My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5915 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5915 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 3:58:39 PM
Creation date
1/21/2025 3:38:22 PM
Metadata
Fields
Template:
Building Plans
Street #
5915
Location
Gall Blvd
Contractor
Osage Contractors LLC
Building Plans - Permit #
20581
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DESCRIPTION OF OPERATION: <br />EXTERIOR SIGNAGE TO BE TURNED ON BY PHOTO <br />CELL. SIGNAGE WILL BE SWITCHED OFF BY TIME <br />SWITCH AT CLOSE. <br />COORDINATE WITH PIZZA HUT CONSTRUCTION <br />MANAGER ON TIME SETTINGS FOR INTERIOR <br />LIGHTING. PHOTO CELL <br />N <br />H B-19 <br />OVERIDE SWITCH. SEE <br />LIGHTING PLAN FOR <br />MORE INFORMATION. <br />ab LOBBY AREA <br />EXIT SIGN/EMERGENCY LIGHTING <br />B-3 �b�-� KITCHEN AREA <br />cam---► KITCHEN AREA <br />EXIT SIGN/EMERGENCY LIGHTING <br />B-11 <br />SIGNAGE <br />SPARE <br />TIME SWITCH: TORK MODEL #DLC400BP <br />LIGHTING CONTROLS SYSTEM TESTING <br />REQUIREMENTS <br />PROVIDE EVIDENCE THAT THE LIGHTING CONTROL SYSTEMS HAVE <br />BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND <br />SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN <br />PROPER WORKING CONDITION IN ACCORDANCE WITH THE <br />CONSTRUCTION DOCUMENTS AND MANUFACTURER'S <br />INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE IN ACCORDANCE <br />WITH SECTIONS C408.3.1.1 AND C408.3.1.2 FOR THE APPLICABLE <br />CONTROL TYPE.. <br />OCCUPANT SENSOR CONTROLS: <br />THE FOLLOWING PROCEDURES SHALL BE PERFORMED: <br />1. CERTIFY THAT THE OCCUPANT SENSOR HAS BEEN LOCATED <br />AND AIMED IN ACCORDANCE WITH MANUFACTURER <br />RECOMMENDATIONS. <br />2. FOR PROJECTS WITH SEVEN OR FEWER OCCUPANT SENSORS, <br />EACH SENSOR SHALL BE TESTED. <br />3. FOR PROJECTS WITH MORE THAN SEVEN OCCUPANT SENSORS, <br />TESTING SHALL BE DONE FOR EACH UNIQUE COMBINATION OF <br />SENSOR TYPE AND SPACE GEOMETRY. WHERE MULTIPLES OF <br />EACH UNIQUE COMBINATION OF SENSOR TYPE AND SPACE <br />GEOMETRY ARE PROVIDED, NOT LESS THAN 10 PERCENT, BUT <br />IN NO CASE LESS THAN ONE, OF EACH COMBINATION SHALL BE <br />TESTED UNLESS THE CODE OCIAL OR DESIGN PROFESSIONAL <br />REQUIRES A HIGHER PERCENTAGE TO BE TESTED. WHERE 30 <br />PERCENT OR MORE OF THE TESTED CONTROLS FAIL, ALL <br />REMAINING IDENTICAL COMBINATIONS SHALL BE TESTED. <br />FOR OCCUPANT SENSOR CONTROLS TO BE TESTED, VERIFY THE <br />FOLLOWING: <br />3.1 WHERE OCCUPANT SENSOR CONTROLS INCLUDE STATUS <br />INDICATORS, VERIFY CORRECT OPERATION. <br />3.2 THE CONTROLLED LIGHTS TURN 0 OR DOWN TO THE <br />PERMITTED LEVEL WITHIN THE REQUIRED TIME. <br />3.3 FOR AUTO -ON OCCUPANT SENSOR CONTROLS, THE LIGHTS <br />TURN ON TO THE PERMITTED LEVEL WHEN AN OCCUPANT <br />ENTERS THE SPACE. <br />3.4 FOR MANUAL -ON OCCUPANT SENSOR CONTROLS, THE <br />LIGHTS TURN ON ONLY WHEN MANUALLY ACTIVATED. <br />3.5 THE LIGHTS ARE NOT INCORRECTLY TURNED ON BY <br />MOVEMENT IN ADJACENT AREAS OR BY HVAC OPERATION. <br />TIME -SWITCH CONTROLS: <br />WHERE TIME -SWITCH CONTROLS ARE PROVIDED, THE FOLLOWING <br />PROCEDURES SHALL BE PERFORMED: <br />1. CONFIRM THAT THE TIME -SWITCH CONTROL IS PROGRAMMED <br />WITH ACCURATE WEEKDAY, WEEKEND AND HOLIDAY <br />SCHEDULES. <br />2. PROVIDE DOCUMENTATION TO THE OWNER OF TIME -SWITCH <br />CONTROLS PROGRAMMING INCLUDING WEEKDAY, WEEKEND, <br />HOLIDAY SCHEDULES, AND SET-UP AND PREFERENCE <br />PROGRAM SETTINGS. <br />3. VERIFY THE CORRECT TIME AND DATE IN THE TIME SWITCH. <br />4. VERIFY THAT ANY BATTERY BACK-UP IS INSTALLED AND <br />ENERGIZED. <br />5. VERIFY THAT THE OVERRIDE TIME LIMIT IS SET TO NOT MORE <br />THAN 2 HOURS. <br />6. SIMULATE OCCUPIED CONDITION, VERIFY AND DOCUMENT THE <br />FOLLOWING: <br />6.1. ALL LIGHTS CAN BE TURNED ON AND OFF BY THEIR <br />RESPECTIVE AREA CONTROL SWITCH. <br />6.2. THE SWITCH ONLY OPERATES LIGHTING IN THE ENCLOSED <br />SPACE IN WHICH THE SWITCH IS LOCATED. <br />7. SIMULATE UNOCCUPIED CONDITION. VERIFY AND DOCUMENT <br />THE FOLLOWING: <br />7.1. NONEXEMPT LIGHTING TURNS OFF. <br />7.2. MANUAL OVERRIDE SWITCH ALLOWS ONLY THE LIGHTS IN THE <br />ENCLOSED SPACE WHERE THE OVERRIDE SWITCH 1S LOCATED TO <br />TURN ON OR REMAIN ON UNTIL THE NEXT SCHEDULED SHUTOFF <br />OCCURS. <br />DAYLIGHT RESPONSIVE CONTROLS: <br />WHERE DAYLIGHT RESPONSIVE CONTROLS ARE PROVIDED, THE <br />FOLLOWING SHALL BE VERIFIED: <br />1. CONTROL DEVICES HAVE BEEN PROPERLY LOCATED, FIELD <br />CALIBRATED AND SET FOR ACCURATE SETPOINTS AND <br />THRESHOLD LIGHT LEVELS. <br />2. DAYLIGHT CONTROLLED LIGHTING LOADS ADJUST TO LIGHT <br />LEVEL SET POINTS IN RESPONSE TO AVAILABLE DAYLIGHT. <br />3. THE LOCATIONS OF CALIBRATION ADJUSTMENT EQUIPMENT <br />ARE READILY ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. <br />DOCUMENTATION REQUIREMENTS: <br />DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING <br />CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF <br />SECTION C405 ARE TO BE PROVIDED TO THE BUILDING OWNER <br />WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE <br />OF OCCUPANCY. <br />QUANTITY <br />LAMP <br />NO. <br />LOCATION <br />MANUFACTURER / CATALOG NUMBER <br />DESCRIPTION <br />MOUNTING <br />VOLT <br />WATT <br />REMARKS <br />NEW <br />EXISTING <br /># <br />TYPE <br />A <br />17 <br />KITCHEN/ <br />PHILIPS / DAY-BRITE <br />2' x 4' LED TROFFER <br />- <br />INCLUDED <br />LAY -IN GRID <br />UNV <br />45 <br />2X4 LED TROFFER WITH 3500K COLOR <br />RESTROOM <br />#2TG48L835-4-FS-02F-UNV <br />TEMPERATURE <br />A5 <br />3 <br />KITCHEN <br />PHILIPS / DAY-BRITE <br />2' x Z LED TROFFER <br />- <br />INCLUDED <br />LAY -IN GRID <br />UNV <br />43.5 <br />2X2 LED TROFFER WITH 3500K COLOR <br />#2TG38L835-2-FS-02F-UNV <br />TEMPERATURE <br />C <br />13 <br />ENTRY <br />ACCUSERV / 00395-016 / CT6FB /RC6-12W <br />DOWNLIGHT <br />- <br />LED <br />CEILING <br />120 <br />12 <br />TRIM: BLACK <br />D <br />3 <br />ENTRY <br />ACCUSERV / ITEM: BES00298-105 <br />CORD HUNG PENDANT <br />1 <br />9.5W Al LED <br />CEILING <br />120 <br />9.5 <br />FINISH: CORD HUNG PENDANT WITH <br />WITH 18W GU24 BASE <br />2,700K <br />RED SAND GLASS SHADE <br />E <br />3 <br />WALK-IN <br />SUPPLIED BY WALK-IN COOLER/FREEZER <br />- <br />- <br />- <br />SURFACE <br />- <br />- <br />EM1 <br />2 <br />ENTRY <br />EXITRONIX / NFT-B-G2 <br />EMERGENCY LIGHT <br />- <br />INCLUDED <br />WALL <br />120 <br />- <br />EMERGENCY FIXTURE WITH 90 MINUTE <br />EMERGENCY BATTERY BACKUP. FINISH: BLACK <br />EM2 <br />7 <br />KITCHEN <br />EXITRONIX / NFT-W-G2 <br />EMERGENCY LIGHT <br />- <br />INCLUDED <br />WALL <br />120 <br />- <br />EMERGENCY FIXTURE WITH 90 MINUTE <br />EMERGENCY BATTERY BACKUP. FINISH: WHITE <br />EM3 <br />3 <br />EXTERIOR <br />ACCUSERV / ITEM: CAMN/LX6-DB <br />EXTERIOR <br />- <br />6W XENON <br />WALL <br />120 <br />- <br />EMERGENCY FIXTURE <br />EMERGENCY LIGHT <br />WET LOCATION RATED <br />Ki <br />1 <br />ENTRY <br />BEST LIGHTING PRODUCTS <br />LED EXIT SIGN <br />- <br />LED <br />CEILING <br />120 <br />3 <br />BLACK EXIT FIXTURE WITH EMERGENCY BATTERY. <br />EZXTEU-2-R-B-EM <br />SEE LIGHTS FIXTURE SCHEDULE NOTE #2. <br />K2 <br />6 <br />KITCHEN <br />BEST LIGHTING PRODUCTS <br />LED EXIT SIGN <br />- <br />LED <br />CEILING <br />120 <br />3 <br />WHITE EXIT FIXTURE WITH EMERGENCY BATTERY. <br />EZXTEU-2-R-W-EM <br />SEE LIGHTS FIXTURE SCHEDULE NOTE #2. <br />J <br />3 <br />ENTRY <br />ACCUSERV / ITEM: 2001-002 <br />TRACK LIGHT HEADS <br />1 <br />PAR20 LED <br />TRACK <br />120 <br />8 <br />FINISH: BLACK <br />J132 <br />1 <br />ENTRY <br />ACCUSERV / ITEM:6048BK <br />2' TRACK <br />- <br />- <br />CEILING <br />- <br />- <br />FINISH: BLACK <br />REFER TO LIGHT FIXTURE SCHEDULE NOTE #3 <br />JB4 <br />2 <br />ENTRY <br />ACCUSERV / ITEM:60486K <br />4' TRACK <br />- <br />- <br />CEILING <br />- <br />- <br />FINISH`. BLACK <br />REFER TO LIGHT FIXTURE SCHEDULE NOTE #3 <br />W1 <br />0 <br />EXTERIOR <br />RAB / ITEM: WP2H1500T/PC <br />WALL PACK- <br />- <br />ED17 <br />WALL <br />120 <br />185 <br />SUFFACE MOUNT FIXTURE <br />BRONZE FINISH <br />150W <br />AT 8'-0" AFF TO CENTER <br />ALL LIGHT FIXTURES ON LIGHT FIXTURE SCHEDULE FURNISHED BY OWNER AND INSTALLED <br />BY ELECTRICAL CONTRACTOR. <br />LIGHTING FIXTURE CONTACTS: <br />ACCUSERV EQUIPMENT & SUPPLY <br />3865 PRODUCE RD., SUITE #208, LOUISVILLE, KY 40218, <br />PHONE: 877-707-7378, FAX: 502-961-0357. <br />1. OWNER WILL PROVIDE LIGHT FIXTURES WITH ELECTRONIC BALLASTS. COMPACT <br />FLUORESCENT ELECTRONIC BALLASTS SHALL HAVE END -OF -LIFE PROTECTION CIRCUIT TO <br />PREVENT WELDING OF LAMPS IN SOCKETS OR LAMP BREAKAGE. SEE SPECIFICATIONS. <br />2. OWNER WILL PROVIDE ARROWS AND FACES AS INDICATED ON THE DRAWINGS. FIXTURES ARE <br />PROVIDED WITH REMOVABLE CHEVRONS FOR DIRECTIONS INDICATED ON PLAN. <br />3. OWNER WILL PROVIDE TRACK, END FEEDS, AND COUPLING DEVICES IN QUANTITIES AS <br />REQUIRED TO FORM THE TRACK LENGTHS SHOWN. REFER TO THE PLANS FOR TRACK <br />LOCATION. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND ELEVATIONS FOR <br />EXACT LOCATIONS OF LIGHTING FIXTURES. <br />4. ELECTRICAL CONTRACTOR SHALL VERIFY ALL FIXTURE LOCATIONS WITH ARCHITECTURAL <br />PLANS. <br />5. ELECTRICAL CONTRACTOR SHALL INSTALL ALL CEILING MOUNTED LIGHTING FIXTURES IN <br />LOCATIONS AS INDICATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. <br />6. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. <br />7. CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING HARDWARE. <br />8. SPEAKERS INSTALLED BY OTHERS. <br />9. VERIFY LOCATION OF NEW SWITCH BANK WITH NPC FACILITES/PROJECT MANAGER. <br />INTERIOR LIGHTING & EXTERIOR SIGNAGE CONTROL DIAGRAM 1 6 1 LIGHTING FIXTURE SCHEDULE 1 5 1 LIGHT FIXTURE SCHEDULE NOTES 1 4 1 <br />NOTE: <br />ALL CEILING FIXTURES AND <br />PENETRATIONS TO CONFORM TO <br />ANSI/UL 263 STANDARDS. <br />ELECTRICAL LIGHTING PLAN <br />1 /4" = 1'-0" <br />2 <br />O COOLER/FREEZER LIGHTS FURNISHED BY MANUFACTURER. CIRCUIT AS SHOWN. NO <br />AUTOMATIC CONTROLS FOR THIS SPACE ARE REQUIRED SINCE THE LIGHTS HAVE AN <br />EFFICACY OF MORE THAT 40 LM/W. <br />O2 PROVIDE TIME SWITCH, EXTERIOR PHOTOCELL SENSOR AND LIGHTING CONTACTOR AS <br />SHOWN IN DETAIL 6 ON THIS SHEET. MOUNT TIME SWITCH AND LIGHTING CONTACTOR <br />ADJACENT TO PANELBOARD'B' AND MOUNT EXTERIOR PHOTOCELL SENSOR ON ROOF PER <br />MANUFACTURER LITERATURE. <br />O VERIFY EXACT LOCATION OF SWITCH BANK WITH NPC FACILITIES/PROJECT MANAGER. <br />® SIGNAGE DISCONNECT SWITCH; NEMA 3R, LOCKABLE. EXACT LOCATION TO BE DETERMINED <br />IN FIELD.. <br />O CONNECT HOOD LIGHTING WITHIN OVEN AND FRYER HOODS TO HOOD CONTROL PANEL <br />CONTROL CIRCUIT. COORDINATE ALL WIRING AND REQUIRED CONNECTION WITH HOOD <br />MANUFACTURER. <br />MOUNT EXTERIOR EMERGENCY EXIT LIGHTING FIXTURE @ 96" A.F.F. ON FACE OF EXTERIOR <br />WALL. CIRCUIT AS INDICATED. COORDINATE EXACT LOCATION WITH BUILDING OWNER AND <br />TENANT. <br />O PROVIDE WALL MOUNTED OCCUPANCY SENSOR AS SHOWN ON PLANS FOR CONTROL OF <br />RESTROOM LIGHT AND EXHAUST FAN. WATTSTOPPER MODEL# PW-100. <br />® PROVIDE OVERRIDE SWITCH FOR TIMESWITCH: TORK MODEL#SS410. SWITCH SHALL BE <br />PROGRAMMED TO OVERRIDE TIMESWITCH FOR A MAXIMUM OF 2 HOURS. LABEL SWITCH <br />WITH ZONES CONTROLLED, <br />KEYNOTES 1 3 1 <br />R-? R-.q R-:q <br />a b c <br />0 0 0 <br />NOTE: VERIFY LOCATION OF NEW SWITCH BANK W/ NPC <br />FACILITIES/PROJECT MANAGER. <br />NOTE: PROVIDE PILOT LIGHTS FOR SWITCHES NOTED <br />WITH A "PU NEXT TO IT. PILOT LIGHTS ARE REQUIRED <br />FOR ALL SWITCHES CONTROLLING LIGHTS FIXTURES <br />THAT ARE NOT VISIBLE FROM SWITCH LOCATION. <br />SWITCH BANK 1 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.