0 <br />GENERAL STRUCTURAL NOTES <br />3 <br />N <br />1 <br />EI <br />C <br />0 <br />l9 <br />GENERAL: DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND <br />APPLY TO SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB <br />SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, <br />AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR DETAILS NOT SHOWN ON <br />STRUCTURAL DRAWINGS. <br />CONTRACTOR SHALL LOCATE ALL BURIED UTILITIES PRIOR TO EXCAVATION FOR <br />BUILDING FOUNDATIONS. THE STRUCTURAL ENGINEER SHALL BE NOTIFIED OF <br />POTENTIAL CONFLICTS BETWEEN FOUNDATIONS AND BURIED UTILITIES. <br />CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE <br />WITH THE 2014 FLORIDA BUILDING CODE 5TH EDITION. FOLLOW ALL APPLICABLE <br />PROVISIONS FOR ALL PHASES OF CONSTRUCTION. <br />TEMPORARY CONDITIONS: PROVIDE ADEQUATE BRACING, SHORING, AND OTHER <br />TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. THE <br />STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY <br />UNDER FINAL CONFIGURATION ONLY. <br />DESIGN CRITERIA: DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA <br />OF THE 2014 FLORIDA BUILDING CODE. IN ADDITION TO THE DEAD LOADS, THE <br />FOLLOWING LIVE LOADS WERE USED FOR DESIGN: <br />ROOF: 20 PSF LL 30 PSF SDL <br />WIND SPEED 140 MPH PER CHAPTER 26 ASCE 7-10 <br />108 MPH NOMINAL <br />RISK CATEGORY II <br />EXPOSURE C <br />INTERNAL PRESSURE COEFF +/- 0.18 ENCLOSED <br />OPENINGS BELOW 60 FEET SHALL BE PROTECTED FROM WIND BORNE DEBRIS PER <br />FBC 2014 AND ASCE 7-10 REQUIREMENTS. <br />FOUNDATIONS: FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL <br />RECOMMENDATIONS IN THE REPORT PREPARED BY: ARDAMAN & ASSOCIATES, <br />INC PROJECT NUMBER: 15-1702 DATED: SEPTEMBER 2, 2015 WITH AN ALLOWABLE <br />SOIL BEARING PRESSURE FOR SHALLOW FOUNDATIONS OF 2500 PSF. <br />CONTRACTOR SHALL FOLLOW THE RECOMMENDATIONS SPECIFIED IN THE <br />GEOTECHNICAL REPORT INCLUDING, BUT NOT LIMITED TO, SUBGRADE <br />PREPARATIONS AND FOUNDATION INSTALLATION. THE GEOTECHNICAL ENGINEER <br />SHALL EXAMINE THE EXCAVATION TO VERIFY SOIL CONDITIONS AND BEARING <br />PRESSURE PRIOR TO PLACEMENT OF CONCRETE. <br />CONCRETE: REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE <br />FBC AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". <br />CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28-DAY CYLINDER <br />TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS: <br />fc ABS W/C USE <br />3000 PSI 0.58 FOUNDATIONS/SLAB ON GRADE <br />4000 PSI 0.44 ALL USES, U.N.O. <br />CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM <br />C618, TYPE F OR TYPE C, MAY BE USED TO REPLACE UP TO 20% OF THE CEMENT <br />CONTENT, PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA. <br />COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF <br />3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING <br />TO ASTM C33. <br />REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM A615, <br />GRADE 60, FOR DEFORMED BAR AND ASTM A185 FOR SMOOTH WELDED WIRE <br />FABRIC (WWF), UNLESS OTHERWISE NOTED, REINFORCING STEEL TO BE WELDED <br />SHALL CONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY TIED <br />IN PLACE WITH #16 ANNEALED IRON WIRE. <br />REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NOTED <br />OTHERWISE): <br />FOOTINGS 3" BOTTOM AND SIDES, 2" TOP <br />SLABS 3/4" <br />COLUMNS 1-1/2" TO TIES, 2" TOP <br />BEAMS 1-1/2" TO STIRRUPS <br />WALLS 1-1/2" <br />MECHANICAL ANCHORS: MECHANICAL ANCHORS SHALL HAVE THE [CC ES <br />EVALUATION REPORT INDICATING CONFORMANCE WITH CURRENT APPLICABLE <br />ICC ES ACCEPTANCE CRITERIA. MECHANICAL ANCHORS SHALL BE EXPANSION <br />TYPE OR SCREW TYPE AS NOTED ON THE DRAWINGS. <br />IDENTIFY POSITION OF REINFORCING STEEL AND OTHER EMBEDDED ITEMS PRIOR <br />TO DRILLING HOLES FOR ANCHORS. EXERCISE CARE IN CORING OR DRILLING TO <br />AVOID DAMAGING EXISTING REINFORCING OR EMBEDDED ITEMS. NOTIFY THE <br />ENGINEER IF REINFORCING STEEL OR OTHER EMBEDDED ITEMS ARE <br />ENCOUNTERED DURING DRILLING. <br />MASONRY WALLS: MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES <br />SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF fm= 1500. MORTAR SHALL <br />BE TYPE "M" OR "S" AND MEET ASTM C270. GROUT SHALL BE 2000 PSI MINIMUM <br />COMPRESSIVE STRENGTH AND MEET ASTM C476. <br />ALL CELLS CONTAINING VERTICAL BARS, BOND BEAMS, AND ALL CELLS BELOW <br />GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POUR <br />ALLOWED IS 4'-0" UNLESS CLEAN❑OUT OPENING IS PROVIDED AT BOTTOM OF <br />CELLS TO BE FILLED. <br />UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BE PARTIALLY <br />REINFORCED MASONRY WALL CONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT <br />FILLED CELLS. ADD (1) #5 REINFORCING BAR EACH SIDE OF OPENINGS EXCEEDING <br />3 FEET. <br />PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REINFORCING (DUR-O❑WAL OR <br />ENGINEER -APPROVED EQUAL) AT 16" O.C. <br />TIE BEAMS: TIE BEAMS SHALL BE CONCRETE, POURED AFTER THE BLOCK WALLS <br />BELOW ARE IN PLACE. REINFORCING SHALL BE CONTINUOUS THROUGH TIE <br />BEAMS WITH MINIMUM LAP SPLICES OF 48 BAR DIAMETERS AND BENT BARS AT <br />CORNERS. <br />PRECAST CONCRETE LINTELS: UNLESS INDICATED OTHERWISE, ALL LINTELS TO <br />BE "U" TYPE PRECAST CONCRETE UNITS EQUAL TO UNITS MANUFACTURED BY <br />CAST❑CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS <br />REQUIRED) IN ACCORDANCE WITH CAST❑CRETE CORP. "DESIGN MANUAL", LATEST <br />EDITION, FOR THE SPAN AND LOADING CONDITION RELATIVE TO LINTEL LOCATION. <br />LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8-1 B FOR OPENINGS LESS <br />THAN 10 FEET AND 8F16-1 B/1T FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" <br />MINIMUM BEARING FOR LINTELS UNLESS NOTED OTHERWISE. <br />STRUCTURAL STEEL: STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING: <br />W-SHAPES ASTM A992 GRADE 50. <br />CHANNELS, PLATES AND ANGLES ASTM A36. <br />RECTANGULAR AND SQUARE TUBES ASTM A500 GRADE B (Fy = 46KSI). <br />ROUND HSS ASTM A500 GRADE B (Fy = 42KS1). <br />PIPES ASTM A53 GRADE B (Fy = 35KSI). <br />DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE "AISC <br />SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS". <br />BOLTS SHALL CONFORM TO THE ASTM SPECIFICATION FOR A325 OR A490, HIGH <br />STRENGTH BOLTS. <br />WELDING SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN <br />BUILDING CONSTRUCTION. WELDS SHALL BE MADE USING E70XX ELECTRODES <br />AND SHALL BE 3/16" MINIMUM UNLESS OTHERWISE NOTED. <br />ANCHOR RODS: UNLESS INDICATED OTHERWISE ON THE DRAWINGS, ANCHOR <br />RODS SHALL BE ASTM F1554 GRADE 36 AND THE SIZE SHALL BE 3/4 DIA. AND SHALL <br />EMBED INTO THE CONCRETE FOUNDATION A DISTANCE OF V-0" WITH A HEAVY HEX <br />NUT AT THE EMBEDDED END. <br />STEEL JOISTS: STEEL JOISTS SHALL BE THE SIZE AND SPACING AS SHOWN ON THE <br />STRUCTURAL DRAWINGS AND SHALL BE DESIGNED, FABRICATED, INSTALLED AND <br />BRIDGED IN ACCORDANCE WITH THE STEEL JOIST INSTITUTE SPECIFICATIONS. <br />ENDS OF ALL BRIDGING LINES TERMINATING AT WALLS OR BEAMS SHALL BE <br />ANCHORED THERETO AT TOP AND BOTTOM CHORDS. THE JOIST MANUFACTURER <br />SHALL PROVIDE DESIGN CALCULATIONS FOR UPLIFT, EITHER CONFIRMING THE SJI <br />BRIDGING REQUIREMENT OR PROVIDING A DESIGN ADEQUATE FOR THE UPLIFT. <br />JOIST SIZES INDICATED ON PLANS ARE FOR STANDARD UNIFORM LOADING <br />CONDITIONS INCLUDING DEAD, LIVE, AND POSITIVE WIND PRESSURES. JOISTS <br />SHALL BE DESIGNED FOR ALL ADDITIONAL LOADS FROM ROOF TOP MECHANICAL <br />UNITS, SUSPENDED EQUIPMENT, SUSPENDED WALL LOADS, OR AS INDICATED ON <br />PLANS. JOISTS SHALL BE SPECIFICALLY DESIGNED FOR WIND UPLIFT. <br />STEEL JOISTS SHALL BE DESIGNED TO WITHSTAND THE FOLLOWING LOADS, UNLESS <br />NOTED OTHERWISE: <br />180 PLF DEAD LOAD <br />120 PLF LIVE LOAD <br />300 LB (ROOF LIVE LOAD) POINT LOAD AT ANY LOCATION ON THE TOP CHORD <br />NEGATIVE WIND PRESSURES IN ACCORDANCE WITH COMPONENT AND CLADDING <br />DIAGRAM USING 5 PSF DEAD LOAD FOR NET UPLIFT FORCE <br />ANY ADDITIONAL LOADS AS INDICATED ON PLANS <br />SUBMIT COMPLETE SHOP DRAWINGS AND CALCULATIONS, SIGNED AND SEALED BY <br />A STRUCTURAL ENGINEER LICENSED IN THE STATE OF FLORIDA, SUBSTANTIATING <br />ALL STRENGTH, BRIDGING, AND SERVICEABILITY CRITERIA. <br />STEEL ROOF DECK: STEEL ROOF DECK SHALL BE GALVANIZED AND CONFORM TO <br />ASTM A653, STRUCTURAL QUALITY. THE GALVANIZED COATING SHALL CONFORM TO <br />ASTM A653 G60; OR G90 WHERE LEFT PERMANENTLY EXPOSED TO WEATHER. <br />ATTACHMENTS, CLOSURES ETC. SHALL BE IN ACCORDANCE WITH MANUFACTURERS <br />RECOMMENDATIONS. <br />DECK WELDING SHALL BE 5/8" EFFECTIVE DIAMETER PUDDLE WELDS AT 12"O.C. AT <br />TRANSVERSE AND PERIMETER SUPPORTS, 16" O.C. AT LONGITUDINAL SUPPORTS, <br />AND MECHANICALLY FASTEN SIDE LAP CONNECTIONS USING #10 SELF TAPPING <br />SCREW AT 16" O.C. UNLESS NOTED OTHERWISE ON THE DRAWINGS. <br />REFERENCED SYMBOLS <br />SYMBOL DESCRIPTION <br />STEP IN WALL ELEVATION <br />SECTION MARK <br />1 SIM DETAIL SECTION NUMBER <br />A101 ON SHEET REFERENCE <br />STRUCTURAL MASONRY WALL <br />STRUCTURAL ABBREVIATIONS <br />AB <br />ANCHOR BOLT <br />AFF <br />ABOVE FINISHED FLOOR <br />ARCH <br />ARCHITECT, (URAL), (S) <br />BLDG <br />BUILDING <br />BO <br />BOTTOM OF <br />BOT <br />BOTTOM <br />BRIG <br />BEARING <br />CANT <br />CANTILEVER <br />CJ <br />CONTROL JOINT <br />CL <br />CENTERLINE <br />CLR <br />CLEAR, (ANCE) <br />CMU <br />CONCRETE MASONRY UNIT <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />CONT <br />CONTINUOUS <br />COORD <br />COORDINATE <br />DEMO <br />DEMOLITION <br />DET <br />DETAIL <br />0 <br />DIAMETER <br />DIM <br />DIMENSION <br />DL <br />DEAD LOAD <br />DWG <br />DRAWING <br />EA <br />EACH <br />EB <br />EMBED <br />EF <br />EACH FACE <br />EJ <br />EXPANSION JOINT <br />ELEV <br />ELEVATION <br />EQ <br />EQUAL <br />EW <br />EACH WAY <br />(E) <br />EXISTING <br />EXP <br />EXPANSION <br />FND <br />FOUNDATION <br />FTG <br />FOOTING <br />GA <br />GAGE, GAUGE <br />HORIZ <br />HORIZONTAL, (S) <br />HS <br />HEADED STUD <br />HDR <br />HEADER <br />INCL <br />INCLUDE, (ED), (ING) <br />K <br />KIP, (S) <br />LL <br />LIVE LOAD <br />MAX <br />MAXIMUM <br />MIN <br />MINIMUM <br />(N) <br />NEW <br />NO <br />NUMBER <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />OC <br />ON CENTER <br />OPP <br />OPPOSITE HAND <br />OWJ <br />OPEN WEB JOIST, (S) <br />PCF <br />POUNDS PER CUBIC FOOT <br />PL <br />PLATE <br />PLF <br />POUNDS PER LINEAR FOOT <br />PMT <br />PRE ENGINEERED METAL TRUSS <br />PWT <br />PRE ENGINEERED WOOD TRUSS <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />REINF <br />REINFORCE, (ED), (ING) <br />REQ <br />REQUIRED <br />RTU <br />ROOF TOP UNIT <br />SF <br />SQUARE FOOT <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />STD <br />STANDARD <br />TB <br />TIE BEAM <br />TO <br />TOP OF <br />TYP <br />TYPICAL <br />UNO <br />UNLESS NOTED OTHERWISE <br />VERT <br />VERTICAL, (S) <br />W/O <br />WITHOUT <br />WWF <br />WELDED WIRE FABRIC <br />W/ <br />-- WITH - <br />ALLOWABLE DESIGN WIND PRESSURE (PSF) <br />ZONE <br />TRIBUTARY AREA <br />10 SF <br />50 SF <br />100 SF <br />a = 4.4FT <br />INTERIOR 1 <br />10 / -26 <br />10 / -24 <br />10 / -23 <br />009 <br />EDGE 2 <br />10 / -43 <br />10 / -32 <br />20 / -28 <br />CORNER 3 <br />10 / -43 <br />10 / -32 <br />20 / -28 <br />mi <br />INTERIOR 4 <br />23 / -25 <br />21 / -23 <br />18 / -20 <br />a <br />3 <br />CORNER 5 <br />23 / -31 <br />21 / -26 <br />18 / -20 <br />SELECT STRUCTURAL <br />12573 New Brittany Blvd <br />Fort Myers, Florida 33907 <br />Phone: (239) 210-5090 <br />info@selectstructural.com <br />Certification Auth. 28357 <br />106 N 37TH STREET, SUITE C <br />ROGERS, ARKANSAS 72756 <br />W W W. BATESARCH ITECTS. CO M <br />TEL: 479.633.8165 <br />Copyright 2016 Bates & Associates, Architects <br />E Drawings and Specifications as instruments of service are and shall <br />remain the property of the Architect. They are not to be used on other <br />projects or extensions to this project except by agreement In writing <br />and with appropriate compensation to the Architect. <br />Contractor is responsible for confirming and correlating dimensions at <br />Job site; the Architect will not be responsible for construction means, <br />methods, techniques, sequences or procedures, or for safety <br />precautions and programs in connection with the project. <br />SITE/STORE #: <br />37745 <br />CONSTRUCTION MANAGER <br />CREIGHTON COMMERCIAL DEVELOPMENT <br />900 SW PINE ISLAND ROAD, SUITE 202 <br />CAPE CORAL, FL 33991 <br />TENANT <br />7-ELEVEN INC. <br />1722 ROUTH ST. SUITE 1000 DALLAS, TX 75201 <br />CONTACT: DANIELTUBB <br />STRUCTURAL CONSULTANT <br />SELECT STRUCTURAL <br />12573 NEW BRITTANY BLVD FORT MYERS, FL 33907 <br />CONTACT: SHAWN ANDERSON <br />MEP CONSULTANT <br />OMNI ENGINEERS <br />Z <br />W <br />5 <br />^ <br />CL <br />Oo <br />J N <br />p <br />W W <br />> F— <br />W <br />p <br />M <br />W D <br />0 <br />O <br />O <br />CL <br />M <br />O <br />J Q <br />M <br />CM <br />�— <br />(n <br />-. <br />G� O <br />J <br />LL <br />Z <br />�- <br />W <br />J <br />U o <br />� <br />-' <br />W <br />J <br />z <br />W <br />9 <br />C <br />� <br />a <br />its <br />= <br />� <br />� <br />� cn <br />O <br />U <br />J <br />w <br />M <br />CL <br />O z <br />W <br />a <br />ti <br />N <br />CU � <br />v <br />Oo <br />O <br />� <br />r= <br />V_ <br />W <br />U <br />,``►►► a i�►►► ►�i <br />N <br />515 <br />: G'. <br />.� O ,c� <br />STATE <br />OF :•44/% <br />P,.: \�,�. <br />0 R , O <br />M <br />REVISIONS <br />NO. DATE I DESCRIPTION <br />PROJECT NUMBER: 16018 <br />RELEASE DATE: 03/31/2016 <br />GENERAL NOTES <br />SELECT/STRUCTURAL <br />5 4 3 1 2 1 1 <br />