Laserfiche WebLink
a <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />T.O.P._ — — <br />HDR. HGT._ _ <br />C <br />-r0, <br />00 ; <br />r` <br />2ND FIN. FLR_--- <br />T.O.M____ <br />T.O.M. GARS _ <br />/ENTRY <br />HDR. HGT_ <br />SCORED <br />STUCCO BANDS <br />00 0 <br />EO <br />Cfl <br />CN CO <br />CN <br />FIN. FLR. <br />T.O.M. <br />— ------ — ---- ---- — — <br />O.M. @ GAR. 177-7-77-7 <br />ENTRY <br />HDR. HGT. <br />SCORED STUCCO <br />BANDS <br />EXTERIOR PLASTER <br />ON FRAME <br />TEXTURED <br />.CEMENTITIOUS <br />—FINISH ON CMU <br />—SCORED STUCCO <br />BANDS <br />16070 OVERHEAD DOOR <br />FRONT ELEVATION - A <br />SCALE: 1 /4" = V-0" <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS 1 <br />12 <br />5 5 <br />6" <br />SCORED <br />STUCCO <br />BANDS <br />SILL DETAIL <br />SCALE: 3/4" = 1'-0" <br />SCORED <br />STUCCO <br />BANDS <br />HEAD DETAIL <br />SCALE: 3/4" = 1'-0" <br />SCORED <br />STUCCO` <br />BAND <br />L. 1'-6" >, <br />DECO SHUTTER <br />SCALE: 3/4" = 1'-0" <br />— — — - <br />- ------------------------------ ------ <br />FLASHING---------------------- — — ------------------------------------- <br />CJ / WEEP <br />FIN. FLR.___t----------------------�— -- <br />35 SH <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />--T------ <br />RIGHT ELEVATION - A <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant, <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />C. <br />C <br />�o <br />a s <br />;Q <br />C 2 <br />> E � <br />> ra <br />-CL <br />E <br />`o c <br />caSU <br />,C <br />i�',S,1S!l6lFOlfir`j�I <br />1 <br />L •,- <br />_ < <br />= <br />O F S • <br />��� <br />E S <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W �E <br />O <br />a 3 <br />,4 <br />V M0 m N W <br />cc)Z <br />6 <br />��C <br />N N C, J <br />0W <br />o <br />c <br />Z m 0) <br />o 0 <br />y @0 <br />W <br />��6rj°' m w <br />J <br />Z <br />LL <br />U0W <br />CN CO ZO <br />O <br />CNZ 1.O U <br />U <br />❑❑ <br />Hal <br />Z N [h <br />O O <br />N <br />� <br />J <br />o_ <br />N <br />C7 <br />to z <br />a--+ <br />LU <br />O W a <br />(/ ! -- N <br />�t/) ZD <br />U <br />r, r <br />� J <br />8 <br />x <br />U R <br />U) <br />. <br />�® <br />d <br />JZ <br />w <br />M <br />G <br />o� <br />Z <br />Z <br />U__ <br />E <br />�o <br />o0 <br />Zo <br />Q <br />EN <br />O <br />Fz <br />oa <br />tC6 N <br />E <br />20. <br />so <br />0< <br />rO <br />O <br /><o <br /><o <br />�Z <br />ra <br />2Y <br />Wm 2 <br />Z <br />Z <br />M J <br />m 101 <br />¢ w <br />. <br />oa <br />�z <br />z <br />ao <br />�w <br />W <br />a <br />m <br />w� <br />¢o <br />Fk <br />M <br />� <br />I <br />0 H <br />za <br />i;3 <br />o O <br />121) M <br />J <br />Orn <br />m <br />0 <br />00 <br />CO <br />O <br />� r <br />r <br />� <br />Q <br />0,LO <br />Y <br />N <br />f— <br />m <br />O <br />r%_ <br />O <br />N <br />Q <br />T <br />ai <br />N <br />00N ^ <br />o <br />z <br />B <br />ro <br />d <br />E <br />U Q p <br />_ <br />D <br />JOB <br />NO: 22-08307 <br />SCALE : AS NOTED <br />SHEEP' NO. <br />2.1 <br />