<br />PLUMBING FIXTURE SCHEDULE
<br />TAG
<br />FIXTURE
<br />MANUFACTURER
<br />MODEL
<br />CW
<br />HW
<br />WASTE
<br />VENT
<br />DESCRIPTION
<br />CADET
<br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. 12" ROUGH -IN,
<br />AMERICAN
<br />3483.001 (BOWL)
<br />COLOR: WHITE AMERICAN STANDARD CADET OPEN FRONT SEAT, NO COVER. 17" RIM HEIGHT, FOR
<br />WC
<br />WATER CLOSET
<br />STANDARD
<br />4142.100 (TANK)(L)
<br />1/2
<br />---
<br />4"
<br />2"
<br />HANDICAPPED. PRESSURE ASSISTED 1.1 GPF. MOUNT CONTROLS ON ACCESSIBLE SIDE OF TOILET.
<br />4142.801 (TANK)(R)
<br />CONTRACTOR TO COORDINATE WITH FIXTURE SUPPLIER FOR LEFT/RIGHT HAND FLUSH LEVER TO
<br />COMPLY WITH ADA REQUIREMENTS.
<br />FAUCET PACKAGE PROVIDED BY OWNER. FIXTURE AND OTHER HARDWARE FURNISHED AND INSTALLED
<br />BY PLUMBING CONTRACTOR. WALL -MOUNT WITH ZURN Z1231 CONCEALED ARM CARRIER, 4" CENTERS
<br />BRENHAM
<br />WITH CHROME T&S MODEL EC-3103-TMV (EF-1 #479, ASSE 1070 COMPLIANT) MOTION ACTIVATED
<br />LAV
<br />LAVATORY
<br />KOHLER
<br />K-1997-4
<br />1/2"
<br />1/2"
<br />1 1/4"
<br />1 1/4"
<br />FAUCET,B-0199-03-N05 AERATOR (0.5 GPM). FAUCET INCLUDES AC/DC CONTROL MODULE W/ INTEGRAL
<br />FLOW CONTROL SETTING, TEMPERATURE CONTROL MIXING VALVE SET TO 105°F W/ INTEGRAL CHECK
<br />VALVES, 18" STAINLESS STEEL FLEXIBLE HOSES. INSTALL KOHLER BRENHAM SHROUD K-1998.REF
<br />ARCHITECTURAL DRAWINGS FOR ROUGH -IN ELEVATIONS.
<br />MS
<br />MOP SINK
<br />FIAT
<br />MSB-2424
<br />1/2"
<br />1/2"
<br />3"
<br />1 1/2"
<br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. NO. 830AA FAUCET
<br />WITH INTEGRAL VACUUM BREAKER, NO.832-AAHOSE AND BRACKET, NO.1453BB FLOOR STRAINER AND
<br />NO. 899-CC MOP HANGER
<br />FIXTURE AND HARDWARE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. ADA
<br />S1
<br />HAND SINK
<br />---
<br />---
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />COMPLIANT, STAINLESS STEEL FIXTURE, BRASS FAUCET & P-TRAP. PROVIDED WITH STOP VALVES,
<br />FLEXIBLE SUPPLY RISERS, TRUBRO LAV GUARD 2 PROTECTIVE PIPE COVERS ON EXPOSED HOT
<br />WATER AND DRAIN LINES AND TEMPERATURE -ACTUATING MIXING VALVE & SET TO 105' F.
<br />FIXTURE AND HARDWARE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. ADA
<br />S2
<br />HAND SINK
<br />SELECT STAINLESS
<br />PL-SHS-1
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />COMPLIANT, CUSTOM WALL MOUNT 10" FRONT TO BACK X 14"W X 6"D HAND SINK (PRODUCTION LINE.
<br />PROVIDED WITH BRASS FAUCET SUPPLIER PART #B-1146 & P-TRAP, INSTALL TRUEBRO LAV GUARD 2
<br />PROTECTIVE PIPE COVERS ON EXPOSED HOT WATER AND DRAIN LINES, STOP VALVES AND
<br />TEMPERATURE -ACTUATING MIXING VALVE & SET TO 105' F.
<br />3-COMPARTMENT SINK
<br />SELECT STAINLESS
<br />1/2"
<br />FIXTURE AND HARDWARE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. PROVIDED
<br />S3
<br />SS-3B1219-2D18
<br />1/2"
<br />3"
<br />2"
<br />WITH T&S BRASS FAUCET MPY-8WCN-08-CR (EF-1 #600), P-TRAP AND STOP VALVES.
<br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. BOX TYPE, CAST
<br />FPWH
<br />FREEZE -PROOF WALL
<br />JOSAM
<br />71000
<br />3/4"
<br />__
<br />___
<br />___
<br />BRONZE, INTEGRAL VACUUM BREAKER-BACKFLOW PREVENTER, "T" HANDLE, POLISHED FACE, HINGED
<br />HYDRANT
<br />LOCKING COVER, BRONZE WALL CASTING, RENEWABLE SEAT, BRONZE OPERATING PARTS, 1" N.P.T.
<br />INLET, AND 3/4" H.P.T. OUTLET.
<br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. BRASS THREADED
<br />HB
<br />HOSE BIBB
<br />MUELLER
<br />108-054HN
<br />3/4"
<br />---
<br />---
<br />---
<br />SILLCOCK WITH FLANGE AND QUARTER -TURN OPERATION, 3/4" N.P.T. INLET, AND 3/4" H.P.T. OUTLET.
<br />PROVIDED WITH 25 FOOT HOSE AND SPRAY GUN. MOUNT 24" AFF.
<br />SPECIALTY PLUMBING FIXTURE SCHEDULE
<br />TAG FIXTURE MANUFACTURER MODEL DESCRIPTION NOTES
<br />WHA
<br />WATER HAMMER
<br />SIOUX CHIEF
<br />652-A
<br />CONFORM TO PDI WH-201, ASSE 1010; TEMP TO 250°F,
<br />A
<br />ARRESTOR
<br />MAX 350 PSIG WORKING PRESSURE
<br />+/- 3°F UP TO 120°F, WITH BUILT-IN CHECK VALVES, BRASS BODY,
<br />TMV
<br />TEMPERATURE
<br />WATTS
<br />LFUSG-B-M1
<br />MIXING VALVE
<br />AND COPPER THERMOSTAT.
<br />TRAP PRIMER
<br />SIOUX CHIEF
<br />695
<br />BRONZE PRIMER VALVE WITH REMOVABLE OPERATING PARTS INTEGRAL
<br />VACUUM BREAKER, AND GASKETED ACCESS COVER.
<br />RPZ
<br />REDUCED PRESSURE
<br />WATTS
<br />LF909QTS
<br />LEAD FREE BRONZE BODY, WITH SHUT-OFF VALVES,
<br />BACKFLOW PREVENTER
<br />Y STRAINER, AND TEST COCKS.
<br />FD
<br />FLOOR DRAIN
<br />SIOUX CHIEF
<br />832-36PNQ
<br />-
<br />3" LIGHT DUTY DRAIN WITH 7" SQUARE TOP, PVC BODY WITH NICKEL
<br />BRONZE RING AND STRAINER. PROVIDED WITH 3" DRAIN AND 1 1/2" VENT.
<br />FS
<br />FLOOR SINK
<br />SIOUX CHIEF
<br />861
<br />WHITE PVC 12" X 12" FLOOR SINK WITH 3/4" HEAVY DUTY PVC HALF GRATE,
<br />SEDIMENT BUCKET. PROVIDED WITH 3" DRAIN AND 1 1/2" VENT.
<br />FCO
<br />FLOOR CLEANOUT
<br />SIOUX CHIEF
<br />851
<br />PVC BODY, ROUND HEAVY-DUTY CAST IRON TOP, POLYPROPYLENE OR
<br />B
<br />ABS PLUG, ADJUSTABLE TO FINISH SURFACE
<br />YCO
<br />YARD CLEANOUT
<br />SIOUX CHIEF
<br />834
<br />DURA-COATED CAST IRON, DOUBLE -FLANGED HOUSING, AND HEAVY-DUTY
<br />B
<br />SIOUX CHIEF
<br />SCORIATED DUCTILE IRON COVER.
<br />WCO
<br />WALL CLEANOUT
<br />873
<br />THREADED, COUNTERSUNK BRONZE CLEANOUT PLUG. PROVIDE DRILLED TAP
<br />FOR CENTER SCREW AND STAINLESS STEEL COVER.
<br />NOTES:
<br />A. SIZE PER MANUFACTURER'S RECOMMENDATION.
<br />B. CLEANOUT SHALL BE SAME SIZE AS PIPE BEING SERVED.
<br />C. THIS SCHEDULE IS COMPREHENSIVE. ALL MARKS MAY OR MAY
<br />NOT BE USED ON PLANS.
<br />PLUMBING SANITARY PLAN
<br />1/4" = 1'-0"
<br />FC
<br />3 2
<br />I�
<br />ROUTE VENT
<br />j 2" TIGHT TO
<br />EXTERIOR WALL
<br />WCO
<br />SANITARY RISER
<br />2 ---
<br />N.T.S.
<br />WCO - -
<br />/P1.0 AND
<br />FOR
<br />INUATION
<br />4" SEWER, REF.
<br />CIVIL FOR
<br />CONTINUATION
<br />PLUMBING SYMBOLS
<br />SS
<br />SANITARY SEWER
<br />GW
<br />GREASE WASTE
<br />— - — - — - —
<br />DOMESTIC COLD WATER
<br />-------
<br />DOMESTIC HOT WATER
<br />---
<br />DOMESTIC HOT WATER RETURN
<br />— —FW— —
<br />FILTERED WATER
<br />G
<br />NATURAL GAS
<br />CD
<br />CONDENSATE DRAIN
<br />— — — —
<br />PLUMBING VENT
<br />UNION
<br />C
<br />ELBOW - TURNED DOWN
<br />0—
<br />ELBOW - TURNED UP
<br />..
<br />TEE - TURNED DOWN
<br />TEE - TURNED UP
<br />BALL VALVE
<br />SHUT-OFF VALVE IN VERTICAL LINE
<br />BACKFLOW PREVENTER
<br />❑O- FD
<br />FLOOR DRAIN
<br />® FS
<br />FLOOR SINK
<br />—O FCO
<br />FLOOR CLEANOUT
<br />----0 YCO
<br />YARD CLEANOUT
<br />FPWH
<br />FREEZE PROOF WALL HYDRANT
<br />---�- HB
<br />HOSE BIBB
<br />�I WCO
<br />WALL CLEANOUT
<br />GAS PRESSURE REGULATOR
<br />GAS COCK
<br />PLUMBING NOTES
<br />1. NOTES APPLY TO ALL PLUMBING SHEETS.
<br />2. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING
<br />THOROUGH KNOWLEDGE OF ALL DRAWINGS AND
<br />SPECIFICATIONS AS THEY RELATE TO THIS WORK. NO
<br />ADDITIONAL COMPENSATION SHALL BE ALLOWED DUE
<br />TO LACK OF THIS KNOWLEDGE.
<br />3. PROVIDE ALL MATERIALS FOR A COMPLETE
<br />INSTALLATION IN ALL RESPECTS READY FOR INTENDED
<br />USE AND IN STRICT ACCORDANCE WITH STATE AND
<br />LOCAL CODES AND MANUFACTURER'S
<br />RECOMMENDATIONS.
<br />4. COORDINATE SEWER AND WATER CONNECTIONS
<br />WITH CIVIL AND AHJ. PROVIDE PRESSURE REDUCING
<br />VALVE AND BACKFLOW PREVENTER AS SHOWN OR
<br />REQUIRED BY AHJ. VERIFY INVERT AND SLOPE OF
<br />INCOMING SANITARY SEWER BEFORE TRENCHING.
<br />5. REFER TO RISER DIAGRAMS AND PLUMBING
<br />FIXTURE SCHEDULE FOR ALL PIPING AND PIPE SIZES
<br />NOT SHOWN ON PLAN.
<br />6. SANITARY AND STORM SEWER PIPING SHOWN IS
<br />BASED ON 1/4" PER FOOT FALL FOR ALL PIPE SMALLER
<br />THAN 3" DIAMETER AND 1/8" PER FOOT FALL FOR PIPE
<br />3" DIAMETER AND LARGER.
<br />7. ALL SEWER PIPING BELOW SLAB TO BE 2"
<br />DIAMETER MINIMUM.
<br />8. PROVIDE ACCESS DOORS TO ALL CONCEALED
<br />VALVES AND CLEAN -OUTS; AND NOT ABOVE AN
<br />ACCESSIBLE CEILING.
<br />9. PROVIDE TRAP SEAL PRIMERS AND 1/2" COPPER
<br />TUBING CONNECTION TO ALL FLOOR DRAINS AS SHOWN
<br />OR AS REQUIRED BY AHJ. CONTRACTOR SHALL VERIFY
<br />REQUIREMENTS.
<br />10. INSTALL VTR'S, EXHAUST FANS, AND FLUES A
<br />MINIMUM 5'-0" FROM PARAPET OR OUTSIDE WALL AND
<br />10'-0" MINIMUM FROM EQUIPMENT WITH OUTSIDE AIR
<br />INTAKE.
<br />11. INSTALL WATER PIPE ON INSIDE OF EXTERIOR
<br />WALL INSULATION TO PREVENT FREEZING.
<br />12. WHEN DEEP FROST LOCATIONS ARE
<br />ENCOUNTERED, ROUTE SANITARY LINES UNDER
<br />BUILDING AS MUCH AS POSSIBLE.
<br />13. PROVIDE PVC SLEEVE FOR ALL COLD/HOT WATER
<br />FLOOR PIPE PENETRATIONS. MAKE SLEEVE LARGE
<br />ENOUGH FOR INSULATION. SEAL WITH GRAY MASTIC
<br />AND ENSURE OF NO WATER PENETRATIONS.
<br />14. PROVIDE AND INSTALL WATTS 8A VACUUM
<br />BREAKER ON ANY THREADED EXTERIOR OR INTERIOR
<br />FAUCETS.
<br />15. ALL WATER SHUT-OFF VALVES SHALL BE "BALL
<br />LOCK" TYPE. PROVIDE SHUT-OFF VALVES AT EACH
<br />TERMINATION POINT OF ASSOCIATED EQUIPMENT.
<br />16. PROVIDE SEISMIC BRACING BASED ON
<br />APPROPRIATE SEISMIC ZONE REQUIREMENTS PER
<br />LOCAL AND NATIONAL CODES. CONTRACTOR'S
<br />RESPONSIBILITY INCLUDES STRUCTURAL ENGINEER'S
<br />CERTIFICATION ON DETAILS SUBMITTED FOR
<br />PERMITTING.
<br />E
<br />C
<br />me 0
<br />A
<br />KVUC11�1, AKRHINZOAZO
<br />WWW.BATESARCHITECTS.COM
<br />TEL: 479.633.8165
<br />Copyright 2016 Bates & Associates, Architects
<br />Drawings and Specifications as instruments of service are and shall remain
<br />the property of the Architect. They are not to be used on other projects or
<br />extensions to this project except by agreement in writing and with
<br />appropriate compensation to the Architect.
<br />Contractor is responsible for confirming and correlating dimensions at job
<br />site; the Architect will not be responsible for construction means, methods,
<br />techniques, sequences or procedures, or for safety precautions and
<br />programs in connection with the project.
<br />SITE/STORE #:
<br />1037728
<br />I CONSTRUCTION MANAGER
<br />CREIGHTON CONST. & MGMT
<br />I 900 SW PINE ISLAND ROAD, SUITE 202,
<br />CAPE CORAL, FL 33991
<br />DEVELOPER CONTACT
<br />TENANT
<br />7-ELEVEN INC.
<br />1722 ROUTH ST. SUITE 1000 DALLAS, TX 75201
<br />DANIELTUBB
<br />STRUCTURAL CONSULTANT
<br />ARCH CONSULTING ENGINEERS
<br />510 S CONGRESS SUITE B-100 AUSTIN, TX 78704
<br />JUSTIN BILLODEAU
<br />MEP CONSULTANT
<br />WALTER J. FITZGERALD, P.E. 24636
<br />2566 NEBRASKA AVE. APT 443
<br />PALM HARBOR, FL 34684 PH (813) 785-7526
<br />C� N
<br />c N
<br />p (D LLI
<br />W Z) a�
<br />z LO °6 rn
<br />O °CL M Q M
<br />>- L O LL.
<br />� Cn z
<br />z LU J O o Q
<br />> 0 z -1 U
<br />J-r-- O - W
<br />W o f z
<br />I` N = � U
<br />_ (.D
<br />W (o
<br />I..f� O
<br />U 0')
<br />60
<br />_,
<br />S OF X_
<br />�•O R 1
<br />(03 61A1110
<br />Architect Name - RYAN M FAUST
<br />Architect Number - AR97905
<br />THE SEAL AND SIGNATURE APPLY ONLY TO THE DOCUMENT TO WHICH
<br />THEY ARE AFFIXED AND WE EXPRESSLY DISCLAIM ANY RESPONSIBILITY FOR
<br />ALL OTHER PLANS, SPECIFICATIONS, ESTIMATES, REPORTS OR OTHER
<br />DOCUMENTS OR INSTRUMENTS RELATING TO OR INTENDED TO BE USED
<br />FOR ANY PART OR PARTS OF THE PROJECT.
<br />REVISIONS
<br />NO. DATE DESCRIPTION
<br />PROJECT NUMBER: 16-021
<br />RELEASE DATE: 03/31/2016
<br />DRAIN PIPING PLAN
<br />RISER AND SCHEDULES