Laserfiche WebLink
use <br />N <br />N <br />O <br />N <br />1.f1 <br />N <br />fO <br />Typical Sheet Notes <br />Roof Framing Plan <br />A. SEE SHEET "S3.01" FOR GENERAL STRUCTURAL NOTES, TYP. <br />B. SEE SHEET "S4.00.1" FOR WOOD BEAM/HEADER SCHEDULE, TRUSS FRAMING DESIGN <br />CRITERIA, & TYPICAL BUILT-UP WOOD STUD COLUMN DETAILS, TYP. <br />C. SEE SHEET "S4.04.1" FOR FLORIDA BUILDING CODE COMPONENT & CLADDING DESIGN <br />WIND PRESSURE TABLE, TYP. <br />D. GIRDER TRUSS ACROSS CORRIDOR TO BE DESIGNED TO ALLOW MECHANICAL DUCT <br />TO PASS THROUGH. COORDINATE w/ M.E.P. DRAWINGS, TYP. <br />E. ALL MASONRY WALLS TO BE 8" CMU (f m = 1,500 PSI) w/ 9 GA. HOR1Z. LADDER REINF. <br />@ 16" O.C. & HAVE #5 VERTICAL BAR @ 32" O.C. IN SOLID GROUTED CELL, TYP. <br />PROVIDE 48 BAR 0 LAP w/ VERTICAL REINF. ABOVE BOND BEAM WHERE REQ'D., TYP. <br />SEE SHEET "S3.05" FOR TYPICAL MASONRY DETAIL <br />I l Building Type i -Roof Framing Plan <br />S3.15) SCALE: Ys' = 1'-0" <br />Key Notes <br />Roof Framing Plan (4 Story Building) <br />I. ROOF TRUSS BEARING ELEVATION = 45'-6Y4", TYP. (U.N.O.) 9. ROOF SHEATHING NAILING SCHEDULE: <br />• NAIL @ 6" O.C. AT DIAPHRAGM BOUNDARIES, OVER PERIMETER WALLS, AND AT <br />2. TRUSS SHOP DRAWINGS: PROVIDE SHOP DRAWINGS SHOWING TRUSS LAYOUT, ALL RIDGES, HIPS, & VALLEYS. <br />PROFILES, CONNECTIONS, & LOAD DIAGRAMS FOR FLOOR TRUSS SYSTEM SIGNED & . NAIL @ 12" O.C. ALL INTERIOR SUPPORTS AND ALL OTHER PANEL EDGES. <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. • UNBLOCKED DIAPHRAGM, USE 8d RING SHANK OR 10d COMMON NAILS w/ 1%" <br />MINIMUM PENETRATION, TYP. <br />3, COORDINATE ALL CHASE & CONDUIT LOCATIONS w/ M.E.P. IN RELATION TO <br />STRUCTURAL ELEMENTS, TYP. <br />4. ALL STUD WALL SILL PLATES & OTHER WOOD MEMBERS IN CONTACT w/ CONCRETE <br />OR MASONRY SHALL BE PRESSURE TREATED, TYP. <br />5. SHEARWALLS & TRUSSES: WHEN SHEARWALLS ARE PARALLEL w/ ROOF OR FLOOR <br />TRUSSES & NORMALLY SPACED TRUSSES DO NOT ALIGN w/ SHEARWALLS, PROVIDE <br />FULL HEIGHT INFILL TRUSSES OVER EACH SHEARWALL w/ VERTICAL MEMBERS @ 16" <br />O.C. MAX. ANCHOR TRUSSES TO SHEARWALLS & DECK SHEATHING AS NOTED ON <br />SHEARWALL SCHEDULES. ADJUST HEIGHT & SHAPE OF TRUSSES AS REQ'D. TO MATCH <br />DEFLECTION OF SPANNING TRUSSES. <br />6. ROOF TRUSSES: PROVIDE ENGINEERED, PRE -FABRICATED 2x WOOD TRUSSES FOR <br />LOADS, SPANS, & CONDITIONS SHOWN. SPACE TRUSSES @ 24" O.C. MAX. & AS <br />REQUIRED BY TRUSS MANUF. PROVIDE ALL REQUIRED INFILL FRAMING, BLOCKING, & <br />BRACING AS REQ'D. TO FRAME ENTIRE ROOF ASSEMBLY. PROVIDE ALL NECESSARY <br />SUPPORT CONDITIONS FOR FRAMING ATTACHED TO WOOD TRUSSES. SECURE <br />BEARING POINTS OF EACH TRUSS w/ GALVANIZED HURRICANE STRAPS AS SPECIFIED <br />& DETAILED. <br />7. ROOF TRUSS DRAFTSTOP: PROVIDE DRAFTSTOPPING AS SPECIFIED ON ARCH. DWGS <br />IN ROOF TRUSS ABOVE TENANT SEPARATION WALLS, BREEZEWAY WALLS & <br />CORRIDOR WALLS TYP. <br />8. ROOF SHEATHING: PROVIDE Y2" EXTERIOR GRADE, SPAN RATED, CODE CERTIFIED <br />PLYWOOD (or 1%2" EXTERIOR GRADE, SPAN RATED, CODE CERTIFIED O.S.B. <br />SHEATHING) w/ H-CLIPS AS REQ'D., TYP. <br />10. TYPICAL TRUSS TO HAVE SIMPSON "H10A" @ EACH BEARING POINT, TYP. <br />11. TYPICAL 2-PLY GIRDER TRUSS TO HAVE SIMPSON "LGT2" & "MTS12" @ EACH BEARING <br />POINT, & TYPICAL 3-PLY GIRDER TRUSS TO HAVE SIMPSON "LGT3-SDS2.5" @ EACH <br />BEARING POINT, TYP. (U.N.O.) <br />12. TRUSS MANUF. NOTE: ALL TRUSS OVERFRAMING MEMBERS & ALL TRUSS TO TRUSS <br />CONNECTIONS TO BE DESIGNED & DETAILED BY TRUSS ENGINEER. COORD. TRUSS <br />PROFILES w/ ARCH. DWGS., TYP. <br />13. GIRDER TRUSS SUPPORT: PROVIDE (4) 2x MULTI -STUD WOOD POST FASTENED w/ 10d <br />NAILS @ 12" O.C. STAGGERED EACH PLY UNDER BEARING POINTS OF ALL <br />PRE-ENGINEERED GIRDER TRUSSES TO FOUNDATION w/ CRUSH BLOCKS IN FLOOR <br />TRUSSES, TYP. (U.NO.) <br />14. TRUSS ENGINEER TO PROVIDE DRAG TRUSS OVER SHEAR WALLS PARALLEL TO TRUSS <br />FRAMING w/ AXIAL CAPACITY TO RESIST BASE SHEAR LOAD NOTED IN SHEAR WALL <br />SCHEDULE, TYP. <br />15. ELEVATOR HOIST BEAM AT TOP OF CMU ELEVATOR SHAFT HEIGHT & LOCATION TO <br />BE COORD. w/ ARCH. DWGS. & ELEVATOR MANUF., TYP. <br />16. HATCH INDICATES FLAT ROOF AREA FOR MECH. CONDENSING UNITS. COORD. <br />TRUSS PROFILES & LAYOUT w/ ARCH, DWGS. & PROVIDE Y4" SHEATHING @ FLAT <br />ROOF AREAS, TYP. <br />17. ROOF TRUSS BRG. ELEV. = +42'-63/4" @ UNIT "Al" SOLARIUM, UNIT "B1" SOLARIUM, & <br />UNIT "Cl" SOLARIUM & LIVING ROOM. COORS. w/ ARCH. DWGS., TYP. <br />ro <br />4J <br />ro <br />_0 <br />E <br />v <br />JC <br />4-0 <br />,3 <br />v <br />U <br />C <br />ro <br />L <br />0 <br />U <br />U <br />ro <br />0 <br />r <br />C <br />ro <br />ro <br />U <br />0 <br />v <br />r <br />+j <br />Ja <br />v <br />C <br />E <br />L <br />v <br />iA <br />ro <br />1A <br />10 <br />0 <br />U <br />Ja <br />E <br />E <br />C <br />,E <br />y <br />ro <br />U <br />a <br />v <br />.0 <br />3 <br />a <br />E <br />0 <br />U <br />+. <br />U <br />v <br />0 <br />L <br />a <br />4 <br />s <br />4J <br />L <br />0 <br />V) <br />C <br />0 <br />'4-j <br />0 <br />U <br />U <br />v <br />a <br />+ttoy <br />V <br />C <br />ro <br />to <br />ro'� <br />a <br />v <br />z <br />4-1 <br />by <br />W <br />W <br />3 <br />0 <br />C <br />v <br />v <br />C <br />b0 <br />C <br />W <br />C <br />0 <br />v <br />r <br />4-1 <br />4. <br />0 <br />H <br />^v^ <br />.�J <br />0 <br />I� <br />mFORUME <br />Lu <br />m <br />0 <br />ARCHITECTURE & <br />I N <br />z INTERIOR DESIGN, INC. <br />i PLANNING I ARCHITECTURE I INTERIOR DESK3N <br />ui <br />W <br />0 <br />a <br />F 237 S. Westmonte Drive, Suite 220 <br />z Altamonte Springs, FL 32714 <br />05 407.830.1400 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />City of Zephyrhills, FL <br />ClUr�4AL.. <br />i <br />I e <br />2965 WEST STATE ROAD 434, SUITE 100 LONGWOOD, FL 32779 <br />TEL 407/682-2086 ■ FAX 407/682-2386 <br />WWW.SCD-ENG.COM <br />61 <br />ttf <br />n151 <br />`.;.. <br />58 <br />OZ22 r� , <br />»a.0 o�,:� t� <br />n ,� =j)N <br />Robert C. Scroggins, P.E. <br />FL Registration No. 56158 <br />This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date <br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not <br />considered signed and sealed and the signature must be verified on any electronic copies. <br />SET DISTRIBUTIONS: <br />12/16/2021 OWNER REVIEW SET <br />02/17/2022 PERMIT SET <br />A SHEET REVISIONS: <br />EDITED BY: RCS, TLW <br />SC&D PROJECT NO, 21-020 <br />FORUM PROJECT NO. 4097 <br />2 <br />N Building Type I - <br />W <br />0 <br />x <br />Roof Framing Plan <br />W <br />I— <br />Z <br />co <br />W <br />tr <br />1_ <br />U <br />W <br />H <br />I <br />U <br />I <br />S3.15 <br />O <br />W <br />