Laserfiche WebLink
I <br />In <br />7i <br />L11 <br />0 <br />N <br />rn <br />rr) <br />E <br />0 <br />C <br />IE <br />v <br />E <br />t <br />v <br />�I <br />c-I <br />I <br />d <br />LU <br />I <br />v <br />ao <br />c <br />C7 <br />oZS <br />C7 <br />C1 <br />J <br />U— <br />vi <br />A <br />L <br />Q <br />(1 <br />N <br />00 <br />0 <br />f�o <br />Ln <br />U <br />v I <br />0 <br />L <br />0 <br />� I <br />0 <br />N <br />U <br />6 5 4 <br />PLUMBING FIXTURE SCHEDULE <br />TAG <br />FIXTURE <br />MANUFACTURER <br />MODEL <br />CW <br />HW <br />WASTE <br />VENT <br />DESCRIPTION <br />CADET <br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. 12" ROUGH -IN, <br />AMERICAN <br />3483.001 (BOWL) <br />COLOR: WHITE AMERICAN STANDARD CADET OPEN FRONT SEAT, NO COVER. 17" RIM HEIGHT, FOR <br />WC <br />WATER CLOSET <br />STANDARD <br />4142.100 (TANK)(L) <br />1/2 <br />--- <br />4" <br />2" <br />HANDICAPPED. PRESSURE ASSISTED 1.1 GPF. MOUNT CONTROLS ON ACCESSIBLE SIDE OF TOILET. <br />4142.801 (TANK)(R) <br />CONTRACTOR TO COORDINATE WITH FIXTURE SUPPLIER FOR LEFT/RIGHT HAND FLUSH LEVER TO <br />COMPLY WITH ADA REQUIREMENTS. <br />FAUCET PACKAGE PROVIDED BY OWNER. FIXTURE AND OTHER HARDWARE FURNISHED AND INSTALLED <br />BY PLUMBING CONTRACTOR. WALL -MOUNT WITH ZURN Z1231 CONCEALED ARM CARRIER, 4" CENTERS <br />BRENHAM <br />WITH CHROME T&S MODEL EC-3103-TMV (EF-1 #479, ASSE 1070 COMPLIANT) MOTION ACTIVATED <br />LAV <br />LAVATORY <br />KOHLER <br />K-1997-4 <br />1/2" <br />1/2" <br />1 1/4" <br />1 1/4" <br />FAUCET,B-0199-03-N05 AERATOR (0.5 GPM). FAUCET INCLUDES AC/DC CONTROL MODULE W/ INTEGRAL <br />FLOW CONTROL SETTING, TEMPERATURE CONTROL MIXING VALVE SET TO 105°F W/ INTEGRAL CHECK <br />VALVES, 18" STAINLESS STEEL FLEXIBLE HOSES. INSTALL KOHLER BRENHAM SHROUD K-1998.REF <br />ARCHITECTURAL DRAWINGS FOR ROUGH -IN ELEVATIONS. <br />MS <br />MOP SINK <br />FIAT <br />MSB-2424 <br />1/2" <br />1/2" <br />3" <br />1 1/2" <br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. NO. 830AA FAUCET <br />WITH INTEGRAL VACUUM BREAKER, NO.832-AAHOSE AND BRACKET, NO.1453BB FLOOR STRAINER AND <br />NO. 899-CC MOP HANGER <br />FIXTURE AND HARDWARE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. ADA <br />S1 <br />HAND SINK <br />--- <br />--- <br />1/2" <br />1/2" <br />1 1/2" <br />1 1/2" <br />COMPLIANT, STAINLESS STEEL FIXTURE, BRASS FAUCET & P-TRAP. PROVIDED WITH STOP VALVES, <br />FLEXIBLE SUPPLY RISERS, TRUBRO LAV GUARD 2 PROTECTIVE PIPE COVERS ON EXPOSED HOT <br />WATER AND DRAIN LINES AND TEMPERATURE -ACTUATING MIXING VALVE & SET TO 105' F. <br />FIXTURE AND HARDWARE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. ADA <br />S2 <br />HAND SINK <br />SELECT STAINLESS <br />PL-SHS-1 <br />1/2" <br />1/2" <br />1 1/2" <br />1 1/2" <br />COMPLIANT, CUSTOM WALL MOUNT 10" FRONT TO BACK X 14"W X 6"D HAND SINK (PRODUCTION LINE. <br />PROVIDED WITH BRASS FAUCET SUPPLIER PART #B-1146 & P-TRAP, INSTALL TRUEBRO LAV GUARD 2 <br />PROTECTIVE PIPE COVERS ON EXPOSED HOT WATER AND DRAIN LINES, STOP VALVES AND <br />TEMPERATURE -ACTUATING MIXING VALVE & SET TO 105' F. <br />3-COMPARTMENT SINK <br />SELECT STAINLESS <br />1/2" <br />FIXTURE AND HARDWARE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. PROVIDED <br />S3 <br />SS-3B1219-2D18 <br />1/2" <br />3" <br />2" <br />WITH T&S BRASS FAUCET MPY-8WCN-08-CR (EF-1 #600), P-TRAP AND STOP VALVES. <br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. BOX TYPE, CAST <br />FPWH <br />FREEZE -PROOF WALL <br />JOSAM <br />71000 <br />3/4" <br />__ <br />___ <br />___ <br />BRONZE, INTEGRAL VACUUM BREAKER-BACKFLOW PREVENTER, "T" HANDLE, POLISHED FACE, HINGED <br />HYDRANT <br />LOCKING COVER, BRONZE WALL CASTING, RENEWABLE SEAT, BRONZE OPERATING PARTS, 1" N.P.T. <br />INLET, AND 3/4" H.P.T. OUTLET. <br />FIXTURE AND HARDWARE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. BRASS THREADED <br />HB <br />HOSE BIBB <br />MUELLER <br />108-054HN <br />3/4" <br />--- <br />--- <br />--- <br />SILLCOCK WITH FLANGE AND QUARTER -TURN OPERATION, 3/4" N.P.T. INLET, AND 3/4" H.P.T. OUTLET. <br />PROVIDED WITH 25 FOOT HOSE AND SPRAY GUN. MOUNT 24" AFF. <br />SPECIALTY PLUMBING FIXTURE SCHEDULE <br />TAG FIXTURE MANUFACTURER MODEL DESCRIPTION NOTES <br />WHA <br />WATER HAMMER <br />SIOUX CHIEF <br />652-A <br />CONFORM TO PDI WH-201, ASSE 1010; TEMP TO 250°F, <br />A <br />ARRESTOR <br />MAX 350 PSIG WORKING PRESSURE <br />+/- 3°F UP TO 120°F, WITH BUILT-IN CHECK VALVES, BRASS BODY, <br />TMV <br />TEMPERATURE <br />WATTS <br />LFUSG-B-M1 <br />MIXING VALVE <br />AND COPPER THERMOSTAT. <br />TRAP PRIMER <br />SIOUX CHIEF <br />695 <br />BRONZE PRIMER VALVE WITH REMOVABLE OPERATING PARTS INTEGRAL <br />VACUUM BREAKER, AND GASKETED ACCESS COVER. <br />RPZ <br />REDUCED PRESSURE <br />WATTS <br />LF909QTS <br />LEAD FREE BRONZE BODY, WITH SHUT-OFF VALVES, <br />BACKFLOW PREVENTER <br />Y STRAINER, AND TEST COCKS. <br />FD <br />FLOOR DRAIN <br />SIOUX CHIEF <br />832-36PNQ <br />- <br />3" LIGHT DUTY DRAIN WITH 7" SQUARE TOP, PVC BODY WITH NICKEL <br />BRONZE RING AND STRAINER. PROVIDED WITH 3" DRAIN AND 1 1/2" VENT. <br />FS <br />FLOOR SINK <br />SIOUX CHIEF <br />861 <br />WHITE PVC 12" X 12" FLOOR SINK WITH 3/4" HEAVY DUTY PVC HALF GRATE, <br />SEDIMENT BUCKET. PROVIDED WITH 3" DRAIN AND 1 1/2" VENT. <br />FCO <br />FLOOR CLEANOUT <br />SIOUX CHIEF <br />851 <br />PVC BODY, ROUND HEAVY-DUTY CAST IRON TOP, POLYPROPYLENE OR <br />B <br />ABS PLUG, ADJUSTABLE TO FINISH SURFACE <br />YCO <br />YARD CLEANOUT <br />SIOUX CHIEF <br />834 <br />DURA-COATED CAST IRON, DOUBLE -FLANGED HOUSING, AND HEAVY-DUTY <br />B <br />SIOUX CHIEF <br />SCORIATED DUCTILE IRON COVER. <br />WCO <br />WALL CLEANOUT <br />873 <br />THREADED, COUNTERSUNK BRONZE CLEANOUT PLUG. PROVIDE DRILLED TAP <br />FOR CENTER SCREW AND STAINLESS STEEL COVER. <br />NOTES: <br />A. SIZE PER MANUFACTURER'S RECOMMENDATION. <br />B. CLEANOUT SHALL BE SAME SIZE AS PIPE BEING SERVED. <br />C. THIS SCHEDULE IS COMPREHENSIVE. ALL MARKS MAY OR MAY <br />NOT BE USED ON PLANS. <br />PLUMBING SANITARY PLAN <br />1/4" = 1'-0" <br />FC <br />3 2 <br />I� <br />ROUTE VENT <br />j 2" TIGHT TO <br />EXTERIOR WALL <br />WCO <br />SANITARY RISER <br />2 --- <br />N.T.S. <br />WCO - - <br />/P1.0 AND <br />FOR <br />INUATION <br />4" SEWER, REF. <br />CIVIL FOR <br />CONTINUATION <br />PLUMBING SYMBOLS <br />SS <br />SANITARY SEWER <br />GW <br />GREASE WASTE <br />— - — - — - — <br />DOMESTIC COLD WATER <br />------- <br />DOMESTIC HOT WATER <br />--- <br />DOMESTIC HOT WATER RETURN <br />— —FW— — <br />FILTERED WATER <br />G <br />NATURAL GAS <br />CD <br />CONDENSATE DRAIN <br />— — — — <br />PLUMBING VENT <br />UNION <br />C <br />ELBOW - TURNED DOWN <br />0— <br />ELBOW - TURNED UP <br />.. <br />TEE - TURNED DOWN <br />TEE - TURNED UP <br />BALL VALVE <br />SHUT-OFF VALVE IN VERTICAL LINE <br />BACKFLOW PREVENTER <br />❑O- FD <br />FLOOR DRAIN <br />® FS <br />FLOOR SINK <br />—O FCO <br />FLOOR CLEANOUT <br />----0 YCO <br />YARD CLEANOUT <br />FPWH <br />FREEZE PROOF WALL HYDRANT <br />---�- HB <br />HOSE BIBB <br />�I WCO <br />WALL CLEANOUT <br />GAS PRESSURE REGULATOR <br />GAS COCK <br />PLUMBING NOTES <br />1. NOTES APPLY TO ALL PLUMBING SHEETS. <br />2. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING <br />THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS AS THEY RELATE TO THIS WORK. NO <br />ADDITIONAL COMPENSATION SHALL BE ALLOWED DUE <br />TO LACK OF THIS KNOWLEDGE. <br />3. PROVIDE ALL MATERIALS FOR A COMPLETE <br />INSTALLATION IN ALL RESPECTS READY FOR INTENDED <br />USE AND IN STRICT ACCORDANCE WITH STATE AND <br />LOCAL CODES AND MANUFACTURER'S <br />RECOMMENDATIONS. <br />4. COORDINATE SEWER AND WATER CONNECTIONS <br />WITH CIVIL AND AHJ. PROVIDE PRESSURE REDUCING <br />VALVE AND BACKFLOW PREVENTER AS SHOWN OR <br />REQUIRED BY AHJ. VERIFY INVERT AND SLOPE OF <br />INCOMING SANITARY SEWER BEFORE TRENCHING. <br />5. REFER TO RISER DIAGRAMS AND PLUMBING <br />FIXTURE SCHEDULE FOR ALL PIPING AND PIPE SIZES <br />NOT SHOWN ON PLAN. <br />6. SANITARY AND STORM SEWER PIPING SHOWN IS <br />BASED ON 1/4" PER FOOT FALL FOR ALL PIPE SMALLER <br />THAN 3" DIAMETER AND 1/8" PER FOOT FALL FOR PIPE <br />3" DIAMETER AND LARGER. <br />7. ALL SEWER PIPING BELOW SLAB TO BE 2" <br />DIAMETER MINIMUM. <br />8. PROVIDE ACCESS DOORS TO ALL CONCEALED <br />VALVES AND CLEAN -OUTS; AND NOT ABOVE AN <br />ACCESSIBLE CEILING. <br />9. PROVIDE TRAP SEAL PRIMERS AND 1/2" COPPER <br />TUBING CONNECTION TO ALL FLOOR DRAINS AS SHOWN <br />OR AS REQUIRED BY AHJ. CONTRACTOR SHALL VERIFY <br />REQUIREMENTS. <br />10. INSTALL VTR'S, EXHAUST FANS, AND FLUES A <br />MINIMUM 5'-0" FROM PARAPET OR OUTSIDE WALL AND <br />10'-0" MINIMUM FROM EQUIPMENT WITH OUTSIDE AIR <br />INTAKE. <br />11. INSTALL WATER PIPE ON INSIDE OF EXTERIOR <br />WALL INSULATION TO PREVENT FREEZING. <br />12. WHEN DEEP FROST LOCATIONS ARE <br />ENCOUNTERED, ROUTE SANITARY LINES UNDER <br />BUILDING AS MUCH AS POSSIBLE. <br />13. PROVIDE PVC SLEEVE FOR ALL COLD/HOT WATER <br />FLOOR PIPE PENETRATIONS. MAKE SLEEVE LARGE <br />ENOUGH FOR INSULATION. SEAL WITH GRAY MASTIC <br />AND ENSURE OF NO WATER PENETRATIONS. <br />14. PROVIDE AND INSTALL WATTS 8A VACUUM <br />BREAKER ON ANY THREADED EXTERIOR OR INTERIOR <br />FAUCETS. <br />15. ALL WATER SHUT-OFF VALVES SHALL BE "BALL <br />LOCK" TYPE. PROVIDE SHUT-OFF VALVES AT EACH <br />TERMINATION POINT OF ASSOCIATED EQUIPMENT. <br />16. PROVIDE SEISMIC BRACING BASED ON <br />APPROPRIATE SEISMIC ZONE REQUIREMENTS PER <br />LOCAL AND NATIONAL CODES. CONTRACTOR'S <br />RESPONSIBILITY INCLUDES STRUCTURAL ENGINEER'S <br />CERTIFICATION ON DETAILS SUBMITTED FOR <br />PERMITTING. <br />E <br />C <br />me 0 <br />A <br />KVUC11�1, AKRHINZOAZO <br />WWW.BATESARCHITECTS.COM <br />TEL: 479.633.8165 <br />Copyright 2016 Bates & Associates, Architects <br />Drawings and Specifications as instruments of service are and shall remain <br />the property of the Architect. They are not to be used on other projects or <br />extensions to this project except by agreement in writing and with <br />appropriate compensation to the Architect. <br />Contractor is responsible for confirming and correlating dimensions at job <br />site; the Architect will not be responsible for construction means, methods, <br />techniques, sequences or procedures, or for safety precautions and <br />programs in connection with the project. <br />SITE/STORE #: <br />1037728 <br />I CONSTRUCTION MANAGER <br />CREIGHTON CONST. & MGMT <br />I 900 SW PINE ISLAND ROAD, SUITE 202, <br />CAPE CORAL, FL 33991 <br />DEVELOPER CONTACT <br />TENANT <br />7-ELEVEN INC. <br />1722 ROUTH ST. SUITE 1000 DALLAS, TX 75201 <br />DANIELTUBB <br />STRUCTURAL CONSULTANT <br />ARCH CONSULTING ENGINEERS <br />510 S CONGRESS SUITE B-100 AUSTIN, TX 78704 <br />JUSTIN BILLODEAU <br />MEP CONSULTANT <br />WALTER J. FITZGERALD, P.E. 24636 <br />2566 NEBRASKA AVE. APT 443 <br />PALM HARBOR, FL 34684 PH (813) 785-7526 <br />C� N <br />c N <br />p (D LLI <br />W Z) a� <br />z LO °6 rn <br />O °CL M Q M <br />>- L O LL. <br />� Cn z <br />z LU J O o Q <br />> 0 z -1 U <br />J-r-- O - W <br />W o f z <br />I` N = � U <br />_ (.D <br />W (o <br />I..f� O <br />U 0') <br />60 <br />_, <br />S OF X_ <br />�•O R 1 <br />(03 61A1110 <br />Architect Name - RYAN M FAUST <br />Architect Number - AR97905 <br />THE SEAL AND SIGNATURE APPLY ONLY TO THE DOCUMENT TO WHICH <br />THEY ARE AFFIXED AND WE EXPRESSLY DISCLAIM ANY RESPONSIBILITY FOR <br />ALL OTHER PLANS, SPECIFICATIONS, ESTIMATES, REPORTS OR OTHER <br />DOCUMENTS OR INSTRUMENTS RELATING TO OR INTENDED TO BE USED <br />FOR ANY PART OR PARTS OF THE PROJECT. <br />REVISIONS <br />NO. DATE DESCRIPTION <br />PROJECT NUMBER: 16-021 <br />RELEASE DATE: 03/31/2016 <br />DRAIN PIPING PLAN <br />RISER AND SCHEDULES <br />6 <br />5 4 3 2 1 <br />