My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6462 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6462 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 6:02:21 PM
Creation date
1/21/2025 3:40:06 PM
Metadata
Fields
Template:
Building Plans
Street #
6462
Location
Beverly Hills Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
5185
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1ru.u...�. �t_to ���u�■I�IlU �.1�a11W:.�:iLL <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANELCENTER <br />10 #14 to lights & outlets <br />NEMA 1 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 #10 to WH <br />10 #8 to Range <br />00 #6 to HVAC <br />So=zro <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSUUL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FE7W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G .F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FiF <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />eE--, <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />49 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />T <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />(✓ T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />---------------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />IN ATTIC SPACE <br />I SWITCH & LIGH1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L-------------------------------------- <br />I <br />I <br />BEDROOM 5 <br />%J ROUGH -IN FOR <br />�OPT. CLG. FAN/ <br />LIGHT PRE-WIR <br />G <br />I <br />1 <br />1 <br />/ I <br />ROUGH -IN FOR / <br />OPT. CLG. FAN/ / <br />LIGHT PRE-WIRI�/ <br />12/ <br />A <br />6 . <br />v <br />BEDROOM 6 <br />I\ <br />�/ i \\ I � (§d <br />I/ I <br />I � <br />ROUGH-INFOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />1% <br />_ I <br />�Z/ <br />--- ' LOFT <br />I / <br />r <br />C.M./0S.D. <br />i I <br />1 i <br />I I <br />I I <br />BEDROOM 3 <br />I I <br />I 1 <br />I <br />I /% ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />I LIGHT PRE -WIRE <br />6/ <br />db <br />E"/ r1l <br />1 <br />I I / <br />1 <br />I I / <br />I <br />I <br />— I <br />I <br />I <br />S.D. I <br />I <br />HI <br />I I <br />I— — —1 I <br />----------- L --- j <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4rr-1 r^ou <br />cam► <br />C� <br />e'd <br />C <br />w �c <br />® <br />® m <br />G CV � <br />a) m <br />°Ci 3 cc <br />L <br />a <br />fO <br />�. <br />.r <br />LZ U <br />N <br />N <br />0 <br />N <br />M <br />n <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with <br />the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. <br />Engineers signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />V) <br />W <br />a <br />E <br />o co 8 <br />ci <br />o <br />(V p <br />� ,�., CD�N m <br />NN <br />a <br />j u- LL a <br />03 <br />Z <br />Lu <br />rmc <br />1 <br />2 <br />W <br />�"'9.- O <br />5 6 N �2 <br />W <br />m W <br />IL <br />Z <br />Co 0 <br />L0 Cl) Z Q <br />Z <br />N 00 <br />W <br />El <br />CD r <br />Z N ch <br />o g <br />z � N <br />� � Z <br />J — <br />rid <br />TM <br />tJ 1 <br />— N <br />Z Sl <br />V,J <br />V o <br />w <br />a--+ <br />r,u <br />� <br />V <br />O <br />) <br />—� <br />U1711 <br />LU g <br />c <br />U <br />J <br />RioW <br />r-- — E <br />s 3 <br />� I <br />U o M <br />tffil <br />14 <br />o <br />w <br />M <br />h <br />o <br />z <br />u- <br />E <br />E <br />wQ <br />00 <br />zo <br />QN <br />z® <br />co <br />o <br />M <br />o¢ <br />j00 <br />o� <br />Z <br />c> E <br />N <br />ao <br />ao <br />WZ <br />wz <br />It <br />¢� <br />Cn C <br />O V <br />Z <br />N m <br />F <br />Q W <br />Z <br />W< <br />N � <br />U <br />o� <br />�0 <br />ao <br />0�~ <br />aZ <br />o <br />zy <br />a3 <br />F <br />Xo <br />CEO <br />�I <br />w <br />C) <br />a I=- <br />0 <br />C O <br />U ! <br />o) <br />cu <br />�\ <br />Q <br />0 <br />co <br />C <br />� <br />T <br />N <br />m <br />m <br />U! <br />Q <br />Q <br />N <br />� <br />O <br />M <br />LO <br />� <br />M <br />Q <br />r <br />6 <br />LO <br />o <br />Z <br />E <br />M <br />N <br />ti <br />o <br />c� <br />m <br />¢ fl <br />JOB <br />NO: <br />22-06461 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.