Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />to lights & outlets <br />to appliances and GFI <br />to WH <br />a Range <br />O HVAC <br />MAIN <br />0150=20 <br />tF200=4'10 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />;Q% <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />kB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />ko <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />P TELEVISION (OPTIONAL) <br />T©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�]M ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />ti T J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK—UP. ALL SMOKE DETECTORS TO BE <br />ARC —FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />DISC. <br />COMP. <br />WP <br />GFI <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />I` <br />3u I <br />k N <br />4n <br />o r <br />PLUMBING RISER <br />SCALE: NITS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />UNIT 1397 - ELECTRICAL PLAN <br />SCALE: 1 /4"= V-0" <br />W <br />A� <br />1 w <br />x <br />V N <br />ca. X <br />CL, ,U_ t1 <br />N -C <br />co <br />�- a) <br />C <br />6- <br />0 .0 <br />as Q* <br />�' G) <br />tU <br />0 0 <br />3 U <br />`- tf <br />a � 9- Lu <br />CV <br />N <br />0 <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />a <br />E <br />o gg <br />/a <br />® <br />Ncb o <br />0 m N t <br />���� <br />N CD� � <br />/ <br />V' <br />ts LL W <br />Lu a <br />ti a Y <br />Z <br />M <br />m� � <br />r103\ <br />W <br />N <br />W <br />Z <br />IL <br />0W m W <br />,ro M Z c <br />ZN <br />OU < <br />W <br />O❑ <br />1 <br />z Na <br />o <br />z N <br />z � � <br />r/ <br />J <br />E3 <br />U ^ <br />' <br />^ ' <br />N <br />M <br />00 <br />VJ <br />_ � <br />— <br />W <br />U <br />LU o <br />U) <br />uaa <br />U � <br />w <br />r J <br />0 p <br />8 <br />mi` <br />t 4 <br />_ ; <br />z. <br />U 0 <br />U)uD 0 <br />® <br />0 <br />N <br />1� <br />W <br />Z <br />M <br />co <br />J <br />0 Z <br />o S <br />Z <br />4 <br />ai EE <br />O <br />o <br /><zoN <br />O -0 <br />> o <br />Z <br />co <br />' 0 <br />V n, <br />t— <br />CD Eo <br />x g <br />&¢ <br />¢z <br />D' <br />o1 <br />Wz <br />GV fu <br />L <br />o <br />�¢ o <br />w Lu <br />m <br />' <br />C <br />y <br />V <br />0 <br />Do <br />0 <br />Z <br />J <br />wai <br />U <br />QW <br />1` 0z <br />N <br />w 3 <br />0 <br />Z <br />d0 <br />V <br />w <br />o <br />�w <br />z= <br />C' <br />o� <br />Z <br />3 <br />j <br />O <br />J <br />� ¢ <br />. 0 <br />.IO <br />x <br />III <br />CD <br />z it <br />a <br />00 ~ <br />0 <br />ACV <br />>U-) <br />Cn <br />ui <br />rn <br />O <br />O <br />\ <br />0 <br />ILO <br />it\ <br />t <br />CD <br />O <br />M <br />co <br />ai <br />60 <br />r <br />U) m <br />O <br />Q <br />4_j <br />N <br />N <br />O <br />CO <br />I <br />_N11.0 <br />r <br />E <br />M <br />3 0) <br />N <br />z <br />z <br />r <br />E <br />t6 <br />coa <br />U � <br />q p <br />3 <br />JOB <br />NO: 22-03338-03333 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />