OVERALL UNIT PLANS LAYOUT - RENOVATION - ELECTRICAL <br />1 /4" =1'-0" <br />GENERAL NOTES: <br />1. REFER TO RISER DIAGRAM, ELECTRICAL DETAILS AND PANEL <br />SCHEDULES FOR MORE INFORMATION. <br />2. COORDINATE ALL DEVICE/LIGHT LOCATIONS WITH <br />ARCHITECTURAL DRAWINGS AND DIAGRAMS PRIOR TO ROUGH <br />IN. <br />3. PROVIDE NEW NAME ENGRAVED COVER PLATES INDICATING <br />SUPPLY PANEL AND CIRCUIT NUMBER(S) FOR ALL ELECTRICAL <br />DEVICES IN THIS PROJECT, ENGRAVING SHALL BE RED FOR <br />CRITICAL AND BLACK FOR NORMAL CIRCUITS. <br />4. PROVIDE NEW TYPED PANEL SCHEDULES FOR ALL PANELS <br />USED IN THIS PROJECT. <br />5. PROVIDE PHENOLIC NAMEPLATES ON ALL PANELBOARDS, <br />SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, ETC, <br />INDICATING DESIGNATION, CIRCUIT NUMBER(S), VOLTAGE AND <br />WHERE UNIT IS FED FROM, SECURE NAMEPLATES WITH AT <br />LEAST TWO SCREWS OR RIVETS. CEMENTING AND ADHESIVE <br />INSTALLATION WILL NOT BE ACCEPTABLE. NAMEPLATES SHALL <br />BE COLORED AS PER SPECIFICATIONS. <br />6. WALL MOUNTED SWITCHES FOR LIGHTING IN RESIDENT AREAS <br />SHALL BE "QUIET" OPERATING TYPE. <br />7. ALL JUNCTION BOXES (NEW AND EXISTING) IN CEILING SPACE <br />MUST BE LOCATED OUTSIDE OF HARD CIELINGS AND ABOVE AN <br />ACCESSIBLE CEILING OR PROVIDE ACCESS PANELS WHERE J- <br />BOXES ARE WITHIN ARMS REACH. THE REMOVAL OF A LIGHT <br />FIXTURE FOR ACCESS WILL NOT BE ACCEPTABLE INSIDE LAB. <br />LOCATE NEW J-BOXES ABOVE ACCESSIBLE CEILINGS OR <br />CORRIDORS. RELOCATE ALL EXISTING J-BOXES ABOVE AREA <br />OF WORK. PROVIDE ALL NECESSARY ACCESS PANELS. <br />KEY NOTES: <br />NIGHT STAND SHALL BE PROVIDED WITH A FIXED LAMP FOR <br />USE AS GENERAL LIGHTING. LAMP SHALL HAVE SWITCH <br />CONTROL CONVENIENT FOR USE AT THE LUMINARY. <br />PROVIDED BY OWNER. <br />NURSE CALL SYSTEM DOES NOT CONTROL LIGHTING OR TV. <br />UTILIZE EXISTING SYSTEM, DOME LIGHTS ARE EXISTING. <br />❑3 COORDINATE EXACT MOUNTING HEIGHT OF RECEPTACLE, TV <br />OUTLETS, CABLE OUTLET WITH ARCHITECTURAL ELEVATIONS <br />PRIOR TO ROUGH -IN. <br />® REFER TO HEADWALL ELEVATION DETAIL ON THIS SHEET. <br />0 BED SHOWN AT ANGLE IS ALTERNATE BED LOCATION. TYPICAL <br />ALL. <br />© PATIENT BED LIGHT IS 4-WAY SWITCHED WITH PULL CHAIN. <br />FIXTURE WILL BE CONNECTED/CONTROLLED VIA NEW NURSE <br />CALL SYSTEM ADDED IN A FUTURE PROJECT, <br />CEILING <br />CRITICAL NORMAL <br />ONE (1) ONE (1) <br />CIRCUIT CIRCUIT <br />IN I@ II 11 <br />� II 11 II II <br />CRA NA <br />PATIENT BED <br />48" MIN. 48" MIN. <br />PATIENT STATIO <br />FLOOR <br />NOTES: <br />1. ALL RECEPTACLES AT THE HEADWALL SHALL BE HOSPITAL GRADE. <br />2. ALL DEVICE LOCATIONS AT THE HEADWALL SHALL BE COORDINATED WITH ARCHITECTURAL MILLWORK PRIOR TO ROUGH -IN. <br />A. PROVIDE A MINIMUM OF FOUR (4) DUPLEX RECEPTACLES FOR EACH PATIENT BED (DIVIDED ON BOTH SIDES OF THE BED). <br />B. TWO (2) RECEPTACLES SHALL BE CONNECTED TO CRITICAL BRANCH POWER. RECEPTACLES AND COVERS SHALL BE RED. <br />C. TWO (2) RECEPTACLES SHALL BE CONNECTED TO NORMAL BRANCH POWER. <br />D. THERE SHALL NOT BE MORE THAN SIX (6) DUPLEX RECEPTACLES PER CIRCUIT. <br />E. CRITICAL BRANCH CIRCUITS SHALL BE FROM THE SAME PANEL BOARD. <br />F. NORMAL BRANCH CIRCUITS SHALL BE FROM THE SAME PANEL BOARD. <br />G. ALL RECEPTACLE COVERS SHALL HAVE ENGRAVED COVER PLATES PER SPECS TO INDICATE THE PANEL BOARD AND CIRCUIT <br />NUMBERS SERVING THAT DEVICE. <br />H. PANEL BOARD WITH BRANCH CIRCUIT OVER -CURRENT DEVICES SHALL BE READILY ACCESSIBLE TO NURSING STAFF AND <br />AUTHORIZED PERSONNEL. <br />HEADWALL ELEVATION DETAIL <br />SCALE: NONE <br />Peninsula Engineering, INC. <br />MEP&FP <br />PENINSULA <br />ENGINEERING <br />INC. <br />2016 ALDEN ROAD <br />ORLANDO, FL 32803 <br />CA 3089 <br />VOICE: (407) 246.1688 <br />FAX: (407) 246.1664 <br />http://www.peifia.com <br />Email to., pefteifla.com <br />JOB #: 15384 <br />Copyright -All ideas, designs, <br />methods and plans Indicated or <br />represented by this drawing are <br />owned by and the property of <br />Peninsula Engineering, Inc. and <br />were created, evolved and <br />developed for use on and in <br />connection with the specified <br />project. None of the ideas, <br />designs, arrangements, methods <br />or plans shall be used by or <br />disclosed to any person, firm or <br />corporation for any purpose <br />whatsoever without the written <br />permission of Peninsula <br />Engineering, Inc. <br />©opyright <br />2015 <br />ARCHISPEC, INC <br />ARCHITECTURAL SPECIFICATIONS <br />653 Mallory Hill Drive Lady Lake, FL 32162 <br />P: 352.430.0987 <br />REVISIONS: <br />1 <br />1 07/29/16 <br />JAHCA COMMENTS <br />2 <br />1 11/23/16 <br />1 REVISION #1 <br />ENGINEER OF RECORD: <br />tIIiIII11111 <br />G S Pq 0® <br />.o i No. 64601 i s <br />STATE OF Ir <br />d � •rrrrrrro �.:7`� <br />.9/0 <br />NA' '�ao% <br />Bryan G. Spangler, PE, <br />FL Reg. No. 64601 <br />PROJECT TITLE: <br />ADVENTIST CARE CENTERS <br />ZEPHYRHILLS HEALTH & REHAB <br />CENTER -10 BED SKILLED <br />NURSING BED CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY ROAD, ZEPHYRHILLS FL. 33504 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />OVERALL UNIT PLANS LAYOUT - <br />RENOVATION - ELECTRICAL <br />PROJECT NORTH TRUE NORTH <br />E502 <br />71/ <br />© 2015 Studio+ <br />CAUsers\kinae\Documents\15384 ZEPHYRHILLS HEALTH & REHAB CENTER Klnae.rvt <br />