MISCF7 I ANE0L1S <br />1. THE STRUCTURAL SYSTEM IS UNSTABLE UNTIL ALL CONNECTIONS <br />HAVE BEEN MADE AND ALL CONCRETE HAS REACHED ITS MINIMUM <br />DESIGN STRENGTH, AS SHOWN IN THE STRUCTURAL DOCUMENTS. <br />2. THE STRUCTURAL DOCUMENTS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE AND DO NOT INDICATE THE METHOD OR MEANS OF CONSTRUCTION. <br />THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, <br />METHODS, PROCEDURES, TECHNIQUES AND SEQUENCES. <br />3. CONTRACTOR TO SUPPORT, BRACE AND SECURE EXISTING STRUCTURE AS <br />REQUIRED. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SAFETY OF <br />THE BUILDING DURING CONSTRUCTION. <br />4. APPLICABLE BUILDING CODE: FLORIDA BUILDING CODE 6TH EDITION (2017). <br />5. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE <br />FLORIDA BUILDING CODE 6TH EDITION (2017). <br />6. DESIGN GRAVITY LOADS: <br />AREA SUPERIMPOSED LIVE LOAD (FBC, TABLE 1607.1) <br />ROOF 20 PSF <br />FLOOR 100 PSF (SLAB -ON -GROUND) <br />STEEL CANOPY 20 PSF <br />AREA DEAD LOAD <br />ROOF 20 PSF <br />7. ULTIMATE DESIGN WIND SPEED = 137 MPH (FBC, FIGURE 1609.3.1) <br />ASD NOMINAL DESIGN WIND SPEED = 106 MPH (FBC, TABLE 1609.3.1) <br />RISK CATEGORY II (FBC, TABLE 1604.5) <br />REFER TO 1/SO.1 FOR WIND PRESSURES AND MORE INFO. <br />8. SEISMIC DESIGN: N/A <br />9. SNOW DESIGN: N/A <br />10, FLOOD DESIGN: N/A <br />11. COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH THE <br />ARCHITECTURAL DRAWINGS. DO NOT SCALE DRAWINGS. <br />12. CONTACT ENGINEER WITH ANY QUESTIONS OR DISCREPANCIES FOUND ON <br />DRAWINGS. <br />MAIMIAL ANID�SHOP DRAIMING SUBMITTALS <br />1. SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR AND MARKED <br />"APPROVED" PRIOR TO SUBMITTING TO THE ARCHITECT. NON -CONFORMING <br />SUBMITTALS WILL BE RETURNED WITHOUT REVIEW. <br />2. SUBMIT SHOP DRAWINGS AS REQUIRED HEREIN IN DIGITAL PDF FORMAT <br />WITH A HIGH -RESOLUTION. ALLOW FOR TWO WEEKS REVIEW <br />TIME AFTER RECEIPT OF SUBMITTALS BY THIS FIRM. ALL SUBMITTALS <br />SHALL BE SIGNED/SEALED BY THE SPECIALTY OR DELEGATED ENGINEER, <br />AS NOTED BELOW. REFER TO THE SPECIFIC SECTION ON THIS SHEET FOR <br />MORE INFORMATION REGARDING THE SHOP DRAWING SUBMITTAL. <br />a) STRUCTURAL STEEL <br />b) CONCRETE MIX DESIGN <br />c) CONCRETE REINFORCING STEEL <br />d) MASONRY REINFORCING STEEL <br />e) PRECAST CONCRETE MASONRY <br />f) STEEL JOISTS AND GIRDERS <br />g) METAL DECK <br />h) COLD -FORMED METAL FRAMING DATA <br />3. CONTRACTOR SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR <br />ERRORS OR OMISSIONS IN SHOP DRAWINGS OR MIX DESIGNS BY THE <br />ENGINEER'S REVIEW THEREOF. <br />4. SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE <br />DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE <br />CONTRACT DOCUMENTS AS TO QUANTITY, LENGTHS, DIMENSIONS, ETC. <br />5. SHOP DRAWING REVIEW COMMENTS BY THIS FIRM SHALL BE TRANSMITTED <br />TO THE ARCHITECT OF RECORD ONLY FOR THEIR REVIEW. THE ARCHITECT <br />WILL TRANSMIT AN ELECTRONIC COPY OF ALL REVIEWED SUBMITTALS TO <br />THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR DISTRIBUTING <br />THE REVIEWED SHOP DRAWINGS TO THE IMPACTED TRADES OR SUBCONTRACTORS. <br />6. CHANGES AND ADDITIONS MADE ON SHOP DRAWING RE -SUBMITTALS SHALL BE <br />CLEARLY FLAGGED AND NOTED AS SUCH. THE PURPOSE OF THE RE -SUBMITTAL <br />SHALL BE NOTED IN THE SUBMITTAL OR ON A TRANSMITTAL ATTACHED TO <br />THE SHOP DRAWINGS. A RE -REVIEW OF THE REVISED SHOP DRAWING <br />SUBMITTAL WILL BE LIMITED TO THOSE ITEMS CAUSING THE RE -SUBMITTAL. <br />THE CONTRACTOR IS RESPONSIBLE FOR THE COSTS ASSOCIATED WITH <br />RE -SUBMITTING MULTIPLE (MORE THAN ONE) SHOP DRAWING SUBMITTALS <br />AT THE ENGINEER OF RECORD'S HOURLY RATES. <br />STE WOW <br />1. A SUBSURFACE INVESTIGATION HAS BEEN COMPLETED AT THE PROJECT <br />SITE BY ECS FLORIDA, LLC, PROJECT NO. 41:2016, REVISION 1 <br />SOIL BORING LOGS AND SITE PREPARATION PROCEDURES ARE INCLUDED <br />IN THE PROJECT SOILS REPORT, DATED FEBRUARY 16, 2018 <br />WHICH IS AN INTEGRAL PART OF THESE CONTRACT DOCUMENTS. <br />2. ALL SITE WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE <br />PROJECT SOILS REPORT. <br />3. DESIGN SOIL BEARING PRESSURE = 2,500 PSF. <br />4. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM <br />THE FOLLOWING TESTS: <br />a) ONE DENSITY TEST FOR EACH 2,000 SQUARE FEET OF COMPACTED <br />SUBGRADE AND COMPACTED FILL. <br />b) ONE DENSITY TEST AT EACH COLUMN FOOTING. <br />c) ONE DENSITY TEST PER 50 FEET OF WALL FOOTING. <br />5. ONE COPY OF ALL TEST REPORTS SHALL BE SENT DIRECTLY TO OWNER, <br />ARCHITECT, STRUCTURAL ENGINEER, AND GENERAL CONTRACTOR. <br />6. FOUNDATION WALLS THAT RETAIN EARTH SHALL BE BRACED AGAINST <br />BACKFILLING PRESSURES UN11L FLOOR SLABS AT TOP AND BOTTOM ARE <br />IN PLACE. <br />7. THE SIDES OF FOOTINGS MAY BE EARTH -FORMED IF THE EXCAVATION <br />CAN BE KEPT VERTICAL, CLEAN, AND STABLE; OTHERWISE, PLYWOOD <br />FORMS MUST BE USED. <br />CASTIN PLACE CONCRETE <br />1. CONCRETE TO BE NORMAL WEIGHT WITH THE FOLLOWING MINIMUM <br />COMPRESSIVE STRENGTHS AT 28 DAYS: <br />a) FOOTINGS, SLAB -ON -GRADE .......... .3000 PSI <br />b) BEAMS ......................... ....... - ............ 4000 PSI <br />2. CONCRETE SHALL BE READYMIX PER ASTM C94: <br />a) PORTLAND CEMENT - ASTM C 150 <br />b) AGGREGATES - ASTM C33 (3/4" MAX.) <br />c) NO CALCIUM CHLORIDE <br />d) AIR ENTRAINING - ASTM C260 <br />e) WATER REDUCING - ASTM C494 <br />f) FLYASH - ASTM C618 CLASS F (20% MAXIMUM BY WEIGHT) <br />g) WATER - CLEAN AND POTABLE <br />3. REINFORCING STEEL: ASTM A615 GRADE 60. <br />4. REQUIRED SLUMP RANGE = 3" TO 5". <br />5. WELDED WIRE FABRIC: ASTM A-185. FURNISH IN SHEETS, NOT ROLLS. <br />6. MOISTURE/VAPOR RETARDER: 15 MIL POLYETHYLENE. LAP 6" AND TAPE ALL <br />JOINTS. <br />7. CODES AND STANDARDS: (CURRENT EDITION) <br />ACI 301 "SPEC FOR STRUCTURAL CONCRETE FOR BUILDINGS." <br />ACI 305 "RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING." <br />ACI 318 "BLDG. CODE REQUIREMENTS FOR REINF. CONCRETE.' <br />ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT." <br />8. MINIMUM LAP SPLICE = 30 BAR DIAMETERS UNLESS NOTED OTHERWISE. <br />9. PROVIDE PROPERLY TIED SPACERS, CHAIRS, BOLSTERS, ETC, AS <br />REQUIRED AND NECESSARY TO ASSEMBLE, PLACE AND SUPPORT ALL <br />REINFORCING IN PLACE, USE WIRE BAR TYPE SUPPORTS COMPLYING <br />WITH CRSI RECOMMENDATIONS. USE PLASTIC TIP LEGS ON ALL EXPOSED <br />SURFACES. <br />10. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES, <br />AND SLAB RECESSES AS REQUIRED BY OTHER TRADES BEFORE CONCRETE <br />IS PLACED. NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN <br />BEAMS, UNLESS APPROVED BY THE ENGINEER, <br />11. CONTRACTOR SHALL VERIFY EMBEDDED ITEMS, INCLUDING BUT NOT <br />LIMITED TO ANCHOR BOLTS, BOLT CLUSTERS, WELD PLATES, ETC..., <br />BEFORE PLACING CONCRETE. NOTIFY ENGINEER OF ANY CONFLICTS WITH <br />REPAR. <br />12. SEE ARCHITECTURAL DRAWINGS FOR REQUIRED CONCRETE FINISHES. <br />13. ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING <br />OPERATIONS IN ACCORDANCE WITH ONE OF THE FOLLOWING METHODS: <br />a) APPLY A 30% SOLIDS LIQUID MEMBRANE FORMING CHEMICAL CURING <br />COMPOUND IN ACCORDANCE WITH ASTM C-309. <br />b) PROVIDE CONTINUOUS MOISTURE TO CONCRETE IN ACCORDANCE WITH <br />ACI 301. <br />14. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROPER DESIGN AND <br />CONSTRUCTION OF ALL FORMWORK, SHORING, AND RESHORING. DESIGN <br />SHALL BE PERFORMED BY A LICENSED FLORIDA ENGINEER. <br />15. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM <br />THE FOLLOWING CONCRETE TESTS ON SITE. <br />a) CYLINDER STRENGTH TESTS - ASTM C39; ONE SET OF FOUR <br />CYLINDERS FOR EACH 50 CUBIC YARDS OR FRACTION THEREOF. <br />TEST ONE CYLINDER AT 7 DAYS AND TWO AT 28 DAYS. HOLD THE <br />FINAL CYLINDER IN RESERVE. <br />b) SLUMP TESTS - ASTM C143 <br />16, ONE COPY OF ALL TEST REPORTS SHALL BE SENT DIRECTLY TO OWNER, <br />ARCHITECT, STRUCTURAL ENGINEER, AND GENERAL CONTRACTOR. <br />17. RESTRICT THE ADDITION OF MIX WATER AT THE JOB SITE. DO NOT <br />ADD WATER WITHOUT THE APPROVAL OF THE GENERAL CONTRACTOR AND <br />DO NOT EXCEED SLUMP LIMITATIONS OR TOTAL ALLOWABLE WATER TO <br />CEMENT RATIO. USE COLD WATER FROM THE TRUCK TANK AND REMIX TO <br />ACHIEVE CONSISTENCY. TEST REPORTS SHALL INDICATE QUANTITY OF <br />WATER ADDED AT THE JOB SITE. ALL TESTS SHALL BE PREPARED <br />AFTER THE ADDITION OF WATER TO THE MIX, <br />18. MAXIMUM WATER TO CEMENT RATIO WHEN NO BACK-UP DATA IS <br />AVAILABLE: <br />a) 4000 PSI, 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.44 <br />MAXIMUM (NON -AIR -ENTRAINED), 0.36 MAXIMUM (AIR -ENTRAINED). <br />b) 3000 PSI, 28-DAY COMPRESSIVE STRENGTH; W/C RATIO, 0.58 <br />MAXIMUM (NON -AIR -ENTRAINED), 0.47 MAXIMUM (AIR -ENTRAINED). <br />19. REINFORCING BAR COVER: <br />a) FOOTINGS 3" <br />b) BEAMS 1-1/2" <br />20. CONCRETE SHALL BE PLACED WITHIN 90 MINUTES OF BATCH TIME. <br />21. WHERE BAR LENGTHS ARE GIVEN ON DRAWINGS, LENGTH OF HOOK, IF <br />REQUIRED, IS NOT INCLUDED. <br />22. PROVIDE COMMERCIAL FORM COATING COMPOUNDS THAT WILL NOT BOND, <br />STAIN, OR ADVERSELY AFFECT CONCRETE SURFACES. WET FORMS BEFORE <br />PLACING CONCRETE. <br />23. ALL CONCRETE SHALL BE CONSOLIDATED IN PLACE USING INTERNAL <br />VIBRATORS. <br />24. REPAIR AND PATCH DEFECTIVE AREAS WITH CEMENT MORTAR <br />IMMEDIATELY AFTER REMOVAL OF FORMS, EXCEPT WHERE REINFORCING <br />IS VISIBLE. CONTACT STRUCTURAL ENGINEER FOR EVALUATION OF <br />EXPOSED REINFORCING. <br />25. PROVIDE CORNER BARS AT ALL BEAM AND WALL FOOTING CORNERS TO <br />MATCH HORIZONTAL BARS. <br />26. SUBMITTALS: <br />a) SUBMIT PROPOSED CONCRETE MIX DESIGN PRIOR TO <br />CONSTRUCTION, INCLUDING BACKUP DATA IN ACCORDANCE WITH <br />ACI 301-99 CHAPTER 4, SECTION 4.23, EXCLUDING SECTION <br />4.2.3.48, INDICATING WHERE CONCRETE IS TO PLACED WITHIN <br />THE STRUCTURE. <br />b) SUBMIT DETAILED SHOP DRAWINGS OF REINFORCING BARS SHOWING <br />NUMBER, SIZE, AND LOCATION. INCLUDE BAR LISTS AND BEND <br />DIAGRAMS. <br />c) SUBMIT FORMWORK AND SHORING DRAWINGS TO LOCAL BUILDING <br />DEPARTMENT WHEN REQUIRED BY FLORIDA THRESHOLD LAW. <br />27. STEP AND SLOPE ALL WALKWAYS AWAY FROM THE BUILDING. <br />MASONRY <br />1. MASONRY INSPECTION SHALL BE PROVIDED BY A QUALIFIED AGENT IN <br />ACCORDANCE WITH ACI 530.1-1.6, INSPECTION SERVICES SHALL <br />INCLUDE, BUT ARE NOT LIMITED TO, THE WORK IN PROGRESS AS WELL <br />AS MATERIALS, EQUIPMENT, AND PROCEDURES. <br />2. HOLLOW LOAD BEARING UNITS SHALL CONFORM TO ASTM C90, NORMAL <br />WEIGHT, TYPE II. MINIMUM NET COMPRESSIVE UNIT STRENGTH = 1900 <br />PSI. (NET AREA COMPRESSIVE MASONRY STRENGTH f m = 1500 PSI). <br />3. MORTAR SHALL BE TYPE M OR S AND CONFORM TO ASTM C270 <br />(PROPORTION OR PROPERTY SPECIFICATION), <br />4. COARSE GROUT SHALL CONFORM TO ASTM C476: <br />a) 3000 PSI AT 28 DAYS. <br />b) 1/4" MAXIMUM AGGREGATE. <br />c) 8" - 11" SLUMP. <br />5. CODES AND STANDARDS: <br />ACI 530/ASCE 5 "BUILDING CODE REQUIREMENTS FOR MASONRY <br />STRUCTURES" <br />ACI 530.1/ASCE 6 "SPECIFICATIONS FOR MASONRY STRUCTURES" <br />6. PLACE ALL MASONRY IN RUNNING BOND WITH 3/8" MORTAR JOINTS. <br />PROVIDE COMPLETE COVERAGE FACE SHELL MORTAR BEDDING, <br />HORIZONTAL AND VERTICAL. FULLY MORTAR WEBS IN ALL COURSES OF <br />PIERS, COLUMNS, AND PILASTERS AND ADJACENT TO GROUTED CELLS. <br />7. A REINFORCED CONCRETE TIE BEAM SHALL BE PROVIDED IN ALL WALLS <br />SHOWN ON THE STRUCTURAL DRAWINGS AT THE ROOF AND AT TOP OF <br />ANY PARAPET WALL. USE GALVANIZED MESH -TYPE CELL CAPS. <br />PROVIDE CORNER BARS AT ALL BEAM CORNERS TO MATCH HORIZONTAL BARS. <br />9. VERTICAL BARS SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM <br />OF BAR AND AT 8'-0" O.C. MAXIMUM WITH A MINIMUM CLEARANCE OF <br />1/2" FROM MASONRY. THE CLEAR DISTANCE BETWEEN BARS SHALL NOT <br />BE LESS THAN ONE BAR DIAMETER, NOR LESS THAN 1". CENTER BARS <br />IN WALLS U.N.O. <br />10. VERTICAL REINFORCING SHALL BE AS SHOWN ON THE DRAWINGS. FILL <br />CELLS WITH COARSE GROUT AS SPECIFIED. PROVIDE ACI 90 DEGREE <br />STANDARD HOOKS INTO FOOTING AND ROOF TIE BEAM. SPLICE AP L L CE <br />VERTICAL REINFORCEMENT ABOVE FOOTING UNLESS NOTED OTHERWISE. <br />MAINTAIN VERTICAL REINFORCING SHOWN ON PLANS ABOVE AND BELOW <br />MASONRY OPENINGS EXCEEDING 10'-0" CLEAR. <br />CONTINUE FOUNDATION DOWELS BELOW ALL MASONRY OPENINGS. <br />11. ALL REINFORCED FILL CELLS ARE TO BE CLEAN AND FREE OF ANY <br />FOREIGN MATERIAL OR DEBRIS. REMOVE ANY FOREIGN MATERIAL <br />FROM FILL CELLS, INCLUDING POLYSTYRENE INSULATING INSERTS, <br />PRIOR TO GROUT POUR. <br />12, REINFORCING BARS SHALL BE STRAIGHT EXCEPT FOR BENDS AROUND <br />CORNERS AND WHERE BENDS OR HOOKS ARE DETAILED ON THE PLANS. <br />13. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, <br />IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL IN SIX <br />VERTICALS. DOWELS SHALL BE GROUTED INTO A CORE IN VERTICAL <br />ALIGNMENT, EVEN THOUGH IT IS IN AN ADJACENT CELL TO THE <br />VERTICAL WALL REINFORCEMENT. <br />14. PROVIDE CONTINUOUS HORIZONTAL WALL REINFORCING 9 GA. GALVANIZED <br />LADDER TYPE DUR-O-WALL (OR EQUIVALENT) AT 16" O.C. <br />15, PROVIDE HORIZONTAL JOINT REINFORCEMENT AT DOORS AND WINDOWS <br />FOR FIRST AND SECOND BLOCK COURSE ABOVE AND BELOW APERTURES. <br />RUN REINFORCING CONTINUOUS OR EXTEND TWO FEET FROM APERTURE <br />EDGE. <br />16. WIRE REINFORCEMENT SHALL BE LAPPED AT LEAST 6" AT SPLICES AND <br />SHALL CONTAIN AT LEAST ONE CROSS WIRE OF EACH PIECE OF <br />REINFORCEMENT IN THE LAPPED DISTANCE. <br />17. CLEANOUTS SHALL BE PROVIDED IN THE BOTTOM COURSE OF MASONRY IN <br />EACH GROUT POUR WHEN THE POUR HEIGHT EXCEEDS 5'. CLEANOUTS TO <br />BE SAW -CUT 3" X 3". <br />I& CONSOLIDATE GROUT POURS AT THE TIME OF PLACEMENT BY MECHANICAL <br />MEANS AND RECONSOLIDATE AFTER INITIAL WATER LOSS AND <br />SETTLEMENT. <br />19. SEE DRAWINGS FOR MASONRY CONTROL JOINT LOCATIONS. SPACE AT <br />26'-0" O.C. AT EXTERIOR WALLS, UNLESS NOTED OTHERWISE. <br />20. SUBMITTALS: <br />a) SUBMIT PROPOSED GROUT MIX DESIGN PRIOR TO CONSTRUCTION. <br />b) SUBMIT PROPOSED MORTAR MIX DESIGN PRIOR TO CONSTRUCTION. <br />c) SUBMIT DETAILED SHOP DRAWINGS OF REINFORCING BARS SHOWING <br />NUMBER, SIZE, AND LOCATION. INCLUDE BAR LISTS AND BEND <br />DIAGRAMS. <br />d) SUBMIT COMPRESSIVE STRENGTH TESTS OF PROPOSED MASONRY <br />UNITS PRIOR TO CONSTRUCTION. MASONRY UNITS ARE TO BE <br />TESTED IN ACCORDANCE WITH ASTM C140. <br />21. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM <br />THE FOLLOWING TESTS: <br />a) SAMPLE AND TEST GROUT IN ACCORDANCE WITH ASTM C1019 FOR <br />EACH 5000 SQ. FT. OF MASONRY. <br />b) SLUMP TESTS - ASTM C143. <br />22. PROVIDE 8" DEEP PRECAST REINFORCED CONCRETE LINTELS OVER ALL <br />MASONRY OPENINGS NOT SHOWN TO HAVE A STRUCTURAL BEAM. MINIMUM <br />END BEARING = 8". LINTEL WIDTH TO MATCH MASONRY WIDTH. <br />STRUCTURAL, STEEL <br />1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATION FOR <br />THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR <br />BUILDINGS", LATEST EDITION, EXCEPT CHAPTER 4.2.1, CODE OF <br />STANDARD PRACTICE. <br />2, WELDED CONNECTIONS SHALL CONFORM TO THE LATEST REVISED CODE OF <br />THE AMERICAN WELDING SOCIETY, AWS 01.1. ALL WELDING SHALL BE <br />PERFORMED USING E70XX, LOW HYDROGEN ELECTRODES, U.N.O. <br />ELECTRODES ARE TO BE PROTECTED FROM MOISTURE. <br />3. ALL BOLTS TO BE 3/4" DIAMETER <br />UNLESS NOTED OTHERWISE. SHOP CONNECTIONS MAY BE WELDED OR <br />BOLTED. WELDS ARE TO BE EQUAL IN STRENGTH TO BOLTS. ALL <br />FIELD CONNECTIONS ARE TO BE BOLTED WITH ASTM A325N OR A490 <br />BOLTS (BEARING TYPE BOLTS WITH THREADS IN THE SHEAR PLANE) <br />INCLUDING SUITABLE NUTS AND PLAIN HARDENED WASHERS. ALL BOLTS <br />SHALL BE TIGHTENED SNUG TIGHT UNLESS OTHERWISE NOTED. <br />4. SIZE AND USE OF HOLES: SEE AISC TABLE J3.1 U.N.O. <br />a) OVERSIZED OR LONG -SLOTTED HOLES ARE NOT PERMITTED <br />U.N.O. MAXIMUM HOLE DIAMETER = BOLT DIAMETER + 1/16". <br />b) LARGER HOLES ARE PERMITTED IN STANDARD COLUMN BASE <br />PLATES. MAXIMUM HOLE DIAMETER = BOLT DIAMETER + 3/8". <br />HARDENED WASHERS, TO COVER THE LARGER HOLE, SHALL BE <br />PROVIDED. <br />c) LARGER HOLES ARE NOT PERMITTED IN WIND FRAME COLUMN BASE <br />PLATES. MAXIMUM HOLE DIAMETER = BOLT DIAMETER + 1/16". <br />d) SLOTTED HOLES: A PLATE WASHER OR A CONTINUOUS BAR WITH <br />STANDARD HOLES, HAVING A SIZE SUFFICIENT TO COMPLETELY <br />COVER THE SLOT AFTER INSTALLATION, AND A MIN. OF 5/16" <br />THICK SHALL BE PROVIDED. TACK WELD NUT TO BOLT AFTER <br />ERECTION, <br />5, VERIFY THE EXACT SIZE AND LOCATION OF ALL FLOOR AND ROOF <br />OPENINGS FOR MECHANICAL EQUIPMENT WITH THE MECHANICAL <br />CONTRACTOR PRIOR TO FABRICATION OF MATERIALS. <br />6, SHOP PAINT - METAL ALKYD -OIL PRIMER, ANY OF THE FOLLOWING: <br />SEE ARCHITECT FOR PREFERRED COLOR. <br />MANUFACTURER DESIGNATION <br />PORTER NO. 298 <br />MOBILE NO. 13F812 <br />TINEMEC NO. 1009 <br />AMERON NO. 5102 AMERCOAT <br />SHOP PAINT ALL SURFACES OF STEEL EXCEPT ANCHOR BOLTS AND <br />SURFACES TO BE FIELD WELDED, APPLY PAINT IN ACCORDANCE WITH <br />SSPC-PA1, SHOP FIELD AND MAINTENANCE PAINTING. APPLY PAINT IN <br />SUFFICIENT VOLUME OR COATS TO PROVIDE A MINIMUM DRY FILM <br />THICKNESS OF AT LEAST 3 MILS BUT NOT MORE THAN 5 MILS. <br />7. SURFACE PREPARATION - PREPARE STEEL SURFACE IN ACCORDANCE WITH <br />SSPC-SP3 POWER TOOL CLEANING. ANY METHOD IN CONFORMANCE WITH <br />AN SSPC SPECIFICATION OF HIGHER QUALITY THAN LISTED WILL BE <br />ACCEPTABLE. AT OPTION OF CONTRACTOR, WHEELABRATOR MAY BE USED <br />FOR PREPARATION OF STEEL SURFACES, PROVIDING RESULTANT SURFACE <br />IS EQUAL IN ALL RESPECTS TO THOSE REQUIRED. <br />8. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM <br />THE FOLLOWING TESTS. <br />o) VISUALLY INSPECT ALL STEEL MEMBERS AND CONNECTIONS. <br />b) TEST 50 PERCENT OF FULL PENETRATION WELDS. <br />9. ONE COPY OF ALL TEST REPORTS SHALL BE SENT DIRECTLY TO OWNER, <br />ARCHITECT, STRUCTURAL ENGINEER, AND GENERAL CONTRACTOR. <br />10. STRUCTURAL STEEL SHAPES, TEES - ASTM A992. <br />11. STRUCTURAL STEEL ANGLES, CHANNELS, PLATES, BARS - ASTM A36. <br />12. STRUCTURAL STEEL TUBING - ASTM A500 GRADE B. <br />13. STEEL PIPE - ASTM A53 GRADE B. <br />14. ANCHOR BOLTS - F1554 GRADE 36. <br />15. NO SPLICES SHALL BE PERMITTED IN ANY STRUCTURAL STEEL MEMBER <br />UNLESS SHOWN ON APPROVED SHOP DRAWINGS. <br />16. SUBMITTALS: CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS <br />SHOWING ALL STRUCTURAL STEEL LAYOUTS AND DETAILS, SIZES OF <br />MEMBERS, TYPE OF STEEL, CONNECTION DETAILS, WELDS, BOLTS, <br />ETC., AS REQUIRED TO FABRICATE AND ERECT ALL STRUCTURAL STEEL <br />FRAMING. ALL CONNECTIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS <br />SHALL BE BY THE DETAILER AND SUBMITTED ON SHOP DRAWINGS, <br />SIGNED AND SEALED BY A REGISTERED FLORIDA ENGINEER. STEEL <br />STAIRS SHALL ALSO BE SUBMITTED ON SEALED DRAWINGS. <br />17. NON -SHRINK GROUT SHALL BE: NONMETALLIC SHRINKAGE -RESISTANT <br />GROUT, PREMIXED, NONMETALLIC, NONCORROSIVE, NONSTAINING <br />PRODUCT CONTAINING SELECTED SILICA SANDS, PORTLAND CEMENT, <br />SHRINKAGE COMPENSATING AGENTS, PLASTICIZING AND WATER -REDUCING <br />AGENTS, COMPLYING WITH CE-CRD-C621. <br />18. NO FIELD WELDING OF GALVANIZED MEMBERS IS PERMITTED. <br />19. ERECTION <br />a <br />BEFORE E THE CONTRACTOR ACTOR IS TO REMOVE ALL MUD DIRT OR OTHER FOREIGN MATTER, WHICH ACCUMULATES DURING <br />STORAGE. <br />AND HANDLING A E. <br />L <br />b) DRIFTING TO ENLARGE UNFAIR HOLES WILL NOT BE PERMITTED. <br />DRILL SUCH HOLES TO ACCOMMODATE THE NEXT LARGER SIZE <br />FASTENER, WHERE POSSIBLE. <br />c) AFTER ERECTION, CLEAN FIELD WELDS, BOLTED CONNECTIONS, <br />AND ABRADED AREAS WHERE SHOP COAT HAS BEEN DAMAGED. SPOT <br />AND PRIME AREAS USING SAME MATERIAL AS SHOP COAT. <br />d) SET ALL MEMBERS SO THAT, IN THEIR FINAL LOCATION, LEVEL, <br />PLUMBNESS AND ALIGNMENT ARE WITHIN THE TOLERANCES <br />PRESCRIBED BY AISC CODE. <br />QpENI 9M STEEL JOISTS AND JOIST GIRDERS (NOTED -JOISTS- HEWN) <br />1. STEEL JOIST MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST <br />INSTITUTE. <br />2. STEEL JOISTS SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST <br />EDITION OF THE AISC STANDARD SPECIFICATIONS FOR OPEN WEB STEEL <br />JOISTS K-SERIES. <br />3. SEE STANDARD JOIST SPECIFICATIONS FOR CAMBER REQUIREMENTS. <br />4. VERIFY THE EXACT LOCATION AND WEIGHT OF ALL MECHANICAL <br />EQUIPMENT WITH THE MECHANICAL CONTRACTOR PRIOR TO FABRICATION <br />OF JOISTS. <br />5. ALL HANGERS TO SUPPORT MECHANICAL EQUIPMENT, ETC., TO BE <br />SUPPORTED BY THE TOP OR BOTTOM CHORD OF JOISTS SHALL BE <br />LOCATED AT THE PANEL POINT OF THE JOIST. IF HANGERS MUST BE <br />LOCATED IN BETWEEN PANEL POINTS, PROVIDE JOIST STIFFENER AS <br />INDICATED IN DETAILS. ALL HANGERS TO BE LOCATED AT THE <br />CENTERLINE OF THE BOTTOM CHORD MEMBER. <br />6. PROVIDE BOTTOM CHORD CEILING EXTENSIONS WHERE REQUIRED BY <br />ARCHITECT. <br />7. JOIST MANUFACTURER SHALL DESIGN ROOF JOISTS AND BRIDGING FOR <br />THE NET WIND LOAD UPLIFT INDICATED ON THE DRAWINGS. PROVIDE <br />UPLIFT BRIDGING AT FIRST JOIST PANEL POINTS ACCORDING TO <br />S.J.I. <br />8. WHERE COLUMNS ARE NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH <br />STRUCTURAL STEEL MEMBERS, A BAR JOIST SHALL BE FIELD -BOLTED AT <br />COLUMNS TO PROVIDE LATERAL STABILITY. <br />9. JOIST BRIDGING SHALL BE FURNISHED AND INSTALLED TO MEET THE <br />DESIGN AND SPACING REQUIREMENTS OF THE SJI STANDARD <br />SPECIFICATIONS. ALL BRIDGING AND BRIDGING ANCHORS SHALL BE <br />COMPLETELY INSTALLED BEFORE CONSTRUCTION LOADS ARE PLACED ON <br />THE JOISTS. REFER TO SJI STANDARD SPECIFICATIONS FOR SPECIAL <br />BRIDGING AND ERECTION REQUIREMENTS FOR SPANS OF 40' OR MORE. <br />10. RIGID X-BRIDGING AS SHOWN ON THE PLANS SHALL BE BOLTED OR <br />WELDED AT THE INTERSECTION OF THE TWO ANGLES BETWEEN JOISTS. <br />11, JOISTS, JOIST GIRDERS, AND ACCESSORIES SHALL HAVE ONE SHOP <br />COAT OF PAINT MEETING THE MINIMUM PERFORMANCE REQUIREMENTS OF <br />THE LATEST SJI SPECIFICATIONS, SEE ARCHITECT FOR PREFERRED <br />COLOR. <br />12. SEE PLAN FOR ANY CONCENTRATED LOADS OR UNUSUAL CONDITIONS. ALL <br />JOISTS SUBJECT TO SPECIAL LOADS OR CONDITIONS SHALL BE <br />CONSIDERED "SPECIAL JOISTS". <br />13. SUBMITTALS: CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS <br />SHOWING JOISTS, BRIDGING, AND ALL CONNECTIONS. <br />14. JOIST DESIGN ENGINEER MUST BE PROVIDED WITH A COPY OF THESE <br />DRAWINGS AND SPECIFICATIONS. <br />METAL DECKING <br />1. ALL METAL DECK SHALL CONFORM TO THE REQUIREMENTS OF THE STEEL <br />DECK INSTITUTE. <br />2. METAL ROOF DECK SHALL BE 1 1/2" DEEP, 22 GA., WIDE RIB TYPE B <br />AND GALVANIZED (G60). <br />3. MINIMUM FASTENING OF ROOF DECK WITH (5) 5/8" DIA. PUDDLE WELDS <br />AT EACH SUPPORT PER 36" WIDTH AND (4) #10 TEK SCREW AT MIDSPAN <br />OF SIDELAPS. SEE PLANS FOR ADDITIONAL FASTENING. <br />4. MINIMUM FASTENING AT BUILDING PERIMETER OF DECK SHALL BE 5/8" <br />DIAMETER PUDDLE WELDS AT 6" O.C. <br />5. INSTALL ALL DECKING 3 SPAN CONTINUOUS. <br />6. DO NOT HANG OR ATTACH DUCTWORK, CONDUIT, PIPING, EQUIPMENT, <br />CEILINGS, ETC. FROM METAL DECKING. <br />7. ALL ROOF DECK OPENINGS GREATER THAN 10" DIAMETER ARE TO HAVE <br />SUPPORT ANGLES PER TYPICAL DECK OPENING DETAIL, INCLUDING <br />OPENINGS FOR ROOF SUMP PANS. <br />B. SUBMITTALS: CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS <br />SHOWING LAYOUT OF DECK, TYPE OF DECK, ALL CONNECTIONS <br />INCLUDING END WELDS, SEAM WELDS, INTERMEDIATE WELDS, AND ALL <br />ACCESSORY MATERIAL SUCH AS CLOSURES, SUMPS FOR DRAINS, ETC. <br />9. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO VISUALLY <br />INSPECT ALL DECK WELDS AND FASTENERS. <br />COLD-FORMLSM FRAMING <br />1. ALL STEEL FRAMING SHALL CONFORM TO "THE SPECIFICATION FOR THE <br />DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS", LATEST <br />EDITION, BY THE AISI. <br />2. WELDED CONNECTIONS SHALL CONFORM TO "CODE FOR WELDING IN <br />BUILDING CONSTRUCTION, 01.0" BY THE AWS. <br />3. ASTM A-568 STANDARD SPECIFICATION FOR GENERAL REQUIREMENTS <br />FOR STEEL, CARBON AND HIGH STRENGTH LOW -ALLOY HOT ROLLED SHEET <br />AND COLD ROLLED SHEET. <br />4. ALL STEEL FRAMING SHALL BE INSTALLED BY PERSONNEL EXPERIENCED <br />IN LIGHT GAUGE STEEL FRAMING INSTALLATION. <br />5. WHERE STEEL FRAMING MEMBERS ARE COMPONENTS OF ASSEMBLIES <br />INDICATED FOR A FIRE -RESISTANCE RATING, INCLUDING THOSE <br />REQUIRED FOR COMPLIANCE WITH GOVERNING REGULATIONS, PROVIDE <br />MEMBERS WHICH HAVE BEEN APPROVED BY GOVERNING AUTHORITIES <br />HAVING JURISDICTION. <br />6. PROTECT LIGHT GAUGE STEEL FRAMING MEMBERS FROM RUSTING AND <br />DAMAGE. DELIVER TO PROJECT SITE IN BUNDLES, FULLY IDENTIFIED <br />WITH NAME, BRAND, TYPE AND GRADE. STORE OFF GROUND IN A DRY <br />VENTILATED SPACE OR PROTECT WITH SUITABLE WATERPROOF <br />COVERINGS. <br />7. WITH EACH TYPE OF STEEL FRAMING REQUIRED, PROVIDE <br />MANUFACTURER'S STANDARD STEEL RUNNERS (TRACKS), BLOCKING, <br />LINTELS, CUP ANGLES, BRACING, REINFORCEMENTS, FASTENERS, AND <br />ACCESSORIES AS RECOMMENDED BY MANUFACTURER FOR APPLICATIONS <br />INDICATED, AS NEEDED TO PROVIDE A COMPLETE STEEL FRAMING <br />SYSTEM, <br />8. FABRICATE METAL FRAMING COMPONENTS OF STRUCTURAL QUALITY <br />SHEET STEEL WITH A MINIMUM YIELD POINT OF 50,000 PSI FOR <br />STUDS, AND 33,000 PSI FOR RUNNERS; ASTM A653. <br />9. SCREWS SHALL BE AS RECOMMENDED BY MANUFACTURER. <br />10. PROVIDE GALVANIZED FINISH TO METAL FRAMING COMPONENTS <br />COMPLYING WITH ASTM A525 WITH A G60 COATING. <br />11. PROVIDE MANUFACTURER'S STANDARD STRUCTURAL "C" SHAPED STEEL <br />STUDS OF SIZE, SHAPE, AND GAUGE INDICATED, WITH A NOMINAL <br />1-5/8" FLANGE AND MINIMUM 1/2" FLANGE RETURN LIP. <br />12. INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUD DEPTH. ALIGN <br />TRACKS ACCURATELY TO LAYOUT AT BASE AND TOPS OF STUDS. SECURE <br />TRACKS AS NOTED ON DRAWINGS, DO NOT EXCEED 24" O.C. SPACING <br />FOR NAIL OR POWDER -DRIVEN FASTENERS, OR 16" O.C., FOR OTHER <br />TYPES OF ATTACHMENT. PROVIDE FASTENERS AT CORNERS AND ENDS OF <br />TRACKS. <br />13. FRAME BOTH SIDES OF EXPANSION AND CONTROL JOINTS, AS SHOWN FOR <br />THE WALL SYSTEM, WITH SEPARATE STUDS AND DO NOT BRIDGE THE <br />JOINT WITH COMPONENTS OF THE STUD SYSTEM. <br />14. WHERE REQUIRED, TEMPORARY BRACING SHALL BE PROVIDED UNTIL <br />ERECTION IS COMPLETED. <br />15. RESISTANCE TO BENDING AND ROTATION ABOUT THE MINOR AXIS SHALL <br />BE PROVIDED BY MECHANICAL LATERAL BRACING WHERE REQUIRED. <br />16. ATTACHMENTS OF SIMILAR COMPONENTS SHALL BE DONE BY WELDING, <br />SCREW ATTACHMENT, OR BOLTING. WIRE TYING OF FRAMING COMPONENTS <br />SHALL NOT BE PERMITTED. <br />17. WELDING OF MEMBERS LIGHTER THAN 18 GAUGE SHALL NOT BE <br />PERMITTED. <br />I& SPLICES SHALL NOT BE PERMITTED. <br />19. MINIMUM NUMBER OF EQUALLY SPACED HORIZONTAL WALL BRIDGING FOR <br />THE HEIGHTS SHOWN: <br />UP TO 10' - 1 ROW <br />10' TO 14' - 2 ROWS <br />ABOVE 14' - AT 4' CENTERS <br />20. FOR WELDED CONNECTIONS, FUSION WELDING IS RECOMMENDED WITH A <br />DIRECT CURRENT WELDER OF 200 OR MORE AMPERE CAPACITY. USE A <br />HEAT OF 60 TO 90 AMPERES (DEPENDING ON THE GAUGE OF METAL) <br />ALONG WITH ASTM E60 ELECTRODES, <br />21. CONTRACTOR TO SUBMIT THE FOLLOWING: <br />a) SUBMIT CERTIFICATION OF MATERIALS FROM THE MANUFACTURER <br />TO SHOW COMPLIANCE WITH THESE SPECIFICATIONS AND RELATED <br />DRAWINGS. <br />22. SUBMITTED SHOP DRAWINGS MUST BE CHECKED AND SIGNED BY THE <br />GENERAL CONTRACTOR. <br />CARPENTRY <br />1. DIMENSIONED LUMBER SHALL BE DRESSED S4S, AND SHALL BEAR THE <br />GRADE STAMP OF THE MANUFACTURER'S ASSOCIATION. <br />2. ALL LUMBER SHALL BE SOUND, SEASONED, AND FREE FROM WARP. <br />3. ALL LUMBER SHALL BE SOUTHERN PINE NO. 2 GRADE OR BETTER; WITH <br />192 MAXIMUM MOISTURE CONTENT, U.N.O. ON THE PLANS. <br />4, ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED. <br />5. PRESSURE TREATED LUMBER SHALL BE IMPREGNATED WITH A CCA SALT <br />TREATMENT IN ACCORDANCE WITH F.S. TT-W-571 AND BEAR THE <br />AMERICAN WOOD PRESERVERS INSTITUTE QUALITY MARK LP-2. <br />6. PLYWOOD WALL SHEATHING SHALL BE APA RATED SHEATHING, <br />EXPOSURE 1 DURABILITY CLASSIFICATION. <br />I = <br />VERTICAL WALL REINFORCING. - <br />SEE PLAN FOR SIZE AND <br />SPACING. <br />REFER TO 6/S4.2 FOR DECK - <br />BEARING CONNECTION DETAIL. <br />STEEL ROOF JOIST. - <br />SEE PLAN. <br />1 1/2- METAL ROOF <br />DECK. SEE PLAN. <br />BRIDGING EQUALLY SPACED <br />BETWEEN SUPPORTS w/ <br />X-BRIDGING AT END BAYS. <br />SEE PLAN. <br />(3) #10 TEK SCREWS AT - <br />EACH FLANGE (6 PER STUD) <br />AT 3/4" C/C SPACING. <br />CONCRETE BEAM. <br />SEE PLAN. <br />90° STD. ACI HOOK <br />12'-0 3 8" <br />IV BQTT. CONCRETE BEAM <br />REFER TO ARCHITECT DWG's. <br />FOR TOP/WALL <br />19' 4" <br />TOP MASONRY <br />90' STD. ACI HOOK <br />K.O. BLOCK w/(1) #5 CONT., <br />GROUTED SOLID. <br />8" MASONRY WALL w/ <br />HORIZ. JOINT REINF. AT 16" O.C. <br />VARIES,&-, <br />TYP. MASONRY TIE BEAM: <br />COURSE K.O. BLOCK w/ (1) #5 <br />CONT. IN EACH COURSE. STEP <br />TIE BEAM w/ SLOPED DECK AS <br />REQUIRED. SEE 7/S4.2 <br />5/8" PLYWOOD ROOF SHEATHING. <br />FASTEN TO TRACKS AND STUDS W/ <br />#10 FLATHEAD TEK SCREWS AT 6" O.C. <br />8", 16 GA. (SOOS162-54) METAL <br />STUD FRAMING AT 24" O.C. <br />REFER TO ARCHITECT FOR <br />SLOPING ROOF CONFIGURATION. <br />CONT. 8", 18 GA. (800T125-43) <br />METAL TRACK <br />1'-4 7/8" MAX. <br />l-CONT. 8", 16 GA. (80OT200-43) <br />METAL TRACK (2" FLANGE) W/ <br />(1) 3/8" 0 X 4" TITEN HD SCREW ANCHOR <br />STOREFRONT WINDOW SYSTEM AT 24" O.C. (CENTER OF TRACK) <br />BY OTHERS. REFER TO ARCHITECT <br />DWG's. <br />SECTION <br />SCALE: 3/4" = 1'-0" <br />BUILDING DATA <br />ULTIMATE WIND SPFFD (mph): <br />(FIGURE 1609) <br />WIND LOAD FACTOR: <br />RISK CATEGORY: <br />(TABLE 1604.5) <br />ROOF ANGLE (A) <br />e Strip (Degrees) <br />WALL PRESSURE ZONES <br />(ISOMETRIC VIEW) <br />r <br />=_ <br />r--� a mom a, cagc quip <br />1200E PRESSURE ZONES <br />(PLAN MEW) <br />DESIGN WIND CRITERIA (ASD DESIGN' <br />NOT TO SCALE <br />140 INTERNAL PRESSURE COEFFICIENT: <br />(Enclosed Building per ASCE 7-10) <br />0.6 WIDTH OF EDGE STRIP (Feel.): <br />11 WIND EXPOSURE CATEGORY: <br />A<7.0 DEAD LOAD RESISTING UPLIFT (0.61) in psf): <br />DESIGN WND LOADS - COMPONENTS & CLADDING (Values per ASD) <br />+/- 0.18 <br />3.2 <br />B <br />10.0 <br />ROOF <br />WALL <br />ZONE <br />AREA (sf) <br />DESIGN PRESSURE (psf) <br />ZONE <br />AREA (sf) <br />DESIGN PRESSURE (psf) <br />Positive <br />Negative <br />I Net Uplift <br />Positive <br />Negative <br />1 <br />10.0 <br />10.00 <br />-21,15 <br />-11.15 <br />4 <br />10.0TM <br />19.36 <br />-20,98 <br />1 <br />20.0 <br />10.00 <br />-20,62 <br />-10.62 <br />4 <br />20...0 <br />18.50 <br />-20.12 <br />1 <br />50.0 <br />10.00 <br />-19.90 <br />-10.00 <br />4 <br />50.0 <br />17.37 <br />-18.98 <br />1 <br />1 100.0 <br />10.00 <br />-19.36 <br />-10.00 <br />4 <br />100.0 <br />16.51 <br />-18.13 <br />2 <br />10.0 <br />10.00 <br />-35.50 <br />-25.50 <br />5 <br />10.0 <br />19,36 <br />-25.82 <br />2 <br />20.0 <br />10.00 <br />-31.72 <br />-21.72 <br />5 <br />20.0 <br />18.50 <br />-24.10 <br />2 <br />50.0­11 <br />00 <br />-26.73 <br />-16.73 <br />_5.. <br />1 5 <br />50.0 <br />1 100.0 <br />17.37 <br />-21.83 <br />2 <br />100.0 <br />--10, <br />10.00 <br />-22.95 <br />-12.95 <br />1 16.51 <br />1 -20.12 <br />0 <br />10.00 <br />10.00 <br />- 53.43 <br />-44.25 <br />- 43.43 <br />-34.25 <br />3 <br />20,0 <br />3 <br />50.0 <br />10.00 ^ <br />--32.12 <br />-22.12 <br />3 <br />1 100.0 <br />10.00 <br />1 -22.95 <br />-12.95 <br />Notes: <br />1) For effective areas between those given above the load may be interpolated, otherwise use the load associated with the lower effective area. <br />2) Plus and minus signs signify pressures acting toward and away from the building surfaces, respectively. <br />3) See pressure zone diagrams above for corresponding zones. <br />SHEET INDEX <br />SHEET <br />NUMBER <br />SHEET TITLE <br />SOA <br />STRUCTURAL NOTES <br />S1.1 <br />FOUNDATION PLAN <br />S2.1 <br />ROOF FRAMING PLAN <br />S3.1 <br />WALL SECTIONS <br />S4.1 <br />SECTIONS AND DETAILS <br />S4.2 <br />SECTIONS AND DETAILS <br />mffmAgG <br />PROFESSIONAL ENGINEERING, INC. <br />16912 Melissa Ann Dr . Lutz, FL . 33558 <br />Ph:813.963.1906 STRUCTURAL <br />Alan C. Guenther, P.E #53308 / C.A. #26813 <br />3336 Grand Blvd. Suite 201 <br />Holiday, Florida 34690 <br />Ph. 727. 815.3336 <br />devell t <br />907 S. FT. HARRISON AVENUE <br />SUITE 102 <br />CLEARWATTR, FL 33756 <br />727-210-1900 <br />TO THE BEST OF THE KNOWLEDGE OF THE <br />ARCHITECTS AND ENGINEERS, SAID PLANS AND <br />SPECIFICATIONS COMPLY WITH THE APPLICABLE <br />MINIMUM BUILDING CODES AND THE APPLICABLE <br />MINIMUM FIRE SAFETY STANDARDS <br />`ttlltlllrrrr <br />P...'oODNS. <br />At •� <br />$ U <br />1 <br />OF <br />' rrrrrlilot /11t1� <br />C� <br />0 <br />v <br />c., <br />a� <br />a <br />0 <br />Z <br />a <br />Cl) 0 o <br />W -I <br />LL_ <br />M <br />Q _..i <br />U) T <br />�/�� <br />Z �Cr <br />�0 zIL <br />N <br />> <br />r.rj J <br />m <br />(n W <br />(D 0 <br />04.06.18 <br />date <br />17060 <br />comm. no. <br />STRUCTURAL. <br />NOTES <br />S061 <br />