Laserfiche WebLink
H <br />GI <br />FI <br />EI <br />E <br />n_ <br />0 <br />i A <br />0 <br />a <br />GENERAL NOTES CONT. <br />MASONRY CONT. <br />20. PLACE MASONRY IN RUNNING BOND WITH 3/8 MORTAR JOINTS. PROVIDE COMPLETE <br />COVERAGE FACE SHELL MORTAR BEDDING, HORIZONTAL AND VERTICAL. FULLY MORTAR <br />WEBS IN ALL COURSES OF PIERS, COLUMNS, AND PILASTERS AND ADJACENT TO <br />GROUTED CELLS. <br />21. SEE DRAWINGS FOR MASONRY CONTROL JOINT LOCATIONS. SPACE AT 26'-0" O.C. <br />UNLESS NOTED OTHERWISE, <br />22. SUBMITTALS: <br />A) SUBMIT PROPOSED GROUT MIX DESIGN PRIOR TO CONSTRUCTION. <br />B) SUBMIT PROPOSED MORTAR MIX DESIGN PRIOR TO CONSTRUCTION. <br />C) SUBMIT DETAILED SHOP DRAWINGS OF REINFORCING BARS SHOWING NUMBER, <br />SIZE, AND LOCATION. INCLUDE BAR LISTS AND BEND DIAGRAMS. INCLUDE ALL <br />REQUIRED DIMENSIONS AND ELEVATIONS. <br />D) SUBMIT COMPRESSIVE STRENGTH TESTS OF PROPOSED MASONRY UNITS PRIOR <br />TO CONSTRUCTION. MASONRY UNITS ARE TO BE TESTED IN ACCORDANCE WITH <br />ASTM Cl 40. <br />23. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM THE FOLLOWING <br />TESTS: <br />A) SAMPLE AND TEST GROUT IN ACCORDANCE WITH ASTM C1019 FOR EACH 5000 <br />SQ. FT. OF MASONRY. <br />B) SLUMP TESTS - ASTM C143. <br />C) MASONRY PRISM TEST IN ACCORDANCE WITH ASTM C1314. PROVIDE ONE SET <br />OF 3 PRISMS PRIOR TO CONSTRUCTION AND DURING CONSTRUCTION FOR EACH <br />5000 SQ. FT. OF WALL. <br />24. PROVIDE 8" DEEP PRECAST REINFORCED CONCRETE LINTELS OVER ALL MASONRY <br />OPENINGS NOT SHOWN TO HAVE A STRUCTURAL BEAM. MINIMUM END BEARING = 8". <br />LINTEL WIDTH TO MATCH MASONRY WIDTH. <br />25. TOPS OF PARTIALLY CONSTRUCTED WALLS SHALL BE COVERED WITH VISQUEEN <br />WHENEVER RAIN OCCURS AND AT THE END OF THE WORK DAY. <br />DRILL -IN BOLTS, SCREWS AND DOWELS <br />1. ADHESIVE DOWELING RODS/BOLTS SHALL BE CARBON STEEL THREADED ROD <br />CONFORMING TO ISO 898 5.8 WITH A MINIMUM TENSILE STRENGTH OF 72.5 KSI <br />(50OMPa) AND A MINIMUM YIELD OF 58 KSI 40OMPa). THREADED RODS WITH NUTS <br />AND WASHERS INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />PROVIDE HILTI HY 200 SAFE SET (ESR 3187) OR RE 500 SD (ESR 2322) ANCHORS <br />BY HILTI OR EQUAL (SIMPSON SET-XP, ATC ULTRABOND 365CC). <br />2. ANCHORING ADHESIVE SHALL BE A TWO -COMPONENT SYSTEM SUPPLIED IN <br />MANUFACTURER'S STANDARD SIDE -BY -SIDE FOIL PACKAGE AND DISPENSED THROUGH <br />A STATIC -MIXING NOZZLE SUPPLIED BY THE MANUFACTURER. ADHESIVE SHALL BE <br />TESTED AND APPROVED TO MEET THE MINIMUM REQUIREMENTS OF ACI 355.4 FOR <br />CRACKED AND UNCRACKED CONCRETE RECOGNITION. <br />3. DRILL -IN REBAR DOWELS SHALL BE SET USING A TWO-PART ADHESIVE AS DESCRIBED <br />ABOVE. <br />4. EXPANSION BOLTS SHALL BE HILTI KB TZ (ESR 1917) OR EQUAL. BOLT SHALL MEET <br />DUCTILITY REQUIREMENTS OF ACI 318 SECTION D1. <br />5. EXPANSION BOLTS SHALL HAVE CARBON STEEL ANCHOR BODY AND NUT AND WASHER <br />SHALL BE ELECTROPLATED ZINC COATING CONFORMING TO ASTM B633 TO A MINIMUM <br />OF 5pM. THE STAINLESS STEEL ANCHOR BODY, NUT AND WASHER, AND EXPANSION <br />SLEEVE SHALL CONFORM TO TYPE 316 STAINLESS STEEL. EXPANSION ANCHORS SHALL <br />MEET THE MINIMUM REQUIREMENTS OF ACI 355.2 FOR CRACKED AND UNCRACKED <br />CONCRETE. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />6. MASONRY SCREWS SHALL BE 1/4" DIAMETER WITH 1-5/8" MINIMUM EMBEDMENT <br />INSTALLED IN DRILLED HOLES USING AN APPROPRIATE BIT DIAMETER. <br />7. SCREWS SHALL HAVE A BODY MADE OF CARBON STEEL AND SHALL BE HEAT TREATED <br />AND SHALL HAVE 8NM ZINC COATING IN ACORDANCE WITH EN ISO 4042. PROVIDE <br />HUS EZ (ESR 3027) SCREWS BY HILTI OR EQUAL. <br />8. HEAVY-DUTY CONCRETE AND MASONRY SCREWS SHALL BE TESTED AND APPROVED TO <br />MEET THE MINIMUM REQUIREMENTS OF ACI 355.2. HILTI KWICK HUS EZ (ESR-3027 <br />FOR CONCRETE, ESR-3056 FOR GROUT FILLED MASONRY). HEAVY DUTY SCREWS BY <br />HILTI OR EQUAL. <br />9. THE CONTRACTOR SHALL ARRANGE FOR AN ANCHOR MANUFACTURER'S <br />REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THE <br />ANCHORING PRODUCTS SPECIFIED. MCCARTHY AND ASSOCIATES TO RECEIVE <br />DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO ARE <br />TO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLATION. <br />STRUCTURAL STEEL <br />1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATION FOR BUILDINGS", <br />LATEST EDITION. <br />2. WELDED CONNECTIONS SHALL CONFORM TO THE LATEST REVISED CODE OF THE <br />AMERICAN WELDING SOCIETY, AWS D1.1. ALL WELDING SHALL BE PERFORMED USING <br />E70XX, LOW HYDROGEN ELECTRODES. ELECTRODES ARE TO BE PROTECTED FROM <br />MOISTURE. <br />3. CONNECTIONS TO SHEAR PLATE FRAMED BEAM CONNECTION PER AISC UNLESS NOTED <br />OTHERWISE. ALL BOLTS TO BE 3/4" DIAMETER UNLESS NOTED OTHERWISE. SHOP <br />CONNECTIONS MAY BE WELDED OR BOLTED. WELDS ARE TO BE EQUAL IN STRENGTH <br />TO BOLTS. ALL FIELD CONNECTIONS ARE TO BE BOLTED WITH ASTM A325N OR A490 <br />BOLTS (BEARING TYPE BOLTS WITH THREADS IN THE SHEAR PLANE) INCLUDING <br />SUITABLE NUTS AND PLAIN HARDENED WASHERS. ALL BOLTS SHALL BE TIGHTENED <br />SNUG TIGHT UNLESS OTHERWISE NOTED. DESIGN CONNECTIONS FOR EITHER THE <br />o ee <br />SHEAR SHOWN ON THE DRAWINGS, A = N INDICATED S b K AT ENDS OF MEMBER OR <br />55% OF THE MAXIMUM LOAD(IN KIP) LISTED IN THE TABLES FOR "MINIMUM TOTAL <br />FACTORED UNIFORM LOADS IN KIPS FOR BRACED, SIMPLE SPAN BEAMS BENT ABOUT <br />THE STRONG AXIS" OF THE LATEST EDITION OF THE AISC "MANUAL OF STEEL <br />CONSTRUCTION". <br />4. SIZE AND USE OF HOLES: SEE AISC TABLE J3.3. <br />A) LARGER HOLES ARE PERMITTED IN STANDARD COLUMN BASE PLATES. MAXIMUM <br />HOLE DIAMETER = BOLT DIAMETER + 3/8". HARDENED WASHERS, TO COVER <br />THE LARGER HOLE, SHALL BE PROVIDED. <br />B) LARGER HOLES ARE NOT PERMITTED IN WIND FRAME COLUMN BASE PLATES. <br />MAXIMUM HOLE DIAMETER = BOLT DIAMETER + 1/16". <br />C) SLOTTED HOLES: A PLATE WASHERS OR A CONTINUOUS BAR WITHSTANDARD <br />HOLES, HAVING A SIZE SUFFICIENT TO COMPLETELY COVER THE SLOT AFTER <br />INSTALLATION, AND A MIN. OF 5/16" THICK SHALL BE PROVIDED. TACK WELD <br />NUT TO BOLT AFTER ERECTION. <br />5. STEEL BEAMS SHALL BE FABRICATED WITH THE NATURAL CAMBER (WITHIN THE MILL <br />TOLERANCE) LOCATED ABOVE THE HORIZONTAL CENTERLINE BETWEEN THE END <br />CONNECTIONS. <br />6. VERIFY THE EXACT SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS FOR <br />MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR PRIOR TO FABRICATION <br />OF MATERIALS. <br />7. SHOP PRIME STEEL SURFACES EXCEPT THE FOLLOWING: <br />A) SURFACES EMBEDDED IN CONCRETE OR MORTAR. EXTEND PRIMING OF PARTIALLY <br />EMBEDDED MEMBERS TO A DEPTH OF 2 INCHES. <br />B) SURFACES TO BE FIELD WELDED. <br />C) SURFACES TO BE HIGH -STRENGTH BOLTED WITH SLIP -CRITICAL CONNECTIONS. <br />D) SURFACES TO RECEIVE SPRAYED FIRE -RESISTIVE MATERIALS. <br />E) GALVANIZED SURFACES. <br />8. SURFACE PREPARATION: CLEAN SURFACES TO BE PAINTED. REMOVE LOOSE RUST <br />AND MILL SCALE AND SPATTER, SLAG, OR FLUX DEPOSITS. PREPARE SURFACES <br />ACCORDING TO THE FOLLOWING SPECIFICATIONS AND STANDARDS. <br />9. PRIMING: IMMEDIATELY AFTER SURFACE PREPARATION, APPLY PRIMER ACCORDING TO <br />MANUFACTURER'S WRITTEN INSTRUCTIONS AND AT RATE RECOMMENDED BY SSPC TO <br />PROVIDE A DRY FILM THICKNESS OF NOT LESS THAN 1.5 MILS. USE PRIMING <br />METHODS THAT RESULT IN FULL COVERAGE OF JOINTS, CORNERS, EDGES, AND <br />EXPOSED SURFACES. <br />A) STRIPE PAINT CORNERS, CREVICES, BOLTS, WELDS, AND SHARP EDGES. <br />B) APPLY TWO COATS OF SHOP PAINT TO INACCESSIBLE SURFACES AFTER <br />ASSEMBLY OR ERECTION. CHANGE COLOR OF SECOND COAT TO DISTINGUISH IT <br />FROM FIRST. <br />10. PRIME AND PAINT ALL FIELD WELDS AFTER INSPECTION. <br />11. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM THE FOLLOWING <br />TESTS. <br />A) VISUALLY INSPECT ALL STEEL MEMBERS AND CONNECTIONS. <br />B) TEST 50 PERCENT OF FULL PENETRATION WELDS. <br />12. ONE COPY OF ALL TEST REPORTS SHALL BE SENT DIRECTLY TO OWNER, ARCHITECT, <br />STRUCTURAL ENGINEER, AND GENERAL CONTRACTOR. <br />13. STEEL SHALL CONFORM TO: <br />WIDE FLANGE (WF)(WT) ------ ASTM A992 (50 KSI) <br />SHAPES (L, C, MC) --------- ASTM A36 <br />HOLLOW STRUCTURAL SECTIONS (HSS)--- ASTM A500 GRADE B (RECTANGULAR 46 <br />KSI; ROUND 42 KSI) <br />ANCHOR RODS --------------- ASTM F1554 (55 KSI W/S1 SUPPLEMENT) <br />ANCHOR BOLTS -------------- ASTM A307 <br />FRAMING BOLTS ------------- ASTM A325N OR A490N <br />SHEAR STUDS --------------- ASTM A108 <br />WELDING ELECTRODES -------- E70XX <br />14, FASTENERS AND MATERIALS USED FOR WELDING OR OTHERWISE SECURING <br />COMPONENTS ONE TO ANOTHER SHALL BE OF DOMESTIC (USA MADE) MANUFACTURE. <br />SIMILARLY, ALL MATERIALS USED IN THE MANUFACTURING PROCESS SHALL BE FROM A <br />DOMESTIC SOURCE. <br />15. OPENINGS THROUGH STEEL BEAMS SHALL BE PROVIDED AS DETAILED ON THE <br />DRAWINGS. ALL SUCH OPENINGS SHALL BE MACHINE CUT IN THE SHOP. ALL <br />RECTANGULAR OPENINGS SHALL HAVE A CORNER RADIUS OF 2 TIMES THE WEB <br />THICKNESS, 1 /2" MINIMUM. <br />16. SHOP AND FIELD WELDS SHALL BE DONE BY A.W.S. CERTIFIED WELDERS. PROVIDE <br />CURRENT CERTIFICATES UPON REQUEST. <br />17. NO SPLICES SHALL BE PERMITTED IN ANY STRUCTURAL STEEL MEMBER UNLESS <br />SHOWN ON APPROVED SHOP DRAWINGS. <br />18. STEEL STAIRS AND/OR LADDERS SHALL BE DESIGNED FOR 100 PSF LIVE LOAD BY A <br />LICENSED DELEGATED ENGINEER, WHO SHALL SUBMIT SIGNED AND SEALED SHOP <br />DRAWINGS. SHOP DRAWINGS SHALL SPECIFY ALL DESIGN LOADS. <br />1 1 2 1 3 4 5 <br />THE DESIGN AND CONCEPTS DEPICTED HEREWITH ARE THE SOLE PROPERTY OF ROBERT REID WEDDING ARCHITECTS & PLANNERS, AIA, INC. <br />NO REPRODUCTION, REVISIONS OR REUSE OF THIS DRAWING IS AUTHORIZED WITHOUT SPECIFIC WRITTEN PERMISSION. ALL RIGHTS RESERVED. <br />19. SUBMITTALS: CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS SHOWING ALL <br />STRUCTURAL STEEL LAYOUTS AND DETAILS, SIZES OF MEMBERS, TYPE OF STEEL, <br />CONNECTION DETAILS, WELDS, BOLTS, ETC., AS REQUIRED TO FABRICATE AND ERECT <br />ALL STRUCTURAL STEEL FRAMING. ALL CONNECTIONS NOT SHOWN ON THE <br />STRUCTURAL DRAWINGS SHALL BE DESIGNED BY THE DETAILER AND SUBMITTED ON <br />SHOP DRAWINGS, SIGNED AND SEALED BY A REGISTERED FLORIDA DELEGATED <br />ENGINEER. <br />20. NON -SHRINK GROUT SHALL BE: NONMETALLIC SHRINKAGE -RESISTANT GROUT, <br />PREMIXED, NON -CORROSIVE, NON -STAINING PRODUCT CONTAINING SELECTED SILICA <br />SANDS, PORTLAND CEMENT, SHRINKAGE COMPENSATING AGENTS, PLASTICIZING AND <br />WATER -REDUCING AGENTS, COMPLYING WITH CRD-C621, CORPS OF ENGINEERS. <br />21. IF NOT SPECIFIED ON THE DRAWINGS, THE THROAT SIZE OF ANY FILLET WELD SHALL <br />BE EQUAL TO 1/16" LESS THAN THE THINNEST CONNECTION COMPONENT. <br />22. NO FIELD WELDING OF GALVANIZED MEMBERS IS PERMITTED. <br />23. MINIMUM EMBEDMENT DEPTH OF ANCHOR BOLTS 3" FROM BOTTOM OF FOOTING. <br />24. ERECTION <br />A) BEFORE ERECTION, THE CONTRACTOR IS TO REMOVE ALL MUD, DIRT OR OTHER <br />FOREIGN MATTER, WHICH ACCUMULATES DURING HANDLING AND STORAGE. <br />B) DRIFTING TO ENLARGE UNFAIR HOLES WILL NOT BE PERMITTED. DRILL SUCH <br />HOLES TO ACCOMMODATE THE NEXT LARGER SIZE FASTENER, WHERE POSSIBLE. <br />C) AFTER ERECTION, CLEAN FIELD WELDS, BOLTED CONNECTIONS, AND ABRADED <br />AREAS WHERE SHOP COAT HAS BEEN DAMAGED. SPOT AND PRIME AREAS USING <br />SAME MATERIAL AS SHOP COAT. <br />D) SET ALL MEMBERS SO THAT, IN THEIR FINAL LOCATION, LEVEL, PLUMBNESS AND <br />ALIGNMENT ARE WITHIN THE TOLERANCES PRESCRIBED BY AISC CODE. <br />E) DOUBLE CONNECTIONS THROUGH COLUMN WEBS OR AT BEAMS THAT FRAME <br />OVER THE TOPS OF COLUMNS MUST BE DESIGNED TO HAVE AT LEAST ONE <br />INSTALLED BOLT REMAIN IN PLACE TO SUPPORT THE FIRST BEAM WHILE THE <br />SECOND BEAM IS BEING ERECTED. ALTERNATIVELY, THE FABRICATOR MUST <br />SUPPLY A SEAT OR EQUIVALENT DEVICE WITH A MEANS OF POSITIVE <br />ATTACHMENT TO SUPPORT THE FIRST BEAM WHILE THE SECOND BEAM IS BEING <br />ERECTED. <br />OPEN WEB STEEL JOISTS <br />1. STEEL JOIST MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE. <br />2. STEEL JOISTS SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OF <br />THE AISC STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS K SERIES AND <br />OSHA STEEL ERECTION STANDARD. <br />3. JOISTS AND ALL ACCESSORIES SHALL BE DESIGNED BY A LICENSED DELEGATED <br />ENGINEER WHO SHALL PREPARE DESIGN CALCULATIONS AND SUPERVISE THE <br />PREPARATION OF SHOP DRAWINGS. <br />4. C D WE U VERIFY THE EXACT LOCATION AN WEIGHT OF ALL MECHANICAL EQUIPMENT WITH THE <br />Q <br />MECHANICAL CONTRACTOR PRIOR TO FABRICATION OF JOISTS. <br />5. ALL HANGERS TO SUPPORT MECHANICAL EQUIPMENT, ETC., TO BE SUPPORTED BY <br />THE TOP OR BOTTOM CHORD OF JOISTS SHALL BE LOCATED AT THE PANEL POINT OF <br />THE JOIST. IF HANGERS MUST BE LOCATED IN BETWEEN PANEL POINTS, PROVIDE <br />JOIST STIFFENER AS INDICATED IN DETAILS, ALL HANGERS TO BE LOCATED AT THE <br />CENTERLINE OF THE BOTTOM CHORD MEMBER. <br />6. NO MODIFICATION THAT AFFECTS THE STRENGTH OF A STEEL JOIST SHALL BE MADE <br />WITHOUT THE APPROVAL OF THE DELEGATED ENGINEER. <br />7. DELEGATED ENGINEER SHALL DESIGN JOISTS AND BRIDGING FOR GRAVITY LOADS AND <br />WIND LOAD UPLIFT PRESSURES INDICATED ON THE DRAWINGS. <br />8. JOIST BRIDGING SHALL BE FURNISHED AND INSTALLED TO MEET THE DESIGN AND <br />SPACING REQUIREMENTS OF THE SJI STANDARD SPECIFICATIONS. ALL BRIDGING AND <br />BRIDGING ANCHORS SHALL BE COMPLETELY INSTALLED BEFORE CONSTRUCTION LOADS <br />ARE PLACED ON THE JOISTS. <br />9. WHERE COLUMNS ARE NOT FRAMED IN AT LEAST TWO DIRECTIONS WITH SOLID WEB <br />BEAMS, A STEEL JOIST SHALL BE FIELD -BOLTED AT THE COLUMN TO PROVIDE <br />LATERAL STABILITY DURING ERECTION. <br />10. A 6"X6" MINIMUM VERTICAL STABILIZER PLATE TO RECEIVE THE JOIST BOTTOM CHORD <br />MUST BE PROVIDED AT COLUMNS. THE STABILIZER PLATE MUST HAVE A 13/16 INCH <br />HOLE FOR THE ATTACHMENT OF GUYING OR PLUMBING CABLES. <br />11. JOISTS AND ACCESSORIES SHALL HAVE ONE SHOP COAT OF PAINT MEETING THE <br />MINIMUM PERFORMANCE REQUIREMENTS OF THE LATEST SJI SPECIFICATIONS. SEE <br />ARCHITECT FOR PREFERRED COLOR. <br />12. SEE PLAN FOR ANY CONCENTRATED LOADS OR UNUSUAL CONDITIONS. ALL JOISTS <br />SUBJECT TO SPECIAL LOADS OR CONDITIONS SHALL BE CONSIDERED "SPECIAL <br />JOISTS", (SP). <br />13. CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS SHOWING JOISTS, BRIDGING, <br />AND ALL CONNECTIONS. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY THE <br />DELEGATED ENGINEER. <br />14. THE DELEGATED ENGINEER MUST BE PROVIDED WITH A COPY OF THESE DRAWINGS <br />AND SPECIFICATIONS. <br />15. PROVIDE ONE ROW UPLIFT BRIDGING AT THE FIRST PANEL POINT FROM EACH <br />SUPPORT. <br />16. DURING THE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL PROVIDE MEANS FOR <br />ADEQUATE DISTRIBUTION OF CONCENTRATED LOADS SO THAT THE CARRYING CAPACITY <br />OF ANY JOIST IS NOT EXCEEDED. <br />17. ONE END OF ALL JOISTS SHALL BE ATTACHED TO ITS SUPPORT IN ACCORDANCE WITH <br />SJI SPECIFICATIONS BEFORE ALLOWING THE WEIGHT OF AN ERECTOR ON THE JOISTS. <br />18. SEE STANDARD JOIST SPECIFICATIONS FOR CAMBER REQUIREMENTS. <br />19. SUBMIT COMPLETE SHOP DRAWINGS FOR ALL JOISTS AND ACCESSORIES, AND A <br />LETTER, SIGNED AND SEALED BY THE DELEGATED ENGINEER, CONFIRMING COMPLIANCE <br />WITH THE DESIGN CRITERIA AND ALL APPLICABLE CODES. <br />METAL DECKING <br />1. METAL DECK WORK SHALL CONFORM TO THE REQUIREMENTS OF THE STEEL DECK <br />INSTITUTE. <br />2. METAL ROOF DECK SHALL BE 1 1 /2" DEEP, 22 GA., WIDE RIB TYPE B AND <br />GALVANIZED. (VULCRAFT 1.51322 OR EQUIVALENT.) <br />3. FASTEN ROOF DECK WITH #12 TEK SCREWS AT EACH SUPPORT PER 36" WIDTH AND <br />#12 TEK SCREWS AT MIDSPAN OF SIDELAPS AS INDICATED ON PLANS. <br />4. MINIMUM FASTENING AT BUILDING PERIMETER OF DECK SHALL BE 5/8" DIAMETER <br />PUDDLE WELDS AT 6" O.C. <br />5. METAL DECK AND SHEET METAL COATING DESIGNATION G60. <br />6. INSTALL ALL DECKING 3 SPAN CONTINUOUS. <br />7. USE WELD WASHERS FOR ALL DECKING 24 GA. AND THINNER. <br />8. DO NOT HANG OR ATTACH DUCTWORK, CONDUIT, PIPING, EQUIPMENT, CEILINGS, ETC. <br />FROM METAL DECKING. <br />9. ROOF DECK OPENINGS 12" DIAMETER OR LARGER ARE TO HAVE SUPPORT ANGLES <br />PER TYPICAL DECK OPENING DETAIL, INCLUDING OPENINGS FOR ROOF SUMP PANS. <br />10. PRIME AND PAINT ALL FIELD WELDS AFTER INSPECTION WITH A GALVANIZED <br />TOUCH-UP PAINT. (SEE NOTE BELOW) <br />11. SUBMITTALS: CONTRACTOR SHALL SUBMIT DETAILED SHOP DRAWINGS SHOWING LAYOUT <br />OF DECK, TYPE OF DECK, ALL CONNECTIONS INCLUDING END WELDS, SEAM WELDS, <br />INTERMEDIATE WELDS, AND ALL ACCESSORY MATERIAL SUCH AS CLOSURES, SUMPS <br />FOR DRAINS, ETC. <br />12. A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO VISUALLY INSPECT ALL <br />DECK WELDS AND FASTENERS. <br />COLD -FORM STEEL FRAMING <br />1. STEEL FRAMING SHALL CONFORM TO THE A.I.S.I. "SPECIFICATION FOR THE DESIGN OF <br />COLD -FORMED STEEL STRUCTURAL MEMBERS". <br />2. COLD -FORMED STEEL FRAMING SYSTEM, INCLUDING STUDS, TRUSSES, CONNECTIONS, <br />AND ALL ACCESSORIES, SHALL BE DESIGNED BY A DELEGATED ENGINEER WHO SHALL <br />PREPARE CALCULATIONS AND SUPERVISE THE PREPARATION OF SHOP DRAWINGS. <br />3. WELDED CONNECTIONS SHALL CONFORM TO "CODE FOR WELDING IN BUILDING <br />CONSTRUCTION, AWS D1.3". <br />4. ASTM A_568 STANDARD SPECIFICATION FOR GENERAL REQUIREMENTS FOR STEEL, <br />CARBON AND HIGH STRENGTH LOW -ALLOY HOT ROLLED SHEET AND COLD ROLLED <br />SHEET. <br />5. ALL STEEL FRAMING SHALL BE INSTALLED BY PERSONNEL EXPERIENCED IN LIGHT <br />GAUGE STEEL FRAMING INSTALLATION. <br />6. WHERE STEEL FRAMING MEMBERS ARE COMPONENTS OF ASSEMBLIES INDICATED FOR <br />A FIRE -RESISTANCE RATING, INCLUDING THOSE REQUIRED FOR COMPLIANCE WITH <br />GOVERNING REGULATIONS, PROVIDE MEMBERS WHICH HAVE BEEN APPROVED BY <br />GOVERNING AUTHORITIES HAVING JURISDICTION. <br />7. PROTECT LIGHT GAUGE STEEL FRAMING MEMBERS FROM RUSTING AND DAMAGE. <br />DELIVER TO PROJECT SITE IN BUNDLES, FULLY IDENTIFIED WITH NAME, BRAND, TYPE <br />AND GRADE. STORE OFF GROUND IN A DRY VENTILATED SPACE OR PROTECT WITH <br />SUITABLE WATERPROOF COVERINGS. <br />8. WITH EACH TYPE OF STEEL FRAMING REQUIRED, PROVIDE MANUFACTURER'S STANDARD <br />STEEL RUNNERS (TRACKS), BLOCKING, LINTELS, CLIP ANGLES, BRACING, <br />REINFORCEMENTS, FASTENERS, AND ACCESSORIES AS RECOMMENDED BY <br />MANUFACTURER FOR APPLICATIONS INDICATED, AS NEEDED TO PROVIDE A COMPLETE <br />STEEL FRAMING SYSTEM. <br />9. FABRICATE METAL FRAMING COMPONENTS OF STRUCTURAL QUALITY SHEET STEEL <br />WITH A MINIMUM YIELD POINT OF 50,000 PSI FOR STUDS, AND 33,000 PSI FOR <br />RUNNERS; ASTM A653. <br />10. PROVIDE GALVANIZED FINISH TO METAL FRAMING COMPONENTS COMPLYING WITH ASTM <br />A525 WITH A G60 COATING. <br />11. PROVIDE MANUFACTURER'S STANDARD STRUCTURAL "CEE" SHAPED STEEL STUDS OF <br />SIZE, SHAPE, AND GAUGE INDICATED, WITH A NOMINAL 1-5/8" FLANGE AND MINIMUM <br />1/2" FLANGE RETURN LIP BY DIETRICH INDUSTRIES, INC. OR PRIOR APPROVED <br />EQUAL. <br />12. THE EXTERIOR WALL SYSTEM SHALL BE DESIGNED TO WITHSTAND BOTH POSITIVE AND <br />NEGATIVE WIND PRESSURE WITH A MAXIMUM DEFLECTION BASED UPON THE <br />APPLICABLE CODE AND MATERIAL REQUIREMENTS OF THE VENEER, BUT SHALL NOT <br />EXCEED L/360. <br />13. FRAMING COMPONENTS MAY BE PREFABRICATED INTO PANELS PRIOR TO ERECTION. <br />FABRICATE PANELS PLUMB, SQUARE, TRUE TO LINE AND BRACED AGAINST RACKING <br />WITH JOINTS WELDED. PERFORM LIFTING OF PREFABRICATED PANELS IN A MANNER TO <br />PREVENT DAMAGE OR DISTORTION. <br />I <br />14. INSTALL METAL FRAMING SYSTEMS IN ACCORDANCE WITH REVIEWED SHOP DRAWINGS. <br />15. INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUD DEPTH. ALIGN TRACKS <br />ACCURATELY TO LAYOUT AT BASE AND TOPS OF STUDS. SECURE TRACKS AS <br />RECOMMENDED BY STUD MANUFACTURER FOR TYPE OF CONSTRUCTION INVOLVED, <br />EXCEPT DO NOT EXCEED 24" O.C. SPACING FOR NAIL OR POWDER -DRIVEN <br />FASTENERS, OR 16" O.C., FOR OTHER TYPES OF ATTACHMENT. PROVIDE FASTENERS <br />AT CORNERS AND ENDS OF TRACKS. <br />16. WHERE REQUIRED, TEMPORARY BRACING SHALL BE PROVIDED UNTIL ERECTION IS <br />COMPLETED. <br />17. RESISTANCE TO BENDING AND ROTATION ABOUT THE MINOR AXIS SHALL BE PROVIDED <br />BY MECHANICAL LATERAL BRACING WHERE REQUIRED. <br />18. ATTACHMENTS OF SIMILAR COMPONENTS SHALL BE DONE BY WELDING, SCREW <br />ATTACHMENT, OR BOLTING. WIRE TYING OF FRAMING COMPONENTS SHALL NOT BE <br />PERMITTED. <br />19. WELDING OF MEMBERS LIGHTER THAN 18 GAUGE SHALL NOT BE PERMITTED. <br />20. SPLICES SHALL NOT BE PERMITTED. <br />21. PROVIDE HORIZONTAL BLOCKING BETWEEN EACH STUD AT 4'-0" ON CENTER MAXIMUM <br />OR AT EACH SHEATHING JOINT. <br />22. FULLY INSTALL ALL BRIDGING BEFORE APPLYING LOADS. <br />23. STEEL TRUSSES: <br />A) TRUSS ERECTOR IS RESPONSIBLE FOR ALL TEMPORARY BRIDGING OF THE TRUSS <br />SYSTEM DURING CONSTRUCTION. <br />B) TRUSSES SHALL BE DESIGNED SO THAT NO HORIZONTAL REACTIONS ARE <br />IMPOSED ON THE SUPPORTING STRUCTURE UNDER VERTICAL LOAD. <br />C) PREFABRICATED TRUSSES AND PANELS SHALL BE SQUARE AND BRACED AGAINST <br />RACKING. <br />D) TRUSS MANUFACTURER SHALL PROVIDE A BENT PLATE 3" X 3" X 14 GAUGE <br />TYPICAL AT ALL RIDGE AND VALLEY LINES. PROVIDE CONTINUOUS DECK SUPPORT <br />BETWEEN TRUSSES AT ALL HIPS, RIDGES, VALLEYS, AND CHANGES IN ROOF <br />SLOPE. <br />24. CONTRACTOR TO SUBMIT THE FOLLOWING: <br />A) SUBMIT COMPLETE STRUCTURAL CALCULATIONS FOR THE STEEL FRAMING SYSTEM. <br />CALCULATIONS SHALL COVER ALL STUDS, JAMB STUDS, RUNNER TRACK, BRACING, <br />ATTACHMENT OF LIGHT GAUGE FRAMING TO LIGHT GAUGE FRAMING, AND <br />ATTACHMENT OF LIGHT GAUGE FRAMING TO CONCRETE OR STRUCTURAL STEEL. <br />B) SUBMIT DETAILED SHOP DRAWINGS FOR STEEL FRAMING SHOWING THE TYPE AND <br />SPACING OF ALL MEMBERS. ALL ATTACHMENTS SHALL BE CLEARLY DETAILED ON <br />THE DRAWINGS. INDICATED SUPPLEMENTAL STRAPPING, BRACING, CLIPS, AND <br />OTHER ACCESSORIES REQUIRED FOR PROPER INSTALLATION. <br />C) SUBMIT CERTIFICATION OF MATERIALS FROM THE MANUFACTURER TO SHOW <br />COMPLIANCE WITH THESE SPECIFICATIONS AND RELATED DRAWINGS. <br />25. SUBMITTALS SHALL BEAR THE SEAL OF THE DELEGATED ENGINEER. <br />26. SUBMITTED SHOP DRAWINGS MUST BE CHECKED AND SIGNED BY THE GENERAL <br />CONTRACTOR. <br />O p <br />00 <br />a <br />'0 ao rp � ^ Z <br />J LL � O <br />�Ct <br />�Oa <br />mL."Ivav <br />. m N 2 O'�- <br />Z L� L li r_ <br />N O U a <br />N CU <br />N <br />0) <br />U <br />c <br />� <br />"o N N <br />D7 V' r <br />T 4 o <br />- <br />r,0,o <br />U <br />op , <br />wl� <br />MNQ <br />Cp C <br />n MLm <br />'Q@ <br />L <br />o @ <br />W <br />co <br />CO <br />c'u <br />pc <br />m <br />CO <br />U-a� <br />c6 m L <br />O- 'd U <br />E <br />W <br />R�, <br />2 <br />L <br />06 <br />Q <br />(DI <br />( <br />L <br />'an) <br />U <br />U <br />f0CN <br />U g co <br />T <br />r +L+ L <br />i <br />t�LL <br />O <br />/ , <br />N_ <br />Q <br />O <br />0 <br />0 <br />� <br />I <br />m <br />L <br />w <br />� <br />U <br />= <br />C <br />LL <br />I-L <br />I <br />CD <br />E <br />C J <br />Q:f <br />o <br />U <br />m <br />o <br />V <br />Cn <br />n, <br />J_ <br />J <br />= <br />= <br />m <br />< <br />Lu <br />N <br />C <br />O <br />U <br />0 <br />W <br />o <br />U <br />cn <br />m <br />Q) <br />w <br />D <br />N <br />O <br />6 <br />7 <br />9 <br />12 1 sheet no. <br />GENERAL NOTES <br />SCALE: AS NOTED S01.01 <br />