Laserfiche WebLink
r <br />Y <br />cv <br />Q <br />Ln <br />z <br />c� <br />0 <br />N <br />O <br />0 <br />Ln <br />00 <br />0 <br />O <br />J <br />LIT <br />S <br />S <br />N <br />N 6 <br />�Ln <br />'v <br />Lu = <br />�Q <br />E 5�--I <br />�Q <br />co <br />_o <br />LLJ <br />Lu <br />u� <br />- Ln <br />Ov <br />N W <br />cn 0 <br />HALL <br />109 <br />O <br />6-81 /2" C <br />HT. E.T.R <br />MADE TC <br />COOK <br />104 <br />O <br />8'-8 1 /2" C <br />HT. E.T.R <br />OFFICE <br />103A <br />2 AG-6 <br />8'-9 1 /2" CD <br />HT, E.T.R. <br />OFFICE <br />ca8 <br />9'-2 1 /4" CLG <br />HT. E.T.K. <br />1=I G/- IA/AI V IAI <br />REI=LECTED CEILING PLAN KEY NOTES <br />SECURE TO <br />OVERSIZED TRACK <br />I • <br />EXISTING SOFFIT TO REMAIN. <br />SECURE TO <br />STRUCTURE NOT <br />STRUCTURE ABOVE <br />j <br />DECK <br />SECURED TO <br />2. <br />EXISTING ACT CEILING GRID AND TILES TO REMAIN, REPLACE DAMAGED / DIRTY TILES. <br />BOTTOM OF TRUSS <br />3. <br />NEW ACT CEILING TILES WITHIN EXISTING CEILING GRID. REFER TO LEGEND FOR TILE TYPE. <br />BRACING AS PER <br />4. <br />NEW ACT GRID AND TILES. REFER TO LEGEND FOR TILE TYPE. <br />BULKHEAD BRACING <br />I GATT INSULATION <br />1/2" STEEL ALL <br />GENERAL NOTES <br />R- I I <br />THREAD @ 48 <br />5. <br />NEW TYPE 11 HOOD. REFER TO MECHANICAL DRAWINGS. <br />O.C. <br />STOP GYP. BD. BELOW <br />20 GA. 3-5/8" METAL <br />G. <br />EXISTING DIFFUSER/ GRILLE. REFER TO MECHANICAL DRAWINGS. <br />TRACK SET FRAMING <br />STUDS @ I G" O.C. <br />3-5/6" METAL STUDS <br />BACK 1/6" FROM COOLER <br />_z <br />@ I G" O.C. <br />7- <br />NOT USED <br />SUSPENDED <br />8. <br />EXISTING LIGHT FIXTURES. REFER TO ELECTRICAL DRAWINGS. <br />z ACOUSTICAL CEILING <br />DROP CEILING <br />SUSPENDED <br />PROVIDE 1/2" GAP AND DO NOT <br />SEE CLG. PLAN <br />ACOUSTICAL CEILING <br />9. <br />NEW LIGHT FIXTURES. REFER TO ELECTRICAL DRAWINGS. <br />PENETRATE COOLER PANEL WITH <br />FASTENERS <br />DROP CEILING <br />10. <br />EXISTING EMERGENCY OR EXIT LIGHT. REFER TO ELECTRICAL DRAWINGS. <br />SEE CLG. PLAN <br />SUSPENDED <br />DROP CEILING <br />ACOUSTICAL <br />SEE CLG. PLAN <br />1 1 . <br />NEW EMERGENCY OR EXIT LIGHT. REFER TO ELECTRICAL DRAWINGS. <br />TOP OF COOLER <br />CEILING <br />1�7V.LF. <br />12. <br />NEW BULKHEAD. REFERTO DETAILS ON THIS SHEET. <br />5/8" GYP. BD. PAINTED <br />BTM. BULKHEAD <br />7-2" U.N.O. <br />13. <br />EXISTING EVAPORATOR. <br />COOLER PANELS <br />1 /2" GYP. BD. GLUED <br />14. <br />NO WORK IN THIS AREA, UNLESS NOTED OTHERWISE. <br />SHALL CONFORM TO <br />TO EXPOSED FACE OF <br />5/8" GYPSUM <br />2x4 PLATE <br />FM 48,50. UL 1040, <br />COOLER WALLS <br />BOARD, PAINTED <br />15. <br />PROVIDE PROTECTED LAMP SLEEVE ON ALL BULBS ABOVE FOOD SERVICE EQUIPMENT. <br />NFPA 28G OR UL <br />"BEFORE" INSTALLING <br />1714 <br />DOOR FRAMES <br />I G. <br />NOT USED <br />FLOOR FINISH <br />17. <br />NO- U5ED <br />FINISH FLOOR <br />18. <br />NEW EVAPORATOR. SEE PME DRAWINGS. <br />100'-01, <br />lCt <br />— <br />NOT USED <br />WALK IN CAVE WALL DETAIL <br />SCALE: 3/4" = 1 ' - 0" <br />A DU LKM EAD DETAIL <br />A-2 SCALE: 3/411 = I I - 0" <br />CEILING PLAN GENERAL NOTES <br />A. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND <br />EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION PER ALL APPLICABLE <br />CODES AND THESE DRAWINGS, UNLESS OTHERWISE NOTED. <br />B> CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS NECESSARY TO <br />PROVIDE A COMPLETE AND SERVICEABLE SUSPENDED CEILING SYSTEM. <br />C. BULKHEADS SHALL EXTEND TO BOTTOM OF TRUSSES. 4" (NOM.) STUD <br />WALLS TO BE CONSTRUCTED OF 3G251 25-30 METAL STUDS AND G" (NOM.) <br />STUD WALLS TO BE CONSTRUCTED OF 55051 25-30 METAL STUDS. ALL <br />STUDS SHALL BE SPACED AT I G" O.C. WITH .5/8" MIN. SHEATHING OF <br />PLYWOOD, AND / OR GYPSUM BOARD. SHEATHING SHALL EXTEND TO 8" <br />(MIN.) ABOVE ADJACENT CEILING LINE. CONTRACTOR TO PROVIDE <br />SUFFICIENT BRACING FOR SUPPORT OF BULKHEADS. <br />00 <br />Z in <br />03 <br />F- O <br />W <br />J c <br />a <br />f <br />O m <br />U "I <br />m <br />O <br />z m <br />O_ cn <br />a� <br />Y <br />Q � m <br />W >1! o <br />a <br />U U ' <br />00 <br />�• H <br />ay <br />96 22 ` <br />sr�h'ED <br />STIFULAI I R REUSE <br />THIS DRAWING WAS SPECIFICALLY <br />PREPARED FOR USE IN REGARDS TO THE <br />PERMITTING AND CONSTRUCTION OF THI5 <br />PROJECT AND 15 NOT SUITABLE FOR USE <br />FOR ANY OTHER PROJECT. USE OP THI5 <br />DRAWING FOR REFERENCE OR EXAMPLE <br />ON ANOTHER PROJECT REQUIRES THE <br />SERVICES OF PROPERLY LICENSED <br />ARCHITECTS AND ENGINEERS. <br />REPRODUCTION f TH15 DRAWING FOP <br />/ALK-I N REUSSEON ANOTHER ER PROJECT 5 NOT <br />AUTHORIZED AND MAY BE CONTRARY TO <br />CAVE THE LAW. <br />102A <br />D" CLG. hT. <br />E.T.R. <br />thE <br />LEGEND <br />O 4'-TWO - LAMP FLUORESCENT LOW -PROFILE <br />WRAP AROUND FIXTURE. <br />O 4' LED TROFFER ENCLOSED AND GASKETED. <br />®I G" LED TROFFER ENCLOSED AND <br />O GASKETED. <br />O OR 101 EXISTING/ NEW OPEN CELL PARABOLIC LIGHT <br />PIXTURE. <br />MEWS N= NEW. ALL OTHER LIGHTS ARE EXISTING <br />5TROOM OR RELOCATED UNLESS OTHERWISE NOTED. <br />F-0-7-1 OR O EXISTING/ NEW CLOSED PRISMATIC LENS <br />14 LIGHT FIXTURE. <br />10 I /2" CLG. <br />HT. E.T.R. COMBINATION EXIT SIGN AND DUALITE <br />EMERGENCY LAMPS.o <br />EMERGENCY LIGHTING UNIT W/ 2 HEADS. �2 o� <br />W 41 <br />OMEN'S DUALITE OUTDOOR LXTOS WITH MINIMUM <br />5TROOM OF 90 MINUTE BACK-UP BATTERY. INSTALL <br />I OS , REFLECTED CEILING PLAN I v ONLY WHEN REQUIRED BY CODE. <br />3+ <br />ETR COOLER/ FREEZER LIGHTING � 3 <br />10.1%2" CLG. A-2 SCALE: 1 /4" = I ' - 011 n <br />o N <br />HT. E.T.R. . SPEAKER o <br />x <br />> 2 <br />w �o <br />NORTH SECURITY CAMERA s <br />N� <br />O� U <br />c � <br />0o CEILING MOUNTED RECEPTACLE 21 <br />NL <br />z <br />-Eo <br />OR Z SUPPLY DIFFUSER. _ J <br />Q <br />w <br />Ln <br />OR Z Z RETURN AIR GRILLE/ EXHAUST GRILLE. > m cs-) <br />3 Jm o <br />m -J z <br />EXISTING OR NEW IN AREAS INDICATED J z <br />TYPE "A" SUSPENDED CEILING (24x48x5/8") Q <br />ARMSTRONG ITEM # 1729, FINE FISSURED, J z <br />CLASS A (UL), WHITE, SUSPENSION SYSTEM, <br />PRELUDE 1 5/ 1 G" EXPOSED T. v <br />EXISTING OR NEW IN AREAS INDICATED y m = <br />TYPE "B" SUSPENDED CEILING <br />(24"x48"x5/8") ARMSTRONG ITEM #793, W <br />B GEORGIAN, CLASS A (UL), WHITE, N <br />SUSPENSION SYSTEM, CLEAN ROOM <br />SYSTEM, 1 5/ 1 G" T. <br />STORE OR <br />EXISTING OR NEW IN AREAS INDICATED BLDG NO. 6858 <br />TYPE "C" SUSPENDED CEILING VERSION OR <br />(24"x24"x5/8") ARMSTRONG ITEM # 1726, PROJECT- ID 751 1 93-01 <br />FINE FISSURED, CLASS A (UL), WHITE, SCALE 0 4' <br />SUSPENSION SYSTEM, PRELUDE 1 5/ 1 G" <br />EXPOSED T. 1/4" = 1'-0" <br />EXISTING OR NEW IN AREAS INDICATED DESIGN TEAM DATE <br />TYPE "D" SUSPENDED CEILING <br />DGNR. <br />(24"x24"x5/8") ARMSTRONG ITEM #794, <br />GEORGIAN, CLASS A (UL), WHITE, P.MGR. CE50 OG.24.2015 <br />SUSPENSION SYSTEM, CLEAN ROOM <br />SYSTEM, 15/ 1 G" T RVWR. JAD <br />DRWG. N0. <br />6858- A-2 <br />