO AS TO LEAVE NO EVIDENCE OF THE <br />WORK. REFINISH TO MATCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. <br />Bank of America <br />ADA- ZEPHYRHILLS <br />5632 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />SERIAL NUM./MANH. ID: FL2-019 <br />Nelco Architecture, Inc. <br />a licensed affiliate <br />Florida Certificate of Authorization Number: AA26000525 <br />Architect: Client Representative, <br />Firm Name: NELSON Firm Name: ILL <br />Attn: Mark Schroeder Attn: Lisa Drees <br />T: 404.881.1811 T: 813.624.4512 <br />e-mail: mschroeder@nelsononline.com e-mail: lisa.drees@am.jll.com <br />Engineering: <br />Infinity Engineering Group, LLC <br />Attn: Nisit Sapparkhao <br />T: 813.830.2330 <br />e-mail: nisit@iegroup.net <br />General Contractor: <br />Firm Name: Spartan Contracting Corporation <br />Attn: Scott Kramer <br />T' 813.481.5778` <br />e-mail: skramer@spartancc.com <br />�U Issue <br />Date & Issue Description <br />By <br />Check <br />1.■III Ills 1II 1111■11 lwllllllllwrllrl■I■Illw,ll <br />1 <br />I�Iw.0 II■III■Irwwrw�w��lww <br />03/23/18 Issue For Review <br />AJB <br />AFO <br />2 <br />04/23/18 Issue For CD Review <br />KS <br />AFO/MS <br />3 <br />04/27/18 Issue For Permit <br />KS <br />MS <br />ISeal/Slgnnature <br />�� wrllllrin■moll Ilwrnrwnul <br />Architect of Record, Mark Schroeder <br />Lic. # : AR0016438 <br />J <br />3c) 1k E <br />IProject Name <br />il�l�l�l I■If IIIIIIIwIL011lll■■rw <br />Bank of America <br />Zephyrhills <br />Project Type <br />� I■LIII.■IIwIA•wwwllr■I■Illlwllr�lllwl <br />ADA Upgrade <br />NELSON Project Number <br />�I�I I I I l.rl �.■.� Ill�wrl <br />18.00358.00 <br />Description <br />CONSTRUCTION PLAN <br />' Scale & Sheet Number <br />��■w Ilwlllllllr llllw�l*Illrwl.rlwllllw <br />0 4' 8' 16' <br />SCALE: 3/16" = 1'-0„ N <br />A02m01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.