Laserfiche WebLink
KEY NOTES <br />GENERAL NOTES <br />BUILDING INFORMATION <br />CONSTRUCTION TYPE V-A <br />AUTOMATIC SPRINKLERS YES <br />NUMBER OF STORIES 1 <br />1ST FLOOR GROSS AREA +/- 54,670 SF <br />EXISTING USE GROUP (FBC CH 3) INSTITUTIONAL (1-2) <br />PROPOSED USE GROUP (FBC CH 3) INSTITUTIONAL (1-2). NO CHANGE. <br />SCOPE OF WORK 5,626 SF <br />EXISTING FUNCTION OF SPACE (FBC TABLE 1004.1.2) INSTITUTIONAL (1-2) (ASSISTED LIVING FACILITY) <br />PROPOSED FUNCTION OF SPACE (FBC TABLE 1004.1.2) INSTITUTIONAL (1-2) (SKILLED NURSING) <br />OCCUPANCY CALCULATION (FBC TABLE 1004.1.1) REFER TO OCCUPANCY CALCULATIONS ON LS1.2 <br />APPLICABLE CODES - FLORIDA <br />5TH EDITION 2014 FLORIDA BUILDING CODE <br />5TH EDITION 2014 FLORIDA EXISTING BUILDING CODE <br />FBC TEST PROTOCOLS FOR HIGH VELOCITY HURRICANE ZONES 2014 <br />5TH EDITION 2014 FLORIDA PLUMBING CODE <br />5TH EDITION 2014 FLORIDA MECHANICAL CODE <br />FBC FUEL GAS CODE 2014 <br />5TH EDITION 2014 FLORIDA ENERGY CONSERVATION CODE <br />FGI GUIDELINES FOR HELATH CARE CONSTRUCTION <br />5TH EDITION 2014 FLORIDA ACCESSIBILITY CODE <br />FLORIDA FIRE PREVENTION CODE, FIFTH EDITION (CHAPTER 19 EXISTING HEALTHCARE OCCUPANCIES), <br />2014 <br />NFPA-101, LIFE SAFETY CODE 2012 EDITION <br />NFPA-1, UNIFORM FIRE CODE 2012 EDITION <br />FLORIDA STATE FIRE MARSHAL'S RULE 69A3.012 F.A.C. (8/8/2005) <br />NFPA-10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2010 <br />NFPA-13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2010 <br />NFPA-70, NATIONAL ELECTRICAL CODE 2011 <br />NFPA-72, NATIONAL FIRE ALARM CODE 2010 <br />NFPA-80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS 2010 <br />NFPA-99, STANDARD FOR HEALTH CARE FACILITIES 2012 <br />NFPA-221, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS 2012 <br />NFPA-251, STANDARD METHODS OF TESTS OF FIRE ENDURANCE OF BUILDING CONSTRUCTION AND <br />MATERIALS 2006 <br />NFPA-253, STANDARD METHOD OF TEST FOR CRITICAL FLUX OF FLOOR COVERING SYSTEMS USING A <br />RADIANT HEAT ENERGY SOURCE 2011 <br />NFPA-255, STANDARD METHOD OF TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS <br />2006 <br />NFPA-703, STANDARD FOR FIRE RETARDANT IMPREGNATED WOOD AND FIRE RETARDANT COATINGS FOR <br />BUILDING MATERIALS 2012 <br />EXITING TABULATIONS (SKILLED NURSING) <br />COMPART. <br />COMPART. <br />OCCUP. <br />SO FT / <br /># OF <br />INCHES/ <br />INCHES/ <br />PROV. <br />AREA <br />TYPE <br />OCCUP. <br />OCCUP. <br />OCCUP. <br />REQ'D. <br />STR. <br />STR. <br />10,300 SF <br />SLEEP <br />120 <br />86 <br />1 A-1 <br />.2 <br />26.6 <br />90 <br />11,140 SF <br />ANCILLARY <br />240 <br />47 <br />1A-2 <br />2,070 SF <br />ANCILLARY <br />240 <br />9 <br />.2 <br />1.8 <br />112 <br />FIRE <br />23,510 SF <br />142 <br />28.4 <br />202 <br />SECT 1 A <br />4,780 SF <br />SLEEP <br />120 <br />40 <br />1 B-1 <br />.2 <br />12.2 <br />180 <br />4,940 SF <br />ANCILLARY <br />240 <br />21 <br /><, FIRE <br />9,720 SF <br />61 <br />2 2 <br />180 <br />,SECT 1 B <br />4,220 SF <br />SLEEP <br />120 <br />36 <br />1 C- i <br />.2 <br />8.2 <br />90 <br />1,120 SF <br />ANCILLARY <br />240 <br />5 <br />FIRE <br />5,340 SF v14 <br />41 <br />8.2 <br />90 <br />„u�^ ECT 1 <br />c . <br />a <br />4,850 SF <br />SLEEP <br />120 <br />41 <br />1D-1 <br />.2 <br />13.2 <br />45 <br />5,800 SF <br />ANCILLARY <br />240 <br />25 <br />FIRE <br />10,640 SF <br />66 <br />132 <br />45 <br />SECT 1D <br />1 E-1 <br />5,460 SF <br />SLEEP <br />120 <br />46 <br />.2 <br />9.2 <br />45 <br />(NEW <br />WORK <br />FIRE <br />5,460 SF <br />46 <br />9.2 <br />45 <br />SECT 1 E <br />54,670SF 356 72.2 562 <br />COMPARTMENTATION DIAGRAM 1 1 <br />� KEY PLAN (N.T.S.): <br />PROJ <br />AREA <br />I <br />3/64" = V-0" <br />tudio+ <br />California I Florida I Nevada <br />2211 E. 7TH Avenue, Tampa, Florida 33605 <br />P:239.357.4983 AA26002373 <br />Peninsula Engineering, INC. <br />MEP&FP <br />2016 Alden Road Orlando, FL 32803 <br />P: 407.246.1688 <br />F: 407.246.1664 <br />ARCHISPEC, INC <br />ARCHITECTURAL SPECIFICATIONS <br />653 Mallory Hill Drive Lady Lake, FL 32162 <br />P: 352.430.0987 <br />REVISIONS: <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARE AIA <br />AR97653 <br />1 q , I � <br />0 <br />PRO, T TLE: <br />ZEPHY HILLS HEALTH <br />REHAB CENTER <br />SKILLED NURSING -10 BED <br />CONVERSION <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL. 33540 <br />PROJECT NUMBER: <br />FLTSP15008 <br />SHEET TITLE: <br />BUILDING <br />COMPARTME TATIO <br />C:\Users\Danr\Desktop\2015.12.15 - CENTRAL - ADVENTIST - ZEPHYRHILLS HEALTH AND REHAB CENTER_Danr.rvt <br />PROJECT NORTH TRUE NORTH <br />G002 <br />© 2015 Studio+ <br />