6�
<br />N
<br />0
<br />�I
<br />Ln
<br />d-
<br />N
<br />N
<br />Q
<br />DEMOLITION GENERAL NOTES
<br />A. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK WITH
<br />26 PERSPECTIVE TRADES. BUILDING / FIRE / HEALTH OFFICIALS, AND OWNER'S
<br />REPRESENTATIVE.
<br />LEC./I B. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, LOAD
<br />BEARING WALLS, AND STRUCTURAL ITEMS PRIOR TO STARTING WORK.
<br />TO GE/ 14 24 �--------_, F--------_-1 NOTIFY AND COORDINATE WITH OWNER'S REPRESENTATIVE ALL
<br />0-22 15 J 15 L _ J 15 DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONSTRUCTION
<br />UTI L TY Typ �� -_ DOCUMENTS.
<br />771,4
<br />17 O 0103 O O O Y 20 Y 20 'r C. LEGALLY DISPOSE ALL REMOVED MATERIALS PER GOVERNING AUTHORITIES
<br />WALK-IN Q AND AS DIRECTED BY OWNER'S REPRESENTATIVE. ALL DEBRIS SHALL BE
<br />COOLER REMOVED FROM THE SITE, UNLESS PLACED IN APPROVED CONTAINERS.
<br />22
<br />14L D. ALL TEMPORARY SUPPORTS, SHORING AND BRACING ETC. SHALL BE
<br />DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. SUBMIT TO
<br />-� OWNER'S REPRESENTATIVE FOR APPROVAL.
<br />I� I
<br />E. DEMOLITION EQUIPMENT THAT PRODUCES EXCESSIVE NOISE SHALL BE
<br />444 I OPERATED ONLY WHEN ADJOINING BUSINESSES ARE CLOSED, OR AS
<br />2 22 �C ; rl j COORDINATED WITH ALL CONCERNED PARTIES AND LOCAL MUNICIPALITY
<br />o II RESTRICTION.
<br />V U---
<br />-J
<br />F. ALL HAZARDOUS MATERIAL REMOVAL, ASBESTOS ABATEMENT, LEAD PAINT
<br />O 16 O O O ��� 20 ENCAPSULATION PROCEDURES ARE TO MEET E.P.A. AND LOCAL
<br />O O �_� I REQUIREMENTS.
<br />I I FOO 5ERVICE y G. REMOVE ALL FLOOR FINISHES AND PREP SUB -FLOORS TO RECEIVE NEW
<br />FLOOR FINISHES AS INDICATED ON THE FLOOR FINISH PLAN. COORDINATE
<br />AREAFEE
<br />i RESILIENT FLOORING REMOVAL WITH ASBESTOS ASSESSMENT REPORT.
<br />O O O OCD O O O O ' I H. THE GENERAL CONTRACTOR SHALL COORDINATE AND PROVIDE A WRITTEN
<br />RECORD, TO THE OWNER'S REPRESENTATIVE, OF ALL SALVAGED FIXTURES,
<br />; TRIMS, EQUIPMENT, CABINET, ETC. PRIOR TO DEMOLITION. ALL DECOR
<br />I 1 ITEMS ARE THE RESPONSIBILITY OF THE OWNER, HOWEVER, THE GENERAL
<br />3 14 7 13 I j 20 CONTRACTOR SHALL PROVIDE A SECURE AND ADEQUATE STORAGE AREA
<br />Typ _- I _� FOR SUCH ITEMS.
<br />o- 18 I jl j I. THE GENERAL CONTRACTOR SHALL REMOVE ALL FIXTURES AND EQUIPMENT
<br />L 0-2 28 31 q I i (SHOWN DASHED). THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE
<br />RECORDING OF EXISTING EQUIPMENT. LOCATIONS, CONNECTION TYPES, AND
<br />Cfa a� 3 ROUGH -INS, AS WELL AS, NEW ROUGH -INS AND ALL FINAL CONNECTIONS, AS
<br />15 2 I 1 ILI
<br />I REQUIRED FOR ALL REUSED AND RELOCATED EQUIPMENT.
<br />I� L_J
<br />--1---I I A, J. THIS PLAN INDICATES ONLY THE APPROXIMATE DEMOLITION REQUIRED FOR
<br />_LJ 3 j I 15 COMPLETION OF THIS REMODEL. EXISTING CONDITIONS NOT SHOWN OR
<br />O O O O O O I 1 1 NOTED SHALL REMAIN UNCHANGED UNLESS APPROVED BY THE ARCHITECT
<br />-H�-+--_- 32 __� OR OWNER'S REPRESENTATIVE. ALL EXISTING MATERIALS ADJACENT TO THE
<br />jri NEW CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND FINISHED TO
<br />-t-�-� r -1 16------- PROVIDE A SMOOTH, LEVEL, AND UNNOTICEABLE TRANSITION BETWEEN NEW
<br />I I 14 1 1 L- -
<br />I
<br />AND EXISTING FINISHES.
<br />-- ---- --- --- ----I----- iar
<br />ALES AREA I I I IN K. EXISTING MATERIALS MAY BE REUSED ONLY IF SPECIFICALLY NOTED, OR, IF
<br />3 I j 7 I 13 j I 11 1 PRIOR APPROVAL IS OBTAINED FROM THE OWNER'S REPRESENTATIVE.
<br />i-_-_ I I I r REUSED MATERIALS SHALL, EITHER BE REAPPLIED AND / OR REFINISHED TO A
<br />�----r� r LIKE NEW CONDITION IN A COST EFFECTIVE WAY, OR NEW MATERIALS SHALL
<br />BE USED.
<br />I I I I1
<br />I
<br />OF ICE +}-I+ 1 22 L. THOROUGHLY CLEAN, PATCH AND REPAIR ALL EXISTING SURFACES TO A LIKE
<br />I 1 NEW CONDITION. PROVIDE PROPER PREPARATION FOR ALL SURFACES TO
<br />O I 13 Cla O O O 1 28 O j j 1 1 RECEIVE NEW FINISHES. COORDINATE FINISHES WITH CONSTRUCTION
<br />I I I _____ DOCUMENTS AND / OR OWNERS REPRESENTATIVE.
<br />14"I'll, 6
<br />M. SEE ARCHITECTURAL, PLUMBING, AND ELECTRICAL SHEETS FOR ADDITIONAL
<br />-0 MEWS CONCRETE SLAB REMOVAL. PATCH AND REPAIR SLAB AS REQUIRED TO
<br />REST OOM MATCH EXISTING.
<br />Cm
<br />N. REMOVE ALL UNUSED OR ABANDONED PLUMBING, MECHANICAL, AND
<br />22 28 TYP ELECTRICAL ITEMS IN THEIR ENTIRETY AND PROVIDE PROPER CAP
<br />L Typ.Da (� TERMINATION BELOW THE SLAB. COORDINATE WITH LOCAL BUILDING AND
<br />UTILITY OFFICIALS. REPAIR ADJACENT SURFACES AS REQUIRED FOR NEW
<br />16 g CONSTRUCTION.' SEE PLUMBING, MECHANICAL, AND ELECTRICAL SHEETS
<br />22 C� FOR ADDITIONAL DEMOLITION AND / OR RELOCATION INFORMATION.
<br />7 O 22 O O O O O 0. THE GENERAL CONTRACTOR SHALL PROVIDE AN ASSESSMENT OF ALL
<br />Typ EXISTING ROOFING TO REMAIN. ALL DAMAGED FLASHING, COPING,
<br />O MEMBRANE, SHINGLES, TILES, ETC. SHALL BE REPAIRED TO PROVIDE A
<br />W MEN' WATERTIGHT BUILDING ENVELOPE. UNUSED OR ABANDONED ROOFTOP
<br />14 Q� ITEMS SHALL BE REMOVED AND ROOF OPENINGS SHALL BE CLOSED AND
<br />v T M ROOFED WITH SIMILAR MATERIALS. ROOF DRAINS SHALL BE CLEARED AND
<br />24 -� REPAIRED AS REQUIRED AND WORKING OVERFLOWS SHALL BE PROVIDED.
<br />ATTENDANT 7 SEE ROOF PLAN FOR ADDITIONAL NOTES AND NEW ROOFING CONDITIONS.
<br />Off ICE REA29 17 Typ
<br />P. REMOVE ALL EXTRANEOUS MATERIALS FROM FLOORS, WALLS, AND CEILINGS
<br />WHICH ARE NOT APPLICABLE TO THE NEW OR EXISTING CONSTRUCTION.
<br />I 13 I 13 C� 4"TL
<br />> /� ITEMS INCLUDE BUT ARE NOT LIMITED TO: ELECTRIC OUTLETS, CONDUITS,
<br />---- --� V DUCTWORK, CEILING ANGLES, DRYWALL, FRAMING, FURRING, SOFFITS,
<br />MECHANICAL ITEMS, ELECTRICAL ITEMS, PLUMBING ITEMS, HANGERS, AND
<br />RELATED CONSTRUCTION DEBRIS.
<br />22 Q. PREVENT PUBLIC ACCESS TO WORK AREA. INSTALL BARRIERS AND 51GNAGE
<br />` CEILING DEMOLITION PLAN TO ALERT THE GENERAL PUBLIC, EMPLOYEES, AND CONTRACTORS OF
<br />DANGER.
<br />( 26 D-2 �I - _ �� R. CONTRACTOR SHALL SET THEIR SAW BLADES NO DEEPER THAN 3 1 /2" WHEN
<br />1 ` �' q 1 SCALE: 1 /4 - I 0
<br />Typ SAW CUTTING FLOOR.
<br />�h NORTH
<br />CEILING DEMOLITION KEY NOTES
<br />I . EXISTING CEILING GRID AND TILE TO REMAIN. REPLACE ANY DAMAGED OR DIRTY TILES WITH NEW
<br />TO MATCH EXISTING.
<br />2. EXISTING CEILING GRID TO REMAIN, REMOVE EXISTING TILE. REFER TO SHEET A2 FOR EXTENTS OF NEW TILE.
<br />3. REMOVE CEILING AND GRID AS SHOWN (VERIFY WITH PROJECT MANAGER). REFER TO REFLECTED CEILING PLAN
<br />FOR NEW WORK. REWORK HVAC AIR DEVICES AND ASSOCIATED DUCTWORK ONLY IF REQUIRED.
<br />4. NOT USED
<br />5. NOT USED
<br />G. NOT USED
<br />7. EXISTING DIFFUSERS AND RETURN GRILLES TO REMAIN.
<br />8, NOT USED
<br />9. EXISTING CEILING MOUNTED EXHAUST FAN TO REMAIN.
<br />10. NOT USED
<br />1 1. NOT USED
<br />12. NOT USED
<br />i0 13. IF NECESSARY, REMOVE AND RELOCATE MOTION SENSORS, DOOR CONTACTS, CAMERAS AND SECURITY SYSTE EQUIPMENT
<br />VERIFY WITH PROJECT MANAGER. REFER TO SECURITY PLAN FOR NEW AND RELOCATED CAMERAS
<br />AND ASSOCIATED WIRING.
<br />4 14. EXISTING LIGHT FIXTURE TO REMAIN.
<br />15. REMOVE EXISTING LIGHT FIXTURE AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER
<br />CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF
<br />SALVAGED FIXTURES.
<br />I G. EXISTING EXIT LIGHT/ EMERGENCY UNIT TO REMAIN.
<br />17. REMOVE EXIT LIGHT/EMERGENCY UNIT AND PULL WIRE AND CONDUIT BACK TO NEXT REMAINING DEVICE. MAINTAIN POWER
<br />CONNECTION TO REMAINING DEVICES IN CIRCUIT. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK OR REUSE OF
<br />SALVAGED FIXTURES,
<br />LEGEND
<br />16. EXISTING CEILING RECEPTACLES TO REMAIN. O
<br />19. NOT USED
<br />20. REMOVE EXISTING EVAPORATOR, DISCONNECT POWER AND REFRIGERANT PIPING.
<br />2 1. REMOVE EXISTING EVAPORATOR FOR RELOCATION, DISCONNECT POWER AND REFRIGERANT PIPING. REFER TO MECHANICAL
<br />SHEETS.-------
<br />22. EXISTING CAMERAS TO REMAIN.
<br />23, NOT USED
<br />24. NO WORK IN THI5 AREA, UNLESS NOTED OTHERWISE.
<br />O
<br />25. NOT USED
<br />2G. EXISTING EXTERIOR SOFFIT, LIGHTING AND COMPONENT TO REMAIN.
<br />27. EXISTING CEILING MOUNTED EVAPORATORTO REMAIN, 3 O
<br />28. EXISTING SPEAKERS TO REMAIN.
<br />29. EXISTING CEILING MOUNTED AIR -CURTAIN TO BE REMOVED.
<br />30, NOT USED O
<br />3 1. EXISTING WI-FI CONNECTION TO REMAIN.
<br />32. REMOVE EXISTING POWER POLE AND ALL ASSOCIATED WIRING BACK TO PANEL. I (x)
<br />SEE DEMOLITION KEY NOTES
<br />EXISTING CEILING GRID, LIGHTS, AND EQUIPMENT,
<br />ETC. TO REMAIN.
<br />EXISTING CEILING GRID, LIGHTS; AND EQUIPMENT,
<br />BULKHEAD, WALL, ETC. TO BE REMOVED AND / OR
<br />RELOCATED
<br />4' -TWO - LAMP PLUORE5CENT
<br />LOW -PROFILE WRAP AROUND FIXTURE.
<br />RECESSED LIGHTING.
<br />RECESSED LIGHTING.
<br />COMBINATION EXIT SIGN AND DUALITE
<br />EMERGENCY LAMPS.
<br />EMERGENCY LIGHTING UNIT W/ 2 HEADS.
<br />DUALITE OUTDOOR LXT05 WITH
<br />MINIMUM OF 90 MINUTE BACK-UP
<br />BATTERY. INSTALL ONLY WHEN
<br />REQUIRED BY CODE.
<br />00
<br />zul)
<br />o_l .
<br />F- o
<br />W
<br />J c
<br />f �o
<br />0
<br />O m
<br />U "'
<br />O in
<br />Q Y m
<br />C
<br />Lu } t
<br />a
<br />U L •
<br />m
<br />5TIPLENVO FOR REUSE
<br />THIS DRAWING WA5 SPECIFICALLY
<br />PREPARED FOR USE IN REGARDS TO THE
<br />PERMITTING AND CONSTRUCTION OF THIS
<br />PROJECT AND IS NOT SUITABLE FOR USE
<br />FOR ANY OTHER PROJECT. USE OF THI5
<br />DRAWING FOR REFERENCE OR EXAMPLE
<br />ON ANOTHER PROJECT REQUIRES THE
<br />5ERVICE5 OF PROPERLY LICENSED
<br />ARCHITECTS AND ENGINEERS.
<br />REPRODUCTION OF THIS DRAWING FOR
<br />REUSE ON ANOTHER PROJECT 15 NOT
<br />AUTHORIZED AND MAY 5E CONTRARY TO
<br />THE LAW.
<br />w
<br />u1
<br />N
<br />N
<br />N t6
<br />r
<br />N N
<br />iw
<br />N
<br />0
<br />N
<br />@ U
<br />�-a
<br />co
<br />oN
<br />O
<br />J
<br />J
<br />J
<br />L
<br />zZZ
<br />0
<br />0
<br />0
<br />�o
<br />Ln
<br />cn
<br />Lo
<br />3
<br />a
<br />Lu
<br />a/
<br />al
<br />�'�
<br />w
<br />w
<br />L.3
<br />O
<br />O
<br />O
<br />t L
<br />Lu
<br />COOLER/ FREEZER LIGHTING ® OLO z
<br />i Q
<br />O SPEAKERLL-
<br />3
<br />0o CEILING MOUNTED RECEPTACLE -�
<br /><_On SECURITY CAMERA _ U
<br />DATE ry
<br />C"-y 0-
<br />z
<br />OR SUPPLY DIFF,9bbk _
<br />J� N CD
<br />Il_I
<br />OR z z RETURN AIR GRILLE/ EXHAUST GRILLE. LDG NO, G858
<br />VERSION OR
<br />PROJECTID 751 193-01
<br />u , SCALE O 4'
<br />CITY OF ZE Tly �3 .1 /4" = 11-01,
<br />CEILING SYSTEM LS �, 3), "A Nlr 1
<br />14 TEAM DATE
<br />DGN R.
<br />CE50 OG.242015
<br />RVWP.r ; JAD
<br />bKWG. NO.
<br />G858- D-2
<br />(n U I I I I --- - I I