Laserfiche WebLink
V <br />Z <br />O <br />I I I I I I <br />I I I I I I <br />FAN TEST REPORT I I VELGRID REPORT I I Sonic Drive —In TAB Procedure 1 <br />I I I I <br />Oki <br />Project: ZEPHYRHILLS, FLORIDA — 005080 1 1 Project: ZEPHYRHILLS, FLORIDA — 005080 <br />Fan # <br />Location <br />Service <br />Manufacturer <br />Model # <br />Serial # <br />Motor Make/Frame <br />H.P./R.P.M. <br />Volts/Phase/Hertz <br />F.L. Amps/Service Factor <br />Fan Sheave Make <br />Fan Sheave Diameter/Bore <br />Motor Sheave Make <br />Motor Sheave Diameter/Bore <br />Motor Sheave Model # <br />Operating Diameter <br />Number of Belts/Make/Size <br />Centerline Distance <br />TEST DATA <br />DESIGN <br />ACTUAL <br />DESIGN <br />ACTUAL <br />Total C.F.M. <br />Fan R.P.M. <br />Total Static Pressure <br />Discharge S.P./Suction S.P. <br />Voltage <br />Amperage <br />*117VI:1:431 <br />Technician Name: <br />Test Date: <br />L--------------------------------------------- J <br />------------------------------------------- <br />RECTANGULAR DUCT TRAVERSE REPORT <br />Project: ZEPHYRHILLS, FLORIDA — 005080 <br />System: <br />Width: <br />Duct Area <br />Design <br />Actual <br />Height: <br />Isq. Ft. <br />Vel. <br />C.F.M. <br />Vel. <br />C.F.M. <br />Position 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 14 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />Total F.P.M. # of Readings Average Velocity Duct Area C.F.M. <br />Remarks: <br />TT <br />D <br />w <br />z <br />U <br />System: <br />Width: <br />Filter Area <br />Design <br />Actual <br />Height: <br />Sq. Ft <br />Vel. <br />C.F.M. <br />Vel. <br />C.F.M. <br />Position 1 1 1 2 1 3 1 4 1 5 1 6 1 7 <br />Total F.P.M. # of Readings Average Velocity Duct Area C.F.M. <br />Remarks: <br />Technician Name: <br />Test Date: <br />L------------------------------------- <br />------------------------------------ <br />ROUND DUCT TRAVERSE REPORT <br />Project: ZEPHYRHILLS, FLORIDA — 005080 <br />System: <br />Size <br />Duct Area <br />Design <br />Actual <br />q. Ft <br />Vel. <br />C.F.M. <br />Vela <br />C.F.M. <br />Position <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />1 9 <br />10 <br />11 <br />12 <br />13 <br />Total F.P.M. # of Readings Average Velocity Duct Area C.F.M. <br />Remarks: <br />The entire system must by fully operational: Outside doors closed, RTUs running, outside <br />air hoods installed, filters installed, balance dampers fully open, all outlets installed <br />(including the 3—way diffusers), exhaust fans running, proper EF to grease duct <br />transistors installed, grease filters installed, and supply fans running. <br />I 1. Roof Top Units <br />1 1.1 Record all units data, motor data, and design data on the Roof Top Report <br />sheets. <br />1 1.2 Set the outside air volume close to design. <br />1.3 Place the units in cooling mode if the season allows. <br />1.4 Read all of the outlets using a calibrated flowhood. Record as preliminary on <br />the Outlet Test Report sheets. <br />1.5 Proportion the outlets to the design flow rates. <br />1.6 Adjust the RTUs to deliver design air flow. <br />1.7 Read all of the outlets. Make adjustments as necessary. Record final <br />readings on the Outlet Test Report sheets. <br />1.8 Record all actual performance data on the Roof Top Test Report sheets. <br />2. Exhaust Fans (Rest Rooms) <br />2.1 Record all fan data, motor data, and design data on the Fan Test Report <br />sheets. <br />2.2 Read the exhaust grille. <br />2.3 Record the exhaust inlet volume on the Fan Test Report sheet. <br />3. Kitchen Hoods (Strata Vent) <br />3.01 Record all fan data, motor data, and design data on the Fan Test Report <br />sheets. <br />1 3.02 Traverse the supply fan duct work. <br />1 3.03 Proportion the supply duct runs to design volumes by method of traverse. <br />1 3.04 Adjust the supply fan to design output air flow. <br />3.05 Reread all supply duct runs. Make adjustments if necessary. Record final <br />total Fan output on the Fan Test Report sheet. <br />3.06 Record each hood final supply air flow on the Hood Test Report sheet. <br />3.07 Measure each hood exhaust air flow using a Shortridge Vel—Grid or a <br />rotating vane anemometer. Multiply the average filter inlet velocity by the <br />filter bank area. Derive the exhaust air flow. <br />3.08 Adjust the exhaust fans to deliver the design exhaust flow rates. Record the <br />Final exhaust flow rates on the Fan Test Report sheets. <br />3.09 Record each hood exhaust flow on the Hood Test Report sheet. <br />3.10 Use smoke candles to verify proper smoke extraction on each hood. Smoke <br />traveling outside the hood area is not acceptable. <br />�I <br />w1 <br />=I <br />�I <br />01 <br />Oki <br />I <br />NOTE: <br />The Test Report sheets shall be cut from the drawings and duplicated as <br />needed. All data fields must be filled in. All information and data must <br />be typed or in legible printed handwriting. The final report shall be four <br />(4) copies, certified, and bound. Reduced size drawings must be included <br />in the final TAB report. <br />L-------------------- <br />----------------- J <br />W1 <br />j Tj <br />=1 <br />I WI I <br />U I <br />I I <br />Ok <br />�UI <br />I oo <br />I Technician Name: <br />I I Technician Name: <br />Test Date: <br />I I <br />I I Test Date: <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — <br />I I <br />— — — — — — — — — — — — — — — — — — L — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - J <br />�j <br />0 <br />Z <br />6A <br />0 <br />w <br />V) <br />t <br />N <br />0 <br />0 <br />0 <br />a <br />a <br />WV_ <br />LU <br />ZW <br />_E <br />CAN 1- <br />w <br />Z <br />Woe <br />fa^ <br />?Q~ <br />Z J= <br />LLT <br />LU Z <br />0..n=> <br />Co <br />W <br />ZZO <br />001044 <br />cc <br />I�VcyC7 <br />�A <br />0 awe <br />pro <br />a LIN <br />N0Z <br />'WU <br />® Z N <br />0 LIS > N � Z O <br />0 <br />(B7 } <br />0 <br />V Z 4 <br />Mu <br />eoa o N <br />lul o o w <br />0 0 Q + 22 in <br />am wvoi< <br />44 0 V moz <br />M i <br />o" <br />® zWo <br />® wow <br />C%Q aw�s <br />9 40 z <br />rtUl coo~o <br />0-3 0 <br />P gzrU- <br />�=7 <br />LJ <br />WUJ <br />~~U <br />o <br />V <br />Z <br />Z <br />o <br />a <br />LU cA <br />�1Y_Uu� <br />~oZ <br />I— <br />LL <br />Q <br />LO <br />0 <br />O <br />N <br />A IL <br />Qn <br />H <br />SHEET <br />M4 <br />DING: <br />005080-M4 <br />