Laserfiche WebLink
U <br />W <br />J <br />W <br />TRFMR. <br />`T- 3' <br />300KVA <br />0 <br />PARTIAL FLOOR PLAN <br />CENTRAL PLANT - CHILLER <br />a i /^ n_ i 1-011 <br />0 2' 4' 8' <br />NOT TO SCALE <br />TRFMR. <br />'T-3' <br />300KVA <br />�HWP-2 <br />ROOM - ELECTRICAL - DEMOLITION <br />STRIBUTION DIAGRAM <br />DIAGRAM RACEWAY KEY <br />EXISTING - TO REMAIN <br />EXISTING - SHALL BE REMOVED <br />CWP-2 <br />ELECTRICAL DEMOLITION GENERAL NOTES: <br />1. REMOVE EXISTING BRANCH CIRCUIT RACEWAY BOXES AND PORTIONS OF EXPOSED CONDUIT AT FORMER EQUIPMENT <br />CONNECTION LOCATIONS TO THE MECHANICAL EQUIPMENT TO BE REMOVED BY THE MECHANICAL CONTRACTOR. <br />2. DISCONNECTION OF MECHANICAL EQUIPMENT SHALL CONFORM TO PHASING INDICATED ON THE MECHANICAL DRAWINGS <br />AND/OR AS DIRECTED BY TAMPA BAY TRANE. <br />3. REMOVE EXISTING WIRING AND EQUIPMENT/DEVICES WHICH ARE NOT NECESSARY FOR THE FUNCTIONING OF THE NEW <br />EQUIPMENT/DEVICES AND THE FUNCTIONING OF EXISTING EQUIPMENT/DEVICES REMAINING. REMOVE ABANDONED WIRING <br />ENTIRELY UNLESS OTHERWISE NOTED. EXISTING MATERIALS AND EQUIPMENT THAT ARE REMOVED SHALL NOT BE REUSED <br />EXCEPT WHERE SPECIFICALLY NOTED. DISPOSE OF SCRAP AND DEBRIS. MAINTAIN THE ELECTRICAL CONTINUITY TO <br />EQUIPMENT/DEVICES WHICH REMAIN. THE CONTRACTOR SHALL REQUEST GUIDANCE FROM THE ENGINEER AND TAMPA <br />BAY TRANE FOR THE REQUIREMENT FOR THE REMOVAL OF ANY ADDITIONAL EQUIPMENT/DEVICES WHICH MAY NOT BE <br />INDICATED. <br />ELECTRICAL DEMOLITION NOTES: <br />O <br />EXISTING 800 AMP SQUARE D COMPANY SOLID STATE TRIP CIRCUIT BREAKER FOR EXISTING FEEDER TO TRANSFORMER <br />'T-3' 480 VOLT PRIMARY FOR FORMER 208 VOLT CHILLER 'CH-2' SHALL REMAIN IN SWITCHBOARD 'MDP-PH' FOR <br />NEW CHILLER CH-2. <br />O <br />REMOVE EXISTING HORIZONTAL PORTION OF TWO EXISTING 2-1/2 INCH CONDUITS FROM COUPLING AT END OF RADIUS <br />ABOVE SWITCHBOARD RUN ALONG CEILING TO TH EXTERIOR WALL. CONDUCTORS FROM THE <br />SWITCHBOARD 'MDP-PH', CONSISTING OF 2 PARALLEL RUNS OF 3 #250 MCM THWN CU +1 #2 CU EQUIPMENT <br />GROUND, TO TRANSFORMER 'T-3' SHALL BE REMOVED. <br />O <br />EXISTING 600 AMP 480 VOLT PRIMARY DISCONNECT FOR TRANSFORMER 'T-3' FOR FORMER 'CH-2' SHALL REMAIN <br />DEACTIVATED AND ABANDONED, <br />04 <br />EXISTING 300 KVA 480—TO-208 VOLT TRANSFORMER 'T-3' FOR FORMER 'CH-2' SHALL REMAIN DEACTIVATED AND <br />ABANDONED. <br />O <br />EXISTING, 800 AMP 208 VOLT SECONDARY DISCONNECT FOR TRANSFORMER 'T-3' FOR FORMER 'CH-2' SHALL REMAIN <br />DEACTIVATED AND ABANDONED. EXISTING CONDUCTORS FROM TRANSFORMER 'T-3', CONSISTING OF 2 PARALLEL RUNS <br />OF 3 #600 MCM THWN CU + 1 /0 CU EQUIPMENT GROUND, AND EXPOSED INTERIOR 3-1/2 INCH CONDUITS TO <br />STARTER FOR FORMER CH-2 SHALL BE REMOVED. <br />6O <br />REMOVE EXISTING FLOOR —MOUNTED STARTER FOR FORMER 'CH-2'. EXISTING WIREWAY AND CONDUCTORS TO CH-2 <br />SHALL BE REMOVED. <br />O7 <br />EXISTING CHILLED WATER PUMP 'CHWP-2' WILL BE REPLACED REMOVE EXISTING FEEDER CONSISTING OF 3 #8 + <br />GROUND IN 1 INCH CONDUIT. FROM 'MCC' TO FORMER 'CHWP-2'. <br />O8 <br />EXISTING CONDENSER WATER PUMP 'CWP-2' WILL BE REPLACED REMOVE EXISTING FEEDER CONSISTING OF 3 #8 + <br />GROUND IN 1 INCH CONDUIT. FROM 'MCC' TO FORMER 'CHWP-2'. <br />O9 <br />LOCATION OF STARTERS FOR EXISTING 'CHWP-2' AND 'CWP-2' IN MCC. <br />Tampa Bay <br />Trane <br />(* d <br />902 North Himes Ave. <br />Tampa, Florida 33609 <br />Telephone: (813) 877-8251 <br />Fax: (813) 877-8258 <br />6 <br />z <br />W <br />u <br />Lu <br />Revisions: <br />No. <br />Description <br />Date <br />1 <br />INITIAL ISSUE <br />11/11/15 <br />Z <br />OW <br />z <br />Q <br />> <br />O <br />W <br />v <br />� <br />'� <br />z <br />J <br />Q <br />M <br />w <br />W <br />J <br />Cl) aN <br />mJ <br />E = a <br />z <br />J J <br />z W <br />W <br />v J O J <br />J <br />J <br />= <br />`p a <br />C1 tLL <br />LLJ <br />N <br />z <br />Q <br />J <br />0 <br />a <br />w <br />z <br />OQ <br />O <br />0 J <br />J <br />z z <br />JaQ0 <br />to <br />LLJC�— <br />Q <br />J <br />- <br />.. <br />w <br />0 J <br />c w z <br />w <br />2 Q <br />QwJW <br />C� <br />o a(0)wa <br />cn <br />Project <br />Engineer: <br />G. <br />BARBARI <br />Project <br />Engineer: <br />S. <br />HELMER <br />Sales <br />Engineer: <br />R. <br />GERUN <br />Date: <br />11 /11 /2015 <br />Job # : CROH5298715 <br />File Name: FL HOSP CH-2 <br />Sheet # : E-2 <br />of 2 <br />