N CONCRETE MASONRY UNIT WALL ASSEMBLIES <br />TYPICAL AT EXTERIOR WALLS AT UNCONDITIONED / UNFINISHED SPACE <br />EXTERIOR FINISH PER ELEVATIONS: <br />__ A. FIBER CEMENT LAP SIDING, PANEL &TRIM WITH <br />- r <br />WATER -RESISTIVE BARRIER (BUILDING WRAP) OVER <br />2 HOUR RATED <br />i <br />i <br />i <br />/ <br />%° h:_ <br />PT 1x WOOD FURRING @ 24" OC MAX <br />PER <br />FBC TABLE 721.1(2) <br />MATERIAL 3 <br />i <br />2 H.R. <br />_..__ <br />— CMU WALL (CLASS D-2) PER STRUCTURAL DRAWINGS, 8" (MIN) <br />(WEB THICKNESS <br />_- <br />UNO <br />FOR RATING PER <br />i <br />_ - <br />CALCULATIONS ON <br />i <br />-- PAINT FINISH AT EXPOSED SURFACES <br />x~� <br />THIS SHEET) <br />EXT i <br />INT <br />TYPICAL AT INTERIOR WALLS <br />17, <br />2 HOUR RATED <br />M <br />PER <br />\ <br />FBC TABLE 721.1(2) <br />PAINT FINISH AT EXPOSED SURFACE AT UNFINISHED SPACE <br />MATERIAL 3 <br />e,= <br />— CMU WALL (CLASS D-2) PER STRUCTURAL DRAWINGS, 8" (MIN) <br />-f -- UNO <br />(WEB THICKNESS <br />_ _ PT 2x WOOD FURRING @ 24" OC MAX <br />FOR RATING PER <br />-- <br />CALCULATIONS ON <br />x X, <br />(1) LAYER 1/2" GYPSUM BOARD <br />THIS SHEET) <br />STC 50-52 <br />INT INT <br />LI�> <br />INT <br />PER NCMA TEK <br />— <br />13-1 C <br />STEEL WALL ASSEMBLIES I <br />5.14 <br />2 HOUR RATED <br />UNDERWRITER'S <br />LABORATORY <br />(UL) DESIGN <br />U415-B <br />2 HOUR RATED <br />UNDERWRITER'S <br />LABORATORY <br />(UL) DESIGN <br />U408 <br />N <br />u <br />U <br />U) <br />TYPICAL AT SHAFT WALLS <br />TYPICAL AT NON -BEARING INTERIOR WALLS <br />(1) LAYER 1" GYPSUM LINER PANEL <br />STEEL C-H STUDS AT 24" OC MAX WITH CONTINUOUS TRACK AT <br />TOP AND BOTTOM <br />(2) LAYERS 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE) <br />(1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE) <br />25 GA 3 5/8" LIGHT -GAUGE METAL FRAMING AT 24" OC MAX <br />(NOT SHOWN) UNFACED BATT INSULATION BETWEEN <br />CONDITIONED AND NON -CONDITIONED SPACES <br />(3) LAYERS 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE) <br />WOOD FRAMED WALL ASSEMBLIES (CONT) <br />TYPICAL AT INTERIOR <br />TENANT <br />SEPARATION <br />_ _--- - (1) LAYER 5/8 FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />- <br />_ <br />f Jam- GRADE AT NON -CONDITIONED SPACE) <br />1 HOUR RATED <br />- <br />CALCULATED <br />PER <br />= <br />1 - -- DOUBLE ROW OF WOOD STUDS AT 16" OC MAX (STAGGERED) <br />--_ _ PER STRUCTURAL DRAWINGS <br />_= <br />_ <br />FBC-B 722.6.2(1) & <br />FBC-B 722.6.2(2) <br />- <br />__ - <br />` — 1"AIR SPACE <br />-_ <br />- <br />_ <br />-= --- _ " <br />- <br />— F INSULATION N T " <br />UNFACED BATT IN 0 0 BOTH SIDES (3 MIN) <br />(REFER TO <br />= __- <br />_---_= <br />---`-- COMPRESSED UNPAGED GATT INSULATION FIREBLOCKING <br />CALCULATIONS <br />_ BETWEEN STUD ROWS AT 10' MAX HORIZONTALLY <br />ON THIS SHEET) <br />GARAGE <br />.. _� <br />UNIT OR <br />- _ <br />- <br />GARAGE,-- (1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD <br />UNIT DR <br />STC 56 <br />PER TL-93-266 <br />OTHER INT <br />FIRE SIDE <br />_- <br />s. <br />OTHERINT <br />FIRE SIDE <br />TYPICAL AT NON -BEARING <br />FIRE -RATED ATTIC SEPARATION <br />— (1) LAYER 5/8" FIRE -RATED TYPE X EXTERIOR GRADE GYPSUM <br />-__._--_-- <br />BOARD <br />1 HOUR RATED <br />-- - WOOD STUDS OR VERTICAL TRUSS MEMBERS AT 16" OC MAX <br />PER STRUCTURAL DRAWINGS <br />- �-- (1) LAYER 5/8" FIRE -RATED TYPE X EXTERIOR GRADE GYPSUM <br />UNDERWRITER'S <br />BOARD <br />LABORATORY <br />(UL) DESIGN <br />U338 <br />ATTIC <br />ATTIC <br />(FIRE SIDE) <br />FIRE SIDE <br />TYPICAL AT INTERIOR NON -BEARING NON -RATED WALL <br />(1) LAYER 112" GYPSUM BOARD (EXT GRADE AT NOW <br />�__--- <br />CONDITIONED SPACE). OMIT IF WITHIN CAVITY (SUCH AS <br />NON -RATED CHASE / PILASTER) <br />NON -RATED <br />WOOD STUDS AT 24" OC MAX <br />_ - - — (NOT SHOWN) UNFACED BATT INSULATION BETWEEN <br />CONDITIONED AND NON -CONDITIONED SPACES <br />(1) LAYER 112" GYPSUM BOARD (EXT GRADE AT NON- <br />_ - CONDITIONED SPACE) <br />NOTE: AT OPEN CAVITY/CHASE CONDITIONS, PROVIDE <br />CONTINUOUS FIREBLOCKING AT EACH FLOOR AND AT 10' MAX <br />INT OR <br />HORIZONTALLY <br />CAVITY <br />INT <br />TYPICAL AT INTERIOR BEARING NON -RATED WALL <br />- - <br />(1) LAYER 112" GYPSUM BOARD (EXT GRADE AT NON- <br />�- CONDITIONED SPACE). OMIT IF WITHIN CAVITY (SUCH AS <br />~-� - NON -RATED CHASE / PILASTER) <br />� NON -RATED <br />-- <br />_ — WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />(NOT SHOWN) UNFACED BATT INSULATION BETWEEN <br />_ CONDITIONED AND NON -CONDITIONED SPACES <br />_ - (1) LAYER 1l2" GYPSUM BOARD (EXT GRADE AT NOW <br />CONDITIONED SPACE) <br />NOTE: AT OPEN CAVITY/CHASE CONDITIONS, PROVIDE <br />CONTINUOUS FIREBLOCKING AT EACH FLOOR AND AT 10' MAX <br />INT OR <br />HORIZONTALLY <br />CAVITY <br />INT <br />0 WOOD FRAMED WALL ASSEMBLIES (CONT) <br />TYPICAL AT EXTERIOR FIRE -RATED WALLS - FINISH BOTH SIDES <br />NNV 5 <br />EXTERIOR FINISH PER ELEVATIONS OVER WATER -RESISTIVE <br />BRZWY OR='A BARRIER (BUILDING WRAP): <br />PATIO/BALCONY y--' A. FIBER CEMENT LAP SIDING, PANEL & TRIM <br />(FIRE SIDE) / <br />1 HOUR RATED <br />CALCULATED <br />PER <br />BRZWY OR <br />FBC-B 722.6.2(1) & <br />i PATIO/BALCONY <br />FBC-B 722.6.2(2) <br />(FIRE SIDE <br />PROVIDE CONTINUOUS CAVITY FIREBLOCKING PER FLOOR <br />(REFER TO <br />i ---� <br />-: -�---- — (1) LAYER 5/8" FIRE -RATED TYPE X EXTERIOR GRADE OR <br />CALCULATIONS <br />-_ T-- - GLASS MAT FACED GYPSUM BOARD <br />- <br />ON THIS SHEET) <br />--__--__-_- � ------- _ <br />�� — WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />---��� <br />EXT _-- <br />- (1) LAYER 1/2" MIN (NOMINAL) WOOD STRUCTURAL PANEL <br />EXTERIOR SHEATHING PER STRUCTURAL DRAWINGS <br />TYPICAL AT EXTERIOR RATED WALLS - FINISH BOTH SIDES <br /><e> <br />_.. <br />i <br />- EXTERIOR FINISH PER ELEVATIONS OVER WATER -RESISTIVE <br />` f <br />BARRIER (BUILDING WRAP): <br />A. FIBER CEMENT LAP SIDING, PANEL & TRIM <br />1 HOUR RATED <br />f' <br />CALCULATED <br />PER <br />FBC-B 722.6.2(1) & <br />FBC-B 722.6.2(2) <br />- (1) LAYER 5/8" FIRE -RATED TYPE X EXTERIOR GRADE OR <br />(REFER TO <br />I <br />i GLASS MAT FACED GYPSUM BOARD <br />CALCULATIONS <br />ON THIS SHEET) <br />WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />EXT i <br />-------------------------- <br />i EXT <br />TYPICAL AT INTERIOR BEARING OR OTHER FIRE -RATED WALL <br />4� <br />- <br />- (1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE) <br />1 HOUR RATED <br />�-' `! _ - - `- WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />— (NOT SHOWN) UNFACED BATT INSULATION BETWEEN <br />CONDITIONED AND NON -CONDITIONED SPACES <br />CALCULATED <br />- _ <br />PER <br />(1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />FBC-B 722.6.2(1) & <br />_ = " GRADE AT NON -CONDITIONED SPACE) <br />FBC-B 722.6.2(2) <br />--' <br />(REFER TO <br />CALCULATIONS <br />ON THIS SHEET) <br />INT <br />INT <br />(.FIRE SIDE) <br />F( IRE SIDE) <br />TYPICAL AT INTERIOR <br />NON <br />-BEARING WALL INTERRUPTING RATED CEILING PER FBC 714.4.2 <br />-- - - (1) LAYER 1/2" MIN TYPE X GYPSUM BOARD (EXT GRADE AT <br />- <br />NON -CONDITIONED SPACE). OMIT IF WITHIN CAVITY (SUCH AS <br />- NON -RATED CHASE / PILASTER) <br />NON -RATED <br />_ - WOOD STUDS AT 24" OC MAX WITH DOUBLE TOP PLATE <br />f (NOT SHOWN) UNFACED BATT INSULATION BETWEEN <br />J <br />- CONDITIONED AND NON -CONDITIONED SPACES <br />(1) LAYER 1/2" MIN TYPE X GYPSUM BOARD (EXT GRADE AT <br />�~ NON -CONDITIONED SPACE) <br />NOTE: AT OPEN CAVITY/CHASE CONDITIONS, PROVIDE <br />CONTINUOUS FIREBLOCKING AT EACH FLOOR AND AT 10' MAX <br />INT OR <br />HORIZONTALLY <br />CAVITY <br />INT <br />TYPICAL AT CORRIDOR TO UNIT <br />(1) LAYER 5/8"FIRE-RATED TYPE X GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE <br />1 HOUR RATED <br />---- <br />-- — RESILIENT CHANNELS INSTALLED HORIZONTALLY AT 24" OC <br />_~-- <br />-- MAX <br />- - <br />_ - — WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />UNDERWRITER'S <br />LABORATORY <br />i - _ <br />-- - -- R-19 UNFACED BATT INSULATION (COMPRESS INTO 2X4 <br />_: <br />_ ----_. <br />(UL) DESIGN <br />-r - CAVITIES AS APPLICABLE) <br />U305 <br />�' - <br />_-= <br />_ _ - (1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD <br />STC 51------ <br />----- <br />PER NGC 2011071 <br />-- <br />CORRIDOR <br />UNIT <br />_ _.:_ <br />(FIRE SIDES <br />TYPICAL AT INTERIOR BEARING WALLS - FINISH ONE SIDE <br />WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />-----__ <br />/ - BATT INSULATION AT CONDITIONED SPACES <br />1 HOUR RATED <br />-_ _ <br />! '— (1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD (EXT <br />GRADE AT NON -CONDITIONED SPACE) <br />CALCULATED <br />PER <br />�J <br />FBC-B 722.6.2(1) & <br />FBC-B 722.6.2(2) <br />-'- -or <br />- <br />(REFER TO <br />CALCULATIONS <br />ON THIS SHEET) <br />_ -__ <br />NOTE: AT OPEN CAVITY/CHASE CONDITIONS, PROVIDE <br />CONTINUOUS FIREBLOCKING AT EACH FLOOR AND AT 10' MAX <br />_- <br />INT HORIZONTALLY <br />CAVITY <br />-- - <br />LRE SIDE) <br />CONSTRUCTION ASSEMBLY NOTES <br />A ASSEMBLIES MAY NOT BE NUMBERED IN SEQUENTIAL ORDER. <br />B THE INDICATED UL ASSEMBLIES AND OTHER SPECIFIED FIRE RATED DESIGNS ARE THE "BASIS OF DESIGN" FOR FIRE SAFETY, SOUND <br />TRANSMISSION, MATERIAL SELECTION, ETC. THE COMPONENTS OF THE RATED ASSEMBLY SHALL BE PER THE SPECIFIED FIRE TEST AND/OR <br />SOUND TEST. THE CONTRACTOR MAY SUBMIT ALTERNATE ASSEMBLIES FOR REVIEW AND APPROVAL BY THE ARCHITECT, PRIOR TO <br />CONSTRUCTION, TO BE USED IN PLACE OF THE ASSEMBLIES INDICATED ON THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL <br />PROVIDE ALL MATERIALS AND EQUIPMENT AS INDICATED IN THE ASSEMBLY AND/OR WITHIN THE SYSTEM THAT IS PART OF THE ASSEMBLY, <br />SUBSTITUTION OF MATERIALS OR ADDITIONAL MATERIALS WHICH ARE NOT ALLOWED PER THE ASSEMBLY WILL NOT BE ACCEPTED. APPROVAL <br />OF THE ASSEMBLY BY THE ARCHITECT DOES NOT RELEASE THE CONTRACTOR FROM THE RESPONSIBILITY OF MEETING ALL APPLICABLE CODES <br />AND REGULATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR SUBMITTING DOCUMENTATION OF ANY PROPOSED ALTERNATE ASSEMBLIES <br />TO THE AHJ FOR APPROVAL PRIOR TO CONSTRUCTION. <br />C CONTRACTOR TO PROVIDE CURRENT UL LISTED PENETRATION FIRESTOP SYSTEM DESIGNS AND INSTALLATIONS COMPATIBLE FOR THE FIRE <br />RATED ASSEMBLIES BEING PENETRATED. SUBMIT COPIES OF UL LISTED PENETRATION SYSTEMS TO ARCHITECT FOR REVIEW AND APPROVAL, <br />PRIOR TO CONSTRUCTION. CONTRACTOR IS ALSO RESPONSIBLE FOR SUBMITTING DOCUMENTATION OF PROPOSED PENETRATION FIRESTOP <br />SYSTEM TO THE AHJ FOR APPROVAL PRIOR TO CONSTRUCTION, <br />D THE ANNULAR SPACE OF PENETRATIONS OF METAL PIPING OR TUBING WITH A MAX 6" DIA. THROUGH HORIZONTAL ASSEMBLIES SHALL BE <br />PROTECTED PER CODE OR BY AN APPROVED FIRESTOP SYSTEM. <br />E FIRESTOP SYSTEM PENETRATIONS THROUGH WALLS SHALL HAVE'F RATINGS MATCHING THE WALL BEING PENETRATED. <br />F FIRESTOP SYSTEM PENETRATIONS THROUGH HORIZONTAL ASSEMBLIES SHALL HAVE'F' &'T' RATINGS MATCHING THE FLOOR BEING <br />PENETRATED, EXCEPT THAT T-RATINGS ARE NOT REQUIRED WHERE THE PENETRATIONS OCCUR WITHIN THE CAVITIES OF WALLS PER CODE. <br />G COPIES OF ALL REFERENCED FIRE -RATED DESIGNS HAVE BEEN INCLUDED IN THE PROJECT MANUAL SPECIFICATIONS. <br />H FOR NEW BUILDINGS THREE STORIES OR GREATER IN HEIGHT, THE FOLLOWING QUALITY ASSURANCE PROGRAM FOR FIRE -STOP SYSTEMS, <br />PENETRATIONS AND JOINTS SHALL BE PROVIDED BY THE OWNER: INSPECTIONS OF INSTALLED FIRE -STOP SYSTEMS SHALL BE PERFORMED BY <br />A THIRD PARTY INSPECTOR IN ACCORDANCE WITH NFPA-1-2012 FIRE CODE SECTION 12.3.2, PER ASTM E 2174 AND E 2393 AS APPLICABLE, IN <br />ACCORDANCE WITH AHJ REQUIREMENTS. THE THIRD PARTY INSPECTOR WILL BE CONTRACTED BY THE OWNER, REFER ALSO TO <br />SPECIFICATIONS DIVISION 07, PENETRATION FIRESTOPPING. <br />I RESILIENT CHANNEL (RC) INSTALLATION: FOR ALL WALLS SCHEDULED WITH RC, INSTALL HORIZONTALLY AT 24" OC MAX, 4"-6" FROM CEILING <br />AND 2" FROM BOTTOM, AND AS REQUIRED TO SUPPORT CABINETS, ALWAYS WITH OPEN LEG POINTING UP. NEST/OVERLAP CHANNEL ENDS 4". <br />FOR ALL CEILINGS SCHEDULED WITH RC, INSTALL PER TESTED ASSEMBLY REFERENCED, PROVIDE A 1/4"-1/2" GAP BETWEEN THE ENDS OF ALL <br />RC AND ADJACENT CONSTRUCTION. SCREWS USED TO ATTACH GYP BD TO RC SHALL NOT DIRECTLY CONTACT FRAMING/STRUCTURE, <br />J ACOUSTICAL SEALANT: APPLY CONTINUOUS BEAD OF ACOUSTICAL SEALANT (1/4"-112") APPROVED FOR USE IN FIRE -RATED ASSEMBLIES AS <br />NOTED BELOW AS A CRITICAL COMPONENT OF ACHIEVING A MINIMUM SOUND RATING OF STC & IIC 50 PER FBC/IBC CHAPTER 12: <br />• WITHIN ALL DWELLING UNITS ABOVE THE GROUND FLOOR, APPLY ACOUSTICAL SEALANT AT THE BOTTOM OF GYP BD SHEATHING INSTALLED <br />ON INTERIOR WALLS, TENANT WALLS, AND WALLS SEPARATING UNITS FROM COMMON AREAS, CORRIDORS AND/OR BREEZEWAYS. <br />• WITHIN ALL DWELLING UNITS, APPLY ACOUSTICAL SEALANT AROUND THE PERIMETER OF ALL MEMBRANE PENETRATIONS OF GYP BD WALL <br />AND CEILING SHEATHING INSTALLED ON TENANT WALLS, WALLS SEPARATING UNITS FROM COMMON AREAS, CORRIDORS AND/OR <br />BREEZEWAYS, AND AT FLOOR -CEILING ASSEMBLIES. SUCH MEMBRANE PENETRANTS INCLUDE ELECTRICAL BOXES (FOR SWITCHES, <br />OUTLETS, LIGHT FIXTURES AND CEILING FANS), MECHANICAL DUCTWORK / BOXES, SPRINKLER HEADS, ETC. <br />K REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO LUMBER SIZE/GRADE/SPACING, <br />ATTACHMENT, ADDITIONAL ENGINEERED WOOD SHEATHING REQUIRED TO DEVELOP SHEAR, SCHEDULES FOR <br />COLUMNS/POST/HEADERS/LINTELS AND OTHER REQUIREMENTS, <br />RATED ASSEMBLY CALCULATIONS (AS REFERENCED <br />WOOD WALLS (FROM FIRE SIDE) PER FBC 722.6: FIRE RATING AT CMU WALLS PER FBC 722.3.2: <br />RATING RATING <br />MATERIAL (MINUTES) AGGREGATE & MIN EQUIV THICKNESS (HOURS) <br />WOOD STUDS AT 16" OC MAX 20 LIMESTONE AT 2.7" OR SILICEOUS AT 2.8" 1 <br />(1) LAYER 5/8" FIRE -RATED 40 LIMESTONE AT 4.0" OR SILICEOUS AT 42' 2 <br />TYPE X GYP BD <br />TOTAL TIME 60 <br />AT CIP CONCRETE PER FBC 722.2: AT CIP COLUMNS PER FBC 722.2.4: <br />MIN THICKNESS <br />SLABMALL <br />(WORST -CASE <br />RATING <br />MIN <br />AGGREGATE) <br />(HOURS) <br />DIMENSION <br />3.5" <br />1 <br />8" <br />5.0" <br />2 <br />10- (OR 8" X 36" MIN) <br />6,25" <br />3 <br />12" (OR 8" X 36" MIN) <br />7.0" <br />4 <br />14" (OR 10" X 36" MIN) <br />ASSEMBLY TAG <br />ASSEMBLY TYPE _ <br />W = <br />WALL <br />F = <br />FLOOR <br />R = <br />ROOF <br />-- <br />ASSEMBLY MATERIAL <br />W..... = <br />WOOD _... <br />C = <br />CONCRETE <br /># <br />S - <br />STEEL <br />ASSEMBLY NUMBER <br />RATING <br />(HOURS) <br />0 WOOD FRAMED WALL ASSEMBLIES <br />1 <br />2 <br />3 <br />d <br />CMU COLUMNS PER 722.3.5 <br />TYPICAL <br />DIMENSION <br />RATING <br />(MIN SIDE) <br />(HOURS) <br />8" <br />1 <br />10" <br />2 <br />12" <br />3 <br />16"+ <br />4 <br />0 INSULATION <br />DESIGN INSULATION MIN VALUES <br />FOR ASSEMBLIES SCHEDULED <br />WITH INSULATION, TYPICAL/UNO: <br />R-11 MIN AT TENANT SEPARATION <br />R-13 AT 2x4 STUD FRAMING <br />R-19 AT 2x6 STUD FRAMING <br />R-30 AT ATTIC <br />TYPICAL AT EXTERIOR BEARING WALLS <br />.1 <br />-- - <br />_ <br />_ - EXTERIOR FINISH PER ELEVATIONS OVER WATER -RESISTIVE <br />__ <br />.-' - <br />BARRIER (BUILDING WRAP): <br />--- - <br />A. FIBER CEMENT LAP SIDING, PANEL & TRIM <br />1 HOUR RATED <br />__ <br />B. MANUFACTURED STONE VENEER WITH GROUTED <br />JOINTS OVER 1/2" MIN CEMENT PLASTER SCRATCH <br />--- <br />COAT ON METAL LATH WITH PAPER BACKING <br />CALCULATED <br />_ - <br />PER <br />FBC-B 722.6.2(1) & <br />FBC-B 722.6.2(2) <br />(REFER TO <br />- (1) LAYER 1/2" MIN (NOMINAL) WOOD STRUCTURAL PANEL <br />CALCULATIONS <br />\_ EXTERIOR SHEATHING PER STRUCTURAL DRAWINGS <br />ON THIS SHEET) <br />i <br />;::_. <br />�� ` - °OC MAX PER STRUCTURAL DRAWINGS <br />WOOD STUDS AT 16 <br />UNFACED BATT INSULATION AT CONDITIONED SPACES <br />_ <br />INT <br />EXT <br />(FIRE SIDE) — (1) LAYER 5/8" FIRE -RATED TYPE X GYPSUM BOARD <br />TYPICAL AT EXTERIOR FIRE -RATED WALLS - FINISH BOTH SIDES <br />WW 3 <br />_— „ — EXTERIOR FINISH PER ELEVATIONS OVER WATER -RESISTIVE <br />BARRIER BUILDING WRAP): <br />A. FIBER CEMENT LAP SIDING, PANEL & TRIM <br />1 HOUR RATED <br />r B. MANUFACTURED STONE VENEER WITH GROUTED <br />�. <br />JOINTS OVER 1/2" MIN CEMENT PLASTER SCRATCH <br />i COAT ON METAL LATH WITH PAPER BACKING <br />CALCULATED <br />i <br />\� <br />PER <br />FBC-B 722.6.2(1) & <br />FBC-B 722.6.2(2) <br />�� <br />--- (1) LAYER 1/2" MIN (NOMINAL) WOOD STRUCTURAL PANEL <br />(REFER TO <br />EXTERIOR SHEATHING PER STRUCTURAL DRAWINGS <br />CALCULATIONS <br />� <br />i <br />� - <br />ON THIS SHEET) <br />i <br />i \_. WOOD STUDS AT 16" OC MAX PER STRUCTURAL DRAWINGS <br />BRZWY OR (1) LAYER 5/8" FIRE -RATED TYPE X EXTERIOR GRADE OR <br />BALCONY GLASS MAT FACED GYPSUM BOARD <br />EXT i <br />ARE SIDE) <br />3 <br />.0 <br />�FO UM 0 <br />a ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />c <br />237 S. Westmonte Drive, Suite 22 <br />i <br />6 Altamonte Springs, FL 3271� <br />407.830.140 <br />AR9719 <br />u <br />www.foru march itecture.cor <br />i <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />02/17/2022 <br />3 Karen V McIntyre <br />SET DISTRIBUTIONS: <br />_ ___-- <br />11124/21 100% DD Set <br />L 12/23/21 Owner Review Set <br />02117/22 Permit Set <br />Apartments - <br />Construction & <br />Referenced <br />Assemblies <br />Al .04 <br />