Laserfiche WebLink
G <br />L 1l Ro�lOR ST <br />SunTrust Bank TAMPA BAY <br />HYRHILLS OFFICE <br />7809 Gall Boulevard <br />ZEPHERHILLS, FLORIDA <br />PROJECT NUMBER: <br />16-030 <br />Is,Robert Reid Weddin <br />k <br />1, <br />z <br />, <br />-0, 0 <br />Arch'itects & lanners <br />Li 4112 Cypress Street - Tampa, Florida 33607 - 813-879-6996 <br />r 612 South Military Trail - Deerfield Beach, Florida 33442 - 954-428-9361 <br />w <br />O <br />U E <br />0 <br />O <br />0 <br />0 <br />Q <br />I <br />0 <br />0 <br />co <br />i <br />to <br />>s <br />3 <br />SYMBOLS <br />ABBREVIATIONS <br />B <br />HOSE IBB <br />N <br />INCHES <br />o <br />NOT ALL <br />LISTED ARE USED IN THESE DRAWINGS ID <br />INSIDE DIAMETER <br />Q, <br />DOOR SYMBOL <br />13 DOOR NUMBER <br />AFF <br />ABOVE FINISHED FLOOR <br />INSUL <br />INSULATION <br />ACC <br />ACCESSIBLE <br />J-BOX <br />JUNCTION BOX <br />o <br />WINDOW SYMBOL <br />�WINDOW OR STOREFRONT ELEVATION <br />APC <br />ACOUSTICAL PANEL CEILING <br />LAM <br />LAMINATE <br />j <br />TYPE <br />ADJ <br />ADJUST, ADJUSTABLE <br />LAV <br />LAVATORY <br />AHU <br />AIR HANDLING UNIT <br />LTNG <br />LIGHTNING <br />° <br />D <br />PARTITION SYMBOL <br />PARTITION TYPE LETTER <br />ALT <br />ALTERNATE <br />LIN <br />LINEAR <br />U <br />ALUM <br />ALUMINUM <br />LF <br />LINEAR FEET <br />ROOM SYMBOL <br />CONFERENK- ROOM NAME <br />AB <br />ANCHOR BOLT <br />LLH <br />LONG LEG HORIZONTAL <br />U <br />ROOM _ ROOM NULBER <br />ANOD <br />ANODIZE <br />LLV <br />LONG LEG VERTICAL <br />_ <br />ASPH <br />ASPHALT <br />MFR <br />MANUFACTURER <br />ATM <br />AUTOMATIC TELLER MACHINE <br />MO <br />MASONRY OPENING <br />o <br />DETAIL SYMBOL <br />___(1 DETAIL LOCATION <br />BM <br />BEAM <br />MECH <br />MECHANICAL <br />SHEET NUMBER <br />BRIG <br />BEARING <br />MEMB <br />MEMBRANE <br />DIRECTION OF VIEW <br />BLW <br />BELOW <br />MTL <br />METAL <br />° <br />SECTION SYMBOL <br />SECTION LOCATION <br />BW <br />BOTH WAYS <br />MEZZ <br />MEZZANINE <br />BOT <br />BOTTOM <br />MIN <br />MINIMUM <br />a <br />SHEET NUMBER <br />BLDG <br />BUILDING <br />MR <br />MOISTURE RESISTANT <br />° <br />3 <br />BR <br />BALLISTIC -RESISTANT <br />MTD <br />MOUNTED <br />° <br />INTERIOR ELEVATION INDICATOR <br />A ELEVATION DIRECTION <br />CAB <br />CABINET <br />NOM <br />NOMINAL <br />DETAIL LOCATION <br />CIP <br />CAST -IN -PLACE <br />NIC <br />NOT IN CONTRACT <br />Ln <br />C <br />CLG <br />CEILING <br />NTS <br />NOT TO SCALE <br />0 <br />O <br />- <br />CTR <br />CENTER <br />OC <br />ON CENTER <br />0 <br />SHEET NUMBER <br />CL <br />CENTER LINE <br />OPP <br />OPPOSITE <br />o C <br />CT <br />CERAMIC TILE <br />OD <br />OUTSIDE DIAMETER <br />o <br />REVISION SYMBOL <br />ZL- REVISION ISSUE NUMBER <br />CLR <br />CLEAR <br />OFCI <br />OWNER FURNISHED, <br />0 <br />COL <br />COLUMN <br />CONTRACTOR INSTALLED <br />j <br />KEY NOTE SYMBOL <br />1=� KEY NOTE NUMBER <br />CMU <br />CONCRETE MASONRY UNIT <br />PTD <br />PAINTED <br />rn <br />= <br />CONIC <br />CONCRETE <br />P LAM <br />PLASTIC LAMINATE <br />CO <br />CONCRETE OPENING <br />PL R <br />PLATE <br />RENOVATION KEY NOTE SYMBOL <br />®- ACTION/KEY NOTE NUMBER <br />CONT <br />CONTINUOUS <br />PLWD <br />PLYWOOD <br />CJ <br />CONSTRUCTION JOINT <br />PREFAB <br />PREFABRICATED <br />N <br />ELEVATION MARK <br />DIA <br />DIAMETER <br />PT <br />PRESSURE TREATED <br />DW <br />DISHWASHER <br />QT <br />QUARRY TILE <br />co <br />DBL <br />DOUBLE <br />R <br />RADIUS <br />DS <br />DOWNSPOUT <br />RCP <br />REFLECTED CEILING PLAN <br />EA <br />EACH <br />REINF <br />REINFORCED <br />EW <br />EACH WAY <br />REQD <br />REQUIRED <br />o� <br />EWC <br />ELECTRIC WATER COOLER <br />RES <br />RESILIENT <br />0 <br />ELEV <br />ELEVATOR <br />RA <br />RETURN AIR <br />�I <br />EMER <br />EMERGENCY <br />REV <br />REVISION <br />B <br />EQ <br />EQUAL <br />RD <br />ROOF DRAIN <br />- <br />EQUIP <br />EQUIPMENT <br />RTU <br />ROOF TOP UNIT <br />EXIST <br />EXISTING <br />SHT <br />SHEET <br />c° <br />EXP <br />EXPANSION <br />SM <br />SHEET METAL <br />0 <br />EJ <br />EXPANSION JOINT <br />SIM <br />SIMILAR <br />i <br />EXTR <br />EXTERIOR <br />SC <br />SOLID CORE <br />6, <br />FWC <br />FABRIC WALLCOVERING <br />SF <br />SQUARE FEET <br />FT <br />FEET <br />SQ IN <br />SQUARE INCH <br />C3 <br />FIN <br />FINISH <br />SSTL <br />STAINLESS STEEL <br />FIN FLR <br />FINISH FLOOR <br />STD <br />STANDARD <br />FE <br />FIRE EXTINGUISHER <br />STL <br />STEEL <br />E <br />FEC <br />FIRE EXTINGUISHER CABINET <br />STRUCT <br />STRUCTURAL <br />co <br />FIR <br />FIRE RATED (RESISTANT) <br />TH <br />THICK <br />FLEX <br />FLEXIBLE <br />THRU <br />THROUGH <br />`V <br />FD <br />FLOOR DRAIN <br />T&B <br />TOP AND BOTTOM <br />FLUOR <br />FLUORESCENT <br />XFMR <br />TRANSFORMER <br />FURN <br />FURNITURE <br />T'P <br />TYPICAL <br />FV <br />FIELD VERIFY <br />UG <br />UNDERGROUND <br />> A <br />GA <br />GAGE <br />UNO <br />UNLESS NOTED OTHERWISE <br />° <br />z <br />GALV <br />GALVANIZED <br />VTR <br />VENT THROUGH ROOF <br />GYP <br />GYPSUM <br />VERT <br />VERTICAL <br />c° <br />GYP BD <br />GYPSUM BOARD <br />VCT <br />VINYL COMPOSITION TILE <br />N <br />H & V <br />HORIZONTAL & VERTICAL <br />VWC <br />VINYL WALL COVERING <br />HC <br />HOLLOW CORE <br />WCO <br />WALL CLEANOUT <br />HCW <br />HOLLOW CORE WOOD DOOR <br />WC <br />WATER CLOSET <br />HM <br />HOLLOW METAL <br />WKO <br />WEB KNOCK -OUT <br />° <br />HORIZ <br />HORIZONTAL <br />WD <br />WOOD <br />1 <br />2 <br />3 <br />4 <br />THE DESIGN AND CONCEPTS DEPICTED <br />HEREWITH ARE THE SOLE PROPERTY OF SUNTRUST BANKS, INC. NO <br />REPRODUCTION, REVISIONS OR <br />REUSE OF THIS DRAWING IS AUTHORIZED WITHOUT SPECIFIC WRITTEN PERMISSION. ALL RIGHTS <br />RESERVED. <br />LOCATION <br />❑ede city <br />Torih <br />yCID <br />oodc•cny <br />m <br />St Leo <br />ce <br />N <br />m <br />� <br />n <br />e� <br />fiichlond <br />,a <br />sis ,ry <br />Cypress <br />Creek Flood <br />' <br />Detmlion,AreS <br />SEE <br />`' zophyrnitls <br />BELOW ® o h <br />lrJe sley <br />Chapel South <br />_ <br />Zephyrhills Zephythllla <br />`J <br />sa <br />• Skydive City/Z-Hi11$ <br />ZePhprhtlls <br />south <br />r <br />r <br />utlItItq <br />�i <br />Kozy Acres N <br />s <br />Kostclk Rd 'r'_ Otis i <br />K( ssik Rd Kot;sik Rd ro <br />Lowe's Horne <br />0 o Improvement <br />Zephyr Commons a a Staples <br />�i <br />N <br />CcreyL?;,l e n PublixSuperMarket'- <br />Gill Ave e Vf ad" <br />The UPS Store <br />SITE <br />Lilly Bea Ave m <br />Walmort Supercenter e <br />Now 11oI <br />a Qid Chili's Grill &Bar vi <br />u <br />lgndlsve - <br />Zro <br />Voilheide t)r � <br />Z I_oreo,7w F <br />n <br />y m <br />r- Pumpkin Ave z <br />o d <br />Sbuthslde Ur - <br />a <br />Pretty Pond Rd Pretty Pond Rd Preliy <br />Oak Run Apartments Sonic Drive-in n a <br />a Tractor Supply CC z <br />Laurel Hammock Of <br />Hobby Lobby a <br />Alpl`,4i <br />Medical Arts Ct rt.. Ponora Broid Y <br />OWNER f CLIENT <br />LINCOLN HARRIS/SunTrust ACCOUNT <br />4350 CONGRESS ST. <br />SUITE 175 <br />CHARLOTTE, NORTH CAROLINA 28209 <br />(704) 390-5215 FAX: (000) 000-0000 <br />CONTACT: BOB HOAK <br />CONSULTANTS <br />CIVIL ENGINEER <br />CPH, INC. <br />1031-C WEST 23RD STREET <br />PANAMA CITY, FLORIDA 32405 <br />(850) 563-1490 FAX: (850) 563-1495 <br />CONTACT: JASON TOOLE <br />STRUCTURAL ENGINEER <br />McCARTHY & ASSOCIATES, INC. <br />2555 NURSERY RD. - SUITE 101 <br />CLEARWATER, FL. 34624 <br />(727) 536-8772 FAX: (727) 538-9125 <br />CONTACT: MIKE McCARTHY <br />CODE COMPLIANCE <br />MECHANICAL ENGINEER <br />ADVANCED SYSTEMS ENGINEERING INC. <br />13555 AUTOMOBILE BLVD. SUITE 330 <br />CLEARWATER, FL. 33762 <br />(727) 540-9396 FAX: (727) 540-9376 <br />CONTACT: JOHN WOOD <br />ELECTRICAL ENGINEER <br />VOLTAIR <br />220 WEST 7TH AVENUE, SUITE 210 <br />TAMPA, FLORIDA 33602 <br />(813) 867-4889 FAX: (813) 867-4566 <br />CONTACT: DAVID FREEMAN <br />BANK EQUIPMENT <br />DIEBOLD INC. <br />43 SKYLINE DRIVE SUITE 1051 <br />LAKE MARY, FLORIDA 32746 <br />(407) 549-2058 <br />CONTACT: BILL LAWRENCE <br />APPLICABLE CODES <br />FLORIDA BUILDING CODE FIFTH EDITION <br />FLORIDA FIRE PREVENTION CODE, <br />FIFTH EDITION <br />BUILDING DATA <br />OCCUPANCY CLASSIFICATION: <br />GROUP B - BUSINESS <br />CONSTRUCTION CLASSIFICATION: <br />TYPE V-B <br />UN-SPRINKLERED <br />BUILDING STORIES: <br />1 <br />BUILDING HEIGHT: <br />MAX. ALLOWED: 40'-0" <br />PROVIDED: 20'-3 1/2" <br />BUILDING AREA: <br />3,142 SF GROSS <br />56 SF UNDER ROOF <br />OCCUPANT LOAD <br />3,142 s.f. / 100 S.F./PERSON <br />= 32 PERSONS <br />REQUIRED EXITS: <br />MIN. REQUIRED: 2 <br />PROVIDED: 2 <br />EGRESS CAPACITY: <br />MIN. REQUIRED: <br />PROVIDED: <br />HORIZONTAL: <br />32 PERSONS x .2" = 6.4" <br />108" TOTAL EXITS <br />36" MINIMUM EGRESS REQUIRED <br />TRAVEL DISTANCE: <br />MAX. ALLOWED: 300' <br />PROVIDED: 85'-3" <br />PLUMBING REQUIREMENTS <br />MEN <br />WOMEN <br />REQUIRED PROVIDED <br />REQUIRED PROVIDED <br />WATER CLOSETS: <br />1 1 <br />1 1 <br />LAVATORIES: <br />1 1 <br />1 1 <br />DRINKING FOUNTAINS: <br />1 2 <br />SERVICE SINKS: <br />0 1 <br />CODE COMPLIANCE APPROVED PRODUCTS LIST <br />PRODUCT SUBCATEGORY <br />PRODUCT <br />NOA <br />CATEGORY <br />DOORS <br />SWINGING <br />STEELCRAFT SERIES "H" SINGLE FLUSH <br />NOA 15-0930.03 <br />OUTSWING COMMERCIAL STEEL DOOR W/ <br />MORTISE LOCKSET W/ DEAD BOLTS <br />DOORS <br />SWINGING <br />STEELCRAFT SERIES "H" SINGLE FLUSH <br />NOA 15-0427.05 <br />OUTSWING COMMERCIAL STEEL DOOR W/ <br />MORTISE LOCK W/ DEAD BOLT <br />ROOFING <br />SINGLE PLY <br />FIRESTONE ULTRA PLY TPO <br />NOA 13-1212.05 <br />ROOF SYSTEMS <br />ROOFING <br />ROOFING <br />METAL -ERA ROOF EDGE <br />NOA 13-0419.03 <br />FASTENERS <br />TERMINATION SYSTEM <br />DOORS <br />SWINGING <br />OLDCASTLE ?? <br />NOA ?? <br />L--J <br />CIO I SCALE: 1/16 = 1`-0" <br />DRAWING INDEX <br />m <br />� <br />a w <br />N <br />LU <br />Cn N <br />H NAM <br />CD <br />oN <br />A00.00 <br />COVER PAGE, PROJECT INFORMATION AND <br />• <br />DRAWING INDEX <br />A00.01 <br />RESPONSIBILITY MATRIX <br />• <br />A00.34A <br />FINISH SCHEDULE 1 <br />• <br />A00.348 <br />EQUIPMENT & MILLWORK SCHEDULES 1 <br />• <br />A02.01 I <br />CONSTRUCTION PLAN <br />• <br />A02.02 <br />ROOF PLAN AND DETAILS <br />• <br />A04.01 <br />REFLECTED CEILING, FURNITURE, AND <br />FINISH PLANS <br />• <br />A09.01 <br />EXTERIOR ELEVATIONS & DOOR <br />SCHEDULE <br />• <br />A09.20 <br />WALL SECTIONS <br />• <br />A11.01 <br />INTERIOR ELEVATIONS <br />• <br />Al2.03 <br />MILLWORK DETAILS <br />• <br />S01.00 <br />I GENERAL NOTES <br />• <br />S01.01 <br />GENERAL NOTES <br />• <br />S01.02 <br />WIND TABLES <br />• <br />S02.01 <br />FOUNDATION PLAN <br />• <br />S02.02 <br />ROOF FRAMING PLAN <br />• <br />S03.00 <br />FOUNDATION DETAILS <br />• <br />S03.01 <br />FOUNDATION DETAILS <br />• <br />S05.00 <br />FRAMING DETAILS <br />• <br />S05.01 <br />FRAMING DETAILS <br />• <br />S05.02 <br />FRAMING DETAILS <br />• <br />M-0 <br />MECHANICAL SPECIFICATIONS & LEGEND <br />• <br />M-1.1 <br />MECHANICAL DESIGN <br />• <br />M-1.2 <br />MECHANICAL ROOF PLAN <br />• <br />M-2.1 <br />MECHANICAL DETAILS & SCHEDULES <br />• <br />M-2.2 <br />MECHANICAL DETAILS & SCHEDULES <br />• <br />M-2.3 <br />FAN COIL UNIT WIRING DIAGRAM <br />• <br />P-0 PLUMBING SPECIFICATIONS • <br />P1.1 PLUMBING PLAN: DOMESTIC WATER • <br />P1.2 PLUMBING PLAN: GRAVITY DRAINAGE • <br />P-2 PLUMBING DETAILS & SCHEDULES • <br />E-0 <br />ELECTRICAL LEGEND <br />• <br />E-2 <br />ELECTRICAL SITE PLAN <br />• <br />E-2A <br />ELECTRICAL PHOTOMETRIC SITE PLAN <br />• <br />E-3 <br />LIGHTING PLAN <br />• <br />E-4 <br />POWER PLAN <br />• <br />E-5 <br />POWER RISER DIAGRAM AND SCHEDULES <br />• <br />E-6 <br />WIRING DIAGRAM <br />• <br />CIVIL (REFERENCE ONLY) <br />TOTAL SHEETS PER SET <br />37 <br />L_-J <br />10 LI F L J/1F L I I F" L.J1I V- <br />SCALE: 1/16" = 1'-0" <br />I 1 ` <br />2 �T ; <br />fell <br />F-� <br />SIVA <br />ALL WORK SNAIL, COMPLY WITH <br />PREVAILING CODES <br />FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, AND <br />���l��� CITY OF ZEPHYRHILLS ORDINANCES <br />% <br />REVIEW DATEV621 1 <br />CITY OF ZEPHYRHI S <br />PLAN EXAMINER <br />LIFE SAFETY LEGEND <br />0 <br />FIRE EXTINGUISHER - 75' MAX. TRAVEL <br />DISTANCE <br />41-60BC UL RATING <br />-PATH OF TRAVEL & DISTANCE <br />® <br />EXIT LIGHT <br />' <br />EXIT <br />® <br />EXIT SIGN WITH BRAILLE <br />® <br />I <br />EMERGENCY EXIT SIGN WITH BRAILLE <br />I <br />I <br />_J <br />N <br />COVER PAGE, PROJECT INFORMATION AND DRAWINS INDEX <br />L' <br />CU <br />fN <br />v L�: N <br />Cam" <br />�, <br />C � <br />51 <br />Y <br />s <br />U <br />n <br />Co M M <br />� N N <br />O) V '- <br />CD 4 o <br />_ <br />00 N Q <br />M G <br />V/ <br />M � <br />n� <br />OC <br />M <br />W <br />�• � <br />L <br />p U C <br />A+ <br />a7 <br />E°' <br />W <br />CIO <br />r <br />'}j <br />(%i <br />iFa..N <br />w <br />r O . <br />i <br />4 <br />O <br />L)ry <br />N <br />i <br />Q <br />' ,� <br />C <br />O <br />CD <br />•� <br />µ <br />O <br />a� <br />I <br />m <br />a <br />W . <br />•a <br />U <br />E <br />C:r_ <br />0 <br />L� <br />V <br />Q <br />E <br />O <br />5 <br />++ <br />= <br />m <br />C� _ <br />_ <br />CD <br />ck� <br />w <br />Cn <br />N <br />r- <br />0 <br />0 <br />a <br />_ <br />U <br />.; <br />, <br />as <br />0 <br />"D <br />t_ <br />Pr <br />W <br />•I <br />rl <br />o <br />M <br />U <br />� <br />CO <br />N <br />cp <br />_ <br />N <br />b <br />sheet no. <br />AOO.00 <br />