ELECTRICAL <br />ABBREVIATIONS <br />AFCI <br />ARC FAULT CIRCUIT INTERRUPT <br />A.F.F. <br />ABOVE FINISHED FLOOR <br />EM. <br />EMERGENCY <br />EWH <br />ELECTRIC WATER HEATER <br />EWC <br />ELECTRIC WATER COOLER <br />FAP <br />FIRE ALARM PANEL <br />GD <br />GARBAGE DISPOSAL <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPT <br />HP <br />HORSE POWER <br />IWH <br />INSTANT WATER HEATER <br />MTD <br />MOUNTED <br />MW <br />MICROWAVE <br />RECEPT. <br />RECEPTACLE <br />REF <br />REFRIGERATOR <br />SA <br />SMALL APPLIANCE BRANCH CIRCUIT <br />UG <br />UNDERGROUND <br />V <br />VO LT <br />WP <br />WEATHER PROOF <br />XFMR,XFMER <br />TRANSFORMER <br />0 <br />PHASE <br />ELECTRICAL SYMBOLS <br />(RECEPTACLES) <br />20A, 125V, 2P, 3W, GNDING TYPE DUPLEX RECEPTACLE MNT. <br />18" AFF UNLESS NOTED OTHERWISE. <br />20A, 125V, 2P, 3W, GNDING TYPE DUPLEX RECEPTACLE <br />MOUNTED 6" ABOVE COUNTER. <br />20A, 125V, 2P, 3W, GNDING TYPE QUAD RECEPT. MNT. <br />18" AFF <br />ELECTRICAL SYMBOLS <br />(SWITCHES) <br />20A, 120/277V SINGLE POLE SWITCH MTD. 48" AFF <br />$3 <br />20A, 120/277V THREE WAY SWITCH MTD. 48" AFF <br />$D <br />20A, 120/277V DIMMER SWITCH MTD. 48" AFF <br />$M <br />MOTOR RATED SWITCH WITH OVERLOAD PROTECTION EQUIP. <br />MTD. <br />20A, 120/277V SINGLE POLE SWITCH MTD. 48" AFF W/INTEGRAL <br />$ <br />OCCUPANCY SENSOR (PROVIDE DUAL TECHNOLOGY PIR AND US) <br />"LIGHTOLIER INTELLISIGHT ITS2UW" <br />NOTE: LIGHT SWITCHES LOCATED ADJACENT TO EACH_ OTHER SHALL BE GANGED <br />TOGETHER IN ONE COMMON BACKBOX UNDER A COMMON CONTINUOUS <br />FACEPLATE. PROVIDE VOLTAGE BARRIERS AS REQUIRED. <br />ELECTRICAL SYMBOLS <br />(VISUAL/AUDIO) <br />TELEVISION CABLE OUTLET BOX 4" SQ X 2 1 /2" DEEP SINGLE <br />191 GANG BOX RECESSED MTD +75"AFF UNLESS NOTED OTHERWISE <br />AV J-BOX SINGLE GANG WITH MUD RING FOR AUDIO VISUAL <br />EQUIPMENT <br />ELECTRICAL SYMBOLS <br />(POWER DISTRIBUTION) <br />* <br />3P30 <br />DISCONNECT SWITCH. <br />3P = # OF POLES, 30 = FRAME SIZE, * = FUSE PER <br />MANUFACTURERS RECOMMENDATIONS. <br />0 <br />120/208V, 30, 4W PANELBOARD <br />0, a <br />CEILING & WALL MOUNTED JUNCTION BOX, SIZE AS REQ. TO MEET <br />NEC-370 (MINIMUM 4"x4"x2-1/2") <br />MOTOR, HP SIZE AS INDICATED <br />ELECTRICAL SYMBOLS <br />(SECURITY) <br />PCR <br />SECURITY PROXIMITY CARD READER DEVICE. WALL MTD. 48" <br />AFF. REFER TO E201 FOR LOCATIONS <br />SECURITY CARD ACCESS SYSTEM PUSHBUTTON EMERGENCY RELEASE <br />MTD. 48" AFF. REFER TO SHEET E601. <br />REX <br />AUTOMATIC RELEASE EGRESS PROXIMITY MOUNTED ABOVE DOOR. <br />REFER TO SHEET E601 FOR DETAILS. <br />DC <br />DOOR MOUNTED SECURITY SYSTEM DOOR CONTACT. <br />KP <br />WALL MOUNTED ARMING STATION KEYPAD <br />MD <br />CEILING MOUNTED SECURITY SYSTEM MOTION DETECTOR <br />GB <br />CEILING MOUNTED GLASS BREAK DETECTOR <br />ELECTRICAL SYMBOLS <br />(TELECOMMUNICATIONS) <br />TELEPHONE TERMINAL BACKBOARD, 3/4" PLYWOOD 8'X4' <br />PAINTED ON ALL SIDES IN A FIRE RETARDANT MEDIUM GRAY <br />COLOR AS PER TIA 5698 <br />TELEPHONE/DATA OUTLET JACK MOUNTED 18" A.F.F. UNLESS <br />V <br />OTHERWISE NOTED. EXTEND 3/4" CONDUIT TO DATA SERVER <br />ROOM IN DATA SERVER RACK <br />ELECTRICAL SYMBOLS <br />(LIGHTING) <br />2'X4' RECESSED FLUORESCENT LIGHT FIXTURE. MOUNTING <br />® <br />AS PER FIXTURE SCHEDULE. <br />2'X4' RECESSED FLUORESCENT LIGHT FIXTURE WITH BATTERY <br />BACK-UP MOUNTING AS PER FIXTURE SCHEDULE. <br />O <br />RECESSED DOWNLIGHT FIXTURE <br />-E- <br />PENDANT DECORATIVE FIXTURE <br />CEILING MOUNTED OCCUPANCY SENSOR. PROVIDE CONTACTORS/ <br />OS <br />POWER PACKS FOR MULTIPLE CIRCUIT AND OCCUPANCY SENSOR TO <br />CONTROL ENTIRE ROOM (PROVIDE DUAL TECHNOLOGY PIR AND US) <br />SET AT 30 MINUTE DELAY. <br />9 <br />CEILING & WALL MOUNTED EXIT SIGNS WITH BATTERY BACK-UP <br />A <br />LIGHTING FIXTURE SCHEDULE TYPE "A" <br />a <br />LOWER CASE LETTER DESIGNATES SWITCHING <br />ELECTRICAL SYMBOLS <br />(CONDUCTORS/CONDUITS) <br />-----� <br />CONCEALED CONDUIT <br />CONCEALED CONDUIT BELOW GRADE <br />VVVVV <br />FLEXIBLE METAL CONDUIT (GREENFIELD) <br />HOMERUN TO PANELBOARD. SHORT TICKS INDICATE PHASE <br />CONDUCTORS & LONG TICK INDICATES NEUTRAL. LONG I TICK <br />INDICATES GROUND CONDUCTOR. <br />GROUND <br />ELECTRICAL SYMBOLS <br />(FIRE ALARM) <br />❑F <br />FIRE ALARM PULL STATION MT. 48" AFF <br />FIRE ALARM SPEAKER/ VISUAL LIGHT COMBINATION <br />S <br />(75cd UNLESS NOTED OTHERWISE) MNT. 80" AFF <br />SL <br />STROBE LIGHT (75cd UNLESS NOTED OTHERWISE), MTD. 80" <br />AFF <br />CEILING MOUNTED FIRE ALARM SPEAKER/ VISUAL LIGHT <br />COMBINATION <br />(75cd UNLESS NOTED OTHERWISE) LOCATE WHERE SHOWN ON <br />PLANS. <br />OD <br />SMOKE DETECTOR, CEILING MTD. <br />DUCTSMOKE DETECTOR WITH AIR SAMPLING TUBES MOUNTED <br />@ <br />ON THE AIR SUPPLY DUCT W/REMOTE TEST SWITCH, COORD. <br />W/ MECH. DWGS FOR QTY <br />GENERAL ELECTRICAL NOTES: <br />CONTRACTOR MUST VISIT THE PROJECT SITE PRIOR TO BIDDING AND BECOME FAMILIARIZED <br />WITH ALL EXISTING CONDITIONS THAT MIGHT AFFECT HIS WORK. ANY EXISTING CONDITIONS <br />CHANGE IN EXTRA MATERIALS AND/OR LABOR WILL NOT BE ACCEPTED FOR ADDITIONAL <br />PAYMENT. CONTRACTOR MUST PROVIDE A PERCENTAGE COST FOR UNIDENTIFIED ITEMS IN <br />HIS BID. <br />1. ALL MATERIALS AND/OR EQUIPMENT SHALL BEAR THE LABEL OF THE UNDERWRITER'S <br />LABORATORIES (UL) AND SHALL BE MATERIAL APPROVED FOR USE BY LOCAL CODE <br />ENFORCING AUTHORITIES. <br />2. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL <br />ELECTRICAL CODE(NEC), NATIONAL FIRE PROTECTION ASSOCIATION(NFPA), INSTITUTE OF <br />ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE), ILLUMINATING ENGINEERING SOCIETY OF <br />NORTH AMERICA (IESNA), THE FLORIDA BUILDING CODE (FBC) AND ALL LOCAL CODES <br />HAVING JURISDICTION. <br />3. ANY AND ALL ITEMS NOT SPECIFICALLY MENTIONED IN THE DRAWINGS OR THE CONTRACT <br />SPECIFICATIONS BUT WHICH ARE OBVIOUSLY NECESSARY FOR A COMPLETE WORKING <br />INSTALLATION SHALL BE INCLUDED. <br />4. PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR IS REQUIRED TO VISIT THE SITE <br />OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF WITH THE NATURE AND EXTENT OF THE <br />PROPOSED WORK AND ANY LOCAL CONDITIONS WHICH MAY IN ANY WAY AFFECT THE WORK <br />TO BE DONE. <br />5. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY <br />DISCREPANCIES ENCOUNTERED DURING THE COURSE OF THIS SITE VISIT: <br />6. ALL CONDUCTORS SHALL BE COPPER, THWN/THHN, #12 AWG MINIMUM UNLESS <br />OTHERWISE NOTED ON PLANS. ALL CONDUCTORS SHALL BE RUN IN CONDUIT, 1/2" MINIMUM <br />TRADE SIZE UNLESS OTHERWISE NOTED ON PLANS. <br />7. PROVIDE A TYPEWRITTEN PANEL DIRECTORY FOR EACH PANEL. CONTRACTOR IS ALSO <br />RESPONSIBLE FOR BALANCING THE LOADS ON THE PHASES UNDER NORMAL CONDITIONS. <br />8. THE CONTRACTOR SHALL SATISFACTORILY REPAIR OR REPLACE EQUIPMENT OR AREAS <br />DAMAGED AS A RESULT OF HIS WORK. <br />9. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE EQUAL TO "LITTLEFUSE" <br />UNLESS NOTED OTHERWISE. <br />10. APPLIANCE ELECTRICAL LOCATION AND CONNECTIONS TO BE MADE IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />11. FINAL LOCATION OF ALL ELECTRICAL RECEPTACLES AND TELEPHONE AND CABLE <br />TELEVISION JACKS TO BE COORDINATED WITH ARCHITECT PRIOR TO ROUGH -IN FOR EXACT <br />LOCATION. <br />12. ALL ELECTRICAL DEVICES TO COMPLY WITH ADA AND FLORIDA ACCESSIBILITY CODE. <br />13. WHEN APPLICABLE, ALTERNATE EMERGENCY LIGHTING CIRCUITS SO THAT FAILURE OF A <br />CIRCUIT BREAKER DOES NOT LEAVE THE AREA IN TOTAL DARKNESS. <br />14. GROUND BUS BAR IN TELCOM ROOM WILL BE LOCATED BY THE <br />PROTECTORS. <br />15. PROVIDE 3/4" CONDUIT FOR A/C CONTROL WIRES. <br />16. CONDUITS SHALL NOT BE EXPOSED. <br />17. ALL ELECTRICAL WORK SHALL BE COORDINATED WITH ALL DISCIPLINES THROUGHOUT <br />THE ENTIRE PROJECT. <br />19. PROVIDE A GROUND WIRE AT EVERY CIRCUIT, SIZED PER PHASE WIRES AND NEC <br />250. <br />20. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS AND <br />ANY OTHER ITEM AS REQUIRED FOR THE WORK AS SHOWN ON THESE PLANS AND MUST <br />MAINTIAIN PROPER INSURANCE FOR THE DURATION OF THE WORK. <br />21. CONTRACTOR MUST VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR <br />TO ANY INSTALLATION OR FABRICATION. COORDINATE ALL WORK BEFORE ROUGH -IN OF <br />ALL RECEPTACLES, DATA JACKS, LIGHT SWITCHES, ETC. WITH FURNITURE PLANS, <br />21. CONTRACTOR MUST VERIFY ALL ROOM DIMENSIONS PRIOR TO EQUIPMENT <br />INSTALLATIONS TO MEET ALL CODE CLEARANCES. ANY DISCREPANCIES THAT WILL NOT <br />ALLOW PROPER CLEARANCES SHALL BE SUBMITTED TO THE A/E PRIOR TO INSTALLING <br />EQUIPMENT. <br />22. A 20 A SINGLE PHASE, 125V RATED RECEPTACLE OUTLET SHALL BE INSTALLED <br />WITHIN 25 FT OF THE AIR CONDITIONING EQUIPMENT AS PER ARTICLE 210.63 NEC. <br />23. FLOOR BOXES WHERE REQUIRED, MUST BE RESOURCE RFB SERIES RECESSED <br />FLOOR BOX BY WIREMOLD (SLAB ON GRADE), WITH BRUSH ALUMINUM TRIM. <br />LOCATION OF <br />ENTRANCE MI <br />120/208V, 3i <br />400A MAIN D <br />SERVING PRO <br />OVERALL PLAN <br />NOT TO SCALE <br />LOCATION OF EXISTING UTILITY <br />COMPANY "PROGRESS ENERGY" <br />SERVICE TRANSFORMER <br />FIRE <br />FACILITY <br />(STING STUBBED <br />UITS <br />I,L.„ nORK <br />VERIZON DATA AND CABLE <br />PICKUP POINTS RUN ALONG <br />BACK OF BUILDING. <br />CONTRACTOR MUST COORDINATE <br />WITH LOCAL VERIZON <br />REPRESENTATIVE FOR ANY <br />CONNECTIONS REQUIRED. <br />Project <br />HUMANA- ZEPHYRHILLS, <br />FLORIDA - GUIDANCE <br />CENTER <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FLORIDA 33541 <br />Prepared for <br />HUMANA INC. <br />Contract No: 12,01622.00 <br />HOK <br />One Tampa City Center, Suite 1800 <br />Tampa, FL 33602 USA <br />t +1 813 229 0300 f +1 813 223 7116 <br />FL Reg: AAC001139 <br />All reproduction & intellectual property rights reserved © 2012 <br />In Association with <br />SDM Consulting Engineers <br />MEP Engineer <br />135 Almeria Ave. <br />Coral Gables, FL 33134 <br />305.446.2788 <br />www.sdmcorp.com <br />Key Plan <br />C' <br />Professional Seals <br />ERNESTO ALOMA JOSE I. MARTINEZ <br />P.E. 53823 - P.E. 53779 <br />No. Issue Description YYYY-MM-DD <br />01 50% CONSTRUCTION DOCUMENTS 06.15.2012 <br />02 BID SET 06.29.2012 <br />03 ISSUE FOR PERMIT 07.27.2012 <br />No. Revision Description YYYY-MM-DD <br />1 ADDENDUM 1 2012-07-09 <br />2 ADDENDUM 2 2012-07-19 <br />Drawn by SDM Reviewed by SDM <br />Project No 12.01622.00 <br />Sheet Title: <br />LEGEND, NOTES AND <br />OVERALL PLAN <br />Original drawing is 36 x 24 Do not scale contents of this drawing <br />Sheet Number <br />