Laserfiche WebLink
4 <br />'URB <br />ILS, & <br />� LUUU ULU <br />1 /8" - 1 `- 0" <br />FLOOR PEAK LEGEND <br />GENERAL (VOTES <br />VVALL,PARTMOIV TYPES <br />EXISTING WALLS TO REMAIN MAY NOT BE NOTED. ALL TYPES MAY NOT BE USED. <br />1. ALL CHANGES TO THE DRAWINGS MUST BE APPROVED BY SAVE-A-LOT'S PROJECT <br />5/8" GYPSUM BOARD (EACH SIDE) ON 3 5/8" METAL STUDS (24 GA.) AT 16" O.C. W/ ACOUSTIC BATT INSULATION FRICTION FIT TO <br />O1 DOOR -SEE A400 <br />MANAGER, <br />TOP OF STUD. EXTEND STUDS (AND GYP. - SALES SIDE ONLY) TO EXISTING STRUCTURE ABOVE. EXTEND GYP. ON <br />2. A SEPARATE SIGN PERMIT SHALL BE OBTAINED BY THE SIGN INSTALLER FOR STOREFRONT <br />OFFICE/BREAKROOM/TOILET ROOM SIDE TO 12 ABOVE CEILING. USE MOISTURE RESISTANT GYP. ON RESTROOM SIDE. LEVEL 4 FINISH. <br />FE GC TO PROVIDE 1 F.E. PER 3000 SF PER 2007 FBC AND <br />SIGN. <br />3. ALL NEW HARDWARE TO BE ADA APPROVED. <br />SAME AS TYPE 1 EXCEPT NO BATT INSULATION <br />El <br />A MIN. TO ENSURE A TRAVEL DISTANCE OF NO MORE <br />4. INSTALL 3/4" PLYWOOD 8'-0" HIGH ON ALL EXPOSED GYPSUM BOARD. <br />THAN 75 FT. <br />5. THE COOLERS AND FREEZERS, AS SUPPLIED BY THE MANUFACTURER CERTIFIED INSTALLER, <br />SHALL BE LINER SEPARATE PERMIT. ELECTRICAL POWER FOR THE COOLERS HAS BEEN <br />5/8" GYPSUM BOARD (EACH SIDE) ON 3 5/8" METAL STUDS (24 GA.) AT 16" O.C. W/ ACOUSTIC BATT INSULATION FRICTION FIT TO <br />X WALL TYPE <br />DESIGNED AND IS INDICATED ON THE ELECTRICAL DWGS. <br />TOP OF STUD, EXTEND TO 12" ABOVE CEILING. USE MOISTURE RESISTANT GYP. ON RESTROOM SIDE. SEE OFFICE/BREAKROOM <br />6. NEW ADA RESTROOMS ARE LOCATED IN THE PROCESSING AREA AND ARE ACCESSIBLE TO <br />PARTITION DETAIL A400. LEVEL 4 FINISH. <br />THE PUBLIC PER FBC 11-4.3.1. <br />7. PROVIDE TACTILE SIGNAGE AT EACH DOOR REQUIRING AN EXIT SIGNAGE TO BE MOUNTED ON <br />2A SAME AS TYPE 2 EXCEPT NO BATT INSULATION <br />LATCH SIDE OF DOOR, 60" AFF. (NFPA 101-7.10.1.3). <br />5/8" GYPSUM BOARD (EACH SIDE) ON 3 5/8" METAL STUDS (24 GA.) AT 16" O.C. W/ ACOUSTIC BATT INSULATION FRICTION FIT TO <br />8. MICRO SET/ROLLING FIXTURES INCLUDING (2) MAST, (2) TWR, AND 2'X2' BLACKHAWK <br />TOP OF STUD, EXTEND TO EXISTING STRUCTURE ABOVE. SEE SALES/BACK ROOM PARTITION DETAIL A400. LEVEL 4 FINISH. <br />(PHONECARD) TO BE LOCATED IN FRONT OF THE CHECKSTANDS UNLESS OTHERWISE <br />DIRECTED BY THE DISTRICT MANAGER OR REGIONAL DIRECTOR. <br />9. EXISTING FIRE RISER FOR THE SPRINKLER SYSTEM IS IN THE ADJACENT SPACE. GC/SUB <br />5/8" GYPSUM BOARD ON 2 1/2" METAL STUDS (24 GA.) AT 16" O.C. ON EXST. CMU WALL. EXTEND TO 12" ABOVE CEILING. USE <br />MOISTURE RESISTANT GYP. ON RESTROOM SIDE. LEVEL 4 FINISH. <br />FI V S H SCHEDULE <br />TO SECURE PERMITS REQUIRED TO MODIFY SPRINKLER HEADS PER THE CURRENT LAYOUT. <br />10. REPAIR PERIMETER DRYWALL. <br />11. RE -LOCATED LIFT AT RECEIVING. <br />5/8" GYPSUM BOARD (EACH SIDE) ON 6" METAL STUDS (24 GA.) AT 16" O.C. W/ ACOUSTIC BATT INSULATION FRICTION FIT TO TOP <br />OF STUD. EXTEND TO 12" ABOVE CEILING. USE MOISTURE RESISTANT GYP. ON RESTROOM SIDE. LEVEL 4 FINISH. <br />SEE SCOPE OF WORK SHEET A002 AND FINISH SCHEDULE <br />12. GC TO PROVIDE/INSTALL A WALK -OFF MAT AT THE FRONT ENTRY (APPROX. 8'-0" OFF THE <br />E] 5/8" GYPSUM BOARD ON 3 5/8" METAL STUDS (24 GA.) AT 16" O.C. ON EXST. CMU WALL. EXTEND TO 12" ABOVE <br />SHEET A400 FOR FINISH INFORMATION <br />FRONT DOOR TIMES THE WIDTH OF THE FRONT DOOR). COORDINATE WITH SAL PROJECT <br />CEILING. USE MOISTURE RESISTANT GYP. ON RESTROOM SIDE. LEVEL 4 FINISH. <br />MANAGER. <br />13. NEW OVERHEAD DOOR IN DOCK AREA. FRAMING AND FASTENERS PER PRODUCT APPROVAL <br />F7] 8" CMU INFILL IN EXST. OPENING (NEW CMU TO MATCH EXISTING). WALL TO HAVE MIN. 1-HR. FIRE RATING PER UL DETAIL 914. <br />DRAWINGS. FOR DOOR LINTEL PROVIDE W8X15 STEEL BEAMS WITH 11x1/2" CONTINUOUS <br />STEEL PLATE WELDED TO BOTTOM W/ 8" MIN. BEARING EACH END. JAMBS TO BE STEEL <br />5/8" GYPSUM BOARD (EACH SIDE) ON 6" METAL STUDS (24 GA.) AT 16" O.C. W/ ACOUSTIC BATT INSULATION FRICTION FIT TO TOP <br />a <br />CHANNELS - WELD TO LINTEL AND SECURE AT BOTTOM WITH CLIP ANGLES AND TWO 5/8" <br />OF STUD. EXTEND STUDS AND GYP. TO EXISTING STRUCTURE ABOVE. INSTALLATION TO MEET 1 HOUR FIRE RATING PER UL DETAIL U <br />EXPANSION BOLTS. PROVIDE SHORES FOR EXISTING WALL PRIOR TO REMOVING MASONRY <br />419 (AS SHOWN ON SHEET A/100). LEVEL 4 FINISH. <br />UNITS. <br />EXISTING WALL TO REMAIN <br />e <br />ARTISTIC SOLUTIONS HALO, INC. <br />(CONSULTANTS) <br />ASHLEIGH ADAMOSKY <br />6822 22ND AVE. N. <br />SUITE 335 <br />ST. PETERSBURG, FL 33710 <br />813-495-0917 <br />ASHBO76@HOTMAIL.COM <br />w <br />Q <br />Z <br />N <br />Q <br />jlA� t <br />_ <br />r) <br />/ <br />N <br />N <br />Q <br />z J <br />z <br />o <br />S <br />U <br />Q <br />w <br />H <br />z <br />w <br />U <br />o Z <br />J <br />a � <br />J o <br />J= = LL <br />w 0 <br />Q� w <br />�w N a <br />z <br />O <br />SAVE -A -LOT <br />TENANT BUILD -OUT <br />RENOVATION <br />PROJECT ADDRESS: <br />TOWNVIEW SQUARE SHOPPING CENTER <br />7320 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />PASCO COUNTY <br />SUPERVALU <br />COMPANY <br />CLIENT ADDRESS: <br />100 CORPORATE OFFICE DR. <br />EARTH CITY, MISSOURI <br />DATE I DESCRIPTION <br />09-09-101 PERMIT DRAWINGS <br />FLOOR PLAN <br />ASH <br />PROJECT #: 710-009 <br />Al <br />01 <br />09-09-10 <br />