Laserfiche WebLink
6 5 <br />SCOPE OF WORK <br />►. <br />d 1. COORDINATE ROUTING AND FINAL LOCATIONS OF COMMUNICATIONS AND CONTROLS WIRING. <br />l.0 2. ALL EXTERIOR AND BELOW CEILING POWER, CONTROLS AND COMMUNICATIONS WIRING TO BE ROUTED IN CONDUIT. INSTALL <br />U1 CONDUIT FOR INTERIOR CONTROL AND COMMUNICATION WIRING ONLY IF REQUIRED BY AHJ. <br />IN 3. BELDEN CABLE NUMBERS ARE SHOWN ON WIRING DIAGRAM FOR CABLE REQUIREMENTS (SHIELDING, PLENUM RATING, AWG, ETC.). <br />ro PROVIDE BELDEN CABLE AS SHOWN, OR CONTACT BEST WIRE AND CABLE FOR APPROVED ALTERNATE CABLE. CONTACT PATRICK <br />HAMACK AT BEST WIRE AND CABLE (972) 658-9986 FOR QUESTIONS ABOUT CABLE REQUIREMENTS. <br />4. PROVIDE ALL FIELD WIRING BETWEEN HVAC AND REFRIGERATION EQUIPMENT AS SHOWN IN 3/EMS1.0. <br />0 5. INSTALL BACK -BOXES WITH CONDUIT STUB UP FOR HUMIDITY, TEMPERATURE AND CO2 SENSORS. DEVICES TO BE PROVIDED BY <br />CARRIER AND AUTOMATED LOGIC CORPORATION (ALC). <br />m 6. PROVIDE FINAL INSTALLATION AND CONNECTION OF CONTROL WIRING TO: LIGHTING CONTROL SYSTEM INCLUDING OVERRIDE <br />SWITCH, HVAC AND REFRIGERATION EQUIPMENT, HUMIDITY, TEMPERATURE AND CO2 SENSORS, AND EMS SYSTEM. <br />7. MOUNT AND PROVIDE POWER TO THE MAIN PANEL. <br />E I 8. ESTABLISH COMMUNICATION LINK BETWEEN THE MAIN PANEL AND BUILDING ETHERNET SWITCH. <br />9. CONTACT THE EMS SYSTEM MANUFACTURER AT (866) 390-4275 AND PROVIDE STARTUP OF MAIN PANEL, LIGHTING CONTROLS, HVAC <br />AND REFRIGERATION UNITS <br />C� <br />t'• <br />KEYED NOTES <br />O COORDINATE LOCATION WITH MECHANICAL <br />REFER TO 4/EMS1.0 FOR TLO, HUMIDITY SENSOR <br />O AND LIGHTING CONTACTOR WIRING DETAIL. REFER <br />TO 1/EMS1.0 FOR SMART CONTROLLER AND <br />EVAPORATOR WIRING DETAIL. <br />LIGHTING OVERRIDE SWITCH. INSTALL ON BACK <br />WALL ABOVE WORK SURFACE OF WORKSTATION <br />LOCATED IN BACK ROOM. <br />SYMBOL DESCRIPTION <br />TLO LIGHTING OVERRIDE SWITCH <br />S TEMPERATURE SENSOR <br />H HUMIDITY SENSOR <br />CO2 CARBON DIOXIDE SENSOR <br />CAT-5 EMS ETHERNET <br />PORT 22 <br />EMS <br />- 7-11 ROUTER MAIN <br />DRAWING IS FOR <br />REFERENCE ONLY. SEE <br />PLAN FOR EXACT <br />EQUIPMENT LOCATIONS. <br />Z PANEL <br />EMS 1 ! BELDEN #1269A <br />LIGHTING } <br />CONTACTOR 4 - <br />BELDEN #6300FE <br />BELDEN # <br />EVAP 1 <br />-- - -- EMS MASTER <br />MC SYSTEM 1 <br />MC <br />EMS <br />BELDEN #6321 UE - <br />EMS EVAP 2 / <br />SLAVE <br />SYSTEM 1 <br />I <br />MC <br />- I <br />RTU-2 MC <br />i <br />P� 1F EVAP 3 J <br />MC - -- SLAVE <br />SYSTEM 1 <br />MC BELDEN #6541 UE - <br />MC C BELDEN #6541 UE <br />CO2 S <br />1 <br />BELDEN #6202UE <br />EMS FIELD WIRING DIAGRAM <br />N.T.S. <br />EMS <br />N.T.S.- <br />4C, Unshielded, 22 AWG <br />Plgnunn Rated Cable <br />Control Panel CP-1 <br />POR I.22 E"a .':S.' ...a © 0 <br />991 � �© <br />TO <br />9 A�wret' C 0 0. P A T O = J? <br />m LGR}BOB <br />Ocotnnaramu.e O <br />.C-CEMt---r <br />LIGHTING SYSTEM REFRIGERATION SYSTEM <br />CONTROLLER CONTROLLER <br />o a Smart Controller <br />D <br />a <br />0 <br />-rel,..fil Mal _ <br />ZN,20 <br />BACret'� TO fI'AP MAS T F R <br />COATROL BOARD <br />O O <br />�O\ / TRANSFORMER I TRANSFORMER <br />106VA 40VA <br />CONTROL PANEL <br />Space <br />IRS Sensor <br />Supplied by Carrier <br />Field Wlred <br />CARRIER <br />[; <br />V oT u +r•eu <br />Coe SE 30R <br />o <br />V rM 7 R <br />Q <br />BACnet• 4 0.10v In <br />i�o F«x b iTAM <br />rer-ta..ov CONTROLIMODLAE `e or <br />11111 <br />I 20 • <br />PTIq UI-12 41e • <br />UI.71+ 16 • <br />told 17 • <br />••I IM0,41c- <br />Power UI-10 4 �e • <br />■ • 4n and 14 • <br />CI O Ul-W + Is • <br />w UI-D7+ 12' • <br />Gnd 11 • <br />ul-W4 e • <br />and • <br />ari UW + 7 • <br />• ■ i• Ul-034 6 • <br />•• � .. tine 6 • <br />! 2t 1-4w*e,..,rey.(-UI-02 4 4 <br />AM PWrout <br />A� • <br />Nr* Ames 1 12 • <br />om A"+ 11* • <br />� pip A0-6 f#nd 104AE <br />• <br />.+av AO-4 fond 8 •j�_ • <br />.w� + 7 •T • <br />roams A011od• seise F d Ilk <br />+ .4111 a A0-2 ono 4 • <br />+ ,. • <br />Q�■w Aa! and s .lr, • <br />-TX Xnet cUld EL <br />e���a— <br />� ev-E)�jpm741� a <br />i 1e I •� <br />avm *TX <br />In 0 <br />• 16 I •o <br />� � � Bo.s,�. n4 ;K • <br />12 • <br />12 •! <br />i <br />110-a I, • <br />a0 10 • <br />®die i 0 •� <br />130-sr ._, • <br />� eK7ldpat �+ra �� 7 • • <br />•■� low■1� C c • e I ON <br />�;• Mail� 4 i <br />..■ ,Yr■etata et}l 2.* • <br />1 •r` ■ <br />+io <br />ar. <br />■IW <br />0 <br />* Grayed out Inputs/Outputs <br />Factory wired <br />GAS / ELECTRIC RTU CONNECTION DIAGRAM <br />2 - <br />N.T.S. <br />D02 <br />SIGNAGE/CANOPY LIGHTS <br />Ltg. Contactor <br />By Elec, Typ. <br />TIMED <br />OVERRIDE <br />BUTTON <br />N H <br />Locate next to computer <br />120VAC `J'1u_ <br />By Elec <br />TRT <br />m <br />TLO INPUT e <br />E <br />Pow <br />p i <br />FM�% <br />m m m m <br />•no <br />m.,"AUTOMATFDLXIC" � <br />W <br />- <br />C O R P O R A T I O N <br />N3 <br />w �551 <br />CU: Ti(N�1:R <br />W S <br />Gro <br />["]14LStat Port <br />03 <br />W 2 <br />BACnet <br />D01 <br />PARKING LIGHTS <br />Ltg. Contactor <br />By Elec, Typ. <br />N H <br />120VAC .. <br />By Elec <br />N <br />24VAC <br />H <br />e <br />e <br />0 <br />SPARE <br />NG <br />(: <br />LIGHTING CONTROLS CONNECTION DIAGRAM <br />4 N.T.S. <br />DRAWINGS FOR INDICATION PURPOSES ONLY. <br />NUMBER AND TYPE OF UNITS TO BE COORDINATED. <br />INSTALLATION OF EMS BY AUTOMATED LOGIC (ALC). <br />— — — — <br />I 1 <br />I BEACON II <br />I <br />1 SMART <br />CONTROLLER <br />1 <br />MULTI #1 <br />MULTI #2 <br />1 <br />MULTI IN <br />MULTI OUT <br />MULTI IN <br />MULTI OUT <br />I I <br />I I <br />I I <br />I <br />SYSTEM #1 <br />I <br />MASTER <br />SLAVE-1 <br />SLAVE-2 <br />I <br />MULTI IN <br />MULTI OUT <br />MULTI IN MULTI OUT <br />MULTI IN <br />MULTI OUT <br />� l <br />� <br />1 -- . I <br />- - ----------- <br />-- -- - ------- <br />- <br />I I <br />1 TECHNICIAN TO TERMINATE <br />BEACON II SMART CONTROLLER <br />LS SHOWN.— DEVIATIONS'I — _ — _ I <br />REFRIGERATION <br />SYSTEM <br />CONNECTION <br />DIAGRAM <br />N.T.S. <br />oases <br />106 N 37TH STREET, SUITE C <br />ROGERS, ARKANSAS 72756 <br />W W W. BATESARCH ITECTS.COM <br />TEL: 479.633.8165 <br />Copyright 2016 Bates & Associates, Architects <br />Drawings and Specifications as instruments of service are and shall remain <br />the property of the Architect. They are not to he used on other projects or <br />extensions to this project except by agreement in writing and with <br />appropriate compensation to the Architect. <br />Contractor is responsible for confirming and correlating dimensions at job <br />site; the Architect will not be responsible for construction means, methods, <br />techniques, sequences or procedures, or for safety precautions and <br />programs in connection with the project. - - — <br />SITE/STORE #: <br />1037728 <br />CONSTRUCTION MANAGER <br />CREIGHTON CONST. & MGMT <br />900 SW PINE ISLAND ROAD, SUITE 202, <br />CAPE CORAL, FL 33991 <br />DEVELOPER CONTACT <br />TENANT <br />7-ELEVEN INC. <br />1722 ROUTH ST. SUITE 1000 DALLAS, TX 75201 <br />DANIELTUBB <br />STRUCTURAL CONSULTANT <br />ARCH CONSULTING ENGINEERS <br />510 S CONGRESS SUITE B-100 AUSTIN, TX 78704 <br />JUSTIN BILLODEAU <br />MEP CONSULTANT <br />WALTER J. FITZGERALD, P.E. 24636 <br />2566 NEBRASKA AVE. APT 443 <br />PALM HARBOR, FL 34684 PH (813) 785-7526 <br />NMI <br />C\ <br />C� <br />C <br />N <br />0 <br />Lij <br />LJJ <br />T <br />`Cr <br />06 <br />Cn <br />a-) <br />O <br />O <br />CL <br />M <br />M <br />Q <br />M <br />M <br />U) <br />>_ <br />LL <br />O <br />� <br />LL <br />z <br />� <br />w <br />U)z <br />J <br />O <br />z <br />J <br />Q <br />w <br />� <br />= <br />U <br />Q <br />O <br />C <br />w <br />06 <br />� <br />z <br />; <br />U <br />-J <br />W <br />o= <br />O <br />I--- <br />ww <br />c� <br />LJJ <br />z <br />Q <br />W <br />() <br />g <br />U <br />� <br />i <br />`���IIIIIIIIII/////7 <br />-9�. a , <br />V No.24636 •� <br />•Al <br />IIIII <br />0 3131120) <br />Architect Name - RYANMFAUST <br />ArchitectNumberAR9DOCUMENT <br />905 <br />SIGNATURETHE SEAL AND ONLY TT0 WHICH <br />THEY ARE AFFIXED AND WE EXPRESSLY DISCLAIM ANY RESPONSIBILITY FOR <br />ALL OTHER PLANS, SPECIFICATIONS, ESTIMATES, REPORTS OR OTHER <br />DOCUMENTS OR INSTRUMENTS RELATING TO OR INTENDED TO BE USED <br />FOR ANY PART OR PARTS OF THE PROJECT. <br />REVISIONS <br />NO. DATE I DESCRIPTION <br />A PROJECT NUMBER: <br />16-021 <br />RELEASE DATE: 03/31/2016 <br />ENERGY MANAGEMENT <br />SYSTEM <br />6 5 4 <br />3 <br />1 <br />