Laserfiche WebLink
3ocuSign Envelope ID: 3CE76BFD-2711-4B94-92E4-ACF95934EBC2 <br />O O <br />O y <br />N <br />U') cy <br />V-: O <br />4 APEX <br />0 <br />CD 0 <br />m '5<' <br />cc <br />N <br />N <br />co <br />U_ <br />J <br />J_ <br />; tds <br />ztrue design studios <br />U) <br />Y <br />Q 9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />1 O t <br />\ 1 ELECTRIC METER U) <br />ELECTRIC METER �— FIELD VERIFY LOCATION A <br />FIELD VERIFY'i��� <br />LOCATION I APPLY STUCCO SCRATCH COAT AND ONE (1) a) <br />PRE -FORMED CONTROL 5/8" CEMENT PLASTER JOINT W/ STRIP LATH LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC J <br />12" WIDE SELF-ADHESIVE METER W <br />FLASHING CENTERED UNDER • _0. •-=� CONTROL JOINT (CLEAN CAVITY TO BE FILLED Q <br />• ••• MASONRY BEFORE APPLYING) WITH RIGID POLYMERIC � <br />` \ ISOCYANOTE-POLYBLEN C1 6200 LEE VISTA BLVD, STE 400 <br />FOAM ('GREAT STUFF" OR W <br />ORLANDO, FL 32822 <br />/ SIMILAR) U P: 407-850-5200 <br />\ \ / APPLY A SILICON BASE Z <br />STUCCO FINISH SEALANT AT POINT THAT w <br />ELEC WIRE PENETRATES <br />5/8" CEMENT PLASTER / w <br />/ 6" SELF ADHESIVE <br />•` 12" WIDE SELF-ADHESIVE L OVER TOP & SIDES 0 <br />FLASHING CENTERED UNDER / 00 <br />CONTROL JOINT (CLEAN / \ SELF FLASHING • 0) <br />MASONRY BEFORE APPLYING) / \ UNIT ti <br />PRE -FORMED CONTROL I _ PROVIDE STUCCO <br />SCRATCH COAT LARGER ti <br />�• THAN THE ELECTRIC <br />JOINT W/ STRIP LATH • � "^ PREMANUF. METER CAN OR METER 0 <br />\ / DRYER VENT CAP z <br />(SET IN CONT. CAN COMBO OR METER Z r /1 <br />8" CMU .,. — SEALANT) AREA TO RECEIVE CAN AND DISCONNECT U) V J <br />f STUCCO SCRATCH COAT (1)W <br />SEALANT at & 1 COAT OF PAINT W/ w <br />TOP & SIDES BACK -ROLL PRIOR TO Z <br />ELECTRIC METER U <br />INSTALLATION m z W <br />ww w O o c) <br />_ <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION z <br />SCALE: N.T.S. Z in <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. w > O <br />CV w <br />fr_ 10 J LU <br />LU <br />WOOD CONST BEYOND 0 Q <br />FIBERCEMENT -OR- VINYL LAP <br />WOOD SHEATHING SIDING OVER APPROVED Z LjL_W <br />6" SELF -ADHERING WEATHER RESISTIVE HOUSEWRAP INSTALLED PER O <br />FLASHING BARRIER #1 : FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS P - <br />THREE COAT STUCCO FINISH EXTEND HOUSEWRAP Q t <br />WEATHER RESISTIVE WEATHER RESISTIVE (718' NOM) OVER GALV MTL LATH OVER NAILING FLANGE X <br />WD SHEATHING _ <br />BARRIER #1 BARRIER #2 OVER 15# FELT OVER APPROVED O <br />VINYL ANGLED Q\\ \ (RE: STRUCT) HOUSEWRAP WD SHEATHING <br />CASING BEAD WEATHER RESISTIVE (D (RE: STRUCT) Z <br />(AM66-ANGLED-1250) BARRIER #2 \ 5/16" X 7 1/4" LAP FASTEN TO WD STRUCTURAL O " 0 <br />\ SIDING W/ 6 REVEAL MEMBER at 7O.C. MAX U <br />I - MTL DRIP FLASHING W! 0 <br />STARTER STRIP 78" TO 48" MID -WALL = HEMMED EDGE SET IN CONT w <br />2 1/2" `-A WEEP SCREED BEAD OF SEALANT <br />_ <br />8" CMU CORNER BEAD SE NOT CAULK OR TRIM (RE: ELEVATION) O Abbott Park <br />(FASTENER & 6" SELF -ADHERING .. SEAL OPENING _ Z 0_ <br />z o SPACING at 7"O.C.) FLASHING ' ° �' g EXTEND 12" SELF -ADHERING LL d <br />m a N GALVD METAL MEMBRANE FLASHING OVER Q — <br />`, LL <br />GALV DMETAL "Z" WINDOW FLANGE SET IN CONT <br />(n LL = J N "Z" FLASHING FLASHING 6" WIDE STRIP SELF ADHESIVE - LOT 017-01 w <br />W_ 0 w BEAD OF SEALANT <br />w w FLASHING, CLEAN MASONRY U J <br />> = 3 DO NOT CAULK OR Z Q <br />Q SEAL OPENING 1 1/4" X 6" SIMULATED BEFORE APPLYING VINYL FLANGE CASING BEAD — U <br />WOOD TRIM MEMBER INSTALLED PER MFRcn <br />�. <br />/ 1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) <br />CMU / STUCCO TEXTURED PER COMMUNITY 0 0 <br />1 1/4" X 6" SIMULATED CASING BEAD SPECIFCATIONS 1/2" (MIN) STUCCO FINISH W <br />VINYL CASING WOOD TRIM MEMBER '' :• -;< TEXTURED PER COMMUNITY PROJECT NO: F- <br />BEAD (AM66-1250) 1/2" (MIN) STUCCO FINISH ; : SPECIFCATIONS Z 2021.003463 Z <br />1/2" (MIN) TEXTURED TEXTURED PER COMMUNITY = 0SEAL GAP W/ CAULKING <br />FINISH at MASONRY SPECIFCATIONS OR APPROVED SEALANT /, c ' I (� (' w DRAWN: LDG <br />STUCCO CASING BEAD y STUCCO SIDING x w <br />0 <br />X CHKD: <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) Q JAC <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. x o <br />SCALE: N.T.S. � <br />In w <br />0 J <br />w U <br />Z U) <br />� 0 <br />O <br />112" (MIN) STUCCO CMU WALL W! CMU WALL W/ — <br />SELF ADHESIVE -OR- FLUID W Z <br />APPLIED PAN FLASHING (CLEAN <br />FINISH TEXTURED 48 <br />MASONRY BEFORE APPLYING) (RE: STRUCTURAL) (RE: STRUCTURAL) Z Q <br />PER COMMUNITY (RE: STRUCTURAL) EXTEND UP AT JAMBS (4" MIN) ?�" GYP BRD OVER "GYP BRD OVER <br />SPECIFCATIONS GYP BRD OVER " " GYP BRD OVER <br />�i PRE -SHAPED STUCCO BAND 1 1x2 TREATED PRE -SHAPED STUCCO BAND 1x2 TREATED 1x2 TREATED p <br />1x2 TREATED W/ SLP TOP INSTALLED PER W/ INSTALLED PER MFR <br />FURRING STRIPS MFR WRITTEN SPECS (RE: FURRING STRIPS WRITTEN SPECS (RE: ELEV) FURRING STRIPS FURRING STRIPS <br />at CMU WALL (TYP) ELEV) at CMU WALL (TYP) PRECAST CONCRETE SILL at CMU WALL (TYP) CONTINUOUS BEAD at CMU WALL (TYP) CONTINUOUS BEAD O <br />FLANGE CASING OF SEALANT OF SEALANT BEAD MASONRY <br />SELF ADHESIVE -OR-FLUID WOOD BLOCKIN SELF ADHESIVE -OR-FLUID BACKER ROD W/SEALANT PT 1x4 03-18-2021 Z <br />APPLIED FLASHING (CLEAN APPLIED FLASHING (CLEAN PT 1x4 SELF ADHESIVE -OR- SELF ADHESIVE -OR- U <br />MASONRY BEFORE APPLYING) MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED PT 2x4 FRAME FLUID APPLIED <br />PT 1x WOOD BUCK VINYL FLANGE CASING BEAD PT 1x WOOD BUCK VINYL FLANGE CASING BEAD„ GYP BRD OVER INSTALLED PER MFR PT 2x4 FRAME ANCHOR FLASHING (CLEAN ANCHOR FLASHING (CLEAN LL REVIS NS: Q <br />1x2 TREATED WRITTEN SPECS (TYP) SHIM AS NEEDED ��MppAPPS��OyYNNRGY�BEFORE MASONRY BEFORE Q < <br />SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR FURRING STRIPS METALI ppOR FRAME SHIM AS NEEDED�I��OR FRAME NO. Description Date Of <br />WRITTEN SPECS (TYP) WRITTEN SPECS (TYP) at CMU WALL (TYP) CMU STEMWALL W/ — <br />48' STUCCO FINISH > W 48" BACKER ROD W/ SEALANT" BACKER ROD W/ SEALANT (RE: STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR 0 w <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR 0 <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU Z <br />SCALE: N.T.S. SCALE: 112" = 1'-0" SCALE: 1 " = 1'-0" SCALE: 1 " = 1'-0" SCALE: 1 " = 1'-0" SCALE: 1 1/2" = 1'-0" w <br />X 0 <br />w Z <br />m A501 Q O <br />0 <br />