Laserfiche WebLink
6� <br />N <br />0 <br />�I <br />Ln <br />d- <br />N <br />N <br />Q <br />DEMOLITION GENERAL NOTES <br />A. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK WITH <br />26 PERSPECTIVE TRADES. BUILDING / FIRE / HEALTH OFFICIALS, AND OWNER'S <br />REPRESENTATIVE. <br />LEC./I B. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, LOAD <br />BEARING WALLS, AND STRUCTURAL ITEMS PRIOR TO STARTING WORK. <br />TO GE/ 14 24 �--------_, F--------_-1 NOTIFY AND COORDINATE WITH OWNER'S REPRESENTATIVE ALL <br />0-22 15 J 15 L _ J 15 DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION <br />UTI L TY Typ �� -_ DOCUMENTS. <br />771,4 <br />17 O 0103 O O O Y 20 Y 20 'r C. LEGALLY DISPOSE ALL REMOVED MATERIALS PER GOVERNING AUTHORITIES <br />WALK-IN Q AND AS DIRECTED BY OWNER'S REPRESENTATIVE. ALL DEBRIS SHALL BE <br />COOLER REMOVED FROM THE SITE, UNLESS PLACED IN APPROVED CONTAINERS. <br />22 <br />14L D. ALL TEMPORARY SUPPORTS, SHORING AND BRACING ETC. SHALL BE <br />DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. SUBMIT TO <br />-� OWNER'S REPRESENTATIVE FOR APPROVAL. <br />I� I <br />E. DEMOLITION EQUIPMENT THAT PRODUCES EXCESSIVE NOISE SHALL BE <br />444 I OPERATED ONLY WHEN ADJOINING BUSINESSES ARE CLOSED, OR AS <br />2 22 �C ; rl j COORDINATED WITH ALL CONCERNED PARTIES AND LOCAL MUNICIPALITY <br />o II RESTRICTION. <br />V U--- <br />-J <br />F. ALL HAZARDOUS MATERIAL REMOVAL, ASBESTOS ABATEMENT, LEAD PAINT <br />O 16 O O O ��� 20 ENCAPSULATION PROCEDURES ARE TO MEET E.P.A. AND LOCAL <br />O O �_� I REQUIREMENTS. <br />I I FOO 5ERVICE y G. REMOVE ALL FLOOR FINISHES AND PREP SUB -FLOORS TO RECEIVE NEW <br />FLOOR FINISHES AS INDICATED ON THE FLOOR FINISH PLAN. COORDINATE <br />AREAFEE <br />i RESILIENT FLOORING REMOVAL WITH ASBESTOS ASSESSMENT REPORT. <br />O O O OCD O O O O ' I H. THE GENERAL CONTRACTOR SHALL COORDINATE AND PROVIDE A WRITTEN <br />RECORD, TO THE OWNER'S REPRESENTATIVE, OF ALL SALVAGED FIXTURES, <br />; TRIMS, EQUIPMENT, CABINET, ETC. PRIOR TO DEMOLITION. ALL DECOR <br />I 1 ITEMS ARE THE RESPONSIBILITY OF THE OWNER, HOWEVER, THE GENERAL <br />3 14 7 13 I j 20 CONTRACTOR SHALL PROVIDE A SECURE AND ADEQUATE STORAGE AREA <br />Typ _- I _� FOR SUCH ITEMS. <br />o- 18 I jl j I. THE GENERAL CONTRACTOR SHALL REMOVE ALL FIXTURES AND EQUIPMENT <br />L 0-2 28 31 q I i (SHOWN DASHED). THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE <br />RECORDING OF EXISTING EQUIPMENT. LOCATIONS, CONNECTION TYPES, AND <br />Cfa a� 3 ROUGH -INS, AS WELL AS, NEW ROUGH -INS AND ALL FINAL CONNECTIONS, AS <br />15 2 I 1 ILI <br />I REQUIRED FOR ALL REUSED AND RELOCATED EQUIPMENT. <br />I� L_J <br />--1---I I A, J. THIS PLAN INDICATES ONLY THE APPROXIMATE DEMOLITION REQUIRED FOR <br />_LJ 3 j I 15 COMPLETION OF THIS REMODEL. EXISTING CONDITIONS NOT SHOWN OR <br />O O O O O O I 1 1 NOTED SHALL REMAIN UNCHANGED UNLESS APPROVED BY THE ARCHITECT <br />-H�-+--_- 32 __� OR OWNER'S REPRESENTATIVE. ALL EXISTING MATERIALS ADJACENT TO THE <br />jri NEW CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND FINISHED TO <br />-t-�-� r -1 16------- PROVIDE A SMOOTH, LEVEL, AND UNNOTICEABLE TRANSITION BETWEEN NEW <br />I I 14 1 1 L- - <br />I <br />AND EXISTING FINISHES. <br />-- ---- --- --- ----I----- iar <br />ALES AREA I I I IN K. EXISTING MATERIALS MAY BE REUSED ONLY IF SPECIFICALLY NOTED, OR, IF <br />3 I j 7 I 13 j I 11 1 PRIOR APPROVAL IS OBTAINED FROM THE OWNER'S REPRESENTATIVE. <br />i-_-_ I I I r REUSED MATERIALS SHALL, EITHER BE REAPPLIED AND / OR REFINISHED TO A <br />�----r� r LIKE NEW CONDITION IN A COST EFFECTIVE WAY, OR NEW MATERIALS SHALL <br />BE USED. <br />I I I I1 <br />I <br />OF ICE +}-I+ 1 22 L. THOROUGHLY CLEAN, PATCH AND REPAIR ALL EXISTING SURFACES TO A LIKE <br />I 1 NEW CONDITION. PROVIDE PROPER PREPARATION FOR ALL SURFACES TO <br />O I 13 Cla O O O 1 28 O j j 1 1 RECEIVE NEW FINISHES. COORDINATE FINISHES WITH CONSTRUCTION <br />I I I _____ DOCUMENTS AND / OR OWNERS REPRESENTATIVE. <br />14"I'll, 6 <br />M. SEE ARCHITECTURAL, PLUMBING, AND ELECTRICAL SHEETS FOR ADDITIONAL <br />-0 MEWS CONCRETE SLAB REMOVAL. PATCH AND REPAIR SLAB AS REQUIRED TO <br />REST OOM MATCH EXISTING. <br />Cm <br />N. REMOVE ALL UNUSED OR ABANDONED PLUMBING, MECHANICAL, AND <br />22 28 TYP ELECTRICAL ITEMS IN THEIR ENTIRETY AND PROVIDE PROPER CAP <br />L Typ.Da (� TERMINATION BELOW THE SLAB. COORDINATE WITH LOCAL BUILDING AND <br />UTILITY OFFICIALS. REPAIR ADJACENT SURFACES AS REQUIRED FOR NEW <br />16 g CONSTRUCTION.' SEE PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS <br />22 C� FOR ADDITIONAL DEMOLITION AND / OR RELOCATION INFORMATION. <br />7 O 22 O O O O O 0. THE GENERAL CONTRACTOR SHALL PROVIDE AN ASSESSMENT OF ALL <br />Typ EXISTING ROOFING TO REMAIN. ALL DAMAGED FLASHING, COPING, <br />O MEMBRANE, SHINGLES, TILES, ETC. SHALL BE REPAIRED TO PROVIDE A <br />W MEN' WATERTIGHT BUILDING ENVELOPE. UNUSED OR ABANDONED ROOFTOP <br />14 Q� ITEMS SHALL BE REMOVED AND ROOF OPENINGS SHALL BE CLOSED AND <br />v T M ROOFED WITH SIMILAR MATERIALS. ROOF DRAINS SHALL BE CLEARED AND <br />24 -� REPAIRED AS REQUIRED AND WORKING OVERFLOWS SHALL BE PROVIDED. <br />ATTENDANT 7 SEE ROOF PLAN FOR ADDITIONAL NOTES AND NEW ROOFING CONDITIONS. <br />Off ICE REA29 17 Typ <br />P. REMOVE ALL EXTRANEOUS MATERIALS FROM FLOORS, WALLS, AND CEILINGS <br />WHICH ARE NOT APPLICABLE TO THE NEW OR EXISTING CONSTRUCTION. <br />I 13 I 13 C� 4"TL <br />> /� ITEMS INCLUDE BUT ARE NOT LIMITED TO: ELECTRIC OUTLETS, CONDUITS, <br />---- --� V DUCTWORK, CEILING ANGLES, DRYWALL, FRAMING, FURRING, SOFFITS, <br />MECHANICAL ITEMS, ELECTRICAL ITEMS, PLUMBING ITEMS, HANGERS, AND <br />RELATED CONSTRUCTION DEBRIS. <br />22 Q. PREVENT PUBLIC ACCESS TO WORK AREA. INSTALL BARRIERS AND 51GNAGE <br />` CEILING DEMOLITION PLAN TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND CONTRACTORS OF <br />DANGER. <br />( 26 D-2 �I - _ �� R. CONTRACTOR SHALL SET THEIR SAW BLADES NO DEEPER THAN 3 1 /2" WHEN <br />1 ` �' q 1 SCALE: 1 /4 - I 0 <br />Typ SAW CUTTING FLOOR. <br />�h NORTH <br />CEILING DEMOLITION KEY NOTES <br />I . EXISTING CEILING GRID AND TILE TO REMAIN. REPLACE ANY DAMAGED OR DIRTY TILES WITH NEW <br />TO MATCH EXISTING. <br />2. EXISTING CEILING GRID TO REMAIN, REMOVE EXISTING TILE. REFER TO SHEET A2 FOR EXTENTS OF NEW TILE. <br />3. REMOVE CEILING AND GRID AS SHOWN (VERIFY WITH PROJECT MANAGER). REFER TO REFLECTED CEILING PLAN <br />FOR NEW WORK. REWORK HVAC AIR DEVICES AND ASSOCIATED DUCTWORK ONLY IF REQUIRED. <br />4. NOT USED <br />5. NOT USED <br />G. NOT USED <br />7. EXISTING DIFFUSERS AND RETURN GRILLES TO REMAIN. <br />8, NOT USED <br />9. EXISTING CEILING MOUNTED EXHAUST FAN TO REMAIN. <br />10. NOT USED <br />1 1. NOT USED <br />12. NOT USED <br />i0 13. IF NECESSARY, REMOVE AND RELOCATE MOTION SENSORS, DOOR CONTACTS, CAMERAS AND SECURITY SYSTE EQUIPMENT <br />VERIFY WITH PROJECT MANAGER. REFER TO SECURITY PLAN FOR NEW AND RELOCATED CAMERAS <br />AND ASSOCIATED WIRING. <br />4 14. EXISTING LIGHT FIXTURE TO REMAIN. <br />15. REMOVE EXISTING LIGHT FIXTURE AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER <br />CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF <br />SALVAGED FIXTURES. <br />I G. EXISTING EXIT LIGHT/ EMERGENCY UNIT TO REMAIN. <br />17. REMOVE EXIT LIGHT/EMERGENCY UNIT AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER <br />CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF <br />SALVAGED FIXTURES, <br />LEGEND <br />16. EXISTING CEILING RECEPTACLES TO REMAIN. O <br />19. NOT USED <br />20. REMOVE EXISTING EVAPORATOR, DISCONNECT POWER AND REFRIGERANT PIPING. <br />2 1. REMOVE EXISTING EVAPORATOR FOR RELOCATION, DISCONNECT POWER AND REFRIGERANT PIPING. REFER TO MECHANICAL <br />SHEETS.------- <br />22. EXISTING CAMERAS TO REMAIN. <br />23, NOT USED <br />24. NO WORK IN THI5 AREA, UNLESS NOTED OTHERWISE. <br />O <br />25. NOT USED <br />2G. EXISTING EXTERIOR SOFFIT, LIGHTING AND COMPONENT TO REMAIN. <br />27. EXISTING CEILING MOUNTED EVAPORATORTO REMAIN, 3 O <br />28. EXISTING SPEAKERS TO REMAIN. <br />29. EXISTING CEILING MOUNTED AIR -CURTAIN TO BE REMOVED. <br />30, NOT USED O <br />3 1. EXISTING WI-FI CONNECTION TO REMAIN. <br />32. REMOVE EXISTING POWER POLE AND ALL ASSOCIATED WIRING BACK TO PANEL. I (x) <br />SEE DEMOLITION KEY NOTES <br />EXISTING CEILING GRID, LIGHTS, AND EQUIPMENT, <br />ETC. TO REMAIN. <br />EXISTING CEILING GRID, LIGHTS; AND EQUIPMENT, <br />BULKHEAD, WALL, ETC. TO BE REMOVED AND / OR <br />RELOCATED <br />4' -TWO - LAMP PLUORE5CENT <br />LOW -PROFILE WRAP AROUND FIXTURE. <br />RECESSED LIGHTING. <br />RECESSED LIGHTING. <br />COMBINATION EXIT SIGN AND DUALITE <br />EMERGENCY LAMPS. <br />EMERGENCY LIGHTING UNIT W/ 2 HEADS. <br />DUALITE OUTDOOR LXT05 WITH <br />MINIMUM OF 90 MINUTE BACK-UP <br />BATTERY. INSTALL ONLY WHEN <br />REQUIRED BY CODE. <br />00 <br />zul) <br />o_l . <br />F- o <br />W <br />J c <br />f �o <br />0 <br />O m <br />U "' <br />O in <br />Q Y m <br />C <br />Lu } t <br />a <br />U L • <br />m <br />5TIPLENVO FOR REUSE <br />THIS DRAWING WA5 SPECIFICALLY <br />PREPARED FOR USE IN REGARDS TO THE <br />PERMITTING AND CONSTRUCTION OF THIS <br />PROJECT AND IS NOT SUITABLE FOR USE <br />FOR ANY OTHER PROJECT. USE OF THI5 <br />DRAWING FOR REFERENCE OR EXAMPLE <br />ON ANOTHER PROJECT REQUIRES THE <br />5ERVICE5 OF PROPERLY LICENSED <br />ARCHITECTS AND ENGINEERS. <br />REPRODUCTION OF THIS DRAWING FOR <br />REUSE ON ANOTHER PROJECT 15 NOT <br />AUTHORIZED AND MAY 5E CONTRARY TO <br />THE LAW. <br />w <br />u1 <br />N <br />N <br />N t6 <br />r <br />N N <br />iw <br />N <br />0 <br />N <br />@ U <br />�-a <br />co <br />oN <br />O <br />J <br />J <br />J <br />L <br />zZZ <br />0 <br />0 <br />0 <br />�o <br />Ln <br />cn <br />Lo <br />3 <br />a <br />Lu <br />a/ <br />al <br />�'� <br />w <br />w <br />L.3 <br />O <br />O <br />O <br />t L <br />Lu <br />COOLER/ FREEZER LIGHTING ® OLO z <br />i Q <br />O SPEAKERLL- <br />3 <br />0o CEILING MOUNTED RECEPTACLE -� <br /><_On SECURITY CAMERA _ U <br />DATE ry <br />C"-y 0- <br />z <br />OR SUPPLY DIFF,9bbk _ <br />J� N CD <br />Il_I <br />OR z z RETURN AIR GRILLE/ EXHAUST GRILLE. LDG NO, G858 <br />VERSION OR <br />PROJECTID 751 193-01 <br />u , SCALE O 4' <br />CITY OF ZE Tly �3 .1 /4" = 11-01, <br />CEILING SYSTEM LS �, 3), "A Nlr 1 <br />14 TEAM DATE <br />DGN R. <br />CE50 OG.242015 <br />RVWP.r ; JAD <br />bKWG. NO. <br />G858- D-2 <br />(n U I I I I --- - I I <br />