Laserfiche WebLink
IN <br />I <br />x..EN U OF bEC I1UN" <br />SECTION 16426 <br />DISTRIBUTION EQUIPMENT <br />PART 1- <br />GENERAL <br />2.01 MATERIALS <br />1.01 WORK <br />INCLUDED <br />A. <br />Outlet boxes shall consist of 4" square deep boxes. Provide minimum 3-1/2" deep boxes <br />unless required otherwise by field conditions. <br />A. <br />Standard and custom products equivalent to Square D, NQOD, NF, I -Line panelboards, <br />B. <br />Provide backboard in telephone equipment rooms consisting of 3/4" deep X 4' wide X 8' <br />and QMB switchboards, as well as safety switches, contactors, and starters. Cutler <br />high AC plywood unless noted otherwise on plans. <br />Hammer, Siemens, and GE are acceptable manufacturers. <br />C. <br />Provide backboards. in tenant spaces consisting of 3/4" deep X 4' wide X 4' high AC <br />plywood unless noted otherwise on plans. <br />PART2-PRODUCTS <br />PART 3 <br />- EXECUTION <br />2.01 MATERIALS <br />3.01 INSTALLATION <br />A. <br />All distribution gear shall have a ground bus. <br />B. <br />For 4-wire systems, the neutral bus shall be the equivalent ampacity as the phase bus bars. <br />A. <br />Provide minimum 1" conduits from outlet boxes to accessible space above ceiling. Where <br />C. <br />Provide permanent plastic nametag indicating name of each switchboard, panelboard, and <br />hard ceilings are installed, route conduit to nearest accessible location. <br />transformer as well as a permanent plastic nametag indicating each load fed for each <br />B. <br />Paint both sides of telephone backboards with 2 coats of fire retardant paint prior to <br />switchboard. <br />installation. <br />D. <br />All panelboards and switchboards shall use bolt -on circuit breaker overcurrent devices. <br />C. <br />Provide (1) 2" conduit from main telephone terminal board to telephone terminal board in <br />E. <br />Provide circuit breakers UL listed as Type HACR for air conditioning equipment branch <br />tenant space. <br />circuits. <br />D. <br />Provide ground bar at each telephone backboard location. Provide a #4 Green copper <br />F. <br />Do not use tandem circuit breakers. <br />ground from each ground bar to main telephone systems ground or to building grounding <br />electrode system. <br />G. <br />Safety switches used for service disconnecting means shall be Heavy Duty, 100,000 AIC <br />E. <br />Provide a pull string in all conduits. <br />minimum. All others may be General Duty. <br />H. <br />Provide Class L fuses for individual motors, 50 hp and larger; Class J for service mains <br />including tenant meter disconnects downstream of mains; Class RK5 fuses for all other <br />***END OF SECTION*** <br />applications. <br />I. <br />Refer to panel schedules for ampacities, voltage, phase, NEMA rating, mounting <br />configuration, AIC rating, and accessories. <br />J. <br />Lighting contactors shall have 30 amp rated contacts, minimum. <br />K. <br />Provide a typewritten panel directory for each panelboard or loadcenter with sufficient <br />detail to distinguish each circuit from all others within the panelboard or loadcenter. <br />L. <br />Where a shared neutral conductor is used for multiple branch circuits, contractor shall <br />group circuits together in panel and provide a manufacturer furnished handle -tie to <br />simultaneously trip all of the circuits sharing the neutral. <br />PART 3 - EXECUTION <br />3.01 INSTALLATION <br />A. Install panelboards plumb with wall finishes with height 6'-6" AFF to top. <br />B. Provide filler plates for unused spaces in panelboards. <br />C. Inspect for physical damage, proper alignment, anchorage, and grounding. Check proper <br />installation and tightness of connections. <br />D. Rigidly mount disconnects and starters adjacent to load served, maintaining working <br />clearance required by NEC. <br />E. Electrical equipment, such as switchboards, panelboards, industrial control panels, meter <br />socket enclosures, and motor control centers, that are in other than dwelling occupancies, <br />and are likely to require examination, adjustment, servicing, or maintenance while <br />energized shall be field marked to warn qualified persons of potential electric arc flash <br />hazards. Provide factory labels to comply. <br />***END OF SECTION*** <br />SECTION 16500 <br />INTERIOR LIGHTING <br />PART 1-GENERAL <br />1.01 QUALITY ASSURANCE <br />A. Comply with NEC requirements as applicable to wiring types and lengths for fixture <br />whips. Provide lighting components and fittings that are UL-listed and labeled. <br />PART 2 - PRODUCTS <br />2.01 MATERIALS <br />A. Lighting fixtures shall be the type indicated on Drawings and as specified. Fixtures of same <br />type shall be of identical make, design, and appearance. Size of lighting fixtures shall be as <br />specified for the lamp or fixture wattage indicated on Drawings. Specific manufacturer and <br />model number references are indicated as a standard of quality and other manufacturers <br />may be supplied provided the product meets or exceeds the specifications. <br />B. Ballasts shall comply with applicable state, federal and industry performance safety <br />standards including FCC requirements governing electromagnetic and radio frequency <br />interference, IEEE standards for line voltage transient protection and harmonic distortion. <br />C. Ballasts shall comply with 2008 NEC 410.130 (G) requirement for integral disconnecting <br />means. <br />D. Provide lamps with lighting fixtures. Lamps shall be as manufactured by General Electric, <br />Philips, Venture, or Sylvania. <br />E. Fluorescent lamps shall be 835. <br />PART 3 - EXECUTION <br />3.01 INSTALLATION <br />A. Clean surfaces of dirt, cement, plaster and debris. Furnish cleansers compatible with <br />material surfaces being cleaned. <br />B. Replace defective lamps and ballasts. <br />C. Support recessed fixtures in ceilings as follows: Fixtures shall be independently supported <br />from structure above using (2) ceiling tie -wires per fixture at diagonal corners. <br />D. Recessed fixtures shall fit snugly against ceilings to prevent light leakage. <br />E. Light fixtures and associated wiring shall be installed in accordance with NEC Article 410. <br />***END OF SECTION** <br />SECTION 16741 <br />TELEPHONE AND DATA SYSTEM <br />PART1-GENERAL <br />1.01 QUALITY ASSURANCE <br />A. Comply with applicable requirements of NEMA and UL standards. Provide products and <br />components that have been UL listed and labeled. <br />PART 2 - PRODUCTS <br />PROJECT DEMOLITION NOTES <br />1. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND BECOME AWARE OF ALL <br />EXISTING CONDITIONS AFFECTING THEIR WORK PRIOR TO BID. <br />2. CONTRACTOR SHALL VERIFY THAT EXISTING ELECTRICAL WORK TO REMAIN IS <br />PROPERLY INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. <br />CONTRACTOR WILL NOT SUBMIT CHANGE ORDER REQUESTS PERTAINING TO <br />CORRECTIVE ACTION FOR THESE ITEMS, RATHER INCLUDE IN ORIGINAL BID ANY <br />COSTS ASSOCIATED WITH CORRECTIVE ACTION. <br />3. CONTRACTOR IS ADVISED THAT EXISTING LOADS AND CONTROLS TO REMAIN <br />INCLUDE HVAC AND EXISTING RECEPTACLES (WHERE COMPATIBLE WITH THE <br />RENOVATION). CARE SHOULD BE TAKEN TO ENSURE THESE LOADS ARE <br />PROPERLY CONNECTED UPON COMPLETION. <br />4. EXISTING CONDUITS, WHERE APPLICABLE, MAY BE REUSED. <br />5. CONTRACTOR SHALL REMOVE THOSE ITEMS WHICH ARE NOT REUSED DUE TO <br />RENOVATIONS AND PROPERLY DISPOSE OF OFF SITE. THIS INCLUDES BUT IS NOT <br />LIMITED TO LINE AND LOW VOLTAGE CONDUCTORS, RACEWAYS, SAFETY <br />SWITCHES, LIGHT FIXTURES, RECEPTACLES, ETC. <br />6. WHERE PANEL SCHEDULES INDICATE NEW CIRCUIT BREAKERS ARE TO BE <br />INSTALLED, CONTRACTOR SHALL MAINTAIN PANELBOARD/LOAD CENTER UL <br />AND AIC RATING. <br />7. CONTRACTOR SHALL REPLACE DEFECTIVE LAMPS AND BALLASTS AND CLEAN <br />LENS/LOUVER/FIXTURE FOR FIXTURES WHICH ARE TO REMAIN. <br />8. CONTRACTOR SHALL SCHEDULE ANY DISRUPTION WHICH MAY OCCUR TO <br />OTHER TENANTS IN THE BUILDING WITH THOSE TENANTS AND THE LANDLORD <br />ONE WEEK PRIOR TO THE REQUIRED EVENT. <br />ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />O <br />CEILING LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />DUPLEX RECEPTACLE. SEE SPECIFICATIONS. <br />16" AFF TO CENTERLINE UON. <br />0 <br />CEILING LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />DUPLEX RECEPTACLE, ABOVE COUNTER. SEE SPECIFICATIONS. <br />44" AFF TO CENTERLINE UON. <br />O -- <br />WALL WASH LIGHT FIXTURE. ARROW INDICATES WASH DIRECTION. <br />SEE FIXTURE SCHEDULE. <br />rn <br />11" <br />DUPLEX RECEPTACLE, ONE-HALF SWITCHED. SEE SPECIFICATIONS. <br />16" AFF TO CENTERLINE UON. <br />4 <br />WALL BRACKET LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />® <br />DUPLEX RECEPTACLE, FLOOR OR POKE-THRU. SEE SPECIFICATIONS. <br />FLUSH IN FLOOR UON. <br />WALL BRACKET LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />_ <br />DOUBLE DUPLEX RECEPTACLE. SEE SPECIFICATIONS. <br />16" AFF TO CENTERLINE UON. <br />Q <br />WALL BRACKET LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />DOUBLE DUPLEX RECEPTACLE, ABOVE COUNTER. SEE SPECIFICATIONS. <br />44" AFF TO CENTERLINE UON. <br />WALL BRACKET LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />T <br />SIMPLEX RECEPTACLE. SEE SPECIFICATIONS. <br />16" AFF TO CENTERLINE UON. <br />WALL MOUNTED SCONCE LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE. <br />SPECIAL RECEPTACLE. NEMA CONFIGURATION AS NOTED. <br />68" AFF TO CENTERLINE UON. <br />Ah <br />WALL MOUNTED SCONCE LIGHT FIXTURE WITH EMERGENCY POWER <br />BACKUP. <br />SEE FIXTURE SCHEDULE. <br />MULTI -OUTLET SURFACE RACEWAY WITH NEMA 5-15R SIMPLEX <br />RECEPTACLES AT 12" CENTERS UON. <br />44" AFF TO CENTERLINE UON. <br />® <br />® <br />V X V LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />no <br />208Y/ 120V OR 240/ 120V PANELBOARD. <br />78" AFF TO TOP. <br />® <br />V X 1' LIGHT FIXTURE WITH. EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />105— <br />277Y/480V PANELBOARD. <br />78" AFF TO TOP. <br />® <br />2' X 2' LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />'� <br />DISCONNECT SWITCH. <br />NEMA/AMPS/POLE/FUSE/VOLTAGE. PROVIDE NEMA 1, 600V UON. <br />AS NOTED. <br />2' X T LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />m <br />MOTOR STARTER. <br />AS NOTED. <br />2' X 4' LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />MJ <br />COMBINATION MOTOR STARTER/DISCONNECT SWITCH. <br />NEMA/AMPS/POLE/FUSE/VOLTAGE. PROVIDE NEMA 1, 600V UON. <br />AS NOTED. <br />2' X T LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />EM4::p <br />ELECTRIC DUCT HEATER. <br />BY OTHERS. <br />SURFACE MOUNTED LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />N <br />MOTOR CONNECTION OR EXHAUST FAN. <br />BY OTHERS. <br />® <br />SURFACE MOUNTED LIGHT FIXTURE WITH EMERGENCY POWER <br />BACKUP. <br />SEE FIXTURE SCHEDULE. <br />Q <br />POWER POLE WITH POWER AND COMMUNICATIONS RACEWAY <br />PROVISIONS AS NOTED. <br />AS NOTED. <br />WALL MOUNTED LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />v <br />COMMUNICATIONS/DATA OUTLET. <br />16" AFF TO CENTERLINE UON. <br />WALL MOUNTED LIGHT FIXTURE WITH EMERGENCY POWER BACKUP. <br />SEE FIXTURE SCHEDULE. <br />® <br />COMMUNICATIONS/DATA OUTLET, FLOOR OR POKE-THRU. <br />FLUSH IN FLOOR UON. <br />I--O-i <br />FLUORESCENT STRIP LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />® <br />COMBINATION COMMUNICATIONS/DATA AND DUPLEX RECEPTACLE <br />OUTLET, FLOOR BOX. <br />FLUSH IN FLOOR UON. <br />FLUORESCENT STRIP LIGHT FIXTURE WITH EMERGENCY POWER <br />BACKUP. <br />SEE FIXTURE SCHEDULE. <br />® <br />COMBINATION COMMUNICATIONS/DATA AND QUAD RECEPTACLE <br />OUTLET, FIRE RATED POKE-THRU. <br />FLUSH IN FLOOR UON. <br />00-- <br />FLOOD LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />P D <br />FURNITURE SYSTEM BASE FEED (POWER AND DATA), REFER TO NOTES <br />AND SPECIFICATIONS. <br />AS NOTED. <br />yy <br />TRACK LIGHT FIXTURE (STRAIGHT). <br />SEE FIXTURE SCHEDULE. <br />4 <br />CABLE TV OUTLET. <br />18" AFF TO CENTERLINE UON. <br />TRACK LIGHT FIXTURE (CURVED). <br />SEE FIXTURE SCHEDULE. <br />4 <br />SECURITY SYSTEM CARD READER OUTLET. <br />48" AFF TO CENTERLINE UON. <br />PENDANT MOUNTED LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />4 <br />SECURITY SYSTEM PUSH -PAD OUTLET. <br />48" AFF TO CENTERLINE UON. <br />ACCENT LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />SECURITY SYSTEM CLOSED CIRCUIT TV CAMERA. <br />AS NOTED. <br />CEILING FAN. <br />SEE FIXTURE SCHEDULE. <br />® <br />FIRE ALARM SYSTEM CONTROL PANEL. <br />78" AFF TO TOP. <br />® <br />SINGLE -FACE CEILING MOUNTED EXIT SIGN WITH AIMING ARROWS AS <br />INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. <br />SEE FIXTURE SCHEDULE. <br />® <br />FIRE ALARM SYSTEM REMOTE ANNUNCIATOR PANEL. <br />66" AFF TO TOP. <br />TWO -FACE CEILING MOUNTED EXIT SIGN WITH AIMING ARROWS AS <br />INDICATED. FILL REPRESENTS READABLE FACE DIRECTION. <br />SEE FIXTURE SCHEDULE. <br />Q <br />FIRE ALARM SYSTEM SMOKE DETECTOR. <br />CEILING UON. <br />WALL MOUNTED EXIT SIGN WITH AIMING ARROWS AS INDICATED. <br />FILL REPRESENTS READABLE FACE DIRECTION. <br />SEE FIXTURE SCHEDULE. <br />s <br />FIRE ALARM SYSTEM DUCT TYPE SMOKE DETECTOR. <br />IN SUPPLY DUCT > 2,000 CFM <br />IN RETURN DUCT > 15,000 CFM <br />WALL MOUNTED EMERGENCY BATTERY PACK LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />FIRE ALARM SYSTEM HEAT DETECTOR. <br />CEILING UON. <br />' <br />COMBINATION EMERGENCY BATTERY LIGHT AND EXIT SIGN WITH <br />.AIMING ARROWS AS INDICATED. FILL REPRESENTS READABLE FACE. <br />SEE FIXTURE SCHEDULE. <br />FIRE ALARM SYSTEM PULL STATION. <br />48" AFF TO CENTERLINE UON. <br />OC] <br />POLE MOUNTED LIGHT FIXTURE. <br />SEE FIXTURE SCHEDULE. <br />T� <br />FIRE ALARM SYSTEM TAMPER SWITCH. <br />FIELD COORDINATE. <br />SINGLE -POLE TOGGLE SWITCH. <br />48" AFF TO CENTERLINE UON. <br />❑F <br />FIRE ALARM SYSTEM FLOW SWITCH. <br />FIELD COORDINATE. <br />$2 <br />TWO -POLE TOGGLE SWITCH. <br />48" AFF TO CENTERLINE UON. <br />® <br />FIRE ALARM SYSTEM RELAY CONTROL MODULE. <br />FIELD COORDINATE. <br />$3 <br />THREE-WAY TOGGLE SWITCH. <br />48" AFF TO CENTERLINE UON. <br />M❑ <br />FIRE ALARM SYSTEM MONITORING MODULE. <br />FIELD COORDINATE. <br />$4 <br />FOUR-WAY TOGGLE SWITCH. <br />48" AFF TO CENTERLINE UON. <br />❑D <br />FIRE ALARM SYSTEM MAGNETIC DOOR HOLDER. <br />ON WALL 6" BELOW TOP OF <br />DOOR. <br />$° <br />OCCUPANCY SENSOR SWITCH. <br />48" AFF TO CENTERLINE UON. <br />FIRE ALARM SYSTEM HORN. <br />80" AFF TO BOTTOM. <br />$M <br />MOMENTARY CONTACT TOGGLE SWITCH. <br />48" AFF TO CENTERLINE UON. <br />® <br />FIRE ALARM SYSTEM STROBE, 75 CANDELA UON. <br />80" AFF TO BOTTOM. <br />$T <br />TIMER SWITCH. <br />48" AFF TO CENTERLINE UON. <br />FIRE ALARM SYSTEM HORN/STROBE, 75 CANDELA UON. <br />80" AFF TO BOTTOM. <br />0100 <br />DIMMER SWITCH. PROVIDE WATTAGE RATING INDICATED. <br />48" AFF TO CENTERLINE UON. <br />FIRE ALARM SYSTEM CEILING MOUNTED HORN/STROBE, 75 CANDELA <br />UON. <br />SURFACE ON CEILING. <br />CEILING MOUNTED OCCUPANCY SENSOR SWITCH. <br />CEILING UON. <br />u <br />FIRE ALARM SYSTEM MINI -HORN. <br />80" AFF TO BOTTOM. <br />0 <br />JUNCTION BOX OR OUTLET BOX. <br />AS NOTED. <br />R <br />FIRE ALARM SYSTEM BELL. <br />96" AFF TO TOP UON. <br />-----II- <br />GROUND ROD. <br />AS NOTED. <br />o • <br />UP DN <br />CONDUIT RUN UP OR DOWN AS NOTED. <br />\ <br />CONDUIT CONCEALED IN WALL OR ABOVE CEILING. <br />SEE SPECIFICATIONS. <br />PHASE, NEUTRAL, EQUIPMENT GROUND, AND ISOLATED GROUND. <br />ALL HOMERUNS SHALL BE 1/2" CONDUIT WITH 3 #12 UON. <br />1' <br />CONDUIT CONCEALED IN SLAB OR UNDERGROUND. <br />SEE SPECIFICATIONS. <br />00 <br />REFER TO KEYED NOTES. <br />------- <br />CONDUIT EXPOSED ON WALL OR CEILING. <br />SEE SPECIFICATIONS. <br />ABBREVIATIONS <br />ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR. <br />HID <br />HIGH INTENSITY DISCHARGE. <br />AFG <br />ABOVE FINISHED GRADE. <br />HP <br />HORSEPOWER. <br />ATS <br />AUTOMATIC TRANSFER SWITCH. <br />IG <br />ISOLATED GROUND.' <br />BFG <br />BELOW FINISH GRADE. <br />LCP <br />LIGHTING CONTROL PANEL <br />C <br />CONDUIT. <br />LSIG <br />LONG, SHORT, INSTANTANEOUS, GROUND FAULT TRIP SETTINGS. <br />CLG <br />CEILING MOUNTED. <br />N <br />NEW. <br />DN <br />CONDUIT DOWN. <br />NEUT <br />NEUTRAL. <br />E <br />EXISTING. <br />NF <br />NON -FUSED. <br />EC <br />ELECTRICAL CONTRACTOR. <br />NL <br />NIGHT LIGHT. <br />EG <br />EQUIPMENT GROUND. <br />NP <br />NAMEPLATE. <br />EXP <br />EXPLOSION PROOF. <br />PNL <br />PANEL. <br />EWC <br />ELECTRIC WATER COOLER. <br />RE <br />RELOCATED. <br />EWH <br />ELECTRIC WATER HEATER. <br />UON <br />UNLESS OTHERWISE NOTED. <br />FTL <br />FEED THRU LUGS (FEED DOWNSTREAM SECTION WITH IDENTICAL FEEDER AS PREVIOUS SECTION) <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY. <br />GEC <br />GROUNDING ELECTRODE CONDUCTOR. <br />WP <br />WEATHERPROOF. <br />GFI <br />GROUND FAULT INTERRUPTER (BREAKER) / GROUND FAULT CIRCUIT INTERRRUPTER (RECEPTACLE). <br />XFMR <br />TRANSFORMER <br />3 <br />11eiEwlaf <br />ee +s <br />\G E SF <br />No. 22 <br />-.0 STATE OF <br />s <br />X <br />w <br />I— <br />Z <br />L.LI <br />U <br />Q <br />0 <br />z <br />_J <br />o <br />J� <br />0 <br />_J <br />Iz <br />O <br />J <br />O <br />ILL <br /><= <br />W <br />>: <br />�-- <br />w <br />>- <br />Z <br />LIJ <br />� <br />Q <br />= <br />O <br />U <br />0 <br />Qcn <br />�+ <br />W <br />a <br />N <br />w <br />Z <br />O <br />i— <br />SAVE-A-LOT <br />TENANT BUILD -OUT <br />RENOVATION <br />PROJECT ADDRESS: <br />TOWNVIEW SQUARE SHOPPING CENTER <br />7320 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />PASCO COUNTY <br />SUPERVALU <br />COMPANY <br />CLIENT ADDRESS: <br />100 CORPORATE OFFICE DR. <br />EARTH CITY, MISSOURI <br />DATE DESCRIPTION <br />09-02-10 OWNER REVIEW <br />09-08-10 PERMIT DRAWINGS <br />LEGEND AND SPECIFICATIONS <br />ASH <br />PROJECT #: 710-009 <br />E002 <br />09-02-10 <br />