Laserfiche WebLink
EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />c <br />Q <br />p D <br />EXISTING FOUNDATION. <br />d <br />CI \ p <br />p � e <br />p <br />FOOTING, SEE PLAN <br />TYPICAL STEP IN FOOTING DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB I BLOCK W/ (1) #4 OR #5 CONT. <br />Lu <br />QU) <br />0 <br />VAPOR BARRIER /\\/ <br />w <br />U <br />#4 OR #5 VERT REINFORCING �// <br />UP TO 3 COURSES: 72" O.C. \/\ <br />4 TO 5 COURSES: 48" O.C. ,�/�\/ <br />TIONAL #4 OR <br />FOOTING TO BEAR ON FIRM ��\�.. //�\ \' \\ #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />)US BAR AS 0'-0" A.F.F. <br />LAP AS SHOWN (BEYOND) <br />FLOATING CONCRETE w <br />SLAB W/ 6x6 W1.4xW1.4 Q <br />WWF OR FIBERMESH > <br />O DEGREE <br />PutLOO <br />Lu <br />U-BLOCK W/ <br />(1)#4OR#5 <br />CONT <br />~ <br />� <br />of <br />Z) <br />O <br />FINISH <br />GRADE <br />f , <br />\/\\/\\ <br />\ \ <br />\ \ \\ <br />TTI <br />L <br />FOOTING TO BEAR ON FIRM ADDITIONAL #4 OR <br />UNDISTURBED SOIL #5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />TSTEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL CMU STEMWALL MONO LITHIC SLAB 3 %2' CONCRETE SLAB W/ 6x6 <br />WHERE NEEDED I (1) #4 OR #5 CONT. W1.4 x W1.4 WWF OR FIBERMESH <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />INTO MONOLITHIC THICKENED EDGE MIN 24' LAP <br />MIN. 3" EDGE DISTANCE — — d °° a <br />>: �. — ----- — <br />36" MAX ARCH PLANS- <br />4" CONCRETE SLAB W/ ° q <br />STRIP OF WWF FROM F.F.E. TO 6x6 W1.4 x W1.4 WWF / / /\� \ /\//� <br />OR FIBER MESH�\ <br />BOTTOM OF FTG. WWF TO 12" MIN <br />p VAPOR BARRIER <br />EXISTING FOUNDATION FACE w/ o p — — W z �< •\\\��\\ \ <br />i p p D p (D 0 ° d°, i FOOTING TO BEAR ON FIRM <br />(2) ROWS OF 3/s' DIA. TAPCONS / c j <� ea ,d #4 OR #5 ///\�//� //�/� I al • j UNDISTURBED SOIL <br />OR CUT NAILS @ 24 O.C. COVER / o O , ° REINFORCING PER / <br />FLUSH w/ 3000psi CONCRETE. f p 0 Q Q MONOLITHIC FOOTING <br />° < ° d SECTION 6" OPT. EXTENSION b <br />FOOTING TO BEAR EXISTING FOUNDATION �° ° IN BRICK LOCATIONS <br />UNDISTURBED SOILON FIRM ON FND PLAN 12" UNDER 1 STORY WALL W/ (2) <br />° ° ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />1 d • MIN112" /\\/\\/\\/\\/\\/\\/\\ BAR IN BRICK LEDGE <br />I /i/,///////,//\ <br />d . , �/ a \ 16" UNDER 2 STORY WALL W/ (3) <br />#4 OR (2) #5 CONT <br />8" CMU WALL OVERHANGS 2.5" OR LESS %\%\% %\%\%\%\/ %\%\%i� \\ \ \\/STEMWALL FOOTING TO EXTEND MIN '� MONOLOTHIC FOOTING SECTION - 36 MAX DEPTH <br />\ 12" BELOW MONOLITHIC FOOTING <br />NOTES: //\//\//\//\//�\// "NOTE`: IT IS A���BTITUTE TH11A' FTG DETAIL FOR THE "1" <br />/\\//\\/i\\��\�� • ADDITIONAL #4 OR #5 VERTICAL TO BE FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, LOCATED WITHIN TRANSITION ZONE DEPTH EXCEEDS 28". <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL LOCATE VERTICAL AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST REINFORCEMENT IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO STEMWALL CELL STEEPER THAN V-0" VERTICALLY PER S-0" HORIZONTALLY, CONTRACTOR HAS <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. TWO CHOICES: <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, 1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />CONTACT EOR. CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 SEE NOTES (MAX 16") v <br />W1.4 x W1.4 WWF OR d <br />FIBERMESH STUCCO OR DIRECTLY ADHERED <br />STONE CLADDING FINISH - MIN 6" > <br />\ \ \ \ \ \ ALL OTHER EXTERIOR WALL N O 0 <br />CLADDING - MIN 8", U.N.O. ON ARCH O U <br />VAPOR BARRIER /\�\\ °\\ MIN/ <br />\\/\/\ p <br />"\/\\/\\/\\/\\ � <br />.� . APEX s <br />C:) <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK (D <br />FIRM UNDISTURBEDSOIL LOCATIONS ON FND PLAN Q <br />N <br />12" UNDER 1 STORY WALL w/ N <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J r <br />BAR IN BRICK LEDGE LL <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS LU <br />1 MONOLITHIC FOOTING SECTMFANY�OFTHE <br />5; tds <br />CONTACT FOR PRIOR TO CONSTRUCTION Z true design studios <br />O <br />FOLLOWING OCCUR: U) <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" Y <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 9000 REGENCY SQUARE BLVD. <br />PER T-0" HORIZONTALLYrO PREVENT EROSION OF SOIL, SUITE 100, JACKSONVILLE, FL 32211 <br />O O <br />CONCRETE SLAB w/ 6x6 i3 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR W <br />FIBERMESH H <br />°— -- a -- a \� � N <br />IRM190N <br />/ W, &ZAP <br />16" VAPOR BARRIER W Q <br />6200 LEE VISTA BLVD, STE 400 Q' <br />ORLANDO, FL 32822 <br />3 BEARING WALL FOOTING SECTION <br />U P: 407-850-5200 <br />z <br />a� <br />w <br />� <br />0 <br />CONCRETE SLAB W/ 6x6 <br />W <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />O <br />0'-0" A.F.F. O <br />_ SEE ARCH O <br />a a \d DETAILS 11�- <br />LO <br />8" MIN ~ <br />d O° <br />Z Z �^ <br />8"x8" THICKENED 8" (nFTG AT U) <br />V J <br />STEP-DOWN, SEE VAPOR BARRIER W Uj W <br />PLAN Z <br />4 CURB STEP SECTION m z W <br />X O OU) <br />W <br />8" UNDER MASONRY WALL Z �--• C <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL ( Q G <br />O 6x6 W1.4 x W1.4 WWF 11ZJ <br />OR FIBERMESH N <br />VARIES SEE ARCH < \ W <br />° (MAX 16") W <br />/\ /X/\/\/\� o // O� w Q_ <br />\�/\\� LLB <br />VAPOR BARRIER/\\ ° a I//�\//�\//�\//\\\ 0 L+ <br />6 OPT. EXTENSION IN BRICK Of X <br />LOCATIONS ON FND PLAN a <br />This item has been electronically <br />12" UNDER 1 STORY WALL w/ Of signed and sealed by Justin M Lanier, Z <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 O PE on the date and/or time stamp O <br />BAR IN BRICK LEDGE V shown using a digital signature. <br />16" UNDER 2 STORY WALL w/ 0 Printed copies of this document are 0 <br />not considered signed and sealed W <br />(2) #5 OR (3) #4 CONTINUOUS Of by a 3rd Party Certificate Authority ~ <br />on any �l�ctO Park cc <br />5 GARAGE EXT WALL CURB SECTION 0 a <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: Q V- <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" Z LOT 017-01 W <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY — V <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. i— W <br />0 <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR J O PROJECT NO: <br />FIBERMESH 0'-0" A.F.F. Z 2021.003463 z <br />SEE ARCH = <br />— o a — a — (MAX 20" U DRAWN: <br />° d ° DEEP) W LDG W <br />a MJP p <br />4" EXTENSION a o <br />UNDER BRICK VENEER O <br />LO <br />12" UNDER 1 STORY WALL <br />����►{{�{t<��I��vj <br />w/ (2) #4 OR (2) #5 CONT <br />VAPOR BARRIER <br />m <br />�. J5;vN LqN/,,,,�� <br />,•"�,� C' E N S�"R '��� <br />16" UNDER 2 STORY WALL <br />���` <br />U <br />wl (3) #4 OR (2) #5 CONT <br />j <br />No 85166 ! <br />•i* <br />(� <br />O <br />0 <br />6 BEARING CURB STEP SECTION <br />„*:• * = <br />W <br />.-� : : Ir <br />z <br />Q <br />�-J3 ' STATE OF • 4� <br />'. <br />i I I <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />-------------- <br />HOUSE SLAB <br />N <br />O <br />�O AU <br />F- <br />03-18-2021 <br />Z <br />i'- <br />Q <br />REVISIONS: <br />Q <br />� <br />u) <br />No. <br />Description <br />Date <br />C1 <br />} <br />-- <br />W <br />Cn <br />O <br />W <br />= <br />J <br />O <br />- — <br />H <br />z <br />w <br />J <br />RE-ENTRANT CORNER DETAIL U U <br />(RECOMMENDED) (- <br />PLAN VIEW, DETAIL TYPICAL @ ALL >( ~ <br />RE-ENTRANT CORNERS W Z <br />ST=2mD 00 <br />a <br />CMU/METAL CONNECTOR ENGINEERING 0 <br />