PLUMBING GENERAL NOTES <br />1. ALL WORK UNDER THIS DIVISION SHALL COMPLY WITH THE CODES AND STANDARDS AS LISTED ON THE PROJECT DRAWINGS AND TO OTHER PERTINENT CODES MADE A PART OF SUCH <br />CODE BY REFERENCE. <br />2. PLANS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE PLUMBING SYSTEM COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL LOCATION OF THESE <br />COMPONENTS SHALL BE DETERMINED IN THE FIELD IN COORDINATION WITH THE WORK OF OTHER TRADES, THE USE OF MANUFACTURER'S SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. <br />PLANS SHALL NOT BE SCALED. <br />3. NO EXCLUSIONS FROM OR LIMITATIONS IN THE LANGUAGE USED IN THE CONTRACT DOCUMENTS SHALL BE INTERPRETED AS MEANING THAT EQUIPMENT, <br />APPURTENANCES, AND/OR ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM ARE NOT TO BE PROVIDED AS REQUIRED. THE SEPARATE DIVISIONAL DRAWINGS AND <br />SPECIFICATIONS DO NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY TO PROVIDE THE WORK WHICH IS INDICATED ON ANY OF THE DRAWINGS OR DIVISION OF THE <br />SPECIFICATIONS. REVIEW AND COORDINATE THE SCOPE OF WORK WITH ALL SECTIONS TO ASSURE A COMPLETE AND FUNCTIONAL SYSTEM IS INSTALLED. <br />4. SUBMIT SHOP DRAWINGS OF ALL FIXTURE, EQUIPMENT, AND MATERIALS FOR REVIEW. INSTALL AND TEST ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. FOR ALL EQUIPMENT, WHICH HAS BEEN SCHEDULED DIRECTLY ON THE DRAWINGS, PROVIDE WITHIN THE SUBMITTAL, A <br />PERFORMANCE SCHEDULE FOR THE PROPOSED EQUIPMENT IN THE SAME FORMAT AS INCLUDED ON THE CONTRACT DOCUMENT. FAILURE TO PROVIDE REQUIRED PERFORMANCE SCHEDULE <br />WILL RESULT IN REJECTION OF THE ENTIRE SUBMITTAL. BIND SHOP DRAWINGS/CATALOG-CUTS IN THREE RING BINDERS WITH A TITLE SHEET AND IDENTIFICATION ON FRONT AND SIDE OF <br />THE BINDER. SUBMIT DRAWINGS AND CUT SHEETS FOR ALL PRODUCTS ALL AT ONE TIME. INDEX ALL ITEMS TO THE PROJECT MANUAL OR DRAWINGS AS APPLICABLE. SHOP DRAWINGS <br />THAT DEVIATE FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS SHALL LIST ALL DIFFERENCES IN A COVER LETTER ATTACHED TO TOP OF THE SUBMITTAL. ANY UNLISTED <br />DEVIATIONS FOUND DURING REVIEW WILL RESULT IN THE REJECTION OF THE ENTIRE SUBMITTAL. <br />5. PIPING AND OTHER ITEMS OF THE PLUMBING SYSTEM SHALL BE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE AND NOT FROM THE CEILING, CEILING SUSPENSION SYSTEM, <br />DUCTWORK OR ELECTRICAL SYSTEMS. <br />6. ALL PIPING MUST BE INSTALLED 6" AWAY FROM ANY FIRE RATED WALL. <br />7. FOR SEALING OF PIPE PENETRATIONS THRU FIRE RATED WALLS REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. ALL PIPE PENETRATIONS SHALL BE SEALED USING APPROVED <br />UL DETAILS. <br />8. PROVIDE ADDITIONAL PIPING SUPPORTS ON BOTH SIDES AND WITHIN 18" OF FIRE RATED WALLS. PIPING SHALL NOT BE SUPPORTED FROM ANY RATED WALL. SLEEVE AND/OR FIRESTOP <br />ALL PENETRATIONS THROUGH RATED WALL, CEILINGS, AND FLOOR WITH UL LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR EXCEED THE RATING OF THE WALL, <br />CEILING, OR FLOOR. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. <br />9. HANGERS, ANCHORS AND SUPPORTS SHALL SUPPORT THE PIPING AND THE CONTENTS OF THE PIPING. HANGERS AND STRAPING MATERIALS SHALL BE OF APPROVED MATERIALS THAT <br />WILL NOT PROMOTE GALVANIC ACTION. <br />10. HANGERS AND ANCHORS SHALL BE ATTACHED TO THE BUILDING CONSTRUCTION IN AN APPROVED MANNER. <br />11. ANCHORAGE SHALL BE PROVIDED TO RESTRAIN DRAINAGE PIPING FROM AXIAL MOVEMENT. FOR PIPE SIZES GREATER THAN 4", RESTRAINTS SHALL BE PROVIDED FOR DRAIN PIPES AT ALL <br />CHANGES IN DIRECTION AND AT ALL CHANGES IN DIAMETER GREATER THAN TWO PIPE SIZES. BRACES, BLOCKS, RODDING AND OTHER SUITABLE METHODS AS SPECIFIED BY THE COUPLING <br />MANUFACTURER SHALL BE UTILIZED. <br />12. ALL EQUIPMENT (WATER HEATERS, ETC) SHALL BE LABELED WITH PLASTIC SIGNS, LAMINATED, ENGRAVED: 1/8" THICK BLANKS FOR SIGNS SHALL BE A MINIMUM OF 1-3/4" HIGH, WITH 1" <br />HIGH LETTERS. LENGTH OF THE SIGN SHALL BE THE SUM OF THE LETTERS/NUMBERS PLUS 3/4" EACH END. <br />13. PROVIDE ALL OFFSETS AND FITTINGS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. MAKE CONNECTION TO SITE UTILITIES. COORDINATE WITH SITE UTILITY CONTRACTOR AS REQUIRED. <br />14. CONCEAL PIPING ABOVE CEILING, WITHIN WALL OR CHASES OR AS SPECIFICALLY NOTED. <br />15. PROVIDE ACCESS PANELS (EQUAL TO MIFAB PRODUCTS) FOR ALL VALVES CONCEALED IN WALLS OR ABOVE NON -ACCESSIBLE CEILINGS. <br />16. PROVIDE A 1/2" ROUND RED DOT ON THE CEILING GRID BELOW ALL VALVES. <br />17. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. IF PIPING IS NOT AVAILABLE CHROME PLATED, PIPING SHALL BE PAINTED WITH CHROME COLORED <br />PAINT. <br />18. PROVIDE CLEANOUTS IN ACCORDANCE WITH THE FLORIDA PLUMBING CODE, 6th EDITION (2017). INSTALL CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. WHEN OUTDOORS, PROVIDE <br />CONCRETE ADJACENT TO CLEANOUT. <br />19. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL PANELS. <br />20. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIERS DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF FIXTURE. <br />21. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, ETC. AND <br />MAKE READY TO USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS CONTRACTOR OR FURNISHED BY OTHERS. <br />22. SECURE THE BASE OF ALL WATER COOLERS TO THE WALL. CAULK ALONG TOP OF WATER COOLER TO WALL. <br />23. FOLLOW ADA GUIDELINES FOR ACCESSIBILITY TO PLACES OF PUBLIC ACCOMMODATION AND COMMERCIAL FACILITIES BY INDIVIDUALS WITH DISABILITIES. THESE GUIDELINES ARE TO BE <br />APPLIED DURING DESIGN, CONSTRUCTION AND ALTERATION OF SUCH BUILDING AND FACILITIES TO THE EXTENT REQUIRED BY REGULATIONS ISSUED BY FEDERAL AGENCIES, INCLUDING THE <br />DEPARTMENT OF JUSTICE, UNDER THE AMERICANS WITH DISABILITIES ACT (ADA) OF JANUARY 1997 AND THE REQUIREMENTS OF ANSI A117.1. <br />24. PRIOR TO ANY EXCAVATION OR DEMOLITION, THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. <br />25. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND ROUGHING DIMENSIONS OF ALL PLUMBING FIXTURES, DRAINS, FAUCETS, SHOWER HEADS, ETC. <br />26. ALL FLOOR DRAINS SHALL BE SERVED BY AN APPROVED TRAP PRIMER, EXCEPTION: SHOWER DRAINS. <br />27. PROVIDE 1 /2" TYPE K SOFT COPPER SUPPLY LINE FROM TRAP PRIMER TO FLOOR DRAIN PROVIDE CORROSION PROTECTION BELOW SLAB. <br />28. ALL HOSE BIBBS, WALL HYDRANTS AND HOSE END CONNECTIONS SHALL BE EQUIPPED WITH AN APPROVED INTEGRAL VACUUM BREAKER AND SHUT OFF VALVE LOCATED ABOVE THE <br />CEILING. UNLESS OTHERWISE NOTED, ALL WALL HYDRANTS AND HOSE BIBBS SHALL BE INSTALLED 24" ABOVE FINISHED FLOOR OR GRADE. <br />29. DIELECTRIC UNIONS SHALL BE INSTALLED AT ALL CONNECTIONS OF DISSIMILAR METALS (SUCH AS COPPER TO GALVANIZED STEEL). <br />30. ALL VENT PENETRATIONS THROUGH THE ROOF SHALL BE LOCATED A MINIMUM OF 10'-0" <br />FROM ALL FRESH AIR INTAKES, DOORS, WINDOWS AND OTHER BUILDING OPENINGS. WHERE <br />POSSIBLE, EXTEND VENT PIPE TO THE BACK SIDE OF BUILDINGS WITH SLOPED ROOFS. <br />31. BELOW GRADE SOIL, WASTE AND VENT PIPING SHALL BE PVC TYPE DWV AND SHALL CONFORM TO ONE OF THE FOLLOWING STANDARDS: ASTM D 2665, ASTM D 2949 OR CSA B181.2. <br />FITTINGS SHALL BE PVC AND SHALL CONFORM TO ONE OF THE FOLLOWING STANDARDS: ASTM D 2665, ASTM D 3311 OR ASTM F 1866. JOINTS SHALL BE SOLVENT CEMENTING. A PURPLE <br />PRIMER THAT CONFORMS TO ASTM F 656 SHALL BE APPLIED TO JOINT SURFACES (CLEAN AND FREE FROM MOISTURE). SOLVENT CEMENT NOT PURPLE IN COLOR AND CONFORMING TO <br />ASTM D 2564, CSA B137.3, CSA B181.2 OR CSA B182.1 SHALL BE APPLIED TO ALL JOINT SURFACES. <br />JOINTS SHALL BE IN ACCORDANCE WITH ASTM D 2855. <br />32. ABOVE GRADE SOIL, WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT HUBLESS CAST-IRON PIPE AND FITTINGS WITH WIDE BODY TYPE 304 STAINLESS STEEL HEAVY-DUTY COUPLINGS <br />WITH NEOPRENE GASKETS. PIPE SHALL CONFORM TO ASTM A 74, CISPI 301, OR ASTM A 888. COUPLINGS SHALL CONFORM TO CISPI 310 OR ASTM C 1277. THE ELASTOMERIC SEALING <br />SLEEVE SHALL CONFORM TO ASTM C 564 OR CAN/CSA B602 AND SHALL BE PROVIDED WITH A CENTER STOP. <br />33. HOT AND COLD WATER PIPING SHALL BE SEAMLESS TYPE "L" HARD COPPER TUBE AND SHALL CONFORM TO NSF 61 AND ONE OF THE FOLLOWING STANDARDS, ASTM B 75, ASTM B 88, <br />ASTM B 251 OR ASTM B 447. FITTINGS SHALL BE COPPER OR COPPER ALLOY AND SHALL CONFORM TO NSF 61 AND ONE OF THE FOLLOWING STANDARDS ASME B16.15, ASME B16.18, <br />ASME B16.22, ASME 816.23, ASME B16.26 OR ASME B16.29. SOLDERED JOINTS SHALL BE MADE IN ACCORDANCE WITH THE METHODS OF ASTM B828. THE JOINING OF WATER SUPPLY <br />SHALL BE 95/5 LEAD FREE SOLDER AND THE SOLDER SHALL CONFORM TO ASTM B 32. <br />34. THE CONTRACTOR SHALL FURNISH AND INSTALL VALVES WHERE INDICATED ON PLAN AND NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES <br />RATED FOR 125 PSI OR GREATER WORKING PRESSURE IN WATER PIPING. <br />BALL VALVES: NIBCO S-585-70 <br />GATE VALVES: NIBCO S-113 <br />CHECK VALVES: NIBCO S-413 <br />BALANCING VALVE: NIBCO S-1710 <br />35. INSULATE ALL DOMESTIC HOT WATER PIPING WITH 1" THICK FIBERGLASS WITH "ASJ" VAPOR BARRIER JACKET AND 25/50 FIRE/SMOKE RATING. <br />36. VERIFY SIZES, LOCATION, INVERTS AND ELEVATIONS PRIOR TO INSTALLING ANY PIPING. <br />37. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND SHALL FURNISH EQUIPMENT <br />WIRED FOR THE VOLTAGE SHOWN HEREIN. PROVIDE STATEMENT INDICATING THIS HAS OCCURRED WITH THE SHOP DRAWING SUBMITTALS. <br />38. SLOPE ALL SANITARY PIPING 3" TO 6" AT A MINIMUM SLOPE OF 1/4" PER FOOT. ALL SANITARY PIPING 2-)2" AND SMALLER SHALL BE SLOPED AT A MINIMUM OF 1/4" PER FOOT. <br />39. ALL EXPOSED PIPING UNDER ACCESSIBLE LAVATORIES SHALL BE INSULATED WITH PROTECTIVE UNDER -SINK PIPE COVERS AND PLUMBING ENCLOSURES FROM TRUEBRO. <br />40. ALL SANITARY, VENT AND WATER PIPING SHALL BE TESTED BEFORE BEING CONCEALED IN ANY WAY. ALL JOINTS SHALL BE MADE DRIP TIGHT BEFORE BEING CONCEALED. DOMESTIC <br />WATER PIPING SHALL BE TESTED AT 1-1/2 TIMES OPERATING PRESSURE OR 100 PSI, WHICHEVER IS GREATER. <br />41. PLUMBING CONTRACTOR SHALL DISINFECT POTABLE WATER SYSTEM PER THE FLORIDA BUILDING CODE, 6th EDITION (2017). PROVIDE DOCUMENTATION IN THE CLOSE OUT DOCUMENTS. <br />PLUMBING FIXTURES <br />MINIMUM CONNECTIONS <br />FIXTURE <br />TRIM <br />SEAT <br />DRAIN <br />TRAP <br />SUPPLY <br />CARRIER <br />INSULATION <br />WASTE VENT CW HW <br />WATER CLOSET/ADA <br />SOLID PLASTIC, <br />INTEGRAL <br />CAST BRASS, <br />WHITE, VITREOUS CHINA, ELONGATED <br />OPEN FRONT, <br />LOOSE KEY HANDLE, <br />WC-1 <br />4pp <br />2 <br />1 /2 <br />- <br />BOWL, 1.28 GPF, 2-1 /8 GLAZED <br />LESS COVER, <br />CHROME PLATED. <br />-- <br />-- <br />TRAPWAY, PRESSURE ASSISTED, FLOOR <br />WHITE. <br />MOUNTED. <br />MCGUIRE 2166LK <br />BEMIS 1655SSCT <br />KOHLER "CIMARRON" K-3609 <br />LAVATORY/ADA <br />CHROME FINISH, CAST <br />CAST BRASS <br />CHROME PLATED <br />CHROME PLATED, <br />ADJUSTABLE SUPPORT <br />WHITE, FLEXIBLE <br />WHITE, ENAMELED CAST IRON, WALL <br />BRASS, 4" CENTERSET, <br />CHROME PLATED <br />CAST BRASS BODY <br />LOOSE KEY HANDLE, <br />SYSTEM, STEEL <br />VINYL, MOLDED, <br />S-1 <br />1-1/2" <br />1-1/2" <br />1 /2" <br />1 /2" <br />HUNG, 19" X 17", 4" CENTERS, WITH <br />BLADE TYPE HANDLE, <br />-- <br />OFFSET WHEELCHAIR <br />WITH CLEANOUT <br />TWO REQUIRED. <br />UPRIGHTS. <br />PROTECT DRAIN, <br />OVERFLOW, FOR CONCEALED ARM <br />VANDAL RESISTANT <br />STRAINER, 1-1/4" <br />PLUG, 1-1/4" X <br />TRAP AND SUPPLIES. <br />CARRIER. <br />OUTLET, 0.5 GPM. <br />OFFSET TAILPIECE. <br />1-1/2". <br />MCGUIRE 2165CCLK <br />JAR R SMITH SERIES <br />700 AS REQUIRED <br />TRUEBRO <br />KOHLER "HUDSON" K-2861 <br />SYMMONS S-60-H <br />MCGUIRE 155A <br />MCGUIRE 8902 <br />"LAV-SHIELD" <br />MODEL #2018-KO-H <br />SINK <br />CHROME FINISH, <br />STAINLESS STEEL <br />CHROME PLATED <br />1 /2" NOMINAL X <br />STAINLESS STEEL, TYPE 304, 18 GAUGE, <br />METAL CONSTRUCTION, <br />STRAINER BODY, <br />CAST BRASS BODY <br />3/8" O.D. ANGLE <br />S-2 <br />1-1/2" <br />1-1/2" <br />1 /2" <br />1 /2" <br />UNDERMOUNT, SINGLE BASIN, OVERALL <br />SINGLE LEVER HANDLE, <br />-- <br />1-1 /2"x4" <br />WITH CLEANOUT <br />SUPPLY, LOOSE KEY <br />-- <br />-- <br />18-1 /2% 18-1 /2% 5-1/2" DEEP, FULLY <br />QUARTER TURN <br />CHROME PLATED <br />PLUG, 1-1/2" X <br />STOP, WALL FLANGE, <br />UNDERCOATED, 3-1/2" CENTER REAR <br />CERAMIC CONTROL <br />BRASS TAILPIECE, <br />1-1/2". <br />CHROME PLATED. <br />LOCATION DRAIN OPENING. <br />COMPONENTS, <br />FITS 3-1/2" DRAIN <br />GOOSENECK SPOUT, <br />OPENINGS. <br />MCGUIRE 8912 <br />MCGUIRE 2165CCLK <br />ELKAY "LUSTERTONE" ELUHAD1616 <br />1.5 GPM. <br />ELKAY LK99 <br />SYMMONS DIA <br />SPB-3510-1.5 <br />ELECTRIC WATER COOLER/ADA <br />CHROME PLATED <br />CHROME PLATED, <br />ADJUSTABLE SUPPORT <br />SELF CONTAINED, BI-LEVEL, WALL HUNG, <br />CAST BRASS BODY <br />SOLID BRASS, <br />SYSTEM, STEEL <br />EWC-1 <br />1-1 /2" <br />1-1 /2" <br />1 /2" <br />- <br />ELECTRIC REFRIGERATED, BARRIER FREE <br />-- <br />-- <br />-- <br />WITH CLEANOUT <br />LOOSE KEY HANDLE, <br />UPRIGHTS, 3"X4" <br />-- <br />ACCESS, SELF CLOSING EASY TOUCH <br />PLUG, 1-1/4" X <br />ONE REQUIRED. <br />BASE PLATE. <br />CONROL. CERTIFIED TO NSF/ANSI 61. <br />1-1/2". <br />ZURN Z8804LKQ-PC <br />JAY R SMITH 0830 <br />ELKAY LZSTL8C <br />MCGUIRE 8902 <br />ELECTRIC WATER HEATER <br />ON SHELF IN FOOD SERVICE ROOM <br />EWH-1 <br />3/4" <br />- <br />RHEEM MODEL XE20SO6ST38U0 <br />-- <br />-- <br />-- <br />-- <br />-- <br />-- <br />-- <br />20 GAL. <br />MOP BASIN <br />POLISHED CHROME, <br />WHITE, MOLDED STONE, 24"x24"x10" <br />VACUUM BREAKER, <br />3" PVC P-TRAP <br />MB-1 <br />3" <br />2" <br />3/4" <br />3/4" <br />HIGH, STAINLESS STEEL DRAIN BODY, <br />3/4" HOSE END, <br />COMBINATION DOME STRAINER AND <br />INTEGRAL STOPS, <br />STAINLESS STEEL LINT BASKET, 3" <br />ADJUSTABLE SUPPLY <br />CONNECTION, HOSE AND WALL HOOK <br />ARMS. <br />832 AA, MOP HANGER 889 CC, <br />STAINLESS STEEL WALL GUARDS. <br />CHICAGO 897 <br />FIAT MSB-2424 <br />ABBREVIATIONS <br />SYMBOL DESCRIPTION <br />BFF <br />BELOW FINISH FLOOR <br />BFP <br />BACKFLOW PREVENTOR <br />CFH <br />CUBIC FEET PER HOUR <br />CO <br />CLEANOUT <br />CW <br />DOMESTIC COLD WATER <br />DFU <br />DRAINAGE FIXTURE UNIT <br />'F <br />DEGREE FAHRENHEIT <br />FD <br />FLOOR DRAIN <br />GPH <br />GALLONS PER HOUR <br />GPM <br />GALLONS PER MINUTE <br />HB <br />HOSE BIBB <br />HW <br />DOMESTIC HOT WATER <br />HWR <br />DOMESTIC HOT WATER RETURN <br />IE <br />INVERT ELEVATION <br />KW <br />KILOWATT <br />PSI <br />POUNDS PER SQUARE INCH <br />PVC <br />POLYVINYL CHLORIDE PIPE <br />SAN <br />SANITARY <br />SFU <br />SUPPLY FIXTURE UNIT <br />TPV <br />TEMP/PRESSURE RELIEF VALVE <br />UN <br />UNION <br />VTR <br />VENT THRU ROOF <br />WH <br />WALL HYDRANT <br />PLUMBING LEGEND & SYMBOLS <br />SANITARY SOIL & WASTE <br />SAN <br />SANITARY SOIL & WASTE (BELOW GRADE) <br />SAN <br />SANITARY VENT <br />V <br />DOMESTIC COLD WATER <br />CW <br />DOMESTIC HOT WATER (110') <br />HW <br />DOMESTIC HOT WATER (120') <br />HW <br />120 <br />DOMESTIC HOT WATER RETURN <br />HWR <br />PIPE DROP <br />D, <br />PIPE RISE <br />0- <br />PIPE CONNECTION (TOP) <br />n <br />PIPE CONNECTION (BOTTOM) <br />SHUT-OFF VALVE (VERTICAL RISER) <br />I C <br />SHUT-OFF VALVE (IN CAST IRON BOX) <br />HOSE BIBB / WALL HYDRANT <br />C <br />WALL CLEANOUT <br />FLOOR DRAIN <br />SHUTOFF VALVE <br />-v <br />GATE VALVE„ <br />- <br />CHECK VALVE (SWING) <br />UNION <br />( <br />BALANCING VALVE (CALIBRATED) <br />.01 <br />STRAINER <br />WATER HAMMER ARRESTOR <br />�- OR <br />TEMP/PRESS RELIEF VALVE (ASME) <br />a� <br />ti, <br />H <br />a� <br />o <br />`v <br />fn <br />U <br />c-+ <br />a <br />M <br />� <br />>F <br />V <br />V <br />a <br />C <br />in1 <br />C6 <br />go <br />w � <br />� <br />w <br />C N <br />ui <br />Cm <br />0 <br />U <br />C� <br />z <br />0 <br />J <br />m <br />Q <br />2 <br />o' <br />o w <br />z <br />= o <br />a � <br />o a- <br />C-.,) g <br />U d> <br />U <br />r4D CC) <br />O 6) <br />E­4 <br />b <br />100 ' DO <br />N <br />L-1 <br />PLUMBING NOTES <br />Scale: As Noted <br />Revisions: <br />Date: <br />12-29-17 <br />Drawn by. <br />CTK <br />Checked by. <br />CTK <br />1) �2 <br />Sheet No. of <br />