Laserfiche WebLink
t <br />e <br />Typical Sheet Notes <br />Floor & Roof Framing Plans <br />A. SEE SHEET "S3.01" FOR GENERAL STRUCTURAL NOTES, TYP. <br />B. SEE SHEET "S4.00.1" FOR WOOD BEAM/HEADER SCHEDULE, TRUSS FRAMING DESIGN <br />CRITERIA, & TYPICAL BUILT-UP WOOD STUD COLUMN DETAILS, TYP. <br />C. SEE SHEET "S4.04.1" FOR FLORIDA BUILDING CODE COMPONENT & CLADDING DESIGN <br />WIND PRESSURE TABLE, TYP. <br />D. EXTERIOR WALL SHEATHING TO BE %6' CDX PLYWOOD or O.S.B. FASTENED TO WOOD <br />FRAMING w/ 8d RING SHANK NAILS @ 6" O.C. ALONG PANEL EDGES & 12" O.C. IN <br />FIELD, TYP. (U.N.O.) <br />G. "SW-#" INDICATES WOOD STUD SHEAR WALL. REFER TO SHEET "S4.04.2" FOR 4-STORY <br />SHEAR WALL SCHEDULE & DETAILS, TYP. <br />H. REFER TO SHEETS "S4.04.3" TO "S4.04.4" FOR TYPICAL WOOD WALL FRAMING <br />ELEVATIONS w/ STRAPPING & ANCHORAGES, TYP. <br />I. GIRDER TRUSS ACROSS CORRIDOR TO BE DESIGNED TO ALLOW MECHANICAL DUCT <br />TO PASS THROUGH. COORDINATE w/ M.E.P. DRAWINGS, TYP. <br />J. ALL MASONRY WALLS TO BE 8" CMU (f m = 1,500 PSI) w/ 9 GA. HORIZ. LADDER REINF. <br />@ 16" O.C. & HAVE #5 VERTICAL BAR @ 32" O.C. IN SOLID GROUTED CELL, TYP. <br />PROVIDE 48 BAR O LAP w/ VERTICAL REINF. ABOVE BOND BEAM WHERE REQ'D., TYP. <br />SEE SHEET "S3.05" FOR TYPICAL MASONRY DETAILS <br />CONTRACTOR NOTE: <br />THRESHOLD BUILDING INSPECTIONS ARE CONSIDERED ADDITIONAL INSPECTIONS TO THE <br />INSPECTIONS REQUIRED ON THE BUILDING PERMIT. THE CONTRACTOR SHALL BE <br />REQUIRED TO SCHEDULE REGULAR INSPECTIONS THROUGH THE LOCAL <br />BUILDING INSPECTION DEPARTMENT. SEE SHEET S3.01A FOR THRESHOLD <br />INSPECTION PLAN. <br />1. FIN. 2nd FLOOR ELEVATION = U'40%", TYP, <br />FLOOR TRUSS BEARING ELEVATION = 10'-1Y8", TYP. <br />2. TRUSS SHOP DRAWINGS: PROVIDE SHOP DRAWINGS SHOWING TRUSS LAYOUT, <br />PROFILES, CONNECTIONS, & LOAD DIAGRAMS FOR FLOOR TRUSS SYSTEM SIGNED & <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. <br />3. FLOOR TRUSSES: PROVIDE ENGINEERED, PRE -FABRICATED 2x WOOD TRUSSES FOR <br />LOADS, SPANS, & CONDITIONS SHOWN. SPACE TRUSSES @ 24" O.C. MAX. & AS <br />REQUIRED BY TRUSS MANUF. PROVIDE ALL REQUIRED INFILL FRAMING, BLOCKING, <br />& BRACING AS REQ'D. TO FRAME ENTIRE FLOOR -CEILING ASSEMBLY. COORDINATE <br />TRUSS SPACING w/ MECHANICAL FIXTURES & EQUIPMENT LOCATIONS. <br />4. TYPICAL UNIT FLOOR FRAMING: 20" DEEP ENGINEERED WOOD TRUSSES SPACED @ <br />24" O.C. (MAX.) COORD. LOCATIONS w/ ARCH. & M.E.P. DRAWINGS, TYP. <br />5. TYPICAL UNIT FLOOR DECKING: PROVIDE GYP-CRETE TOPPING PER ARCH. DWGS. <br />OVER 3/4" TONGUE & GROOVE, APA SPAN RATED, CODE CERTIFIED O.S.B. DECKING. <br />GLUE & NAIL TO TRUSS TOP CHORDS w/ 8d RING SHANK NAILS @ 6" O.C. ALONG <br />PANEL EDGES & 12" O.C. INFIELD, TYP. <br />6. BALCONY FLOOR FRAMING: 18" DEEP (MAX.) ENGINEERED WOOD TRUSSES w/ <br />SLOPED TOP CHORD SPACED @ 24" O.C. (MAX.) w/ SLOPED TOP CHORDS AS REQ'D, <br />COORD. LOCATIONS w/ ARCH. & M.E.P. DWGS., TYP. <br />7. BALCONY FLOOR DECKING: PROVIDE IY2' MIN. (3" MAX.) LIGHTWEIGHT CONCRETE <br />TOPPING (115 PCF MAX.) PER ARCH. DWGS. OVER 3/4" TONGUE & GROOVE, APA SPAN <br />RATED, CODE CERTIFIED PLYWOOD OR O.S.B. DECKING. GLUE & NAIL SHEATHING <br />TO TRUSS TOP CHORDS w/ 8d RING SHANK NAILS @ 6" O.C. ALONG PANEL EDGES & <br />12" O.C. INFIELD, TYP. <br />8. FLOOR TRUSS DRAFTSTOP: PROVIDE DRAFTSTOPPING AS SPECIFIED ON ARCH. <br />DWGS. IN FLOOR TRUSS ABOVE TENANT SEPARATION WALLS, BREEZEWAY WALLS & <br />CORRIDOR WALLS, TYP. <br />0 Key Notes <br />2nd Floor & Low Roof Framing Plan (4 Story Building) <br />9. EXTERIOR LOAD -BEARING STUD WALLS @ 2nd FLOOR: <br />PROVIDE 2x6 VERTICAL STUDS @ 12" O.C. w/ 2x6 SOLID BLOCKING @ 5-0" (MAX.) <br />PROVIDE CONT. DBL. 2x6 TOP PLATE & CONT. 2x6 BOTTOM PLATE FASTENED TO <br />FLOOR FRAMING w/ 0.148"Ox3Y4" NAILS @ 12" O.C., TYP. <br />10. INTERIOR LOAD -BEARING STUD WALLS @ 2nd FLOOR: <br />PROVIDE DBL. 2x4 VERTICAL STUDS (FASTENED TOGETHER w/ 12d COMMON WIRE <br />NAILS @ 12" O.C. STAGGERED) SPACED @ 16" O.C., TYP. PROVIDE CONT. DBL. 2x4 <br />TOP PLATE & CONT. 2x4 P.T. PLATE FASTENED TO FLOOR FRAMING w/ 0.148" 00Y4" <br />NAILS @ 12" O.C., TYP. <br />11, LOAD -BEARING CMU WALLS @ 2nd FLOOR ELEVATOR: PROVIDE 8" CMU STACKED IN <br />RUNNING BOND w/ #5 VERT. REINF. IN SOLID GROUTED CELLS @ CORNERS, ENDS, <br />INTERSECTIONS, & SPACED @ 32" O.C. (MAX.), TYP. <br />12. INTERIOR NON -BEARING STUD WALLS: <br />PROVIDE 2x4 or 2x6 VERTICAL STUDS @ 16" O.C. w/ CONT. 2x TOP PLATE & CONT. <br />2x BOTTOM PLATE PER ARCH. DWGS., TYP. <br />13, ALL STUD WALL SILL PLATES & OTHER WOOD MEMBERS IN CONTACT w/ CONCRETE <br />OR MASONRY SHALL BE PRESSURE TREATED, TYP. <br />14. SHEARWALLS & TRUSSES: WHEN SHEARWALLS ARE PARALLEL w/ ROOF OR FLOOR <br />TRUSSES & NORMALLY SPACED TRUSSES DO NOT ALIGN w/ SHEARWALLS, PROVIDE <br />FULL HEIGHT INFILL TRUSSES OVER EACH SHEARWALL w/ VERTICAL MEMBERS @ 16" <br />O.C. MAX. ANCHOR TRUSSES TO SHEARWALLS & DECK SHEATHING AS NOTED ON <br />SHEARWALL SCHEDULES. ADJUST HEIGHT & SHAPE OF TRUSSES AS REQ'D. TO MATCH <br />DEFLECTION OF SPANNING TRUSSES. <br />15. STAIR FRAMING: PRE-ENGINEERED STEEL STAIRS w/ PRE -CAST CONCRETE TREADS. <br />SEE ARCH. DWGS. FOR REQUIRED LAYOUT & DIMENSIONS, TYP. SUBMIT COMPLETE <br />SHOP DRAWINGS & CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER <br />REGISTERED IN THE STATE OF FLORIDA TO ARCH. & ENGINEER FOR REVIEW & <br />APPROVAL. <br />16. STAIR LANDING FRAMING: PRE-ENGINEERED STEEL LANDING w/ (3" MAX.) <br />CONCRETE/METAL DECK. SEE ARCH. DWGS. FOR REQUIRED LAYOUT & DIMENSIONS, <br />TYP. SUBMIT COMPLETE SHOP DRAWINGS & CALCULATIONS SIGNED & SEALED BY A <br />PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA TO ARCH. & <br />ENGINEER FOR REVIEW & APPROVAL, TYP. <br />17. GIRDER TRUSS SUPPORT: PROVIDE (4) 2x MULTI -STUD WOOD POST FASTENED w/ <br />10d NAILS @ 12" O.C. STAGGERED EACH PLY UNDER BEARING POINTS OF ALL <br />PRE-ENGINEERED GIRDER TRUSSES TO FOUNDATION w/ CRUSH BLOCKS IN FLOOR <br />TRUSSES, TYP. (U.NO.) <br />18. ROOF TRUSSES: PROVIDE ENGINEERED, PRE -FABRICATED 2x WOOD TRUSSES FOR <br />LOADS, SPANS, & CONDITIONS SHOWN. SPACE TRUSSES @ 24" O.C. MAX. & AS <br />REQUIRED BY TRUSS MANUF. PROVIDE ALL REQUIRED INFILL FRAMING, BLOCKING, <br />& BRACING AS REQ'D. TO FRAME ENTIRE ROOF ASSEMBLY. PROVIDE ALL NECESSARY <br />SUPPORT CONDITIONS FOR FRAMING ATTACHED TO WOOD TRUSSES. SECURE <br />BEARING POINTS OF EACH TRUSS w/ GALVANIZED HURRICANE STRAPS AS SPECIFIED <br />& DETAILED. <br />19. ROOF SHEATHING: PROVIDE 5/" EXTERIOR GRADE, SPAN RATED, CODE CERTIFIED <br />O.S.B. SHEATHING w/ H-CLIPS AS REQ'D., TYP. <br />20. ROOF SHEATHING NAILING SCHEDULE: <br />• NAIL @ 6" O.C. AT DIAPHRAGM BOUNDARIES, OVER PERIMETER WALLS, AND AT <br />ALL RIDGES, HIPS,& VALLEYS. <br />• NAIL @ 12" O.C. ALL INTERIOR SUPPORTS AND ALL OTHER PANEL EDGES. <br />• UNBLOCKED DIAPHRAGM, USE 8d RING SHANK or 10d COMMON NAILS w/ 1%" <br />MINIMUM PENETRATION, TYP. <br />21. LOW ROOF TRUSS BEARING = VARIES SEE ARCH. DWGS. <br />CUNIT Cl UNIT 65 C4NIT 62 UNIT 62 C*�K)C� <br />UNIT A2 C*t�:) UNIT Al CUNIT Al C4NIT 64 CUNIT Bl C*f�:) <br />I '� Building Type I -Second Floor Framing Plan <br />S3.12) SCALE: 8" = 1'-0" <br />N <br />kA <br />0 <br />LL <br />v <br />L <br />3 <br />v <br />U <br />C <br />ro <br />L <br />0 <br />U <br />V <br />'0 <br />L <br />ro <br />ro <br />U <br />0 <br />v <br />L <br />4-1 <br />'U <br />C <br />,C <br />L <br />v <br />'0 <br />ro <br />V <br />0 <br />hhU <br />�111 <br />.Q <br />E <br />C <br />E <br />v <br />z <br />ro <br />U <br />a <br />a <br />ro <br />v <br />L <br />3 <br />a <br />E <br />0 <br />U <br />U <br />v <br />0 <br />L <br />a <br />h <br />JC <br />L <br />O <br />C <br />0 <br />+J <br />ro <br />U <br />w <br />'u <br />N <br />a <br />v <br />c <br />ro <br />m <br />a <br />v <br />r <br />++ <br />n <br />W <br />3 <br />0 <br />L <br />v <br />v <br />W <br />"v <br />D' <br />a1 <br />r <br />4. <br />0 <br />0 <br />v <br />v <br />0 <br />3 <br />Q <br />r <br />m <br />uj <br />m FORUMN <br />0 <br />ff <br />a. ARCHITECTURE & <br />Lo <br />z INTERIOR DESIGN, INC. <br />i PLANNING I ARCHTECIURE I INTERIOR DESIGN <br />ui <br />W <br />0 <br />O <br />F 237 S. Westmonte Drive, Suite 220 <br />z Altamonte Springs, FL 32714 <br />as 407.830.1400 <br />to <br />z <br />0 <br />W <br />X <br />6 <br />z <br />0 <br />1- <br />U <br />0 <br />0 <br />0. <br />0. <br />ul <br />i w <br />tx <br />r <br />z <br />a <br />Z <br />Z <br />O <br />W <br />0 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />City of Zephyrhills, FL <br />i <br />I pI <br />2965 WEST STATE ROAD 434, SUITE 100 LONGWOOD, FL 32779 <br />TEL 407/682-2086 ■ FAX 407/682-2386 <br />WWW.SCD-ENG.COM <br />������oluro9UaV° <br />-A- <br />t. <br />A� <br />Ico4,��1C� <br />°0�°o�ooauoe°�' <br />Robert C. Scroggins, P.E. <br />FL Registration No. 56158 <br />This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date <br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not <br />considered signed and sealed and the signature must be verified on any electronic copies, <br />SET DISTRIBUTIONS: <br />12/16/2021 OWNER REVIEW SET <br />02/17/2022 PERMIT SET <br />x / SHEET REVISIONS: <br />i <br />e0 <br />W <br />x <br />-- - - <br />U <br />W <br />_ <br />0 <br />0 <br />z <br />W <br />F- <br />z <br />O <br />W <br />_ <br />i- <br />SC&D PROJECT NO. 21-020 <br />o FORUM PROJECT NO. 4097 <br />W <br />W <br />U <br />z <br />W <br />Building Type I - <br />0 <br />Second Floor <br />Of <br />Framing Plan <br />W <br />Z <br />05 <br />W <br />H <br />U <br />W <br />F- <br />s <br />U <br />S3.12 <br />a <br />n, <br />0 <br />J. <br />O <br />