NJt in <br />GENERAL: <br />THE ADDENDUM ITEMS LISTED ON THIS PAGE MODIFY, <br />CLARIFY, AND SUPERSEDE THE ORIGINAL CONSTRUCTION <br />DOCUMENTS AT THE TIME THE CONSTRUCTION DOCUMENTS <br />WERE ISSUED. <br />ADDENDA ITEM 01: <br />THIS ITEM MODIFIES THE SWING: BIDE OF THE VESTIBULE <br />DOORS (101A t 10115). THIS CHANGE SUPERSEDES THE DOOR <br />SWINGS AS SHOWN ON THE FLOOR PLAN (A-1.03) BY <br />REVERSING THE SIDE OF JAMB ON WHICH THE DOOR 18 <br />HINGED. REFERENCE PARTIAL FLOOR PLAN (AD-1.01) FOR <br />REVISED HINGE LOCATIONS. <br />DDENDA IT =M 02: <br />THIS ITEM INVOLVES SUBSTITUTING A "DURO-LAST" FLEXIBLE <br />SHEET ROOFING SYSTEM FOR THE BUILT-UP MODIFIED <br />BITUMEN ROOFINGS AS SPECIFIED IN SECTION 01525, ON <br />SHEET SP-1. THIS ALSO INVOLVES REVISING THE RIGID ROOF <br />INSULATION AS SPECIFIED IN SECTION 01212, ON SHEET SPI. <br />REFERENCE REVISED SECTION 01212 (BELOW) FOR THE RIGID <br />ROOF INSULATION SPECIFICATION, AND SUBSTITUTED SECTION <br />01533 (BELOW) FOR THE FLEXIBLE SHEET ROOFING SYSTEM <br />SPECIFICATION. MODIFY ROOF CONSTRUCTION FOR ANY <br />DETAILS AT ROOF PENETRATIONS, JOINTS, EDGE, FLASHING, <br />AND DRAIN CONDITIONS PER MANUFACTURERS STANDARD <br />DETAILS. <br />07212 RIGID ROOF INSULATION <br />1. RIGID ROOF INSULATION SHALL BE POLYISCCYANURATE BOARD, 3' THICK, WITH AN <br />MINIMUM R-VALUE OF 20.0. INSULATION SHALL BE WITH MECHANICAL FASTENERS IN <br />CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS AND FACTORY MUTUAL 1-60 <br />REQUIREMENTS. <br />2. TAPERED INSULATION FOR CRICKETS SHALL BE POLYISOCYANURATE, MINIMUM 3/4' <br />THICK, WITH 1/2' PER 12' SLOPE, INSTALLED AS INDICATED ON THE DRAWINGS. <br />3. SUBMIT PRODUCT DATA ON INSULATION BOARDS. <br />07533 FLEXIBLE SHEET ROOFING SYSTEM <br />1. FLEXIBLE SHEET ROOFING SYSTEM SHALL BE IN ACCORDANCE WITH DURO-LAST <br />SPECIFICATION FOR CO -POLYMER ALLOY SINGLE PLY MEMBRANE, OVER RIGID <br />INSULATION. <br />2. MATERIAL SHALL BE DURC-LAST 40 MIL SINGLE PLY ROOFING MEMBRANE. <br />a APPLICATION SHALL BE IN ACCORDANCE WITH APPROVED MANUFACTURER'S <br />SPECIFICATIONS. <br />4, ALL ROOF PENETRATIONS SHALL BE IN ACCORDANCE WITH APPROVED MANUFACTURER'S <br />STANDARD DETAILS. <br />5. SUBMIT PRODUCT DATA. <br />S. ROOFING SYSTEM SHALL HAVE MINIMUM FIFTEEN (15) YEAR GUARANTEE ON THE <br />MATERIAL AND WORKMANSHIP, <br />7. DURO-LAST ROOFING, INC. 1-800-248-0280. 525 MORLEY DRIVE, SAGINAW, MI <br />48601 FAX # 1-800-422-9331 <br />ADDENDA ITEM 13: <br />THIS ITEM SUPERSEDES AND CLARIFIES THE POWER AND <br />DATA REQUIREMENTS AS SHOWN ON SHEET E-4 FOR THE POS <br />SYSTEM INSTALLATION. <br />ADDENDA ITEM 104: <br />THIS ITEM SUPERSEDES SPECIFICATION SECTION 08410 AND <br />SPECIFICATION SECTION 08110 (BUT DOES NOT INCLUDE <br />CHANGES TO HARDWARE SETS 2-6) AS SHOWN ON SHEET <br />SP-4. REFERENCE REVISED SECTION 08410 (BELOW) FOR <br />THE ALUMINUM ENTRANCE DOOR SPECIFICATION, AND <br />REVISED SECTION 08110 (BELOW) FINISH HARDWARE. <br />REFERENCE SPECIFICATION SECTION 08110 ON SP-4 FOR <br />HARDWARE SETS 2-6 ONLY. REFERENCE ELEVATION AD-1.04 <br />FOR ADDITIONAL INFORMATION ON LINEAR RECEIVER <br />INSTALLATION. <br />08410 ALUMINUM ENTRANCE DOORS <br />1. ALUMINUM FRAMES SHALL BE SERIES 450 CENTER GLAZED 1-3/4' X 4-1/2' PROFILE, <br />EQUAL TO ENTRANCE FRAMING AS MANUFACTURED BY UNITED STATES ALUMINUM CORP. <br />OR KAWNEER CORP. FINISH TO BE ANODIZED DARK BRONZE, <br />2. ALUMINUM ENTRANCE DOORS TO BE EQUAL TO UNITED STATES ALUMINUM SERIES 400 <br />MEDIUM STILE DOOR, WITH 3-3/16' TOP, 3-1/2' SIDE RAILS, AND OPTIONAL 10' <br />BOTTOM RAIL. GLAZING TO BE 1/4' THICK TEMPERED CLEAR GLASS, ALUMINUM <br />FINISH TO BE ANODIZED BRONZE. DOORS TO BE OFFSET HUNG SINGLE -ACTING AS <br />INDICATED ON THE DRAWINGS. KAWNEER DOORS ARE AN ACCEPTABLE ALTERNATE, <br />WEARTHER STRIP WITH WOOL PILE. <br />3. DOOR AND FRAME HARDWARE FURNISHED AND INSTALLED BY THIS SECTION IS <br />SPECIFIED IN SECTION 08700, <br />08710 FINISH HARDWARE <br />1. CONTRACTOR SHALL FURNISH AND INSTALL FINISH HARDWARE AS SCHEDULED IN THIS <br />SECTION. SUPPLY TEMPLATES TO DOOR AND FRAME MANUFACTURERS TO ENABLE PROPER <br />AND ACCURATE CUT -CUTS FOR HARDWARE. <br />2. ALL LOCKSETS AND CYLINDERS SHALL BE KEYED ALIKE WITH REMOVABLE CORES, IN <br />ADDITION, THEY SHALL BE MASTERKEYED TO A SCHLAGE MASTERKEY SYSTEM. <br />3. SUBMIT FULL AND COMPLETE HARDWARE SCHEDULE FOR ARCHITECT'S APPROVAL. <br />4. HARDWARE SCHEDULE, <br />HARDWARE SET #1 <br />1-SGL DR ENTRANCE, #101B EXTERIOR FM VEST. 101 1 - 3'-O'x71-O'x1-3/4' <br />REFER TO PLANS FOR LOCATION AND HANDING <br />1 EACH PULL HANDLE TYPE 'C' ASTRAL U.S. ALUMINUM <br />1 EACH DEADBOLT MS1852S-55-313 ADAMS RITE <br />1 EACH MORTISED CYLINDER 4036 313 SCHLAGE 'C' KEYWAY ADAMS RITE <br />1 EACH MORTISED THUMBTURN 4066 313 ADAMS RITE <br />1 EACH OFFSET PIVOTS P553U SET ABC <br />1 EACH RIM PANIC 8802EL-36-12 ADAMS RITE <br />1 EACH RIM CYLINDER 8736 313 SCHLAGE 'C' KEYWAY ADAMS RITE <br />i EACH 12V TRANSFORMER 4606-12 ADAMS RITE <br />1 EACH CLOSER W/ BC/DEL 650 SERIES DORMA <br />1 EACH CLOSER DROP PLATE DORMA <br />1 EACH THRESHOLD 1/2'x4' ADA COMPLIANT U.S. ALUMINUM <br />FOLLOWING HARDWARE FURNISHED BY SONIC INDUSTRIES FOR HARDWARE SET #11 <br />i EACH DIGITAL RECEIVER DXR-702 LINEAR <br />10 EACH TRANSMITTER DXT-23 LINEAR <br />HARDWARE SET #1A (HARDWARE SET #1A FOR DOOR 101A INSTALLED ON SIDE) <br />(WITH THE MOST STALLS - COORDINATE WITH OWNER'S) <br />(REPRESENTATIVE) <br />1 SGL DR EXIT, #101A EXTERIOR FM VEST, 101 1 - 3' -O' x7' -0' x1-3/4' <br />REFER TO PLANS FOR LOCATION AND HANDING <br />1 EACH DEADBOLT NS1852S-56-313 ADAMS RITE <br />1 EACH MORTISED THUMBTURN 4066 313 ADAMS RITE <br />1 EACH OFFSET PIVOTS P553U SET ABC <br />i EACH RIM PANIC 8802-36 ADAMS RITE <br />1 EACH CLOSER W/ BC/DEL 650 SERIES DORMA <br />1 EACH CLOSER DROP PLATE DORMA <br />1 EACH THRESHOLD 1/2'x4' ADA COMPLIANT U,S. ALUMINUM <br />HARDWARE SET #iB (HARDWARE SET #1B ONLY USED IN BUILDING TYPE 02) <br />CW/HOP-THRU DOOR) <br />1 SGL DR #103 EXTERIOR FM DT-WINDOW 103 1 - 2'-6'x7'-O'xI-3/4' LHR CRH) <br />REFER TO PLANS FOR LOCATION AND HANDING <br />1 EACH PULL HANDLE TYPE 'C' ASTRAL U.S, ALUMINUM <br />1 EACH DEADBOLT MS1852S-55-313 ADAMS RITE <br />i EACH MORTISED CYLINDER 4036 313 SCHLAGE 'C' KEYWAY ADAMS RITE <br />1 EACH MORTISED THUMBTURN 4066 313 ADAMS RITE <br />1 EACH OFFSET PIVOTS P553U SET ABC <br />1 EACH CLOSER W/ BC/DEL 650 SERIES DORMA <br />d 1 EACH CLOSER DROP PLATE DORMA <br />1 EACH THRESHOLD 1/2'x4' ADA COMPLIANT U.S, ALUMINUM <br />Q <br />ADDENDA ITEM "I: <br />COUNTER <br />1/411 O 11-011 <br />ADDENDA ITEM 03: <br />OZ POS PLAN <br />2" PVC <br />JUNCTION <br />BOX <br />1" PVC <br />III PVC <br />LINE OF CEILING <br />i I !141191ULuRkj <br />Ego <br />ADDENDA ITEM 04: <br />52 <br />— ..J <br />102 <br />GAR HOF <br />COUNTER <br />101 <br />VEST. <br />LOW VOLTAGE WIRE AND <br />TRANSFORMER 12VDC <br />LINEAR DXR-102 <br />RECEIVER <br />ADAMS RITE <br />8802EL-36-12 <br />0 4 r=LEVATION <br />1/4 <br />11 O 11-011 <br />ADDENDU1l #3 1 OTE6: <br />*1. INSTALL 12"Hx14"Wx4"D J-BOX WITH <br />*5. <br />PROVIDE POWER TO COMPUTER / <br />ACCESSIBLE COVER (1) 2" CONDUIT <br />REGISTERS - ISOLATED GROUND TYPE <br />FED FROM MAX. 12 STALLS (le: 30 <br />ORANGE RECEPTACLE. CIRCUIT SHALL <br />STALLS . (3) 2" CONDUITS) FOR DATA <br />HAVE ISOLATED GROUND WIRE. <br />CABLE. SEE SHEET E-I FOR POWER <br />«�,. <br />PROVIDE 6X6 J-BOX IN WALL W/ 11/2" <br />PLAN TO CANOPIES. <br />CONDUIT UNDER SLAB TO 12x14 J-BOX. <br />(1) 3/4" CONDUIT FED FROM SPEAKER <br />*1. <br />PROVIDE POWER TO MONITORS - <br />PEDESTAL AT DRIVE THRU. SEE SHEET <br />ISOLATED GROUND TYPE ORANGE <br />E-1 FOR POWER PLAN TO DRIVE THRU <br />RECEPTACLES MOUNTED IN FACE OF <br />MENU BOARD. <br />CEILING PANELS. CIRCUIT SHALL HAVE <br />ISOLATED GROUND WIRE. <br />STUB UP ABOVE CEILINGS (2) 2" <br />CONDUIT AND (1) 3/4" CONDUIT FROM <br />«8. <br />NOT USED. <br />J-BOX. <br />*S. <br />PROVIDE 6x6 J-BOX FOR DATA. STUB <br />I" CONDUIT ABOVE CEILING. MOUNT <br />(1) P CONDUIT FED FROM PATIO MENUS. <br />BOX 24" A.FF. <br />INSTALL J-BOX (2x4) AT 60" A.F.F. FOR <br />CONTROLLER AND STUB OUT 3/4" <br />CONDUIT ABOVE CEILING. CONTROLLER <br />$2, i t ll fA CC '- <br />ISOLATED GROUND TYPE ORANGE <br />RECEPTACLES. CIRCUIT SHALL HAVE <br />ISOLATED GROUND WIRE - PLACE <br />OUTLET AT 8'6" A.F.F. <br />*3. PROVIDE POWER FOR BASE STATIONS - <br />ISOLATED GROUND TYPE ORANGE <br />RECEPTACLES. CIRCUIT SHALL NAVE <br />ISOLATED GROUND WIRE - PLACE <br />OUTLET AT 8'6" AF.F. <br />*4. PROVIDE POWER FOR CONTROLLER - <br />ISOLATED GROUND TYPE ORANGE <br />RECEPTACLE. CIRCUIT SHALL HAVE <br />ISOLATED GROUND WIRE - PLACE <br />OUTLET AT 8'6" A.F.F. <br />APEX Site Ready Criteria <br />Inside Store: <br />*10. PROVIDE POWER TO BACK OFFICE <br />COMPUTER - ISOLATED GROUND TYPE <br />ORANGE RECEPTACLE. CIRCUIT SHALL <br />HAVE ISOLATED GROUND WIRE. <br />*11. PROVIDE POWER TO SCANNER, <br />PRINTER, POLE DISPLAY VIA THE <br />J-BOX ABOVE CEILING. E.G. TO <br />PROVIDE S.O. CORD <br />*12. REFER TO SHEET E-3 FOR PANEL <br />SCHEDULE. <br />*13. PROVIDE 2x4 J-BOX IN WALL. PROVIDE <br />1-1/2" CONDUIT STUBBED ABOVE <br />CEILING. <br />*14. PROVIDE ISOLATED GROUND TYPE <br />ORANGE RECEPTACLES MOUNTED 24" <br />AFF. CIRCUIT SHALL HAVE ISOLATED <br />GROUND WIRE. <br />* Ceiling grid finished <br />* Ceiling the in grid where monitors and power is located. <br />* Power in place in waifs and ceiling. <br />* Power <br />* Furniture in place and set. <br />* Sonic authority at store to confirm placement of all equipment. <br />* Telephone service operational. <br />Outside Store: <br />* Underground conduit in place and correct size. <br />* Canopy conduit in place and correct size. <br />* Menu housings attached with flex conduit in place. <br />Please contact APEX Computer Services Inc. at (915) 676-9507 if any questions. <br />W <br />Z <br />Z <br />Ub <br />en <br />W <br />I <br />Z T A <br />® nr I § <br />< I woR <br />® R O <br />CA <br />W <br />0 <br />Z <br />®z <br />� am �rnQ <br />o�z <br />®Z@ <br />o <br />98 <br />Z <br />M� <br />lu4 <br />GROUND LEVEL <br />2" PVC TO STALLS 2" PVC TO STALLS <br />2" PVC TO STALLS 2" PVC TO STALLS <br />I" PVC TO DRIVE-THRU MENU 2" PVC TO PATIO MENUS '" <br />03 Pos j-5ox oiAGR4M � 9 <br />NO SCALE <br />SHEET <br />AD1 <br />SQNIC <br />SONIC <br />DWO., <br />AD 1.DWG <br />JUNE 14 2004 <br />