My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5915 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5915 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:58:39 PM
Creation date
1/21/2025 3:38:22 PM
Metadata
Fields
Template:
Building Plans
Street #
5915
Location
Gall Blvd
Contractor
Osage Contractors LLC
Building Plans - Permit #
20581
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lz <br />PROJECT GENERAL NOTES SYMBOLS SHEET INDEX <br />1. FIELD VERIFY ALL DIMENSIONS. ROOM NAME O DOOR NUMBER L LEGAL JURISDICTION: ZEPHYRHILLS, FLORIDA TITLE <br />2. NOT USED. APPLICABLE CODES: T1 TITLE SHEET <br />3. REPLACE OR REPAIR DAMAGED, DETERIORATED OR UNSUITABLE SUBSTRATES AS REQUIRED TO 1 0 WINDOW NUMBER <br />RECEIVE NEW WALL FINISHES AS SCHEDULED. <br />4. NOT USED. ROOM NUMBER BUILDING CODE: 2017 FLORIDA BUILDING CODE <br />4 22ELEV. N0. EXTERNAL WALL FINISH NUMBER <br />5. NOT USED. PLUMBING CODE: 2017 FLORIDA BUILDING CODE PLUMBING ARCHITECTURAL <br />6. CUT, REMOVE AND REPLACE EXISTING CONCRETE SLAB AS REQUIRED FOR INSTALLATION OF NEW 3 INT. ELEV. SHEET ID <br />UNDERFLOOR PIPING AND CONDUIT. SHEAR WALL TYPE MECHANICAL CODE: 2017 FLORIDA BUILDING CODE MECHANICAL <br />7. ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL DIRECTION OF DETAIL ELECTRICAL CODE: 2014 NATIONAL ELECTRIC CODE <br />BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. ELEV. LETTER ❑ FRAMING HEADER NUMBER Al ARCHITECTURAL FLOOR PLAN <br />— <br />8. ALL REMODELED BUILDING ELEMENTS INCLUDED AS PART OF THIS PROJECT SHALL COMPLY ELEV. SHEET ENERGY CODE: 2017 FLORIDA BUILDING CODE ENERGY CONSERVATION A2 EQUIPMENT PLAN <br />WITH THE MOST CURRENT EDITION OF BUILDING CODE, AND LOCAL CODE. KEYNOTE A2.1 EQUIPMENT SCHEDULE <br />9. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, CONTRACTOR SHALL VERIFY EXISTENCE ACCESSIBILITY CODE: 2017 FLORIDA ACCESSIBILITY CODE <br />AND LOCATION OF ALL EXISTING ABOVE AND BELOW GRADE UTILITIES, INCLUDING SANITARY DIRECTION OF DETAIL A3 FINISH SCHEDULE <br />SEWER, STORM SEWER, WATER, GAS, ELECTRICAL, TELEPHONE, ETC. ANY DISCREPANCIES IN LOCATION OF SECTION O EQUIPMENT ROUGH -IN CONNECTION, NUMBER A4 CUSTOMER CARRY -OUT SERVICE COUNTER <br />UTILITY LOCATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER'S DETAIL SHEET AND RESTROOM ELEVATIONS AND DETAILS <br />REPRESENTATIVE. DETAIL NUMBER <br />10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE BUILDING'S STRUCTURAL® BLDG. HEIGHT A5 INTERIOR WALL FINISH PLAN <br />SYSTEM. STRUCTURAL MEMBERS, INCLUDING BEARING AND SHEAR WALLS, SHALL NOT BE REVISION NUMBER REFERENCE POINT A7 REFLECTED CEILING PLAN <br />REMOVED, CUT OR OTHERWISE MODIFIED WITHOUT WRITTEN AUTHORIZATION FROM THE <br />OWNER'S REPRESENTATIVE. <br />A8 MISC. DETAILS <br />11. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL BUILDING ABBREVIATIONS A9 ROOF PLAN AND RELATED DETAILS <br />DIMENSIONS AND SHALL IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE OF ANY VARIANCE <br />OR DISCREPANCY AFFECTING NEW CONSTRUCTION. <br />12. GENERAL CONTRACTOR SHALL COORDINATE EXISTING STRUCTURE WITH NEW CONSTRUCTION A.B. ANCHOR BOLT F.P. FIRE PROOF REINF. REINFORCING <br />INCLUDING MECHANICAL, FIRE PROTECTION AND ELECTRICAL WORK. A.T. ACOUSTICAL TILE FLASH FLASHING REQ'D. REQUIRED MECHANICAL <br />13. CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING IN WALLS FOR SUPPORT OF FLR. FLOOR RET. RETURN <br />ALL EQUIPMENT, SHELVING, ACCESSORIES AND OTHER DEVICES REQUIRED. ADJ. ADJUSTIBLE R.A. RETURN AIR F.D. FLOOR DRAIN GROSS LEASE AREA: 1,892 SQ. FT. <br />. <br />14. ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. A.F.F. ABOVE FINISH FLOOR SEATING: NONE M1 H.V.A.C. FLOOR PLAN <br />F.S. FLOOR SINK REV. REVERSE M2 H.V.A.C. SCHEDULES <br />15. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE A.C. AIR CONDITIONING FT. FOOT RCP REFLECTED CEILING OCCUPANCY GROUP: B <br />ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK. ANOD. ANODIZED FTG. FOOTING PLAN M3 H.V.A.C. DETAILS <br />16. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF ALUM AL ALUMINUM R.D. ROOF DRAIN OCCUPANCY LOAD: GROSS SQ. FT. WHOLE SPACE = 1,892 SQ. FT. <br />FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. / FDN. FOUNDATION M4 H.V.A.C. DETAILS <br />17. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNING EXISTING APPROX. APPROXIMATE GA. GAUGE ROOF'G. ROOFING "BUSINESS AREAS" = 413 SF/100 SF (GROSS) = 5 OCCUPANTS M5 H.V.A.C. GENERAL NOTES <br />PARTITIONS, ETC., VERIFICATION MUST BE DONE IN THE FIELD. BD. BOARD RM. ROOM (INCLUDING RESTROOM) <br />G.C. GENERAL CONTRACTOR M6 HOOD DRAWINGS <br />18. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL BM. BEAM GEN. GENERAL R.O. ROUGH OPENING "KITCHEN AREAS" = 1,479 SF/200 SF (GROSS) = 8 OCCUPANTS <br />JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND BLK. BLOCK M7 ANSUL DRAWINGS <br />CERTIFICATES OF OCCUPANCY. G.I. GALVANIZED IRON S.E. SATIN ENAMEL <br />BLK'G. BLOCKING TOTAL OCCUPANT LOAD = 13 M8 HOOD FAN DRAWINGS <br />19. THESE CONSTRUCTION NOTES AND DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN GL. GLASS; GLAZING; GLAZED SCHED. SCHEDULE <br />AND GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE BOT. BOTTOM GR. GRADE FINEST QUALITY OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT. BLDG BUILDING GYP. GYPSUM SECT. SECTION EXITS REQUIRED _EXITS PROVIDED = 3 ELECTRICAL <br />20. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND B.N. BOUNDARY NAIL HDWD HARDWOOD S.G.E. SEMI -GLOSS ENAMEL <br />ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND <br />COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. CAB. CABINET HDWE HARDWARE SHT'G. SHEATHING E1 ELECTRICAL RISER DIAGRAMS <br />21. GENERAL CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS FOR DETAILS 2, 5, 9, 10, AND CLG. CEILING H.D. HUB DRAIN SHT. SHEET E2 ELECTRICAL POWER/ROOF PLAN <br />15/AB TO DETERMINE FOR CONNECTING TO STRUCTURE ABOVE. CEM. CEMENT HT. HEIGHT S.C.R. SILICONE CONTROL <br />22. ALL CHANGE ORDER REQUESTS SHALL BE SUBMITTED IN WRITING TO NPC PROJECT MANAGER H.M. HOLLOW METAL RECTIFIER E3 ELECTRICAL LIGHTING PLAN <br />FOR APPROVAL PRIOR TO MAKING ANY CHANGES. CL C.F. CURB FACE CENTERLINE HORIZ. HORIZONTAL SIM. SIMILAR PROJECT DIRECTORY E4 HOOD CONTROL DRAWINGS <br />23. G.C./SUBCONTRACTORS ARE RESPONSIBLE FOR MECHANICAL, ELECTRICAL AND PLUMBING I/F INTERFACE SK. SINK <br />PERMITS. C.T. CERAMIC TILE INS. INSULATE; INSULATION S.D. SOAP DISPENSER <br />NOTE: <br />CLR. CLEAR INT. INTERIOR S.O.H. SAME OPPOSITE HAND CONTACT BORIS SANCHEZ (INFORMATION BELOW) FOR ALL BID INQUIRIES PLUMBING <br />COL. COLUMN JNT. JOINT SOL. SOLID ON THIS PROJECT. <br />CONC. CONCRETE JST. JOIST SPECS. SPECIFICATIONS <br />P1 PLUMBING SCHEDULES <br />C.B. CONCRETE BLOCK LAM. LAMINATE; LAMINATED SQ. SQUARE OWNER ARCHITECT <br />LTGLIGHTING S.S. S/S STAINLESS STEEL P2 WASTE AND VENT PLAN <br />. <br />CONST. CONSTRUCTION S.S.D. SEE STRUCTURAL DWGS NPC INTERNATIONAL LICKEL ARCHITECTURE P3 GAS AND WATER SERVICE PLAN <br />MFR. MANUFACTURER 7300 W. 129TH. ST. 14 WEST 3RD STREET <br />CONT. CONTINUOUS MAT'L. MATERIAL STD. STANDARD OVERLAND PARK, KANSAS 66213 KANSAS CITY, MISSOURI 64105 P4 PLUMBING DETAILS <br />C.J. CONTRACTION OR STL. STEEL PHONE: (913) 327-5555 PHONE: (816) 421-0707 <br />CONTROL JOINT MAX. MAXIMUM FAX: (913) 327-5850 FAX: (816) 421-2191 <br />CONTR. CONTRACTOR MECH. MECHANICAL STOR. STORAGE CONTACT: DAN LICKEL SPECIFICATIONS <br />CORR. CORRIDOR MEMB. MEMBRANE ST. STREET; STRAIN <br />NPC PROJECT MANAGER MECHANICAL/ELECTRICAL ENGINEER <br />CTRD. CENTERED MET/MTL METAL STRUCT. STRUCTURAL SPECIFICATIONS PROVIDED ON A CD IN BOOK FORMAT. <br />DP. DEEP M.L. METAL LATH SUSP. SUSPEND; SUSPENDED BORIS SANCHEZ BRIAN TIMMONS <br />DET. DETAIL MIN. MINIMUM SW. SWITCH 25400 US 19S 14817 WEST 95TH. ST. <br />CLEARWATER, FL 33763 LENEXA, KANSAS 66215 <br />MISC. MISCELLANEOUS SYS. SYSTEM <br />DIAL. DIAGONAL PHONE: (786) 457-1131 PHONE: (913) 322-5150 <br />DIA. DIAMETER MLDG. MOULDING TEL. TELEPHONE <br />DIM. DIMENSION N.A. NOT APPLICABLE THERMO. THERMOSTAT BUILDING DEPT. <br />N/A THK. THICK <br />DR. DOOR THRU. THROUGH ZEPHYRHILLS BUILDING DEPARTMENT <br />DBL. DOUBLE N.I.C. NOT IN CONTRACT 5335 8VICINITY ST <br />N.T.S. NOT TO SCALE TOIL. TOILET ZEPHYRHILLS, FL 33542 1/ I C I N ITY MAP <br />DN. DOWN T.C. TOP OF CURB <br />NO. NUMBER PHONE: (813) 780-0020 <br />D.S. DIRECTIONAL SIGN T.P. TOP OF PAVING <br />DT. DRIVE-THRU 0 OWNER <br />OFF. OFFICE <br />DWG. DRAWING , � PROPOSED WORK T.R. TOP OF ROOF . <br />EA. EACH O.C. ON CENTER <br />T.P. TOP OF PARAPET SCOPE OF PROJECT <br />OFCI OWNER FURNISHED T.S. TOP OF SLAB <br />E.S. EACH SIDE T.W. TOP OF WALL THIS IS A TENANT LEASE AND IMPROVEMENT IN AN EXISTING BUILDING. OPERATION IS A PIZZA <br />CONT R INSTALLED CARRY -OUT RESTAURANT. PARKING, INCLUDING ACCESSIBLE SPACES, IS EXISTING AND IS THE <br />E.I.F.S. EXTERIOR INSULATION & T.S.B. TOP SET BASE <br />FINISH SYSTEM OPN'G. OPENING RESPONSIBILITY OF THE LANDLORD. <br />T. TREAD <br />ELEC. ELECTRICAL OPP. OPPOSITE <br />E.P. ELECTRICAL .PANEL T.S. TUBULAR STEEL � <br />O.A. OVERALL TYP. TYPICAL <br />EL. ELEVATION GRADE) O.A.H. OVERALL HEIGHT U.L. UNDERWRITING <br />ELEV. ELEVATION BLDG) LABORATORIES <br />E.N. EDGE NAIL O.H. OVERHEAD <br />ENCL. ENCLOSURE P.C. POST CAP UNFIN. UNFINISHED _ /fI r <br />DATE <br />E.M.S. ENERGY MANAGEMENT <br />P.C.C. PORTLAND CEMENT CONCRETE U.O.N. UNLESS OTHERWISE rttV1EW ®AHY�` :fLL� <br />NOTED CITY <br />OF ZE � <br />SYSTEM P.G. PAINT GRADE MMINER - Z� <br />E.P.C. ECCENTRIC POST CAP P.H. PIZZA HUT VENT. VENTILATE; VENTILATION PLij4S E ` EQ. EQUAL PR. PAIR VEST. VESTIBULE PREVAILING <br />EQUIP. EQUIPMENT PNL PANEL V.W.C. VINYL WALL COVERING <br />ALL WORK ®RIOA BUIL !!�G CODE, <br />EXH. EXHAUST PART. PARTITION CODES FL <br />EXIST. EXISTING W.C. WATERCLOSET <br />NATIONAL ELECTRIC CODE, <br />PERF. PERFORATION W.P. WATERPROOF AND THE CITY OF ZEPHYRHILLS <br />E.J. EXPANSION JOINT PLAS. PLASTER ORDINANCES <br />EXP. EXPOSED; EXPANSION pTDF PRESSURE TREATED W.W.F. WELDED WIRE FABRIC REVIEW DAB � -1 ' ° <br />EXT. EXTERIOR DOUGLAS FIR W. WIDE; WIDTH CITY OFZEPHYRHILLS R <br />FIN. FINISH PLYWD. PLYWOOD W/ WITH FIRE AND LIFE SAFETY EXAMNE••_-_"_ <br />F.R.P. FIBERGLASS REINFORCED PROP. PROPERTY <br />PANEL W/O WITHOUT <br />F.F. FINISH FLOOR P.L. PROPERTY LINE <br />F.E. FIRE EXTINGUISHER P.V.C. POLY VINYL CHLORIDE WD• WOOD <br />R. RISER W.I.C. WALK-IN COOLER A�YyQ��{p�LLCOMPLYWITI� <br />F.E.C. FIRE EXTINGUISHER CABINET <br />REFR. REFRIGERATOR W.I.F. WALK-IN FREEZER 14FFA CODES AND STANDARDS <br />R.S. ROUGH SAWN <br />N <br />z <br />0 <br />ao <br />a� <br />qj <br />a• <br />c <br />LLI <br />O <br />Z <br />Z <br />W <br />Y <br />FRANCHISEE <br />ONE <br />• <br />• <br />L I C K EL <br />A k C H h `1 E C: [ U h <br />14 West 3rd Strp t qdt� 101 <br />Kansas Ctv. f O fi? 101 <br />TI p <br />t <br />
The URL can be used to link to this page
Your browser does not support the video tag.