My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7821 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7821 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2025 2:20:37 PM
Creation date
1/21/2025 3:51:38 PM
Metadata
Fields
Template:
Building Plans
Street #
7821
Location
Gall Blvd
Contractor
Whites A-C Inc
Building Plans - Permit #
3761
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />REVISIONS <br />SYSTEM DESIGN VERIFICATION (SDV) <br />IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION <br />MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. <br />ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE <br />ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES <br />WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO <br />RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND <br />IT IS CRITICAL TO ROUTE THE GREASE DUCT STRAIGHT VERTICAL <br />BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP E <br />CHARGES. <br />DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND <br />co <br />APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. <br />(D <br />Robert E. Gregg FL#9927 <br />W <br />(0 <br />0 LL <br />*vi 00 <br />; 00 <br />In: Cl) <br />to Cl) Copy of this plan is not valid unless <br />0 co signed, sealed and dated by the <br />architect of record <br />00 <br />"............ . ....... <br />6j Copywrite <br />Exh Curb (+220.00AFF) .. ..Z <br />0 This drawing is the property of <br />DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING 1, T 1: a- R.E. Gregg Architects and under no <br />0: circumstances may this drawing b <br />VERIFY DECK HEIGHT e <br />CH LORIN ES/CH LORI DES. CONSULT WITH CAPTIVEAIREE reproduced, published, altered or used <br />P4 in any way without written authorization <br />LL <br />from R.E. Gregg Architects. <br />FOR PROPER LEAK TESTING METHODS. <br />E i <br />co <br />— -- - — ----- Contractor shall check and <br />Roof (+194.00"AFF) verify all dimensions and <br />coordinate all field conditions. <br />VERIFY JOIST HEIGHT <br />All discrepancies and conflicts <br />89W <br />78F shall be reported to the architect <br />51.5WIN in writing prior to proceeding or <br />continuing with construction. <br />2) Unreported discrepances and <br />. ... . ....... ... . ..... .......... . ......... . ..... .... . .. ... . conflicts shall remain the <br />(D <br />Truss (+156.00"AFF) 117,5W <br />107' responsibility of the contractor, <br />BONIN P3 1 LO <br />Height required to verify that the hood <br />will fit and to size the enclosure panels <br />LL <br />P P2 <br />2 <br />ILL <br />LU CIV-3 <br />---- --------- - - <br />----- <br />.. . ... .... ........ .. <br />1 <br />or <br />)ft Ceiling (+120.00"AFF) <br />1 <br />CD --j <br />>- ne <br />orf af <br />GREASE DUCT & CHIMNEY SPECIFICATIONS; <br />PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL"DW" <br />'DW` <br />C <br />ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL <br />"V" <br />IS LISTED TO UL-1 978 AND IS INSTALLED USING CLAMP LOCKING <br />"DV <br />T <br />i CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL <br />Uj <br />DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER <br />N <br />THE MANUFACTURES INSTALLATION GUIDE. <br />PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12'ON CENTER. PER MANUFACTURES LISTING MODEL"DW HORIZONTAL RUNS LESS THAN <br />t <br />z <br />00 <br />75 FT. CAN BE SLOPED 1116"PER 12', HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16"PER 12'. <br />Ili <br />DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. <br />C-) <br />IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL <br />CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL'DW- 2R, 2R TYPE HT, 3R, OR 3r ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 <br />(=) <br />LO <br />Cr) c') <br />STAINLESS OUTER SHELL. <br />o <br />-0 EL <br />Cn <br />DRAWN BY: KG <br />C)) <br />0 <br />C A <br />CHECKED BY: REG <br />C,4 <br />CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE -FABRICATED ROUND <br />00 a) <br />I ISSUE DATE: 1-12-201 <br />GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE <br />I <br />INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT <br />DATE: <br />!REVISIONS: <br />DWG.#: <br />5198383 <br />DRAWN <br />BY: celso.saenz <br />SCALE: <br />HVAC DISTRIBUTION NOTE <br />HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN <br />MASTER DRAWING <br />(10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. <br />.. ........ ......... . .. . ... . .... . ........ .......................... ............ .. . ..... . .... .. . . . .................... . .. . ..... ..................... ......... ... .... .. ..... <br />Floor (+0.00"AFF) <br />SHEET NO. <br />PLAN <br />MH4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.