Laserfiche WebLink
N <br />N <br />O <br />u� <br />C <br />N <br />O <br />ro <br />V7 <br />%" EXP. ISOLATION JOINT <br />6 <br />SEE DETAIL -THIS SHEET -0„ MAX PLASTIC CONTROL 0 <br />JT. FORMER 2'-0" TYP. 2'-0" MIN. <br />= WIDTH WIDTH WIDTH LL <br />�- %^ a PLASTIC CONTROL TONGUE & GROOVE <br />_ JT. FORMER METAL FORM SPLICE SPLICE SPLICE A DO C <br />©Q NO WW - <br />u -71 74 THRU JOINT %4" MIN. / \ <br />p RECTANGULAR ¢ ? <br />3 <br />LU <br />w V <br />h. <br />(Y <br />v �^ -, °.;' � ° O OR ROUND � � <br />w f G I- K "-h I } e-.I�- - y w Cw� PNG \� � 1\ � � 4 V <br />° 1..- l J <br />CONSTRUCTION JOINTS "- ' - _ - _ _ -- _ <br />SEE DETAIL -THIS SHEET III -I - --1 1 I_I, II I-1 I--1I ! t I-1I 1 1-__I -1 I III-III-1 1=1 I I III 1 L 0 <br />III, III-1 I- -_--1 1=III ;III I 1-I, <br />6 MIL VAPOR BARRIERT u <br />O O O O Is 0 CUT BARS ON ro <br />w w ua w w w 10, EA. SIDE OF C <br />0, OPENING <br />g g PROVIDE CONTROL JOINTS AT ALL COLUMNS AND OR REINFORCING - SEE <br />METHOD OF CASTING LANES 20'-0" c/c. USE PREMOLDED STRIPS SCHEDULE 0 <br />30'-0" CONSTRUCTION JOINT MAY REPLACE CONTROL JOINT. SAW CUT PLAN 4J <br />NOTES: MAX. JOINT MAY BE USED 1N LIEU OF PREFORMED STRIP. <br />1. LANES SHALL BE CAST IN METHOD INDICATED WIDTH FOOTING WIDTH FOOTING 3 2-#4 AT rL OF SLAB tti <br />2. LANES TO BE DIVIDED BY CONSTRUCTION JOINTS AT (L OF COLUMNS AND O <br />SUB -DIVIDED AT A MAXIMUM OF 30'-0° CENTERS. O CONTROL JOINT DETAIL B CONSTRUCTION JOINT DETAIL <br />3. IN AREA WHERE COLUMNS DO NOT OCCUR, PROVIDE CONSTRUCTION AND/OR _� =!= <br />CONTROL JOINTS AS SHOWN. <br />' '1 -1 -il SLAB ON GRADE r <br />4. ALLOW 24 HOURS BETWEEN ADJACENT LANE PLACEMENT. A SECTION *' <br />1 Concrete Slab -On -Grade 2 Slab -On -Grade Joint Detail 3 Footing Intersection Reinforcing K4 Opening In Slab -On -Grade <br />S• O� SCALE: %4" = P-0" S 3.O "� SCALE: %4' = 1'-0" S 3.02 SCALE: %4' = 1'-0" S 3.02 SCALE: %4' = 1'-0" E <br />v <br />ro <br />H <br />w <br />0. <br />W G. J <br />PIPE THRU N Z 10'-0" MIN. <br />FOOTING <br />WALL WZ O GROUND LINE 'C) <br />ate= <br />a w !- A <br />° 0 NG <br />NOTE: STEPPED FOOTING FOR UTILITIES c <br />BACKFILL <br />0 PER SPECS WHEN REQUIRED OR AS REQUIRED ON PLAN. E <br />4 <br />e� <br />n [ 1'-6" ` 2 TRENCI� FOOTING FINISH GRADE <br />r. FOOTING MIN. 1 -I C <br />EXCAV -1 � .= ! I I -_, � n MATCH SCHED'p TRANSVERSE � <br />N.B.O.F. ELEV. ° ' BAR SIZE & SPACING E <br />00 <br />n <br />EXISTING UTILITY, SEE <br />CONTINUE BOT. <br />O = ° CIVIL DRAWINGS FOR REINF. OF SCHED. <br />Z = - BOTTOM OF TRENCH 2 \ SIZE &LOCATION. FOUNDATION SIZE <br />m w - EXCAVATION SHALL NOT17 <br />a <br />EXTEND BELOW THIS LINE ° a & SPACING <br />° Q. <br />�•� ° ° 1J <br />DOF Z_5 L <br />SLEEVE COMPACTED FILL 90% DENSITY ~p <br />SLEEVES 2 LARGER EQUAL CONTRACTOR TO LOCATE O z L <br />• , ., w <br />THAN O.D. OF PIPES D + 1'-6" BOTTOM OF FOOTING ELEVATION © - %^^ <br />Uj <br />NOTE: THE CONTRACTOR SHALL BE TO AVOID SURCHARGING ON <� ry p LU 3 <br />PROVIDE SLEEVE AND CONCRETE AS SHOWN; RESPONSIBLE FOR SHORING, SHEATHING OR EXISTING SUBGRADE UTILITIES. \ 2' 0" LAP > <br />MORE THAN 3'-0" COMPACT BACKFILL OVER PIPE OTHERWISE MAINTAINING THE SIDES OF THE SPLICE Q <br />TO 90% AS APPROVED BY SOILS ENGINEER, OR EXCAVATION FROM CAVE-INS UNTIL ALL E <br />USE STEPPED FOOTING BELOW PIPE. BACKFILL IS COMPLETED PER SPECIFICATIONS EXTEND BOT. BARS 0 <br />TO 3" OF END U <br />+j <br />Typical Excavation Typical SteppedIII <br />,p <br />r Perpendicular To Footing 6 Excavation Parallel To Footing 7 Footing Parallel To Existing Utilities g Footing Reinforcing Detail <br />S+(�� SCALE: N.T.S. (� "� .02 SCALE: N.T.S. S .02 SCALE: %4" = 1'-0" 3.02 SCALE. 3/4" = 1'-0" +�+ <br />0 <br />lA <br />0 <br />Reinforced Concrete Footing Schedule <br />MARK <br />SIZE <br />DEPTH <br />REINFORCING <br />REMARKS <br />GRAVITY LOADING <br />(2,500 PSF Allowable Bearing) <br />BOTTOM <br />TOP <br />TRANSVERSE <br />MF-2.0 <br />2'-0" X 2'-0" <br />1'-8" <br />(3) #5 EACH WAY <br />----- <br />----- <br />MONOLITHIC FOOTING <br />PDL+LL < 10.00 Kips <br />MF-2.5 <br />2'-6" X 2'-6" <br />114" <br />(3) #5 EACH WAY <br />--"` <br />----- <br />MONOLITHIC FOOTING <br />PDL+LL 515.50 Kips <br />MF-3.0 <br />Y-0" X 3'-0" <br />1'-8" <br />(4) #5 EACH WAY <br />-`-`- <br />----` <br />MONOLITHIC FOOTING <br />PDL+LL < 22.50 Kips <br />MF-4.0 <br />4'-0" X 4'-0" <br />1'-8" <br />(5) #5 EACH WAY <br />----- <br />----- <br />MONOLITHIC FOOTING <br />PDL+LL <_ 40.00 Kips <br />TE-0.7 <br />8" CONT. <br />1'-0" <br />(1) #4 CONT. or (1) PT CABLE <br />----- <br />----` <br />THICKENED EDGE <br />WDL+LL < 1.00 KLF <br />TE-1.0 <br />1'-0" CONT. (MIN.) <br />1'-8" (MIN.) <br />(2) #4 CONT. or (1) PT CABLE <br />(1) #4 CONT. <br />----- <br />THICKENED EDGE <br />WDL+LL s 2.50 KLF <br />TE-1.3 <br />1'-4" CONT. (MIN.) <br />1'-8" (MIN.) <br />(2) #5 CONT. or (1) PT CABLE <br />---- - <br />----- <br />THICKENED EDGE <br />WDL+LL <_ 3.25 KLF <br />TE-1.5 <br />1'-6" CONT. (MIN.) <br />1'-8" (MIN.) <br />(2) #5 CONT. or (1) PT CABLE <br />(1) #4 CONT. <br />---`- <br />THICKENED EDGE <br />WDL+LL <_ 3.75 KLF <br />TE-2.0 <br />2'-0" CONT. (MIN.) <br />1'-8" (MIN.) <br />(3) #5 CONT. or (1) PT CABLE <br />----- <br />..... <br />THICKENED EDGE <br />WDL+LL <_ 5.00 KLF <br />TS-1.5 <br />1'-6" CONT. (MIN.) <br />1'-0" (MIN.) <br />(2) #5 CONT. or (1) PT CABLE <br />(1) #4 CONT. <br />----- <br />THICKENED SLAB <br />WDL+LL < 3.75 KLF <br />TS-2.0 <br />2'-0" CONT. (MIN.) <br />1'-0" (MIN.) <br />(3) #5 CONT. or (1) PT CABLE <br />--- - <br />"'-` <br />THICKENED SLAB <br />WDL+LL < 5.00 KLF <br />TS-2.5 <br />2'-6" CONT. (MIN.) <br />1'-0" (MIN.) <br />(4) #4 CONT. or (1) PT CABLE <br />----- <br />----' <br />THICKENED SLAB <br />WDL+Ll_ 5 6.25 KLF <br />4-1 <br />ft1 <br />#4 CONT. @ TOP OF CURB w/ L CURB WIDTH AS REQUIRED <br />CORNER BARS AS REQ'D., TYP. 6 MIN 8" MAX.. <br />d <br />oG V1 <br />1 #4 CONT. IN CONCRETE SLAB <br />SLAB, TYP. co < PER PLAN, TYP. <br />tA <br />° o <br />#4 DOWELS w/ STD. HOOK <br />t� BOTTOM @ 24" O.C., TYP, N <br />N CURB C <br />144 CONT. AROUND PERIMETER. 4J <br />LAP 1'-6" AT CORNERS, TYP. (U.N.O.) n4 <br />SEE ARCH. U <br />V CLR. 0 <br />CONCRETE SLAB <br />PER PLAN, TYP. <br />_ sA <br />=1 I I I I=1 L <br />v <br />STD. 900 HOOK, TYF�� � � � �- 6x6-W1.4xW1.4 W.W.F. #4 DOWELS AT N <br />1 #4 CONT. IN SLAB, TYP. 16" � I <br />NOTES: ISLAND C <br />1. SEE ARCH FOR SIZE AND Lj <br />..�..` <br />NOTES: LOCATION OF CURBS, TYP. C <br />• SEE CURB LET. FOR #4 HORIZ. <br />1. IF THE CONTRACTOR CHOOSES TO USE THE POST -TENSIONED SLAB V.E. OPTION, THE DELEGATED POST -TENSION SPECIALTY ENGINEER MUST SUBMIT COMPLETE SIGNED & SEALED CALCULATIONS FOR ALL FOOTING/SLAB DESIGNS AS 2. PROVIDE INSERTS AS REQ'D BY <br />WELL AS SIGNED & SEALED SHOP DRAWINGS TO THE ARCHITECT & ENGINEER OF RECORD FOR REVIEW & APPROVAL PRIOR TO CONSTRUCTION. CALCULATIONS MUST ADDRESS BOTH GRAVITY LOADS & WIND LOADS APPLIED TO THE ARCH & MECH. DRAWINGS, TYP. BAR REQUIREMENTS <br />• SLAB REINF. NOT SHOWN FOR v <br />BUILDING INCLUDING CONCENTRATED LOADS AT ISOLATED FOOTINGS AS WELL AS UNIFORMLY DISTRIBUTED ALONG THE CONTINUOUS INTERIOR & EXTERIOR FOOTINGS. CLARITY (� <br />2. THE SIZE & REINFORCING FOR ISOLATED SPREAD FOOTINGS NOTED ON THE FOUNDATION PLANS MUST BE MAINTAINED & MAY NOT BE REDUCED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM SC&D. <br />3. ALL FOUNDATION DESIGNS MUST COMPLY w/ ALL APPLICABLE CODES AS WELL AS THE RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL ENGINEERING REPORT NOTED ON SHEET S3.01, TYP. ANY DEVIATIONS FROM THESE N <br />RECOMMENDATIONS MUST BE ACCOMPANIED BY A WRITTEN AUTHORIZATION FROM THE GEOTECHNICAL ENGINEER OR THE SUBMITTAL WILL BE REJECTED. <br />Typical Concrete Curbs & . <br />g Reinforced Concrete Footing Schedule 1O Island @ Slab -On -Grade v <br />T <br />SCALE: N.T.S. SCALE: Y4" = F-0" <br />J � <br />0 <br />3 <br />a <br />r <br />m <br />0 <br />w <br />m <br />i <br />FORUME <br />N ARCHITECTURE & <br />z INTERIOR DESIGN, INC. <br />z PLANMVG I MMI-FMCME I INTMM l IGW <br />w <br />0 <br />a 237 S. Westmonte Drive, Suite 220 <br />z Altamonte Springs, FL 32714 <br />co 407.830,1400 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />City of Zephyrhills, FL <br />Il ; <br />2965 WEST STATE ROAD 434, SUITE 100 LONGWOOD, FL 32779 <br />TEL 407/682.2086 • FAX 407/682-2386 <br />WWW.SCD-ENG.COM <br />®®®®peoaaioeo,p®®®® <br />N ° <br />91 <br />44 <br />O TA OF <br />e <br />Robert C. Scroggins, P,E. <br />FL Registration No. 56158 <br />This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date <br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not <br />considered signed and sealed and the signature must be verified on any electronic copies, <br />SET DISTRIBUTIONS: <br />12/16/2021 OWNER REVIEW SET <br />02/17/2022 PERMIT SET <br />z <br />z <br />2 <br />W <br />0 <br />us <br />� SHEET REVISIONS: <br />z <br />z <br />c6 <br />S <br />U - -- - <br />a <br />a <br />o <br />r <br />tu <br />EL <br />o <br />W <br />� - - <br />- -- -- -- <br />z <br />Lu <br />-- - --_ _. <br />z <br />o <br />Lt <br />G <br />EDITED BY: RCS, TLw <br />SC&D PROJECT NO. 21-020 <br />g FORUM PROJECT NO. 4097 <br />W <br />W <br />W <br />U <br />z <br />V) <br />W Structural Sections & <br />0 <br />Details <br />ix <br />w <br />z <br />U <br />UJ <br />U <br />S3.02 <br />F <br />I <br />0 <br />U_ <br />