Laserfiche WebLink
LEGEND <br />A GRID # <br />00 <br />PARTITION CALLOUT <br />00 KEYNOTE # <br />A101 DR # CALLOUT <br />OWIN # CALLOUT <br />CLG HT AFF <br />FURNITURE / <br />EQUIPMENT TAG <br />DOOR ELECTRICAL DEVICE <br />BLDG/PAVING ELEV <br />FEC <br />FIRE EXTINGUISHER CABINET <br />FE <br />FE FIRE EXTINGUISHER <br />W NORTH ARROW <br />LOCATION # 1 SIM / <br />1 <br />SHEET # 101 <br />DET CALI.OUT <br />LOCATION # 1 SIM <br />SHEET # 101 <br />BLDG/WALL/DTL SECT CUT <br />Al <br />LOCATION # 71b Aa Ao.00 Az <br />SHEET # <br />A3 INT ELEV CALLOUT <br />•������������• DEAD END CORRIDOR <br />COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TRAVEL DISTANCE TO EXIT <br />DEMOLISHED PARTITION <br />EXISTING PARTITION <br />NEW PARTITION <br />1 HOUR CONSTRUCTION BARRIER - <br />REFER TO PARTITION TYPES <br />A x X®x x x FRP TEMP. BARRIER. <br />1 HR RATED <br />.:::.:::..::.::::::::.::::::::: WALL/PARTITION <br />.....................................:.................................... <br />2 HR RATED <br />_....___________.____..._.. _... _ WALL/PARTITION <br />3 HR RATED <br />___._.....__._._..._ ___ _......._. WALL/PARTITION <br />4 HR RATED <br />___....__.._.._.__--- --- -,------ WALL/PARTITION <br />4, ......... SMOKE TIGHT <br />WALL/PARTITION <br />AREA NOT IN CONTRACT <br />CEILING GRID <br />LIGHT FIXTURES PER ELEC <br />zDIFFUSERS PER MECH <br />O <br />SPRINKLER <br />EXIT SIGN <br />OWALL FINISH <br />WALL BASE FINISH <br />FLOOR FINISH <br />BUILDING INFORMATION <br />CONSTRUCTION TYPE <br />V-A <br />AUTOMATIC SPRINKLERS <br />YES _— <br />NUMBER OF STORIES <br />1 <br />1 ST FLOOR GROSS AREA <br />+/- 54,670 SF <br />EXISTING USE GROUP (FBC CH 3) <br />INSTITUTIONAL (1-2) <br />PROPOSED USE GROUP (FBC CH 3) <br />INSTITUTIONAL (1-2). NO CHANGE. <br />SCOPE OF WORK <br />5,626 SF <br />EXISTING FUNCTION OF SPACE (FBC TABLE 1004.1.2) <br />INSTITUTIONAL (1-2) (ASSISTED LIVING FACILITY) <br />PROPOSED FUNCTION OF SPACE (FBC TABLE 1004.1.2) <br />INSTITUTIONAL (1-2) (SKILLED NURSING) <br />OCCUPANCY CALCULATION (FBC TABLE 1004.1.1) <br />REFER TO OCCUPANCY CALCULATIONS ON LS1.2 <br />APPLICABLE CODES - FLORIDA <br />5TH EDITION 2014 FLORIDA BUILDING CODE <br />5TH EDITION 2014 FLORIDA EXISTING BUILDING CODE _ <br />FBC TEST PROTOCOLS FOR HIGH VELOCITY HURRICANE ZONES 2014 <br />5TH EDITION 2014 FLORIDA PLUMBING CODE <br />5TH EDITION 2014 FLORIDA MECHANICAL CODE <br />FBC FUEL GAS CODE 2014 <br />5TH EDITION 2014 FLORIDA ENERGY CONSERVATION CODE <br />FGI GUIDELINES FOR HELATH CARE CONSTRUCTION <br />5TH EDITION 2014 FLORIDA ACCESSIBILITY CODE <br />FLORIDA FIRE PREVENTION CODE, FIFTH EDITION (CHAPTER 19 EXISTING HEALTHCARE OCCUPANCIES), <br />2014 <br />NFPA-101, LIFE SAFETY CODE 2012 EDITION <br />NFPA-1, UNIFORM FIRE CODE 2012 EDITION <br />FLORIDA STATE FIRE MARSHAL'S RULE 69A3.012 F.A.C. (8/8/2005) <br />NFPA-10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2010 <br />NFPA-13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2010 <br />NFPA-70, NATIONAL ELECTRICAL CODE 2011 <br />NFPA-72, NATIONAL FIRE ALARM CODE 2010 <br />NFPA-80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS 2010 <br />NFPA-99, STANDARD FOR HEALTH CARE FACILITIES 2012 <br />NFPA-221, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS 2012 <br />NFPA-251, STANDARD METHODS OF TESTS OF FIRE ENDURANCE OF BUILDING CONSTRUCTION AND <br />MATERIALS 2006 <br />NFPA-253, STANDARD METHOD OF TEST FOR CRITICAL FLUX OF FLOOR COVERING SYSTEMS USING A <br />RADIANT HEAT ENERGY SOURCE 2011 <br />NFPA-255, STANDARD METHOD OF TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS <br />2006 <br />NFPA-703, STANDARD FOR FIRE RETARDANT IMPREGNATED WOOD AND FIRE RETARDANT COATINGS FOR <br />BUILDING MATERIALS 2012 <br />TYPICAL DEVICE MOUNTING DIAGRAM <br />6" U <br />CL <br />EDGE OF DOOR OR WALL <br />FIRE STROBE <br />I <br />THERMOSTAT <br />WALL PROTECTION, <br />- -� (WHERE OCCURS) <br />TELEPHONE OR SECOND <br />ROW OF SWITCHES. <br />PROXIMITY & KEYPAD (CORR. SIDE) <br />SECURITY ALARM KEYPAD (RM SIDE) <br />GANG OF DIMMER SWITCHES <br />LIGHT SWITCH, DOOR RELEASE <br />BUTTON <br />WALL PROTECTION, <br />(WHERE OCCURS) <br />ELEC/DATA OUTLETS <br />DEVICE MOUNTING HIGHT <br />DIAGRAM AT EDGE CONDITIONS. <br />w <br />m <br />O <br />Uj <br />U) <br />u_ <br />O <br />- <br />2 <br />O <br />tam <br />O <br />m <br />O <br />f <br />w <br />> <br />J <br />m <br />- <br />rn <br />M <br />ly- <br />0 <br />O <br />N <br />M <br />EQ EQ COLUMN <br />FIRE STROBE <br />THERMOSTAT <br />WALL PROTECTION, <br />(WHERE OCCURS) <br />TELEPHONE OR SECOND <br />ROW OF SWITCHES. <br />LIGHT SWITCH, DOOR <br />RELEASE BUTTON <br />WALL PROTECTION, <br />(WHERE OCCURS) <br />0i-dELEC/DATA OUTLETS <br />I I <br />DEVICE MOUNTING HIGHT DIAGRAM <br />AT COLUMN CONDITIONS. <br />NOTE: PROVIDE 6" MIN DIMENSION BETWEEN WALL MOUNTED DEVICES WHEN <br />LOCATED BACK TO BACK. PROVIDE 2" BETWEEN WALL MOUNTED DEVICES WHEN <br />LOCATED ADJACENT TO EACHOTHER AND AT THE SAME MOUNTING HEIGHT. <br />CONTRACTOR TO COORDINATE LOCATION OF STUDS IN PARTITION TO ACHIEVE <br />INTENT. PROVIDE ADDITIONAL STUDS/BRACING AS NEEDED. PROVIDE <br />SOUNDLINERS AT DEVICE BACK BOXES WHERE DEVICES ARE LOCATED IN <br />PARTITIONS WITH INSULATION. <br />GENERALNOTES- PROJECT <br />COORDINATE METHOD OF TRANSPORTING ALL EQUIPMENT, INCLUDING SIEMONS EQUIPMENT, INTO THE BUILDING AND TO THE AREA OF WORK. REFER TO PACKAGING AND <br />TRANSPORT PATH ON SHEET A-101 OF SIEMONS DRAWINGS. <br />A <br />ALL DOCUMENTS AND DRAWINGS INCLUDED HEREWITH ARE INTENDED TO BE IN CONFORMANCE WITH ALL APPLICABLE CODES AND BUILDING REGULATIONS HAVING <br />JURISDICTION OVER THIS TYPE OF FACILITY AND OCCUPANCY. IF A CONFLICT BETWEEN SUCH REQUIREMENTS OCCUR, THE MOST STRINGENT WILL GOVERN. <br />B <br />GENERAL CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY AND DOCUMENT ALL EXISTING FIELD CONDITIONS. ANY DEVIATIONS FROM THE EXISTING CONDITION DRAWINGS WILL <br />BE ADDRESSED IMMEDIATELY WITH THE ARCHITECT. <br />C <br />PRIOR TO COMMENCING ANY WORK THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATION OF ALL UTILITY POINTS OF CONNECTION AND INCLUDE ALL <br />ASSOCIATED WORK SUCH AS REPAIR / REPLACEMENT OF FINISHES WHERE NECCESSARY. <br />D <br />ALL BUILDING SYSTEM SERVICES (IE: WATER, SANITARY, FIRE ALARM, ELECTRIC, ETC...) WILL REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. ALL NECESSARY <br />INTERRUPTIONS FOR CONNECTION OF NEW WORK WILL BE PERFORMED AFTER NORMAL BUSINESS HOURS OR AS AGREED TO BY BUILDING OWNER. ANY REQUIRED <br />INTERRUPTIONS OF SERVICE WILL BE SCHEDULED AND APPROVED BY THE BUILDING OWNER 72 HOURS IN ADVANCE. ALL COST IMPACTS FOR AFTER HOURS WORK WILL BE <br />ANTICIPATED AND INCLUDED IN BID PROPOSAL. <br />E <br />CONTRACTOR WILL USE ONLY THOSE ENTRANCES AND PARKING FACILITIES ASSIGNED BY THE BUILDING OWNER FOR SITE ACCESS. ALL MATERIAL DELIVERIES WILL BE <br />SCHEDULED TO MINIMIZE DISRUPTIONS TO THE BUILDING OCCUPANTS. <br />F <br />GENERAL CONTRACTOR WILL SCHEDULE ALL WORK TO AVOID INTERRUPTIONS TO ADJACENT AREAS. ALL DISRUPTIVE WORK WILL BE SCHEDULED AND PERFORMED BEFORE OR <br />AFTER NORMAL BUSINESS HOUR. WORK STOPPAGE DUE TO VIBRATIONS, OR THAT DISTURB THE OCCUPANTS OF THE FACILITY WILL NOT BE GROUNDS FOR ADDITIONAL CHARGES <br />OR CHANGE ORDERS. <br />G <br />ALL EXISTING MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEMS NEEDED TO MAINTAIN CONTINUOUS OPERATIONS OF THE FACILITY, WILL BE CAPPED OFF <br />OR REROUTED AS NECESSARY. <br />H <br />IF SCOPE OF WORK REQUIRES THE REMOVAL OF FIXTURES OR DEVICES, ALL ASSOCIATED WIRE, BOXES, FRAMING AND PIPING NECESSARY TO ALLOW THE COMPLETE <br />INSTALLATION OF NEW FINISHES WILL BE REMOVED ALSO. <br />I <br />ALL SMOKE AND FIRE RATED WALLS WILL BE LABELED ABOVE THE CEILING FINISH WITH RED, PAINTED STENCILED LETTERING IDENTIFYING THE WALL RATING AND STATING <br />"PROTECT ALL PENETRATIONS." STENCILED LABELING WILL OCCUR ON BOTH SIDES OF EACH SMOKE AND FIRE RATED WALL AT NOT MORE THAN 20 FEET ON CENTER AND ALL <br />WALL TERMINATIONS OR CHANGES IN DIRECTION WILL BE DESIGNATED WITH A VERTICAL LINE. <br />J <br />SHOP DRAWINGS AND / OR SUBMITTALS FOR PRODUCTS, MATERIALS, ASSEMBLIES, AND SYSTEMS SPECIFIED IN THE CONTRACT DOCUMENTS WILL BE SUBMITTED BY THE <br />GENERAL CONTRACTOR TO THE ARCHITECT PRIOR TO FABRICATION IN ORDER TO VERIFY GENERAL CONFORMANCE WITH THE CONTRACT DOCUMENTS. SHOP DRAWINGS AND <br />SUBMITTALS MUST BEAR A REVIEW STAMP FROM THE GENERAL CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT. SHOP DRAWING REVIEW AND APPROVAL WILL <br />NOT RELIEVE ANY PARTY FROM MAINTAINING COMPLIANCE WITH THE CONTRACT DOCUMENTS. <br />K <br />DETAILS MARKED AS'TYP' OR'TYPICAL' WILL APPLY IN ALL CASES UNLESS OTHERWISE NOTED. <br />L <br />ALL DIMENSIONS ARE TAKEN FROM GRID LINES OR FINISHED FACE OF WALL / PARTITION UNLESS OTHERWISE NOTED. <br />ABBREVIATIONS <br />SYMBOL/ <br />ACCRONYM <br />DESCRIPTION <br /># <br />POUND OR NUMBER <br />% <br />PERCENT <br />+/- <br />PLUS/MINUS <br />NONE OR NOT APPLICABLE <br />@ <br />AT <br />0 <br />DIAMETER OR ROUND <br />L <br />ANGLE <br />AB <br />ANCHOR BOLT <br />ABS <br />ABSOLUTE <br />AC <br />ASPHALTIC CONCRETE <br />ACC <br />ACCESSIBLE WORK STATION <br />ACOUS <br />ACOUSTICAL <br />ADJ <br />ADJACENT <br />AFF <br />ABOVE FINISHED FLOOR <br />AL <br />ALUMINUM <br />ANSI <br />AMERICAN NATIONAL STANDARDS <br />INSTITUTE <br />ARCH <br />ARCHITECTURAL <br />BD <br />BOARD <br />BLDG <br />BUILDING <br />BLK <br />BLOCK <br />BLKG <br />BLOCKING <br />BTWN <br />BETWEEN <br />C <br />CHANNEL <br />CER <br />CERAMIC <br />CF <br />CUBIC FEET <br />CFCI <br />CONTRACTOR FURNISHED, <br />CONSTRACTOR INSTALLED <br />CFOI <br />CONTRACTOR FURNISHED, OWNER <br />INSTALLED <br />CJ <br />CONTROL JOINT <br />CL <br />CENTERLINE <br />CLG <br />CEILING <br />CLR <br />CLEAR <br />CMU <br />CONTRETE MASONRY UNIT <br />CONC <br />CONTRETE <br />CONSTR <br />CONSTRUCTION <br />CONT <br />CONTINUOUS <br />CORR <br />CORRIDOR <br />CT <br />CLEAR TEMPERED <br />CTC <br />CENTER TO CENTER <br />CTSK <br />COUNTERSUNK <br />DBL <br />DOUBLE <br />DEC <br />DEAD END CORRIDOR <br />DEL <br />DELETE <br />DIET <br />DETAIL <br />DF <br />DRINKING FOUNTAIN <br />DIA <br />DIAMETER <br />DIM <br />DIMENSION <br />DL <br />DOOR LOUVER <br />DN <br />DOWN <br />DR <br />DOOR <br />DS <br />DOWNSPOUT <br />DWG <br />DRAWING <br />EA <br />EACH <br />EJ <br />EXPANSION JOINT <br />ELEC <br />ELECTRICAL <br />ELEV <br />ELEVATION <br />EMT <br />ELECTRICAL METAL TUBING <br />ENCL <br />ENCLOSURE <br />ENGR <br />ENGINEER <br />EOS <br />EDGE OF SLAB <br />EQ <br />EQUAL <br />EQPT <br />EQUIPMENT <br />EW <br />EACH WAY <br />EX <br />EXISTING <br />EXP <br />EXPANSION <br />EXT <br />EXTERIOR <br />FA <br />FIRE ALARM <br />FD <br />FLOOR DRAIN <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />FDN <br />FOUNDATION <br />FE <br />FIRE EXTINGUISHER <br />FEC <br />FIRE EXTINGUISHER W/ CABINET <br />FF <br />FINISHED FLOOR <br />FG <br />FINISHED GRADE <br />FH <br />FIRE HYDRANT <br />FHC <br />FIRE HOSE W/ CABINET <br />FL <br />FLOOR <br />FO <br />FACE OF <br />FOC <br />FACE OF CONCRETE <br />FOF <br />FACE OF FINISH <br />FOM <br />FACE OF MASONRY <br />FOS <br />FACE OF STUD <br />FRB <br />FIRE RETARDANT BARRIER <br />FS <br />FINISHED SURFACE <br />FT <br />FOOT OR FEET <br />FTG <br />FOOTING <br />ABBREVIATIONS <br />SYMBOL/ <br />ACCRONYM <br />DESCRIPTION <br />GA <br />GAUGE <br />GALV <br />GALVENIZED <br />GB <br />GYPSUM BOARD <br />GFRC <br />GLASS FIBER REINFORCED CONCRETE <br />GYP <br />GYPSUM <br />HB <br />HOSE BIB <br />HDWE <br />HARDWARE <br />HM <br />HOLLOW METAL <br />HOR <br />HORIZONTAL <br />HR <br />HOUR <br />HVAC <br />HEATING VENTILATION AIR CONDITIONING <br />ID <br />INSIDE DIAMETER <br />IG <br />FROSTED FILM OVER CLEAR INSULATED <br />TEMPERED GLAZING <br />IN <br />INCH OR INCHES <br />INT <br />INTERIOR <br />INV <br />INVERT <br />JAN <br />JANITOR CLOSET <br />JBOX <br />JUNCTION BOX <br />LAV <br />LAVATORY <br />LB(S) <br />POUND(S) <br />MAX <br />MAXIMUM <br />MB <br />MACHINE BOLT <br />MDF <br />MEDIUM DENSITY FIBERBOARD <br />MFR <br />MANUFACTURER <br />MH <br />MANHOLE <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MTL <br />METAL <br />NIC <br />NOT IN CONTRACT <br />NO <br />NUMBER <br />NR <br />NOT RATED <br />NTS <br />NOT TO SCALE <br />O/ <br />OVER <br />OA <br />OVERALL <br />OC <br />ON CENTER <br />OD <br />OUSIDE DIAMETER <br />OFCI <br />OWNER FURNISHED, CONTRACTOR <br />INSTALLED <br />OFOI <br />OWNER FURNISHED, OWNER INSTALLED <br />OH <br />OPPOSITE HAND <br />OTO <br />OUT TO OUT <br />PA <br />PUBLIC ACCESS <br />PE <br />PAD ELEVATION <br />PERP <br />PERPENDICULAR <br />PH <br />PANIC HARDWARE <br />PL <br />PLATE <br />PLAM <br />PLASTIC LAMINATE <br />PLUMB <br />PLUMBING <br />PLYWD <br />PLYWOOD <br />PM <br />PARTTION MOUNTED <br />POC <br />POINT OF CONNECTION <br />PR <br />PAIR <br />PREP <br />PREPARE <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />PT <br />PAINTED <br />PTN <br />PARTITION <br />PVC <br />POLYVINYL CHLORIDE <br />R <br />RISER, RADIUS <br />RD <br />ROOF DRAIN <br />REC <br />RECESSED <br />REF <br />REFERENCE <br />REQ <br />REQUIRED <br />RM <br />ROOM <br />RO <br />ROUGH OPENING <br />RWL <br />RAIN WATER LEADER <br />SCHED <br />SCHEDULE <br />SCWD <br />SOLID CORE WOOD DOOR <br />SECT <br />SECTION <br />SF <br />SQUARE FEET <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />SM <br />SURFACE MOUNTED <br />SMS <br />SHEET METAL SCREW <br />SOV <br />SHUT OFF VALVE <br />SPEC <br />SPECIFICATION <br />SST <br />STAINLESS STEEL <br />STD <br />STANDARD <br />STL <br />STEEL <br />STRUCT <br />STRUCTURAL <br />T&B <br />TOP AND BOTTOM <br />TDE <br />TRAVEL DISTANCE TO EXIT <br />TDSC <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TEMP <br />TEMPORARY <br />TO <br />TOP OF <br />ABBREVIATIONS <br />SYMBOL/ <br />ACCRONYM <br />DESCRIPTION <br />TOC <br />TOP OF CURB <br />TOD <br />TOP OF DRAIN <br />TOP <br />TOP OF PARAPET <br />TOPL <br />TOP OF PLATE <br />TOR <br />TOP OF RIDGE <br />TOS <br />TOP OF SLAB <br />TOW <br />TOP OF WALL <br />TST <br />TOP OF STEEL <br />TV <br />TELEVISION <br />TYP <br />TYPICAL <br />UC <br />UNERCUT <br />UNO <br />UNLESS NOTED OTHERWISE <br />UON <br />UNLESS OTHERWISE NOTED <br />VCT <br />VINYL COMPOSITE TILE <br />VERT <br />VERTIAL <br />VWE <br />VERIFY WITH EQUIPMENT <br />VWF <br />VERIFY WITH FIXTURE <br />W <br />WIDE FLANGE <br />W/ <br />WITH <br />W/O <br />WITHOUT <br />WD <br />WOOD <br />WH <br />WATER HEATER <br />WI <br />WOOD WORK INSTITUTE <br />WIN <br />WINDOW <br />WP <br />WATERPROOF <br />WS <br />WOOD SCREW <br />WT <br />WEIGHT <br />WWF <br />WELDED WIRE FABRIC <br />x <br />BY <br />YD <br />YARD <br />studl + <br />■ <br />California I Florida I Nevada <br />2211 E. 7TH Avenue, Tampa, Florida 33605 <br />P:239.357.4983 AA26002373 <br />Peninsula Engineering, INC. <br />MEP&FP <br />516 Alden Road Orlando, FL 32803 <br />P: 407.246.1688 <br />F: 407.246.1664 <br />LBA INTERIORS <br />INTERIOR DESIGNER <br />5650 DTC PARKWAY, SUITE 100 <br />ENGLEWOOD, CO. 80111 <br />P:303.773.0436 <br />F:303.773.0053 <br />REVISIONS: <br />1 07/29/2016 JAHCA COMMENTS <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />AR97653 <br />LP <br />\0. <br />P J T ITLE: <br />Z RHILLS HEALTH & <br />REHAB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />SYMBOLS, ABBREVIATIONS, <br />& GENERAL NOTES <br />GOmOl <br />© 2015 Studio+ <br />C:\Users\LevvN\Documents\2016.04.20 - CENTRAL - ADVENTIST - ZEPHYRHILLS HEALTH AND REHAB CENTER LevvN.rvt <br />