Laserfiche WebLink
a <br />% <br />A. <br />I <br />f <br />SECTION 07710 - MANUFACTURED ROOF SPECIALTIES <br />PART 1 - GL91111m <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: PRODUCT DATA, SHOP DRAWINGS, AND COLOR SAMPLES. <br />B. PROVIDE PRODUCTS THAT COMPLY WITH APPLICABLE REQUIREMENTS OF SMACNA'S "ARCHITECTURAL SHEET METAL <br />MANUAL," UNLESS OTHERWISE INDICATED. <br />PART 2 - PRODUCTS <br />2.1 ROOF SPECIALTIES <br />A. ALUMINUM COPINGS: SEE DRAWINGS AND PROPOSE MANUF. FOR OWNERS REP. APPROVAL. <br />B. ALUMINUM FASCIA: SEE DRAWINGS AND PROPOSE MANUF. FOR OWNERS REP. APPROVAL. <br />C. ALUMINUM GRAVEL STOPS: SEE DRAWINGS AND PROPOSE MANUF. FOR OWNERS REP. APPROVAL. <br />D. ALUMINUM GUTTERS AND DOWNSPOUTS: SEE DRAWINGS AND PROPOSE MANUF. FOR OWNERS REP. APPROVAL. <br />E. ALUMINUM METAL SHEET: PRE FINISHED <br />PART S - EfECUTION <br />3.1 INSTALLATION <br />A. COORDINATE WITH INSTALLATION OF ROOF DECKS AND OTHER SUBSTRATES TO PRODUCE A WATERTIGHT A55EMBLY CAPABLE OF <br />WITHSTANDING INWARD AND OUTWARD LOADING PRESSURES, AND THERMAL AND LATERAL LOADS. <br />B. COAT BACK 51DE OF ALL ROOF SPECIALTIES WITH BITUMINOUS COATING WHERE THEY WILL CONTACT WOOD, FERROUS METAL, OR <br />CEMENTITIOUS CONSTRUCTION, <br />C. EXPANSION PROVISIONS: INSTALL RUNNING LENGTHS TO ALLOW CONTROLLED EXPAN51ON FOR MOVEMENT OF METAL <br />COMPONENTS, TO PREVENT WATER LEAKAGE, DEFORMATION, OR DAMAGE. <br />END OF SECTION 07710 <br />SECTION 07720 - ROOF ACCESSORIES <br />PART I - GENERAL <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: PRODUCT DATA, SHOP DRAWINGS, AND COLOR SAMPLES. <br />PART 2 - PRODUCTS <br />2.1 MATERIALS <br />A. ALUMINUM SWEET: A5TM B 20q (ASTM B 20gM), ALGLAD ALLOY 30051425, OR ALLOY AND TEMPER REQUIRED TO SUIT FORMING <br />OPERATIONS, WITH MILL FINISH, UNLESS OTHERWI5E INDICATED. <br />B. EXTRUDED ALUMINUM: ASTM B 221 (ASTM B 221M), ALLOY 6%3-T52, OR ALLOY AND TEMPER REQUIRED TO SUIT STRUCTURAL <br />AND FINISH REQUIREMENTS, WITH MILL FINISH, UNLESS OTHERWISE INDICATED. <br />C. GALVANIZED STEEL SWEET: ASTM A 653/A 653M, G90 (Z275). <br />2.2 ROOF ACCESSORIES <br />A. ROOF CURBS AND EQUIPMENT SUPPORTS: FABRICATE FROM .0747-INCH- (I.g-MM-) THICK, GALVANIZED STRUCTURAL STEEL; <br />FACTORY PRIMED AND PREPARED FOR PAINTING WITH WELDED OR SEALED MECHANICAL CORNER JOINTS. <br />I. PROVIDE UNITS WITH CANT STRIPS AND BASE PROFILE COORDINATED WITH ROOF INSULATION THICKNESS AND ROOF DECK <br />SLOPE. <br />2. PROVIDE PRESERVATIVE -TREATED WOOD NAILERS AT TOPS OF CURBS. <br />3. PROVIDE MANUFACTURER'S STANDARD RIGID OR SEMIRIGID INSULATION, <br />4. SEE DRAWINGS AND PROPOSE FOR OWNERS REP. APPROVAL. <br />B. LOW -PROFILE GRAVITY VENTILATORS: FABRICATE FROM GALVANIZED STEEL SHEET WITH HIGH-PERFORMANCE ORGANIC FINISH. <br />I. PROVIDE UNITS WITH INTEGRAL DOUBLE -WALL CURB, WITH MINIMUM I -INCH- (25-MM-) THICK, GLASS -FIBER BOARD <br />INSULATION, AND WITH MINIMUM 3-INCH (75-MM) ROOF FLANGES. <br />2. PROVIDE BIRD SCREENS FABRICATED FROM 1/2-INCH- (13-MM-) SQUARE MESH, 0.062-INCH- (1.6-MM-) DIAMETER, <br />STAINLESS -STEEL WIRE. <br />3. SEE DRAWINGS, PROPOSE FOR OWNERS REP. APPROVAL. <br />D. RIDGE VENT: HIGH -DENSITY POLYPROPYLENE, NONWOVEN MODIFIED POLYESTER, OR OTHER UV -STABILIZED PLASTIC DESIGNED <br />TO BE INSTALLED UNDER ASPHALT SHINGLES AT RIDGE, <br />PARTS - MflaITION <br />3.1 INSTALLATION <br />A. INSTALLATION: UNLESS OTHERWISE INDICATED, INSTALL ROOF ACCESSORY ITEMS ACCORDING TO CONSTRUCTION DETAILS OF <br />NRCA'S "ROOFING AND WATERPROOFING MANUAL." COORDINATE WITH INSTALLATION OF ROOF DECK, VAPOR BARRIERS, ROOF <br />INSULATION, ROOFING, AND FLASHING TO ENSURE COMBINED ELEMENTS ARE SECURE, WATERPROOF, AND WEATHERTIGHT. <br />END OF SECTION 07720 <br />SECTION 07920 - JOINT SEALANTS <br />PART I - GENERAL <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: PRODUCT DATA AND COLOR SAMPLES. <br />PART 2 - PRODUCT'S <br />2.1 JOINT SEALANTS <br />A, COMPATIBILITY: PROVIDE JOINT SEALANTS, JOINT FILLERS, AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH <br />ONE ANOTHER AND WITH JOINT SUBSTRATES UNDER SERVICE AND APPLICATION CONDITIONS. <br />B. ELASTOMERIC SEALANTS: COMPLY WITH ASTM C 920. <br />I. SINGLE -COMPONENT, NEUTRAL -CURING SILICONE SEALANT, TYPE S; GRADE NS; CLASS 25; USES T, M, AND 0, WITH <br />THE ADDITIONAL CAPABILITY TO WITHSTAND 100 PERCENT MOVEMENT IN EXTENSION AND 50 PERCENT MOVEMENT IN <br />GOMPRES51ON FOR A TOTAL OF 150 PERCENT MOVEMENT, USE FOR BUILDING EXPANSION JOINTS. <br />2. SINGLE -COMPONENT, NONSAG POLYSULFIDE SEALANT, TYPE Si GRADE N5; CLA55 12-1/21 USES NT, M, G, A, AND 0, FOR <br />GENERAL EXTERIOR USE. <br />3. SINGLE -COMPONENT, NEUTRAL -CURING SILICONE SEALANT, TYPE 5; GRADE NS; CLASS 25; USES T, NT, M, G, A, AND 0, <br />FOR GENERAL EXTERIOR USE. <br />4. SINGLE -COMPONENT, NONSAG URETHANE SEALANT, TYPE 5; GRADE NS; CLASS 25; AND USES NT, M, A, AND 0. FOR <br />GENERAL EXTERIOR USE. <br />5. SINGLE -COMPONENT, POURABLE URETHANE SEALANT, TYPE S; GRADE P; CLASS 25; USES T, M, G, A, AND 0. USE FOR <br />EXTERIOR TRAFFIC -BEARING JOINTS. <br />6. SINGLE -COMPONENT, MILDEW -RESISTANT SILICONE SEALANT, TYPE 5; GRADE NS; CLASS 25; USES NT, G, A, AND 0; <br />FORMULATED WITH FUNGICIDE. USE FOR INTERIOR SEALANT JOINTS IN CERAMIC TILE, STONE, AND OTHER HARD SURFACES <br />IN KITCHENS AND TOILET ROOM$ AND AROUND PLUMBING FIXTURES. <br />C. LATEX SEALANT: SINGLE -COMPONENT, NONSAG, MILDEW -RESISTANT, PAINTABLE, ACRYLIC -EMULSION SEALANT COMPLYING <br />WITH ASTM C 834, FOR INTERIOR USE ONLY AT PERIMETERS OF DOOR AND WINDOW FRAMES, <br />PARTS - 0121WION <br />3.1 INSTALLATION <br />A. COMPLY WITH ASTM C 11%. <br />B. COMPLY WITH ASTM C qlq FOR USE OF JOINT SEALANTS IN ACOUSTICAL APPLICATIONS. <br />END OF SECTION 07g20 <br />SECTION 08110 - STEEL DOORS AND FRAMES <br />PART I - GRA RAL <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: PRODUCT DATA AND DOOR SCHEDULE, <br />B. COMPLY WITH ANSI/5DI 100. <br />G. FIRE -RATED DOOR ASSEMBLIES: NFPA 80, TESTED PER ASTM E 152, AND LABELED AND LISTED BY UL, ITS, OR ANOTHER <br />TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. <br />PART 2 - PRODUCM <br />2.1 MATERIALS <br />A. HOT -ROLLED STEEL SHEETS: ASTM A 569/A 56CIM. <br />B. COLD -ROLLED STEEL SHEETS: A5TM A 366/A 366M OR ASTM A 620/A 620M. <br />C. GALVANIZED STEEL SHEETS: ASTM A 653/A 653M, COMMERCIAL STEEL, OR ASTM A 642/A 642M, DRAWING QUALITY, WITH A60 <br />OR G60 (ZF160 OR ZI80) COATING DESIGNATION, MILL PHOSPHATIZED. <br />2.2 STEEL DOORS AND FRAMES <br />A. PROVIDE STEEL DOORS AND FRAMES MANUFACTURED BY STEELCRAFT, CURRIES, CECO OR ARCHITECT APPROVED EQUIVALENT <br />B. STEEL DOORS: 1-3/4-INCH- (44-MM-) THICK OF MATERIALS AND ANSI/SDI 100 GRADES AND MODELS INDICATED ON DRAWINGS, <br />SCHEDULES OR IF NOT SHOWN - PROPOSE FOR OWNERS REP. APPROVAL. <br />I. INTERIOR DOORS: GRADE II, HEAVY-DUTY, MODEL 2, SEAMLESS DESIGN, MINIMUM 0.0476-INCH- (1,2-MM-) THICK, <br />COLD -ROLLED STEEL SHEET FACES, <br />2. EXTERIOR DOORS: GRADE III, EXTRA HEAVY-DUTY, MODEL 2, SEAMLESS DESIGN, MINIMUM 0.0635-INCH- (1.6-MM-) THICK, <br />GALVANIZED STEEL SHEET FACES. <br />C. DOOR SILENCERS: THREE ON STRIKE JAMBS OF SINGLE -DOOR FRAMES AND TWO ON HEADS OF DOUBLE -DOOR FRAMES. <br />D. PLASTER GUARDS: PROVIDE WHERE MORTAR MIGHT OBSTRUCT HARDWARE OPERATION AND TO CLOSE OFF INTERIOR OF OPENINGS. <br />E. FABRICATE STEEL FRAMES TO BE RIGID, NEAT IN APPEARANCE, AND FREE FROM DEFECTS, WARP, OR BUCKLE. <br />I. EXTERIOR FRAMES: FABRICATE WITH MITERED OR COPED AND CONTINUOUSLY WELDED CORNERS, FORMED FROM <br />0.0635-INCH- (1.6-MM-) THICK, GALVANIZED STEEL SHEET. <br />F. PREPARE DOORS AND FRAMES TO RECEIVE MORTISED AND CONCEALED HARDWARE ACCORDING TO SDI 107. <br />G. PRIME COAT: GALVANIZED STEEL, FS TT-P-641, TYPE II ZINC -DUST, ZINC -OXIDE PRIMER. <br />PART 5 - MaKI M <br />3.1 INSTALLATION <br />A. PLACE STEEL FRAMES TO COMPLY WITW SDI 105. <br />B. INSTALL STEEL DOORS ACCURATELY IN FRAMES, WITHIN CLEARANCES SPECIFIED IN ANSI/SDI 100. <br />1, FIRE -RATED DOORS: INSTALL WITH CLEARANCES SPECIFIED IN NFPA 80. <br />2. SMOKE -CONTROL DOORS: COMPLY WITH NFPA 105, <br />C. PRIME COAT REPAIR: IMMEDIATELY AFTER ERECTION, SAND SMOOTH ANY RUSTED OR DAMAGED AREAS OF PRIME <br />COAT AND REPAIR FINISH WITH COMPATIBLE AIR -DRYING PRIMER. <br />END OF SECTION 08110 <br />ECTION 08411 - ALUMINUM FRAMED STOREFRONTS <br />PART I - GONFRAL <br />1.1 SECTION RFQUIRFMFNTS <br />A. STRUCTURAL PERFORMANCE: PROVIDE SYSTEMS, INCLUDING ANCHORAGE, CAPABLE OF WITHSTANDING MIN. CODE COMPLIANT <br />LOADS. <br />1. MAIN -FRAMING -MEMBER DEFLECTION: LIMITED TO 1/175 OF CLEAR SPAN WITH A SAFETY FACTOR OF 1.65 <br />2. STRUCTURAL -TESTING: SYSTEMS TESTED ACCORDING TO ASTM E 330 AT 150 SAFETY FACTOR> PERCENT OF INWARD <br />AND OUTWARD WIND -LOAD DESIGN PRESSURES DO NOT EVIDENCE MATERIAL FAILURES, STRUCTURAL DISTRESS, <br />DEFLECTION FAILURES, OR PERMANENT DEFORMATION OF MAIN FRAMING MEMBERS EXCEEDING 0.2 PERCENT OF CLEAR <br />SPAN. <br />B. AIR INFILTRATION: LIMITED TO 0.06 CFM/SQ. FT. (0.3 L/S PER SQ. M) OF SYSTEM SURFACE AREA WHEN TESTED <br />ACCORDING TO ASTM E 283 AT A STATIC -AIR -PRESSURE DIFFERENCE OF THE INDUSTRY STD. <br />C. WATER PENETRATION: SYSTEMS DO NOT EVIDENCE WATER LEAKAGE WHEN TESTED ACCORDING TO ASTM E 331 AT <br />MINIMUM DIFFERENTIAL PRESSURE OF 20 PERCENT OF INWARD ACTING WIND LOAD DESIGN PRESSURE BUT NOT LESS <br />THAN THE INDUSTRY STANDARD (8 PERCENT). <br />D. AVERAGE U-VALUE: NOT MORE THAN AS INDICATED ON MECH, PLANS AND PER AAMA 1503.1. <br />E. SUBMITTALS: PRODUCT DATA, SHOP DRAWINGS, AND COLOR SAMPLES. <br />1, FOR ENTRANCE SYSTEMS, INCLUDE HARDWARE SCHEDULE AND LOCATIONS. <br />PART 2 - FIRMUC S <br />2.1 ALUMINUM -FRAMED STOREFRONTS <br />A. PROVIDE YKK YHS BO III SERIES, (IMPACT RATED) W/ 2 W X 13" FRAME COMPONENTS OR ARCHITECT APPROVED <br />EQUAL <br />B. ALUMINUM: A5TM B 20g (ASTM B 20gM) SHEET; ASTM B 221 (ASTM B 221M) EXTRUSIONS. <br />C. GLAZING: REFER TO NOTES ON DRAWINGS. <br />D. SEALANTS AND JOINT FILLERS: FOR JOINTS AT PERIMETER OF SYSTEMS AS SPECIFIED IN DIVISION 7 SECTION "JOINT <br />SEALANTS." <br />E. DOORS: YKK AP AMNUCA, W HD DOOR, MEDIUM STYLE THICK GLAZED DOORS WITH MINIMUM 0.125-INCH (3.2-MM) THICK, <br />EXTRUDED TUBULAR RAIL AND STILE MEMBERS, MECHANICALLY FASTENED CORNERS WITH REINFORCING BRACKETS THAT <br />ARE DEEP PENETRATION AND FILLET WELDED OR THAT INCORPORATE CONCEALED TIE -RODS, SNAP -ON EXTRUDED -ALUMINUM <br />GLAZING STOPS, AND PREFORMED GASKETS. <br />1, INTERIOR DOORS: PROVIDE ANSI/BHMA A156.16 SILENCERS, THREE ON STRIKE JAMB OF SINGLE -DOOR FRAMES AND <br />TWO ON HEAD OF DOUBLE -DOOR FRAMES. <br />2. EXTERIOR DOORS: PROVIDE COMPRESSION WEATHER STRIPPING AT FIXED STOPS. AT OTHER LOCATIONS, PROVIDE <br />SLIDING WEATHER STRIPPING RETAINED IN ADJUSTABLE STRIP MORTISED INTO DOOR EDGE. <br />3. HARDWARE: SEE HARDWARE SCHEDULE ON DRAWINGS. <br />F. FASTENERS AND ACCESSORIES: COMPATIBLE WITH ADJACENT MATERIALS, CORROSION -RESISTANT, NONSTAINING, AND <br />NONBLEEDING. USE CONCEALED FASTENERS EXCEPT FOR APPLICATION OF DOOR HARDWARE, <br />G. FABRICATION: FABRICATE FRAMING IN PROFILES INDICATED FOR FLUSH GLAZING (WITHOUT PROJECTING STOPS). PROVIDE <br />SUBFRAMEB AND REINFORCING OF TYPES INDICATED OR, IF NOT INDICATED, AS REQUIRED FOR A COMPLETE SYSTEM. <br />FACTORY ASSEMBLE COMPONENTS TO GREATEST EXTENT POSSIBLE. DISASSEMBLE COMPONENTS ONLY AS NECESSARY FOR <br />SHIPMENT AND INSTALLATION. <br />1. DOOR FRAMING: REINFORCE TO SUPPORT IMPOSED LOADS. FACTORY ASSEMBLE DOOR AND FRAME UNITS AND <br />FACTORY INSTALL HARDWARE TO GREATEST EXTENT POSSIBLE, REINFORCE DOOR AND FRAME UNITS FOR HARDWARE <br />INDICATED. CUT, DRILL, AND TAP FOR FACTORY -INSTALLED HARDWARE BEFORE FINISHING COMPONENTS. CLASS I <br />ANODIC FINISHES BELOW ARE HEAVIER THAN CLASS 11 FINISHES AND ARE RECOMMEND FOR EXTERIOR APPLICATIONS. <br />H. ALUMINUM FINISH: COMPLY WITH NAAMMS "METAL FINISHES MANUAL FOR ARCHITECTURAL AND METAL PRODUCTS." AS PER <br />DRAWINGS AND AS PER OWNERS REP. REQUIREMENTS. <br />1. COLOR: SEE DRAWINGS. <br />PART 8 - EX6OtTION <br />3.1 INSTALLATION <br />A. ISOLATE METAL SURFACES IN CONTACT WITH INCOMPATIBLE METAL OR CORROSIVE SUBSTRATES, INCLUDING WOOD, BY <br />PAINTING CONTACT SURFACES WITH BITUMINOUS COATING OR PRIMER, OR BY APPLYING SEALANT OR TAPE RECOMMENDED <br />BY MANUFACTURER. <br />B. INSTALL COMPONENTS TO PROVIDE A WEATHERPROOF SYSTEM. <br />C. INSTALL FRAMING COMPONENTS TRUE IN ALIGNMENT WITW ESTABLISHED LINES AND GRADES TO THE FOLLOWING <br />TOLERANCES: <br />I. VARIATION FROM PLANE: LIMIT TO 1/8 INCH IN 12 FEET (3 MM IN 3.7 M); 1/4 INCH (6 MM) OVER TOTAL LENGTH. <br />2. ALIGNMENT: FOR SURFACES ABUTTING IN LINE, LIMIT OFFSET TO 1/I6 INCH (1.5 MM). FOR SURFACES MEETING AT <br />CORNERS, LIMIT OFFSET TO 1/32 INCH (0.8 MM). <br />3, DIAGONAL MEASUREMENTS: LIMIT DIFFERENCE BETWEEN DIAGONAL MEASUREMENTS TO I/B INCH (3 MM). <br />D. INSTALL DOORS WITHOUT WARP OR RACK. ADJUST DOORS AND HARDWARE TO PROVIDE TIGHT FIT AT CONTACT POINTS AND <br />SMOOTH OPERATION. <br />END OF SECTION OB411 <br />SECTION 08710 - DOOR HARDWARE <br />PART I - GENERAL <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: HARDWARE SCHEDULE, <br />B. DELIVER KEYS TO OWNER. <br />C. FOR FIRE -RATED OPENINGS PROVIDE HARDWARE TESTED AND LISTED BY UL OR FM (NFPA 80). ON EXIT DEVICES <br />PROVIDE UL OR FM LABEL INDICATING "FIRE EXIT HARDWARE." <br />PART 2 - PRODUCTS <br />2.1 HARDWARE <br />A. HINGES: PROVIDE THE FOLLOWING: <br />1. STAINLESS -STEEL OR BRASS/BRONZE HINGES WITH STAINLESS -STEEL PINS FOR EXTERIOR. <br />2. NONREMOVABLE HINGE PINS FOR EXTERIOR AND PUBLIC INTERIOR EXPOSURE. <br />3. THREE HINGES FOR 1-3/4-INCH- (45-MM-) THICK DOORS 90 INCHES (2300 MM) OR LESS IN HEIGHT; FOUR <br />HINGES FOR DOORS MORE THAN 90 INCHES (2300 MM) IN HEIGHT. <br />B. LOCKSETS AND LATCHSETS AS FOLLOWS: <br />I. BHMA AI56.2, SERIES 4000, GRADE (A5 PER OWNERS REP.) FOR BORED LOCKS AND LATCHES. <br />2. BHMA AI56.3, GRADE 1 FOR EXIT DEVICES. <br />3. BHMA AI56.5, GRADE (AS PER OWNERS REP.) FOR AUXILLIARY LOCKS, <br />4. BHMA AI56.12, SERIES 5000, GRADE (AS PER OWNERS REP.) FOR INTERCONNECTED LOCKS AND LATCHES. <br />5. BHMA A156.13, SERIES 1000, GRADE (AS PER OWNERS REP.) FOR MORTISE LOCKS AND LATCHES. <br />6. LEVER HANDLES ON LOGKSETS AND LATCHSETS, (AS PER OWNERS REP.). <br />7. PROVIDE TRIM ON EXIT DEVICES MATCHING LOCK5ET5. <br />C. KEY LOCKS TO OWNER'S NEW MASTER -KEY SYSTEM, <br />1. CYLINDERS WITH SIX -PIN TUMBLERS AND REMOVABLE CORES. <br />2. PROVIDE CYLINDERS FOR STOREFRONT DOORS, AND OTHER LOCKING DOORS THAT DO NOT REQUIRE OTHER HARDWARE. <br />3. PROVIDE CONSTRUCTION KEYING. <br />4, PROVIDE KEY CONTROL SYSTEM, INCLUDING CABINET. <br />D. CLOSERS: PROVIDE THE FOLLOWING: <br />1. MOUNT CLOSERS ON INTERIOR SIDE (ROOM SIDE) OF DOOR OPENING. PROVIDE REGULAR -ARM, PARALLEL -ARM, OR <br />TOP -JAMB -MOUNTED CLOSERS AS NECESSARY, <br />2, ADJUSTABLE DELAYED OPENING (ACCESSIBLE TO THE DISABLED) FEATURE ON CLOSERS. <br />E. PROVIDE WALL STOPS OR FLOOR STOPS FOR DOORS WITHOUT CLOSERS, <br />F. PROVIDE HARDWARE FINISHES AS FOLLOWS: <br />1. HINGES: MATCHING FINISH OF LOCKSET/LATCH5ET. <br />2, LOCKSETS, LATCHSETS, AND EXIT DEVICES: SATIN CHROME PLATED. <br />3. CLOSERS: MATCHING FINISH OF LOCKSET/LATCHSET. <br />4. OTHER HARDWARE: MATCHING FINISH OF LOCKSET/LATCHSET. <br />PART 3 - EXECUTION <br />3.1 INSTALLATION <br />A. MOUNT HARDWARE IN LOCATIONS RECOMMENDED BY THE DOOR AND HARDWARE INSTITUTE, UNLESS OTHERWISE INDICATED. <br />3.2 HARDWARE SCHEDULE <br />A. HARDWARE - SEE PLANS. <br />END OF SECTION 08710 <br />SECTION 08800 - GLAZING <br />PART 1 - Q3NW <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: PRODUCT DATA AND 12-INCW- (300-MM-) SQUARE SAMPLES. <br />B. COMPLY WITH WRITTEN INSTRUCTIONS OF GLASS PRODUCT MANUFACTURERS; GANA'S "GLAZING MANUAL;" AND PUBLICATIONS <br />OF GANA, AAMA, AND SIGMA AS APPLICABLE TO PRODUCTS INDICATED, UNLESS MORE STRINGENT REQUIREMENTS ARE <br />INDICATED. <br />G. GLASS AND GLAZING WORK INCLUDES STOREFRONT AND ENTRANCE GLAZING (NOT INDICATED AS PRE -GLAZED, HURRICANE <br />RESISTANT GLASS, <br />1.2 SYSTEM PERFORMANCE <br />A. PROVIDE GLASS AND GLAZING THAT WILL WITHSTAND NORMAL TEMPERATURE CHANGES, WIND LOADING, IMPACT <br />LOADING, ETC, WITHOUT BREAKAGE OF GLASS, FAILURE OF SEALS AND LOSS OF AIR -TIGHTNESS AND WATER -TIGHTNESS <br />1.3 QUALITY ASSURANCE <br />A. COMPLY WITH RECOMMENDATIONS OF THE FLAT GLASS MARKETING ASSOCIATION "GLAZING MANUAL" AND "SEALANT <br />MANUAL" <br />B. COMPLY WITH INSULATED GLASS MANUFACTURER'S A55XIATION (SIGMA) #65-7-2 <br />G. HURRICANE / IMPACT RESISTANT GLAZING SYSTEM: MUST PASS DADE AND BROWARD COUNTY HURRICANE CYCLING <br />AND IMPACT TESTS AND COMPLY WITH AN51 Z97.1 AND CPSC CATEGORY II <br />D. WARRANTY: PROVIDE WRITTEN WARRANTY COVERING MANUFACTURER DEFECTS, SIGNED BY THE MANUFACTURER, FOR <br />THE PERIODS STATED BELOW AFTER SUBSTANTIAL COMPLETION <br />I. INSULATED GLA55: MANUFACTURER'S STANDARD TEN-YEAR MINIMUM PERIOD <br />2. FLOAT GLASS: MANUFACTURER'S STANDARD FIVE -TEAR MINIMUM PERIOD <br />3. LAMINATED GLASS: MANUFACTURER'S STANDARD FOUR-YEAR MINIMUM PERIOD <br />PART 2 - PRODUCM <br />2.0 MANUFACTURERS <br />A. SUBJECT TO COMPLIANCE WITH REEQUIREMENTS, PROVIDE PRODUCTS BY ZELEDYNE GLASS PRODUCTS, PPG <br />INDUSTRIES (GLA55 GROUP), GUARDIAN INDUSTRIES CORP., VIRACON INC. <br />B. HURRICANE / IMPACT RES15TANT GLASS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ARCH <br />ALUMINUM AND GLASS CO., INC, GLA551-AM, N.G.I., INSULGARD CORP., INTERPANE, SAFLEX, VIRACON, INC. <br />2.1 GLASS PRODUCTS <br />A.1/4" CLEAR TEMPERED FLOAT GLASS: GRADE B (FULLY TEMPERED), STYLE I (UNCOATED SURFACES), TYPE I, QUALITY <br />0, CLASS I <br />e. HIN4t16ANE / imACT RawANT GLAft I wl INSULATED, LAMINATED GLA►9d CON618TINT, OF " V4' TEMPERED GLASS, <br />L>'2' AIR SPACE, 2 LAYERS OF V.f HEAT 0lVR 'IWW GLASS LAMINATED T10GETHER NM A TEST COMPLIANT INTPRLAYER. <br />I. ACCEPTABLE PRODUCTS: ARCH ALUMINUM IMPACT RESISTANT GLASS, GLASSLAM N.G.I., INC.; SAFETY PLUS, INSULGARD <br />CORP.; COASTGARD, INTERPANR GLASS; SECUREPLANE, SAFLEX HURRICANE IMPACT RESISTANT GLASS, VIRACON; HRG-2. <br />2. PERFORMANCE CHARACTERISTICS: <br />a. V15113LE LIGHT TRANSMITTANCE: 65 TO 67 PERCENT <br />b. VISA13LE LIGHT REFLECTANCE: 6 TO 7 PERCENT <br />c. TOTAL SOLAR ENERGY TRANSMITTANCE: 34 TO 36 PERCENT <br />d. TOTAL SOLAR ENERGY REFLECTANCE: 5 TO 7 PERCENT <br />e. UV TRANSMITTANCE: 14 TO 16 PERCENT <br />f. SUMMER U-VALUE: 1,11 <br />g. WINTER U-VALUE: I.Oq <br />h. SOLAR HEAT GAIN COEFFICIENT: 0.51 <br />I. SHADING COEFFICIENT: 0.5g TO 0.60 <br />2.2 GLAZING GASKETS / TAPE <br />A. GLAZING GASKETS: ASTM C864, RESILIENT POLYVINYL CHLORIDE, EXTRUDED SHAPE TO FIT GLAZING CHANNEL RETAINING <br />SLOT; BLACK COLOR. <br />B. GLAZING TAPE: CLOSED CELL POLYVINYL CHLORIDE FOAM, MAXIMUM WATER ABSORPTION BY VOLUME 2 PERCENT, <br />DESIGNDED FOR 25 PERCENT COMPRESSION FOR AIR BARRIER VAPOR RETARDER SEAL, BLACKCOLOR, COILED ON RELEASE <br />PAPER OVER ADHESIVE ON TWO SIDES; WIDTHS REQUIRED FOR SPECIFIC INSTALLATION <br />C. GLAZING TAPE: BUTYL COMPOUND TAPE WITH INTEGRAL RESILIENT TUBE SPACER, 10 TO 15 SHORE A DUROMETER <br />HARDNESS, BLACK COLOR, COILED ON RELEASE PAPER, WIDTHS REQUIRED FOR SPECIFIC INSTALLATION. <br />2.3 MISCELLANEOUS GLAZING MATERIALS <br />A. COMPATIBILITY: ALL MATERIALS SHALL BE COMPATIBLE WITH SURFACES CONTACTED IN INSTALLATION <br />B, CLEANERS, PRIMERS AND SEALERS: AS RECOMMENDED BY SEALANT/GASKET MANUFACTURER. <br />C. SETTING BLOCKS: ASTM C B64 NEOPRENE, 80 TO 90 SHORE A DUROMETER HARDNESS; LENGTH 4 INCHES, WIDTH OF <br />GLAZING RABBET SPACE LESS Xa INCH, HEIGHT REQUIRED FOR GLAZING METHOD, PANE WEIGHT AND PANE AREA, <br />D. SPACERS: SHIMS: ASTM C 864: NEOPRENE, 50 TO 60 SHORE A DUROMETER HARDNESS; LENGTH 3 INCHES, ONE HALF <br />HEIGHT OF GLAZING STOP, THICKNESS REQUIRED FOR APPLICATION, ONE FACE SELF-ADHESIVE. <br />E. GLAZING SPLINES: ASTM C B64, RESILIENT POLYVINYL CHORIDE, EXTRUDED SHAPE TO FIT GLAZING CHANNEL RETAINING <br />SLOT; BLACK COLOR <br />SECTION 08800 - GLAZING ICon#.1 <br />PART S - EXECUTION <br />3,1 PREPARATION / INSTALLATION <br />A. CLEAN GLAZING / FRAMING MEMBERS IMMEDIATELY BEFORE GLAZING TO REMOVE ALL DETRIMENTAL SUBSTANCES <br />B. ADJUST GLAZING CHANNEL DIMENSIONS AS REQUIRED BY CONDITIONS FOR PROPER BITE, EDGE/FACE CLEARANCES, AND <br />SEAL THICKNESS <br />C. INSTALL PROPERLY SIZED SETTING BLOCKS IN SILL RABBET AT ONE QUARTER OF GLASS WIDTH FROM EACH CORNER, BUT NOT <br />CLOSER THAN 6 INCHES UNLESS NOTED. SET BLOCKS IN THIN COURSE OF SEALANT SUITABLE FOR HEEL BEAD USE. <br />D. PROVIDE SPACERS AND EDGE BLOCKS, CORRECTLY SIZED FOR CONDITIONS. PROVIDE A INCH MINIMUM BITE OF SPACERS ON <br />GLA55. <br />E. MITER WEDGE-SHAPED GASKETS AT CORNERS, PREVENT PULL AWAY AT CORNERS, SEAL CORNER AND BUTT JOINTS AS <br />RECOMMENDED BY GASKET MANUFACTURER. <br />F. TRIM SIGHT EXPOSED TAPE FLUSH WITH STOP AND FINISH SEALANT FLUSH WITH SIGHT LINE <br />3.2 PRTOECTION AND CLEANING <br />A. PROTECT GLASS FROM CONTAMINATING SUBSTANCES <br />B. REMOVE AND REPLACE BROKEN, CHIPPED, CRACKED, ABRADED OR DAMAGED GLA55 <br />C. REMOVE LABELS AND WASH GLASS ON BOTH FACES PRIOR TO FINAL ACCEPTANCE <br />D. REMOVE GLAZING MATERIALS FROM FINISHED SURFACES <br />END OF SECTION 08800 <br />SECTION 09220 - EXTERIOR PORTLAND CEMENT PLASTER <br />PART I- GENERAL <br />1,01 QUALITY ASSURANCE <br />A. COMPLY WITH ASTM C-g26-98A AS APPLICABLE AND "PLASTER, METAL FRAMING SYSTEM, LATH MANUAL", LATEST EDITION, <br />B. FIRE -RESISTANCE: COMPLY WITH AUTHORITIES HAVING JURISDICTION, <br />C. ALLOWABLE TOLERANCES: DO NOT EXCEED I/B INCH IN 10 FT. FOR BOW, WRAP, PLUMB OR LEVEL, <br />D. SOURCE: OBTAIN LATH AND PLASTER MATERIALS FROM A SINGLE MANUFACTURER. <br />E. LOW SUCTION AND OTHER SUBSTRATES WHERE PROPER BOND 15 QUESTIONABLE SHALL BE LATHED BEFORE PLASTERING. <br />F. REMOVE COATINGS DETRIMENTAL TO STUCCO I.E.; PAINT, GLAZE, ETC., FROM MASONRY SUBSTRATES OR INSTALL LATH <br />BEFORE PLASTERING. <br />1,02 SUBMITTALS <br />A. PROVIDE TWO 12" X 12" SAMPLES OF EACH COLOR AND FINISH TO BE APPLIED. <br />1.03 PROJECT CONDITIONS <br />A. PROTECT ADJOINING WORK FROM SOILING, SPATTERS, MOISTURE, OR OTHER DAMAGE. <br />B. PROTECT PLASTER FROM FREEZING AND FROM UNEVEN AND EXCESSIVE EVAPORATION, PROVIDE COVERINGS, MOIST CURING, <br />PROTECTION FROM WIND AND SUNLIGHT OR OTHER NECESSARY PROTECTION. <br />PART 11 - PRODUCTS <br />2.01 SUPPORT SYSTEMS <br />A. PROVIDE METAL OR WOOD SUPPORT SYSTEMS AS REQUIRED BY THE ARCHITECT OF RECORD AND OF SUFFICIENT STRENGTH <br />TO CARRY ALL ASSOCIATED LOADS, <br />B. CHANNELS: COLD ROLLED STEEL, 16-GA. MIN, THICKNESS, PROTECTED WITH RUST -INHIBITIVE PAINT OR GALVANIZED. <br />PROVIDE GALVANIZED CHANNELS FOR INSTALLATIONS IN SALT AIR ENVIRONMENTS. <br />1, CARRYING CHANNELS: MINIMUM 1-1/2" DEEP X 7/16" WIDE FLANGES. <br />2. FURRING CHANNELS: MINIMUM 3/4" DEEP X 7/16" WIDE FLANGES. <br />3. HAT CHANNELS: MINIMUM 26 GAGE. <br />C. HANGING AND TILE WIRE: AS REQUIRED BY ARCHITECT OF RECORD TO CARRY ALL ASSOCIATED LOADS. <br />D. FASTENERS: NAILS, SCREWS AND WIRE TIES AS REQUIRED BY ARCHITECT OF RECORD TO CARRY ALL A550CIATED LOADS. <br />A. ASPHALT PAPER -BACKED DIAMOND MESH METAL LATH (SMALL MESH, APPROX. 11,000 MESHES PER 50. YD.), CONFORMING TO <br />FEDERAL SPEC. UU-5-790A; TYPE I, GRADE B, STYLE 2. <br />WEIGHT: 3.4 L55. PER 5Q, YD, <br />TYPE: SELF -FURRING. <br />B. WOVEN WIRE LATH: GALVANIZED STEEL WIRE, 18 GAGE FOR I" MESH, 17 GAGE FOR 1-1/2" MESH. <br />C. WATER PROOF PAPER: U.U.15-7010, MINIMUM WEIGHT 15 LBSA00 50. FT. <br />D. FASTENERS: NAILS; GALVANIZED WITH 7/16" HEADS MINIMUM, LENGTH TO PENETRATE INTO WOOD 7/8" MINIMUM, <br />SCREWS; GALVANIZED WITH 7/16" HEADS MINIMUM, LENGTH TO PENETRATE STEEL FRAMING 1/2" MINIMUM, <br />E. ACCESSORIES: PROVIDE MINIMUM 26 GAGE, GALVANIZED METAL CORNER REINFORCEMENT, STRIP LATH, CASING BEADS (24 <br />GAGE MIN.), PREFABRICATED CONTROL JOINTS AND DRIP SCREEDS. <br />2.03 PLASTERING MATERIALS <br />A. PORTLAND CEMENT: ASTM C-150, TYPE I OR II. <br />B. HYDRATED LIME: ASTM C-206. <br />C. AGGREGATE: FOR BASE GOATS AND FINISH COATS, COMPLY WITH ASTM C-144. USE WASHED OTTAWA 511-ICA SAND FOR <br />FINISH COATS. <br />2,04 PORTLAND CEMENT PLASTER MIXES <br />A. THREE COAT WORK OVER METAL LATH, PROVIDE MECHANICALLY MIXED PROPORTIONS ACCORDING TO ASTM C-q26 AS <br />FOLD. ,%RATCH COAT: ONE PART PORTLAND CEMENT, 1/4 PART HYDRATED LIME, 3 -1/2 PARTS AGGREGATE (REINFORCING FIBERS <br />NOT TO EXCEED 3% OF PORTLAND CEMENT). <br />2. BROWN COAT: ONE PART PORTLAND CEMENT, 1/4 PART HYDRATED LIME, 4-1/2" PARTS. AGGREGATE. <br />3. FINISH GOAT: (SEE ARTICLE 2,03, Cl FOR FIELD AND ACCENT COLORS) <br />A. CLASS PB, E.I.F.S. SYSTEM, 100 % ACRYLIC RESIN BASED, FACTORY MIXED, INTEGRALLY PIGMENTED, FINISH COAT APPLIED <br />OVER E.I.F.S. MANUFACTURER'S TINTA13LE PRIMER. ACCEPTABLE MANUFACTURERS: DRYVIT, PAREX, $ENERGY AND STO. B. <br />B. SONNEBORN, SONOWALL% STUCCOTEX�, TEXTURED ACRYLIC FINISH COAT WITH FACTORY PREPARED COLOR. <br />C. ONE PART PORTLAND CEMENT, 1/2 PART HYDRATED LIME, 3-4 PARTS. AGGREGATE. <br />NOTE: FOR FACTORY PREPARED FINISH COATS, ADD WATER ONLY, PER MANUFACTURERS INSTRUCTIONS. <br />2.05 MISCELLANEOUS METALS <br />A. BONDING AGENTS: "ACRYL 60" BY STANDARD DRYWALL PRODUCTS CO. OR EQUAL. <br />B. FIBERGLASS REINFORCEMENT: ALKALINE RESISTANT 1/2" LONG STRANDS. <br />PART III - EXECUTION <br />3,01 ACCESSORY APPLICATION <br />A. CORNER BEAD: APPLY TO ALL VERTICAL AND HORIZONTAL EXTERIOR CORNERS, <br />B. CASING BEAD: INSTALL AT ALL LOCATIONS WHERE STUCCO TERMINATES AGAINST DISSIMILAR MATERIALS. <br />C. CONTROL JOINTS: BREAK BASE BEHIND JOINT AND BACK BY DOUBLE STUDS. SPACE CONTROL JOINTS NOT EXCEEDING 10 FT, <br />IN EITHER DIRECTION. WHERE VERTICAL AND HORIZONTAL JOINTS INTERSECT, BUTT HORIZONTAL JOINT TO CONTINUOUS <br />VERTICAL JOINT. CAULK SPLICES AND INTERSECTIONS, <br />D. REINFORCING: APPLY STRIPS OF METAL LATH OVER JOINTS BETWEEN DISSIMILAR PLASTER BASES, AT UN -LAPPED INTERIOR <br />CORNERS AND DIAGONALLY AROUND CORNERS OF ALL OPENINGS. <br />3.02 INSTALLATION <br />A. STUCCO APPLIED TO METAL LATH SHALL BE FULLY EMBEDDED AND COMPLETELY KEYED. <br />B, MASONRY SUBSTRATES WITH CORRECT SUCTION SHALL BE DAMPENED PRIOR TO PLASTER APPLICATION, <br />2.02 LATH 1, APPLY IN TWO COATS, BROWN COAT AND FINISH COAT, <br />2 APPLY BASE COAT IN TWO STEPS U51NG "DOUBLE -BACK" METHOD TO 1/2" THICKNESS, <br />C. PROPER CONCRETE SUBSTRATES SHALL RECEIVE BONDING AGENT PRIOR TO PLASTER APPLICATION. <br />1. APPLY IN TWO GOATS, BROWN COAT AND FIN15H COAT, <br />3,03 PLASTER THICKNESS d TEXTURE <br />A. SCRATCH COAT: ON METAL REINFORCING 1/2" THICK MINIMUM. <br />B. BROWN COAT: 3/8" THICKNESS. <br />C. FINISH COAT: APPLY 1/8" MINIMUM THICKNESS. INCREASE THICKNE55 AS REQUIRED TO ACHIEVE REQUIRED TEXTURE AND <br />AGGREGATE EMBEDMENT. <br />D. TEXTURE: "MEDIUM SAND FLOAT" <br />E. AVOID EXCESSIVE TROWEL MARKS. <br />3.04 CLEANING AND PROTECTION <br />A. REMOVE PLASTER FROM OTHER WORK NOT TO BE PLASTERED. REPAIR/REPLACE ANY SURFACE DAMAGED BY PLASTERING <br />60FAASTER MUST BE UN -DAMAGED AT TIME OF FINAL ACCEPTANCE <br />SECTION 09280 - GYPSUM BOARD ASSEMBLIES <br />PART I - GENERAL <br />1.1 SECTION REQUIREMENTS <br />A. SUBMITTALS: PRODUCT DATA. <br />B. STC-RATED ASSEMBLIES: PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO ASSEMBLIES WHOSE STC RATINGS WERE <br />DETERMINED ACCORDING TO ASTM E 90 AND CLASSIFIED ACCORDING TO ASTM E 413 BY A QUALIFIED INDEPENDENT TESTING <br />AGENCY. <br />C. FIRE -RESISTANCE -RATED ASSEMBLIES: PROVIDE MATERIALS AND CONSTRUCTION IDENTICAL TO ASSEMBLIES TESTED <br />ACCORDING TO ASTM E Ilq BY AN INDEPENDENT TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING <br />JURISDICTION. <br />PART 2 - PRODUCTS <br />2.1 METAL FRAMING AND SUPPORTS <br />A. SUSPENDED AND FURRED CEILINGS: COMPLY WITH ASTM C 645 AND ASTM C 754. <br />1. WIRE TIES: ASTM A 641 (ASTM A 641M), CLASS 1 ZINC COATING, SOFT TEMPER, 0.062 INCH (1.6 MM) THICK. <br />2, HANGERS: WIRE, ASTM A 641 (ASTM A 641M), CLASS I ZINC COATING, SOFT TEMPER, 0.162-INC14 (4.2-MM) DIAMETER. <br />3. CARRYING CHANNELS: COLD -ROLLED STEEL. <br />4. FURRING CHANNELS: COLD -ROLLED CHANNELS;STEEL STUDS, 0.0179-INC14- (0.45-MM-) THICK IN DEPTH INDICATED; STEEL <br />RIGID HAT -SHAPED CHANNELS, OR RESILIENT FURRING CHANNELS, WITH SINGLE- OR DOUBLE -LEG CONFIGURATION; SEE <br />DRAWINGS. <br />5. HOT -DIP GALVANIZED COATING COMPLYING WITH ASTM A 653, G40 (ASTM A 653M, Zg0) FOR FRAMING EXTERIOR SOFFITS <br />AND SUSPENDED CEILINGS WITHIN 10 FEET (3 M) OF EXTERIOR WALLS. <br />6. DIRECT -HUNG GRID SUSPEN51ON SYSTEM FOR INTERIOR CEILINGS. <br />B. PARTITIONS: COMPLY WITH ASTM C 645. <br />I. STUDS AND RUNNERS: AS INDICATED IN DRAWINGS. <br />2. RIGID HAT -SHAPED FURRING CHANNELS: IN DEPTH INDICATED AND 0.0179-INCH (0.45-MM) THICK, UNLESS <br />OTHERWISE INDICATED, <br />3. FURRING BRACKETS: ADJUSTABLE SERRATED -ARM TYPE FABRICATED FROM CORROSION -RESISTANT STEEL SHEET <br />0.0329-INCH (0.84-MM) THICK. <br />4. RESILIENT FURRING CHANNELS: 1/2-INCH- (12,7-MM-) DEEP, WITH SINGLE- OR DOUBLE -LEG. <br />5. Z-FURRING: Z-SHAPED MEMBERS WITH FACE FLANGE OF 1-1/4 INCH (31.8 MM), WALL -ATTACHMENT FLANGE <br />OF 7/8 INCH (22.2 MM), AND IN DEPTH REQUIRED BY INSULATION. <br />6. HOT -DIP GALVANIZED COATING COMPLYING WITH A5TM A 653, G40 (ASTM A 653M, Z90) FOR FRAMING MEMBERS ATTACHED <br />TO AND WITHIN 10 FEET (3 M) OF EXTERIOR WALLS. <br />2.2 GYPSUM BOARD <br />A. GYPSUM BOARD PRODUCTS IN MAXIMUM LENGTHS AVAILABLE TO MINIMIZE END -TO -END BUTT JOINTS. <br />I. GYPSUM WALLBOARD: A5TM C 36, IN THICKNESS INDICATED, WITH MANUFACTURER'S STANDARD EDGES. REGULAR TYPE, <br />UNLESS OTHERWISE INDICATED. <br />2. EXTERIOR GYPSUM SOFFIT BOARD: ASTM C q31, IN THICKNESS INDICATED, WITH MANUFACTURER'S STANDARD EDGES, <br />REGULAR TYPE, UNLESS OTHERWISE INDICATED. <br />3. WATER-RES15TANT GYPSUM BACKING BOARD: A5TM C 630, IN THICKNESS INDICATED. REGULAR TYPE, UNLE55 OTHERWISE <br />INDICATED, <br />2.3 ACCESSORIES <br />A. TRIM ACCESSORIES: CORNERBEAD, EDGE TRIM, AND CONTROL JOINTS COMPLYING WITH ASTM C 1047, FORMED FROM STEEL <br />SHEET ZINC COATED BY HOT -DIP PROCESS OR ROLLED ZINC OR PLASTIC. <br />B. ALUMINUM ACCESSORIES: EXTRUDED -ALUMINUM ACCESSORIES INDICATED WITH MANUFACTURER'S STANDARD <br />CORROSION -RESISTANT PRIMER. <br />C. GYPSUM BOARD JOINT TREATMENT MATERIALS: COMPLY WITH A5TM C 475. PAPER REINFORCING TAPE AND SETTING -TYPE <br />COMPOUNDS. <br />D. CEMENTITIOUS BACKER UNITS: ANSI AIIBA, <br />E. CEMENTITIOUS BACKER UNIT JOINT TREATMENT MATERIALS: COMPLY WITH ASTM C 475. <br />F. ACOUSTICAL SEALANT FOR EXPOSED AND CONCEALED JOINTS: NONSAG, PAINTABLE, NONSTAINING LATEX SEALANT COMPLYING <br />WITH ASTM C 834. <br />G. SOUND -ATTENUATION BLANKETS: UNFACED MINERAL -FIBER -BLANKET INSULATION COMPLYING WITH ASTM C 665 FOR TYPE I. <br />H. POLYSTYRENE AGGREGATE TEXTURE FINISH WHERE INDICATED. <br />I. MISCELLANEOUS MATERIALS: AUXILIARY MATERIALS FOR GYPSUM BOARD CONSTRUCTION THAT COMPLY WITH REFERENCED <br />STANDARDS, <br />PART 3 - EXECUTION <br />3.1 INSTALLATION <br />A. INSTALL STEEL FRAMING TO COMPLY WITH ASTM C 754 AND WITH ASTM C 840 REQUIREMENTS THAT APPLY <br />TO FRAMING INSTALLATION. <br />I. ISOLATE STEEL FRAMING FROM BUILDING STRUCTURE, EXCEPT AT FLOOR, TO PREVENT STRUCTURAL MOVEMENT FROM <br />TRANSFERRING LOADING TO PARTITIONS, <br />2. WHERE STUDS ARE INSTALLED DIRECTLY AGAINST EXTERIOR WALLS, INSTALL ASPHALT FELT STRIPS OR FOAM GASKETS <br />BETWEEN STUDS AND WALL. <br />B. INSTALL AND FINISH GYPSUM PANELS TO COMPLY WITH ASTM C B40 AND GA-216. <br />I. ISOLATE THE PERIMETER OF NON -LOAD -BEARING GYPSUM BOARD PARTITIONS WHERE THEY ABUT STRUCTURAL ELEMENTS, <br />EXCEPT FLOORS, BY PROVIDING A 1/4- TO 1/2-INC14- (6.4- TO 12.7-MM-) WIDE SPACE BETWEEN GYPSUM BOARD AND THE <br />STRUCTURE. TRIM EDGES WITH U-BEAD EDGE TRIM WHERE EDGES OF GYPSUM PANELS ARE EXPOSED. SEAL JOINTS <br />BETWEEN EDGES AND ABUTTING STRUCTURAL SURFACES WITH ACOUSTICAL SEALANT. <br />2. STC-RATED ASSEMBLIES: COMPLY WITH ASTM C qiq FOR LOCATION OF EDGE TRIM AND CLOSING OFF SOUND -FLANKING <br />PATHS AROUND OR THROUGH GYPSUM BOARD ASSEMBLIES. <br />3. FIRE -RESISTANCE -RATED ASSEMBLIES: COMPLY WITH REQUIREMENTS OF LISTED ASSEMBLIES. <br />4. CEMENTITIOUS BACKER UNITS: COMPLY WITH ANSI AI08.11. <br />5. SINGLE -LAYER FASTENING METHODS: FASTEN GYPSUM PANELS TO SUPPORTS WITH SCREWS. <br />6. MULTILAYER FASTENING METHODS: FASTEN PER SPECIFIED ASSEMBLY REQUIREMENTS <br />G. FINISHING GYPSUM BOARD A55EM13LIES: LEVEL 4 FINISH, UNLE55 OTHERWISE INDICATED. <br />END OF SECTION 09260 <br />SECTION 09900 - PAINTING <br />PART 1 - GENERAL <br />1.1 SECTION REQUIREMENTS <br />A, SUMMARY: PAINT ALL EXPOSED SURFACES, UNLESS OTHERWISE INDICATED. <br />I, PAINT THE BACK SIDE OF ACCESS PANELS, <br />2, COLOR CODE MECHANICAL PIPING IN ACCESSIBLE CEILING SPACES. <br />3. DO NOT PAINT PREFINISHED ITEMS, FINISHED METAL SURFACES, OPERATING PARTS, LABELS, AND MATERIALS <br />OBVIOUSLY INTENDED TO BE LEFT EXPOSED SUCH AS BRICK AND TILE. <br />4. UNLESS OTHERWISE INDICATED DO NOT PAINT CONCEALED SURFACES, <br />B. SUBMITTALS: PRODUCT DATA AND COLOR SAMPLES. <br />C. MOCKUPS: FULL -COAT FINISH SAMPLE (BENCHMARK SAMPLE) OF EACH TYPE OF COATING, SUBSTRATE, COLOR, AND FINISH <br />REQUIRED IN AREA OF NOT LESS THAN 100 SQ. FT (q 50. M). COMPLY WITH PDCA P5. <br />D. OBTAIN BLOCK FILLERS, PRIMERS, AND UNDERCOAT MATERIALS FOR EACH COATING SYSTEM FROM THE SAME MANUFACTURER <br />AS THE FINISH COATS. <br />E. EXTRA MATERIALS: DELIVER TO OWNER A I -GAL. (3.8-L) CONTAINER, PROPERLY LABELED AND SEALED, OF EACH COLOR AND <br />TYPE OF FINISH COAT PAINT USED ON PROJECT. <br />PART 2 - PRODUCTS <br />2.1 PAINT <br />A. SEE DRAWINGS <br />I. COLORS: AS SELECTED OR AS SCHEDULED. <br />B. MATERIAL QUALITY: MANUFACTURER'S BEST -QUALITY OF COATING TYPES SPECIFIED. <br />C. MATERIAL COMPATIBILITY: COMPLETE SYSTEM OF COMPATIBLE COMPONENTS THAT 15 RECOMMENDED BY MANUFACTURER FOR <br />APPLICATION INDICATED, <br />PART 3 - EXECUTION <br />3.1 APPLICATION <br />A. COMPLY WITH PAINT MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SURFACE PREPARATION, ENVIRONMENTAL AND <br />SUBSTRATE CONDITIONS, PRODUCT MIXING, AND APPLICATION. <br />3.2 EXTERIORANTERIOR PAINT APPLICATION SCHEDULE <br />A. AS SHOWN BELOW AND ON DRAWINGS, IF NOT SHOWN, TO BE SPECIFIED BY OWNERS REP, <br />B. EXTERIOR WOOD - PAINTED <br />I. IST COAT - ALKYD EXTERIOR PRIMER <br />2. 2ND COAT - LATEX EXTERIOR TRIM <br />3, 3RD COAT - LATEX EXTERIOR TRIM <br />C. EXTERIOR CONCRETE, CONCRETE BLOCK, CEMENT PLASTER (STUCCO) AND EFIS <br />L IST COAT - ACRYLIC MASONRY SEALER <br />2. 2ND COAT - LATEX EXTERIOR <br />3. BIRD COAT - LATEX EXTERIOR <br />D. EXTERIOR GYPSUM BOARD SOFFITS <br />I. IST COAT - LATEX EXTERIOR <br />2. 2ND COAT - LATEX EXTERIOR <br />E. EXTERIOR STEEL - SHOP PRIMED <br />I. TOUGH -UP PRIMER - ALKYD METAL PRIMER <br />2. 2ND COAT - ACRYLIC GLOSS ENAMEL <br />3, BIRD COAT - ACRYLIC GLOSS ENAMEL <br />F. EXTERIOR STEEL - GALVANIVED <br />I, IST COAT - ACRYLIC METAL PRIMER <br />2. 2ND COAT - ACRYLIC GLOSS ENAMEL <br />3. 3RD COAT - ACRYLIC GLOSS ENAMEL <br />G. INTERIOR WOOD - PAINTED <br />I. IST COAT - LATEX PRIMER <br />2. 2ND COAT - LATEX SEMI -GLOSS <br />3. 3RD COAT - LATEX SEMI -GLOSS <br />H. INTERIOR CONCRETE, CONCRETE BLOCK, AND CEMENT PLASTER <br />1. IST COAT - LATEX BLOCK FILLER <br />2. 2ND GOAT - LATEX 5EMI-GLOSS <br />3. 3RD COAT - LATEX SEMI -GLOSS <br />I. INTERIOR STEEL - UNPRIMED <br />I. IST COAT - ALKYD METAL PRIMER <br />2. 2ND COAT - ACRYLIC GLOSS ENAMEL <br />3. 3RD COAT - ACRYLIC GLOSS ENAMEL <br />J. INTERIOR STEEL - PRIMED <br />1. TOUCH-UP PRIMER - ALKYD METAL PRIMER <br />2. 2ND COAT - ACRYLIC GLOSS ENAMEL <br />3, BIRD COAT - ACRYLIC GLOSS ENAMEL <br />K. INTERIOR STEEL - GALVANIZED <br />1. IST COAT - ALKYD METAL PRIMER <br />2. 2ND COAT - ACRYLIC GLOSS ENAMEL <br />3, 3RD COAT - ACRYLIC GLOSS ENAMEL <br />L. INTERIOR PLASTER - NOT PAINTED UNLESS OTHERWISE NOTED. <br />M. INTERIOR WALLS - GYPSUM BOARD - NOT PAINTED EXCEPT TOILET ROOM INTERIORS. <br />N. INTERIOR FIRE RETARDANT <br />I. IST COAT - CODE COMPLIANT, FIRE RETARDANT PAINT <br />END OF SECTION 041910 <br />