a <br />m <br />N <br />COMMU <br />GREETEf <br />PARTITION SCHEDULE <br />IA PARTITION SCHEDULE <br />STUD SPACING <br />DESCRIPTION SSMA # (IN) i MAX DEFLECTION MAX HT STC THICKNESS DETAIL REF. <br />NON -RATED 3 5/8" 362S125-33 16 U240 17' - 5" 40 4 7/8" <br />METAL STUDS, FULL <br />HEIGHT [SLAB -TO -SLAB] 1 <br />WITH ONE LAYER 5/8" <br />GYPBOARD EACH SIDE. <br />B03N NR NR NON -RATED 3 5/8" 362S125-33 16 U240 17' - 5" 40 4 7/8" <br />METAL STUDS. FULL <br />HEIGHT [SLAB -TO -SLAB]' <br />WITH ONE LAYER 5/8" <br />GYPBOARD EACH SIDE. j <br />CO3 NR NR 3 5/8" METAL STUDS 362S125-33 16 L/240 17' - 5" 40 4 7/8" <br />WITH ONE LAYER 5/8" <br />GYPBOARD EACH SIDE <br />(PARTITION TERMINATES <br />6" ABOVE CEILING). <br />TYPE FIRE RATING UL # <br />B03 NR NR <br />PARTITION LEGEND <br />PARTITION TYPE (SEE PARTITION SCHEDULE) <br />INSULATION TYPE, WHERE OCCURS (SEE INSULATION TYPES) <br />KEYNOTE <br />-GLAZING TYPE <br />NEW CONSTRUCTION <br />FLOOR TO CEILING WINDOW <br />PARTIAL HEIGHT WINDOW (WITH SILL) <br />--DOOR TAG (DOOR NUMBER BASED ON ROOM NUMBER <br />WITH ALPHA SUFFIX IF MULTIPLE) <br />EXISTING CONSTRUCTION TO REMAIN <br />NEW 1 HR FIRE RESISTANT RATED PARTITION <br />NEW 2HR FIRE RESISTANT RATED PARTITION <br />EXISTING 1HR FIRE RESISTANT RATED PARTITION <br />EXISTING 2HR FIRE RESISTANT RATED PARTITION <br />FE FIRE EXTINGUISHER <br />NEW MILLWORK WITH OVERHEAD CABINETS <br />AREA N.I.C. <br />FEC <br />FIRE EXTINGUISHER CABINET <br />PF R <br />FIRE PROTECTION RISER CABINET <br />+42" <br />- INDICATES MOUNTING HEIGHT A.F.F. <br />SHEET NOTES <br />1. SEE AN -SHEET SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS. <br />2. PARTITIONS DIMENSIONED TO FINISH FACE U.O.N. DO NOT ADJUST DIMENSIONS INDICATED AS "CLEAR" WITHOUT WRITTEN <br />DIRECTION FROM ARCHITECT. DRAWINGS SHALL NOT BE SCALED. VERIFY ALL DIMENSIONS AND EXISTING AS BUILT FIELD <br />CONDITIONS, INCLUDING FIELD MEASUREMENTS PRIOR TO START OF WORK, NOTIFY ARCHITECT WHERE DISCREPANCIES OCCUR. <br />3. USE TYPE "X" GWB ON FIRE RATED PARTITIONS. <br />4. USE CEMENTITIOUS BACKER BOARD ('DUROCK') OR EQUAL AT PARTITIONS SCHEDULED TO RECEIVE CERAMIC TILE (U.O.N.). SEE <br />FINISH PLAN FOR LOCATION OF TILE. <br />5. SEE A-8 DETAIL SHEET SERIES FOR TYPICAL PARTITION DETAILS, EXTENTS OF FRAMING AND FINISHES. <br />6. WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT, BRACE TO ADJACENT STRUCTURE. SEE A-8 DETAIL SHEET SERIES. <br />7. FIRE SAFE PENETRATIONS AT FIRE RESISTANT RATED PARTITIONS PER APPLICABLE UL ASSEMBLY. SEE A8 SHEET SERIES FOR <br />DETAILS. <br />8. MAINTAIN INTEGRITY OF EXISTING FIRE RESISTANT RATED ASSEMBLIES FOR ALL PENETRATIONS. <br />9. PROVIDE BLOCKING AS REQUIRED AT LOCATIONS INCLUDING, BUT NOT LIMITED TO: GRAB BARS, SHELVING, OVERHEAD <br />CABINETS, SIGNAGE, TOILET ROOM ACCESSORIES, WALL MOUNT. EQUIPMENT, ETC. <br />10. REFER TO A-2 SHEET SERIES FOR POWER & SIGNAL DEVICE LOCATIONS, <br />11. PROVIDE LEVEL 4 FINISH U.O.N. PROVIDE LEVEL 5 FINISH AT ALL PARTITIONS TO RECEIVE WALL COVERING. REFER TO FINISH <br />PLANS FOR LOCATIONS AND ADDITIONAL INFORMATION. <br />12. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS, DETAILS TAKE PRECEDENCE OVERALL, NOTIFY <br />ARCHITECT IN WRITING WHERE DISCREPANCIES OCCUR. <br />13. ALL EXPOSED OUTSIDE GYPSUM BOARD CORNERS SHALL HAVE A CONTINUOUS METAL CORNER BEAD. <br />14, DIMENSIONS TAKEN FROM PERIMETER EXTERIOR WINDOW WALL ARE TAKEN FROM THE INSIDE FACE OF THE VERTICAL MULLION. <br />DIMENSIONS MARKED VERIFY IN FIELD, SHALL BE VERIFIED PRIOR TO START OF WORK UNLESS OTHERWISE NOTED. <br />15. CONTRACTOR SHALL COORDINATE WORK WITH HVAC, MECHANICAL, ELECTRICAL, PLUMBING, DESIGN BUILD FIRE PROTECTION <br />AND STRUCTURAL DRAWINGS AND REPORT TO THE ARCHITECT DISCREPANCIES FOR CORRECTION AND ADJUSTMENT PRIOR TO <br />START OF WORK. NO ALLOWANCE WILL BE MADE FOR INCREASED COST DUE TO THE CONTRACTOR'S LACK OF COORDINATION, <br />16, PATCH FLOOR AND WALL AREAS DAMAGED DUE TO NEW CONSTRUCTION OR WHERE PENETRATIONS HAVE BEEN MADE FOR <br />MECHANICAL, ELECTRICAL AND PLUMBING WORK. FIRESAFE AT UL RATED ASSEMBLIES CONSISTENT WITH EXISTING UL RATING. <br />17. WHERE EXISTING RATED ASSEMBLIES ARE SHOWN, CONTRACTOR IS REQUESTED TO FIELD VERIFY AS BUILT FIELD CONDITIONS <br />TO CONFIRM RATINGS SHOWN. IF NON -COMPLIANT CONDITIONS ARE FOUND, DEMO AND REPLACE WITH NEW EQUIVALENT UL <br />ASSEMBLY, OR REPORT FINDINGS TO OWNER/ARCHITECT IN WRITING WHO WILL PROVIDE WRITTEN DIRECTION. <br />18. PATCH AND REPAIR ALL EXISTING PARTITIONS AFTER DEMOLITION WHERE DAMAGE HAS OCCURRED AT UNPROTECTED <br />LOCATIONS. PLEASE NOTE THAT DEMOLITION ACTIVITY MAY OCCUR BEYOND WORK LIMITS SHOWN ON DEMOLITION PLAN DUE <br />TO CONCEALED CONDITIONS. <br />19. ALL LIGHT GAUGE COLD FORMED METAL FRAMING SHALL MEET OR EXCEED PROPERTIES SPECIFIED FOR THE CORRESPONDING <br />MEMBER SIZE IN STEEL MANUFACTURERS ASSOCIATION [SSMA] PRODUCT TECHNICAL INFORMATION [ICC-ES REPORT NO. <br />ER-4943P] AND SHALL COMPLY WITH APPLICABLE AMERICAN SOCIETY FOR TESTING AND MATERIALS, AMERICAN IRON AND <br />STEEL INSTITUTE S100 AND SPECIFIED TRUE GAUGE FLAT STEEL MIL THICKNESS THAT ONLY TRUE GAUGE FLAT STEEL CAN <br />SATISFY. USE OF "EFFECTIVE THICKNESS" COLD REDUCED AFTERMARKET EQUIVALENT PRODUCT (EQ) STUDS FURNISHED BY EQ <br />STUD MANUFACTURERS. VENDORS OR SUPPLIERS ARE NOT PERMITTED WITHOUT EXCEPTION. <br />KEY NOTES <br />NO. DESCRIPTION <br />102 EXISTING GLASS PARTITION TO REMAIN. REMOVE ONLY SOLID GREEN FILM BLOCKS. <br />103 REMOVE EXISTING TV MONITORS AND REHANG IN EXISTING LOCATION. SEE ELEVATION FOR REFERENCE. <br />104 <br />LAY ACOUSTICAL BATTING 24" ON BOTH SIDES OF PARTITION ABOVE CEILING. <br />105 <br />EXISTING N MONITOR TO BE RELOCATED. SEE ELEVATION FOR REFERENCE. <br />106 <br />107 <br />_ <br />ADD UNDERCABINET LIGHTING, INSTALL NEW MILLWORK, BACKSPLASH, COUNTERTOP, FIXTURES, AND EQUIPMENT. <br />MAINTAIN PLUMBING LOCATION. <br />PREPARE FOR TV MONITOR TO BE INSTALLED IN THE FUTURE. SEE ELEVATION FOR REFERENCE. <br />108 <br />EXISTING ELECTRICAL PANELS TO REMAIN. <br />109 <br />NEW GLASS WALL. HEADER TO MATCH OTHER EXISTING CONDITION. <br />112 <br />PARTITION TO HAVE LEVEL 5 FINISH. <br />306 <br />_ <br />NEW UNDER CABINET LIGHTING. <br />INSULATION TYPES <br />TYPE: <br />MINERAL WOOL INSULATION <br />A <br />1 112" K <br />B <br />2" L <br />C <br />2112" M <br />D <br />3112" N <br />E <br />EXISTING INSULATION TO REMAIN (ANY TYPE) P <br />F <br />6" <br />MINERAL WOOL THERMAL INSULATION <br />G <br />2112" (R-8) R <br />H <br />3112" (R-9) S <br />J <br />61/4" (R-18) T <br />FIBERGLASS BATT ACOUSTICAL INSULATION <br />1 1 /2" <br />2" <br />21/2" <br />31/2" <br />61 /4" <br />FIBERGLASS BATT THERMAL INSULATION <br />21/2" (R-8) <br />3112" (R-11) <br />61/4" (R-19) <br />�iL7r,1!1!, <br />2017 - Humana <br />Zephyrhills Guidance <br />Center <br />7920 GALL BLVD. <br />ZEPHYRHILLS, FL <br />33541 <br />GEORGE W. DE LA HOZ <br />FL LICENSE #AR0016664 <br />1 3 ISSUE FOR CONSTRUCTION 04.18.2018 <br />Delta Issue Description Date <br />r. <br />11 <br />INTERIOR <br />ARCHITECTS, P.C. <br />M I A M I <br />2100 PONCE DE LEON BLVD <br />SUITE 1090 <br />CORAL GABLES, FLORIDA 33134 <br />TEL 786-405-0230 <br />c;2018 INTERIOR ARCHITECTS, P.C., LICENSE #AA26001062. A NEW YORK <br />PROFESSIONAL SERVICES CORPORATIOALL DRAWINGS AND WRITTEN <br />MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK <br />OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, <br />OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. <br />Drawn: TEAM Check: Checker Owner Approval: <br />Job No:9900019.00 Scale: As indicated <br />Title: PARTITION PLAN <br />Sheet: ■ <br />