■ <br />3 <br />5 <br />f <br />0 <br />C <br />u <br />I_1 <br />FACE OF FINISH SOFFIT <br />ADJUSTABLE SHELF MOUNTED <br />ON TAB AND HOLES <br />WHITE MELAMINE INTERIOR (TYP.) <br />1/4" TEMP. HARDBD. BACKING <br />CABINET DOOR WITH PLAS LAM <br />ALL SIDES - MOUNT ON SELF - <br />CLOSING CONCEALED HINGES <br />DOOR PULL - MOUNT <br />CENTERLINE 1 1/2" FROM DOOR <br />EDGE <br />UPPER CABINET HEIGHTS VARY, REFER <br />TO INT. ELEVATIONS FOR MORE INFO. <br />UPPER CABINET (TYP. <br />SCALE: 1" =1'-0" <br />Copyright© 2019. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />UNDERSIDE OF STRUCTURE ABOVE <br />CONTINUOUS FIRE CAULK (BOTH SIDES) <br />CONT. HEADER TRACK SECURED TO STRUCT. <br />@ 24" O.C. W/ 1 1/2" -10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTENER @ 24" <br />C/C MAX. <br />EXTEND PARTITION TO UNDERSIDE <br />OF STRUCTURE <br />CEILING AS SCHEDULED <br />BATT. INSULATION <br />(2) LAYER 5/8" TYPE "X" G.W.B. @ EA. <br />SIDE OF 22 GA. 3 5/8" METAL STUD <br />FRAMING & 16" O.0 - SECURE TO <br />STUDS PER UL DETAIL U419 <br />REQUIREMENTS <br />NOTE: <br />ASSEMBLY FIRE RESISTANCE <br />RATING 2 HR. -COMPLY WITH U.L. <br />DESIGN No. U419 <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" '10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. FIRE CAULK (BOTH SIDES) <br />FINISH FLOOR <br />SOLID SURFACE COUNTERTOP <br />WITH EASED EDGE & 4" <br />BACKSPLASH WITH DROP IN SINK <br />CONT. FRAMING AS REQ'D <br />PROVIDE BLOCKING AS <br />REQ'D (TYP.) <br />CONTRACTOR TO ENSURE <br />SPECIFIED SINK FITS SINK <br />CABINET PRIOR TO PURCHASE. - <br />EDGE BLOCKING BEYOND <br />AND IN FOREGROUND TO <br />SUPPORT PANEL(S) — <br />REMOVABLE PANEL; PLAS. <br />LAM. OVER 3/4" SUBSTRATE <br />BASE AS SCHEDULED -- ---- <br />SINK BASE (TYP. <br />SCALE: 1" =1'-0" <br />3" SCALE 0 3" 6" 1' <br />HEAD <br />UNDERSIDE OF STRUCTURE ABOVE <br />CONTINUOUS FIRE CAULK (BOTH SIDES) <br />CONT. HEADER TRACK SECURED TO STRUCT. <br />@ 24" O.C. W/ 1 1/2" "10 TAPCONS OR HILTI <br />DNI 32 P.S. POWER ACTIVATED FASTENER @ <br />24" C/C MAX. <br />EXTEND PARTITION TO UNDERSIDE OF <br />STRUCTURE <br />CEILING AS SCHEDULED <br />SOUND ISOLATING BATT. INSULATION <br />(1) LAYER 5/8" TYPE "X" G.W.B. @ EA. SIDE OF 22 <br />GA. 3 5/8" METAL STUD FRAMING & 16" O.0 - <br />SECURE TO STUDS PER UL DETAIL U465 <br />REQUIREMENTS <br />NOTE: <br />ASSEMBLY FIRE RESISTANCE RATING 1 <br />HR. - COMPLY WITH U.L. DESIGN No. U466 <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" -10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. FIRE CAULK (BOTH SIDES) <br />FINISH FLOOR <br />TYPE C- 1 HR RATED <br />2'-1" <br />OPEN <br />BELOW <br />CLOSE CEILING SPACE W <br />POLYTHENE MEMBRANE <br />SEAL AROUND ALL PIPE <br />& DUCT PENETRATIONS. <br />HEAD <br />UNDERSIDE OF STRUCTURE ABOVE <br />CONT. HEADER TRACK SECURED TO <br />STRUCT. @ 24" O.C. W/ 1 1/2" -10 TAPCONS <br />OR HILTI DNI 32 P.S. POWER ACTIVATED <br />FASTENER @ 24" C/C MAX. <br />EXTEND PARTITION TO UNDERSIDE OF <br />STRUCTURE <br />CEILING AS SCHEDULED <br />HEAD <br />(1) LAYER 5/8" G.W.B. ON 22 GA. 3 5/8" METAL <br />STUD FRAMING & 16" O.0 @ EA. SIDE - <br />SECURE W/ 1" TYPE 'S' SCREWS, 8" O.C. TO <br />STUDS ON JOINTS & 12" O.C. TO STUDS & <br />RUNNERS IN FIELD <br />SOUND ISOLATION BATT. INSULATION <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 112" "10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. CAULK (BOTH SIDES) <br />FINISH FLOOR <br />TYPE B <br />SECURE ALL TAPE W/ /-- <br />PLASTER TAPE ALL JOINTS, <br />RAM -TACK IN THE = <br />HIGH TACK SPRAY OR EQUAL <br />PARTITION & POLY <br />!` <br />BARRIER W/ DUCT TAPE ' <br />— 5/8" TYPE "X' GYP. BD. ON 3-5/8" <br />MTL. STUD FRAMING (1-HR.). <br />FINISH OCCUPIED SIDE W/ <br />GLOSS PAINT <br />RENOVATED SIDE <br />OCCUPIED SIDE <br />PROVIDE 20 MIN. RATED <br />DOOR IN RATED FRAME IF <br />TYPE "C" SOUND <br />ACCESS DOORS ARE <br />ISOLATING BATT <br />INSTALLED <br />INSULATION <br />CONT. 35/8" SILL TRACK <br />EXISTING FLOOR <br />SECURED TO FLOOR <br />ALTERNATE TEMPORARY 1 HR. PARTITION <br />SCALE: 3/4" =1'-0" <br />811 <br />F- <br />L4 <br />NOTE: <br />COUNTERTOP WIDTH VARY IN DEPTH. REFER <br />TO ENLARGED PLANS FOR MORE INFO. <br />1 1/2" SCALE 0 6" 1' ' <br />1111 <br />LOUVER BASE CABINET <br />SCALE: 1" =1'-0" <br />CLOSE CEILING SPACE W <br />5/8" TYPE "X" GYP. WALL <br />BD. SEAL ALL JOINTS & <br />PENETRATIONS & <br />PERIMETER W/ DUCT TAP <br />to <br />UNDERSIDE OF STRUCTURE ABOVE <br />22 GA. MTL. STUD BRACING @ 48" O.C. MAX <br />(ALTERNATE) - CONNECT EA. BRACING TO <br />DECK ABOVE W/ (4) POWER ACTUATED CONC <br />FASTENERS & TO HEAD TRACK W/ (4) 1/2" <br />SELF -TAPPING PAN HEAD SCREWS <br />CEILING AS SCHEDULED <br />CONT. HEADER TRACK SECURED @ 24" <br />O.C. <br />(1) LAYER 5/8" G.W.B. ON 22 GA. 3 5/8" METAL <br />STUD FRAMING & 16" O.C. - SECURE W/ 1" <br />TYPE 'S' SCREWS, 8" O.C. TO STUDS ON <br />JOINTS & 12" O.C. TO STUDS & RUNNERS IN <br />FIELD <br />SOUND ISOLATING BATT INSULATION <br />CONT. SILL TRACK SECURED TO STRUCTURE <br />@ 24" O.C. W/ 1 1/2" '10 TAPCONS OR HILTI DNI <br />32 P.S. POWER ACTIVATED FASTNER @ 24" <br />C/C MAX. <br />BASE AS SCHEDULED <br />CONT. CAULK <br />FINISH FLOOR <br />TYPE A <br />MTL. STUD FRAMING <br />SEAL AROUND ALL PIPE <br />& DUCT PENETRATIONS. -- PLASTER TAPE ALL JOINTS, <br />SECURE ALL TAPE W/ / HIGH TACK SPRAY OR EQUAL <br />RAM -TACK IN THE % <br />PARTITION & POLY 5/8" TYPE "X' GYP. BD. ON 3-5/8" MTL. <br />BARRIER W/ DUCT TAPE ----- STUD FRAMING (1-HR.). FINISH <br />OCCUPIED SIDE W/ GLOSS PAINT <br />RENOVATED SIDE OCCUPIED SIDE <br />PROVIDE 20 MIN. RATED <br />DOOR IN RATED FRAME IF <br />TYPE "C" SOUND <br />ACCESS DOORS ARE <br />ISOLATING BATT <br />INSTALLED <br />INSULATION <br />CONT. 35/8" SILL TRACK <br />EXISTING FLOOR <br />SECURED TO FLOOR <br />r� <br />TEMPORARY 1 HR. PARTITION <br />SCALE: 3/4" =1'-0" <br />SS COUNTERTOP <br />AND BACKSPLASH <br />DOOR PULL <br />LOUVERS <br />WHITE MELAMINE <br />INTERIOR (TYP.) <br />CABINET DOOR WITH PLAS <br />LAM ALL EXPOSED SIDES <br />3/8" SCALE " ' <br />1. ALL STUD GAUGES AND LIMITING HEIGHTS IN <br />GYPSUM WALL BOARD REFERENCE <br />SPECIFICATIONS, <br />2, ALL PARTITIONS CONTAINING PLUMBING OR <br />HAVING AN EXTERIOR FACE TO BE INSULATED. <br />3. THE FOLLOWING LIST OF ROOMS (IF USED) <br />SHALL HAVE THEIR PERIMETER PARTITIONS <br />INSULATED USING MINERAL WOOL: <br />a. ALL ROOMS ENCLOSED WITH RATED <br />PARTITIONS <br />4. ALL RATED PARTITIONS TO EXTEND FROM TOP <br />OF SLAB TO UNDERSIDE OF STRUCTURE. SEAL <br />TOP AND BOTTOM TYPICAL. <br />5. REFER TO PLANS FOR LOCATION OF PARTITION <br />TYPES. "A" IS THE TYPICAL PARTITION TYPE UNLESS <br />NOTED OTHERWISE. <br />6. UNDERSIDE OF STRUCTURE INDICATED AT HEAD <br />CONDITION FOR EACH PARTITION TYPE IS <br />DIAGRAMMATIC ONLY, AND DOES NOT INDICATE <br />EXACT CONSTRUCTION CONDITIONS. <br />7. INSTALL FRAMING AND GYPSUM WALL BOARD TO <br />OFFSET AROUND STRUCTURAL MEMBERS OR <br />OTHER OBSTRUCTIONS TO MAINTAIN FIRE <br />RESISTIVE RATINGS. <br />8. WHERE GYPSUM WALL BOARD EXTENDS TO THE <br />UNDERSIDE OF STRUCTURE, STOP GYPSUM WALL <br />BOARD'/ BELOW LINE OF STRUCTURE AND SEAL <br />AS REQUIRED. <br />9. FIRE RESISTANT, RATED PARTITIONS TO BE <br />INSTALLED WITH FIRESTOP SEALANT, UNLESS <br />NOTED OTHERWISE. <br />10. NON -RATED PARTITIONS TO BE INSTALLED WITH <br />ACOUSTICAL SEALANT, UNLESS NOTED <br />OTHERWISE. <br />11. REFER TO MECHANICAL DRAWINGS FOR <br />DETAILS ON PIPE PENETRATIONS THROUGH <br />ACOUSTICAL PARTITIONS AS WELL AS RATED <br />PARTITIONS. <br />12. INSTALL FIRE RETARDANT, TREATED BLOCKING <br />IN PARTITIONS AS REQUIRED ON DRAWINGS. <br />13. ALL PARTITIONS SCHEDULED TO RECEIVE TILE <br />OR FRP, SHALL BE CONSTRUCTED OF WATER- <br />RESISTANT CORE GYPSUM WALL BOARD. <br />14. DO NOT INSTALL GYPSUM WALL BOARD IN <br />DIRECT CONTACT WITH THE FLOOR. ALL <br />PARTITIONS SHALL BE SHIMMED '/z OFF THE FLOOR <br />WITH NON -POROUS SHIMS. PLASTIC NON -POROUS <br />HORSESHOE SHIMS ARE RECOMMENDED. GYPSUM <br />WALL BOARD SHIMS ARE NOT ACCEPTABLE. SEAL <br />WITH ACOUSTIC SEALANT AT NON -RATED WALLS. <br />SEAL WITH FIRE RATED SEALANT AT RATED WALLS. <br />SOLID SURFACE <br />COUNTERTOP AND <br />BACKSPLASH WITH EASED <br />EDGE <br />DRAWER GLIDE AND <br />DUST PANEL <br />DOOR PULL - MOUNT <br />CENTERLINE 1 1/2" FROM <br />DOOR EDGE <br />CABINET DOOR WITH PLAS <br />LAM ALL SIDES - MOUNT <br />ON CONCEALED HINGES <br />ADJUSTABLE SHELF <br />MOUNTED ON TAB AND <br />HOLES <br />WHITE MELAMINE INTERIOR <br />(TYPICAL) <br />BASE AS SCHEDULED <br />BASE CABINET -SOLID SURFACE <br />SCALE: 1" =1'-0" <br />1/4" SCALE 4' 2' 4' <br />RS&H <br />301 E• Pine Street, Suite 350 <br />Orlando, Florida 32801 <br />407-893-5800 Fax 407-264-6624 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />TLCIENGINEERING <br />SOLUTIONS <br />PROJECT TITLE: <br />AdventHealth - ZEPHYRHILLS <br />OPERATING ROOMS 8 & 9 BUILD <br />OUT <br />Advent Health <br />PROJECT ADDRESS: <br />7050 GALL BLVD, <br />ZEPHYRHILLS, FL, 33541 <br />OFF� p <br />fgE ��j w �Q <br />t- <br />NTYP' <br />9�` . <br />C) <br />0 <br />•. <br />T <br />AR 99970 <br />m <br />�NiZ <br />SrFRED A�L� z <br />m <br />n <br />ca <br />W <br />SIGNATURE W <br />IL <br />J <br />DATE W <br />IO <br />Q <br />V <br />REVISIONS z <br />w <br />DATE ISSUED: 12/11/2019 <br />REVIEWED BY: ML <br />DRAWN BY: TH <br />DESIGNED BY: MW <br />PROJECT NUMBER: <br />504-0253-000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />PARTITION & <br />MILLWORK DETAILS <br />SHEET ID: <br />BLDG. ID <br />P.A501 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />1/8" SCALE 0 4' 8f 16' <br />C <br />