GENERAL DRAWING NOTES: <br />• DO NOT SCALE DRAWINGS, USE DIMENSIONS PROVIDED, TYPICALLY. IN THE CASE OF DIMENSIONAL CONFLICT, <br />ARCHITECTURAL DIMENSIONS GOVERN OVER STRUCTURAL DIMENSIONS, TYPICALLY. <br />• CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS w/ THE ARCHITECTURAL, MECHANICAL, <br />ELECTRICAL, PLUMBING, & CIVIL DOCUMENTS. SC&D SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCY OR <br />OMISSION. <br />• THE STRUCTURE IS STABLE ONLY IN IT'S COMPLETED FORM. TEMPORARY SUPPORTS REQUIRED FOR STABILITY <br />DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION SHALL BE DESIGNED, FURNISHED, & INSTALLED BY THE <br />CONTRACTOR, TYPICALLY. <br />• STRUCTURAL DRAWINGS ARE NOT TO BE REPRODUCED WITHOUT WRITTEN CONSENT FROM STRUCTURAL <br />CONCEPTS & DESIGN, LLC ANY REPRODUCTION OF THESE CONTRACT DOCUMENTS WITHOUT WRITTEN <br />CONSENT OF STRUCTURAL CONCEPTS & DESIGN, LLC. WILL BE REJECTED & NOT REVIEWED. <br />• SHOP DRAWINGS REVIEW SHALL REQUIRE TEN (10) BUSINESS DAYS FOR COMPLETION FROM TIME OF DELIVERY <br />TO STRUCTURAL CONCEPTS & DESIGN, LLC. SHOP DRAWINGS SHALL BE CHECKED & "APPROVED" BY GENERAL <br />CONTRACTOR PRIOR TO SUBMITTAL TO ARCHITECT OR THEY WILL BE RETURNED WITHOUT REVIEW, <br />• CONTRACTORS SUBMITTING SHOP DRAWINGS TO PROVIDE THREE (3) BLACKLINE COPIES FOR MARK-UP. <br />ADDITIONAL COPIES WILL BE RETURNED WITHOUT MARKS OR APPROVAL STAMP. <br />• SHOP DRAWINGS SUBMITTED TO SC&D AFTER INSTALLATION IN THE FIELD WILL NOT BE REVIEWED BY SC&D & <br />WILL BE KEPT ON FILE AS A RECORD COPY ONLY, <br />SUBMITTALS: <br />THE GENERAL CONTRACTOR SHALL PREPARE A DETAILED LIST & SCHEDULE OF ALL SUBMITTAL ITEMS TO BE SENT TO <br />THE STRUCTURAL ENGINEER PRIOR TO THE START OF CONSTRUCTION. THIS LIST SHALL BE UPDATED, REVISED, & <br />KEPT CURRENT AS THE JOB PROGRESSES. IF A SCHEDULE OF STRUCTURAL SUBMITTALS IS NOT PROVIDED TO SC&D, <br />SUBMITTAL REVIEW COULD TAKE LONGER THAN THE 10 BUSINESS DAYS SPECIFIED ABOVE. <br />THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE STRUCTURAL ENGINEER FOR REVIEW & <br />APPROVAL THE FOLLOWING ITEMS: <br />• CONCRETE MIX DESIGNS <br />• POST -TENSION CONCRETE FOUNDATIONS* <br />• REINFORCING STEEL: FOUNDATIONS, MASONRY, CONCRETE <br />• STEEL/WOOD STAIRS & HANDRAILS* <br />• ALUMINUM HANDRAILS* <br />• STRUCTURAL STEEL: SHOP & ERECTION DRAWINGS <br />• ENGINEERED WOOD FLOOR/ROOF TRUSS SYSTEMS* <br />• ALUMINUM CANOPIES/SUNSHADE SYSTEMS* <br />• CONTINUOUS ROD TIE -DOWN SYSTEM (C.R.T.S.)* <br />*SHOP DRAWINGSUBMITTALS N T <br />* <br />NOTED WITH AN ARE REQUIRED TO BE SIGNED &SEALED BY A REGISTERED <br />PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED. DELEGATED ENGINEERING <br />SUBMITTALS THAT ARE NOT SIGNED & SEALED WILL BE REJECTED WITHOUT REVIEW. <br />THE GENERAL CONTRACTOR SHALL SUBMIT DESIGN CALCULATIONS PREPARED AND SIGNED & SEALED BY A <br />PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED. DELEGATED ENGINEERING SUBMITTALS <br />THAT DO NOT INCLUDE SIGNED & SEALED CALCULATIONS WILL BE REJECTED WITHOUT REVIEW. STRUCTURAL <br />CALCULATIONS ARE REQUIRED FOR THE FOLLOWING ITEMS: <br />• POST -TENSION CONCRETE FOUNDATIONS* <br />• STEEL/WOOD STAIRS & HANDRAILS* <br />• ALUMINUM HANDRAILS* <br />• ENGINEERED WOOD FLOOR/ROOF TRUSS SYSTEMS* <br />- • ALUMINUM CANOPIES/SUNSHADE SYSTEMS* <br />• CONTINUOUS ROD TIE -DOWN SYSTEM (C.R.T.S.)* <br />DELEGATED ENGINEERING CALCULATION REQUIREMENTS. <br />• ALL SUBMITTED CALCULATIONS SHALL BE PRESENTED IN A LEGIBLE MANNER & FOLLOW AN ORDERLY, LOGICAL <br />SEQUENCE. <br />• ALL REFERENCES & SOURCES OF INFORMATION SHALL BE LISTED WITHIN THE CALCULATIONS. COPIES OF <br />PERTINENT SECTIONS SHALL BE INCLUDED. <br />• <br />BASIC LOADS & DERIVATION OF FORCES, MOMENTS, SHEARS, REACTIONS, DEFLECTIONS, CAMBERS, ETC. SHALL BE <br />INCLUDED IN THE CALCULATIONS. INCLUDE ALL UNBALANCED LOADING FORCES AS REQUIRED. LOAD <br />REQUIREMENTS w/ APPROPRIATE FACTORS SHALL BE AS REQUIRED BY THE LATEST EDITION OF THE REFERENCED <br />BUILDING CODE. <br />• DESIGN ASSUMPTIONS SHALL BE CLEARLY STATED. <br />• ALL COMPUTER GENERATED CALCULATIONS SHALL BE ACCOMPANIED w/ EXPLANATIONS OF INPUT/OUTPUT <br />DATA (i.e. VARIABLE IDENTIFICATION, LOAD DERIVATION, ETC.) & A BRIEF EXPLANATION OF GENERAL THEORY, <br />METHOD, & DESIGN ASSUMPTIONS USED SHALL BE INCLUDED. <br />• ALL CALCULATIONS SHALL BE SIGNED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE <br />THE PROJECT IS LOCATED. DELEGATED ENGINEERING SUBMITTALS THAT DO NOT INCLUDE COMPLETE SIGNED & <br />SEALED CALCULATIONS IN COMPLIANCE w/ REQUIREMENTS NOTED ABOVE WILL BE REJECTED WITHOUT REVIEW. <br />• DELEGATED ENGINEERING CALCULATION SUBMITTALS THAT DO NOT MEET THESE REQUIREMENTS WILL <br />BE REJECTED WITHOUT REVIEW. <br />DUE TO MULTIPLE ISSUES w/ DELEGATED ENGINEERS NOT PROVIDING THE REQUIRED SUBMITTAL DOCUMENTS <br />AND/OR CALCULATIONS ON RECENT PROJECTS, THE CONTRACTOR MUST PROVIDE THE NAME OF EACH PROPOSED <br />DELEGATED ENGINEER (FOR EACH DELEGATED ENGINEERING SCOPE OF WORK) TO SC&D FOR REVIEW & APPROVAL <br />PRIOR TO THE CONTRACTOR SUBMITTING ANY DELEGATED ENGINEERING DOCUMENTS TO THE DESIGN TEAM. ANY <br />DELEGATED ENGINEERING SUBMITTALS FROM NON -APPROVED DELEGATED ENGINEERS WILL BE REJECTED WITHOUT <br />REVIEW. <br />NOTE THAT ALL DELEGATED ENGINEERING SUBMITTALS MUST BE REVIEWED & APPROVED BY THE ARCHITECT & <br />ENGINEER OR RECORD PRIOR TO SUBMISSION TO THE BUILDING DIVISION, TYPICALLY. <br />00200 BUILDING CODES: <br />• FLORIDA BUILDING CODE 7th EDITION (2020) <br />• ASCE/SEI 7-16: MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES <br />00500 STRUCTURAL DESIGN CRITERIA: <br />Q THE STRUCTURE HAS BEEN DESIGNED IN ACCORD WITH METHOD 1 - ALLOWABLE STRESS DESIGN AS REQUIRED BY <br />Qi SECTION 2802.1 OF THE FLORIDA BUILDING CODE. REQUIREMENTS FOR TYPICAL STRUCTURAL LOADS ARE GIVEN <br />In BELOW UNLESS SPECIFIC AREAS OF THE DRAWING SPECIFICALLY CALL FOR DIFFERENT LOADING CRITERIA. <br />N <br />a <br />GRAVITY LOADING IS TO BE UNIFORM (U.N.O.) <br />LIVE LOADING PER FLORIDA BUILDING CODE: <br />• GENERAL AREAS: 80 PSF <br />5:1 • STAIRS & EXIT WAYS: 100 PSF <br />M • MECHANICAL ROOMS: 125 PSF <br />• SLAB -ON -GRADE AREAS: 150 PSF <br />C) • ROOFS - FLAT: 30 PSF (REDUCIBLE) <br />'¢ • ROOFS - SLOPED: 20 PSF (REDUCIBLE) <br />WIND LOADING PER FLORIDA BUILDING CODE <br />• ULTIMATE DESIGN WIND SPEED: VuLT = 139 MPH (3 SECOND GUST) <br />• NOMINAL DESIGN WIND SPEED: VASD = 108 MPH (3 SECOND GUST) <br />• RISK CATEGORY = "II" <br />• EXPOSURE CATEGORY = "C" <br />• INTERNAL PRESSURE COEFFICIENTS = +/- 0.18 (ENCLOSED) <br />• COMPONENT & CLADDING WIND PRESSURES SHOWN ON SHEET "S4.04.1" <br />* THIS PROJECT IS NOT LOCATED WITHIN A WIND BORNE DEBRIS REGION. <br />EARTHQUAKE DESIGN DATA PER FLORIDA BUILDING CODE & ASCE/SEI 7 <br />• SEISMIC IMPORTANCE FACTOR: (1) = 1.0 <br />• SPECTRAL RESPONSE ACCELERATIONS: Ss = 0.058g Si = 0.032g <br />• SITE CLASS = "D" <br />• SPECTRAL RESPONSE COEFFICIENTS: SIDS = 0.062g SDI = i ig <br />• SEISMIC DESIGN CATEGORY = "A" <br />• BASIC SEISMIC FORCE RESISTING SYSTEM: WOOD FRAMED SHEAR WALLS <br />• DESIGN BASE SHEAR = 4.75 KIPS <br />• RESPONSE MODIFICATION FACTOR (R) = 2 <br />• ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE <br />ESTIMATED DEFLECTIONS (IN INCHES) ARE AS FOLLOWS: <br />LIVE LOAD TOTAL LOAD <br />ROOF MEMBERS: L/360 or V L1240 <br />FLOOR MEMBERS: L/360 L1240 <br />WHERE "V = SPAN LENGTH (IN.) BETWEEN CENTERLINES OF SUPPORTS. <br />General Structural Notes <br />01100 SCOPE OF SERVICE: <br />STRUCTURAL CONCEPTS & DESIGN, LLC AS THE STRUCTURAL ENGINEER OF RECORD HAS DESIGNED AND IS <br />RESPONSIBLE FOR ONLY THE SPECIFIC STRUCTURAL COMPONENTS SHOWN IN THIS SET OF STRUCTURAL <br />CONSTRUCTION DOCUMENTS. IF A SPECIALTY ENGINEER, AS DEFINED BY THE DEPARTMENT OF PROFESSIONAL <br />REGULATION, IS REQUIRED, HIS SERVICES MUST COMPLY WITH THE SCOPE OF SERVICES AS OUTLINED IN THE <br />PROJECT CONSTRUCTION DOCUMENTS. <br />400 SCOPE OF SERVICE - THRESHOLD INSPECTOR: <br />THE THRESHOLD SPECIALTY INSPECTOR IS RESPONSIBLE FOR THE INSPECTION AND APPROVAL OF THE STRUCTURAL <br />COMPONENTS SHOWN IN THIS SET OF STRUCTURAL CONSTRUCTION DOCUMENTS AND AS INDICATED IN THE <br />THRESHOLD INSPECTION PLAN. THE THRESHOLD SPECIALTY INSPECTOR IS TO BE CONTRACTED BY THE OWNER AND <br />MUST BE A REGISTERED SPECIAL INSPECTOR IN THE STATE OF FLORIDA, IN COMPLIANCE WITH THE CURRENT EDITION <br />OF THE FLORIDA BUILDING CODE. <br />02000 FOUNDATIONS: <br />GEOTECHNICAL DATA AND RECOMMENDATIONS HAVE BEEN PROVIDED BY VERONICA DE FREITAS, P.E. & JAMES <br />STEPHENSON, P.E. (FL #86378) OF UNIVERSAL ENGINEERING SCIENCES, INC., 9802 PALM RIVER RD., TAMPA, FL 33619, <br />PHONE: (813) 704-8506, UES PROJECT No. 0830.2100171, UES REPORT No. 1927445 DATED JANUARY 17, 2022. BASED <br />ON THEIR RECOMMENDATIONS, THE FOLLOWING FOUNDATION SYSTEM WILL BE USED: <br />• SHALLOW STRIP & SPREAD FOOTINGS w/ MAXIMUM ALLOWABLE NET SOIL BEARING PRESSURE = 2,500 PSF <br />THE GEOTECHNICAL ENGINEER IS RESPONSIBLE FOR SPECIFYING AND MONITORING ALL TESTING, INSTALLATION, <br />EVALUATION, AND REPORTING RELATED TO THE FOUNDATION SYSTEM, INCLUDING ALL WORKMANSHIP <br />PROVISIONS RELATING TO THE SOIL - STRUCTURE INTERFACE. THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR <br />SPECIFYING THE MATERIALS USED TO CONSTRUCT THE FOUNDATION UNITS AND FOR THE SELECTION OF VARIOUS <br />SIZE UNITS TO SUPPORT THE STRUCTURAL FRAME. <br />D NOT PLACE AN S O N Y FOOTINGS OR MAT UNTIL RECEIPT OF WRITTEN THE GEOTECHNICAL <br />WR AUTHORIZATION O BY H <br />ENGINEER THAT THE PREPARED SUBGRADE OR DEEP FOUNDATION SYSTEM HAS BEEN PROPERLY EXECUTED IN <br />ACCORD WITH THE DESIGN AND THAT ANY VARYING CONDITIONS ENCOUNTERED DURING CONSTRUCTION HAVE <br />BEEN EVALUATED AND CORRECTED WHERE NECESSARY TO INSURE PROPER FOUNDATION PERFORMANCE. <br />02200 EARTHWORK: <br />CONTRACTOR SHALL DEWATER SITE AS NECESSARY, SO THAT ALL CONCRETE CAN BE PLACED IN THE DRY. ALL <br />BACKFILL SHALL BE ACCOMPLISHED USING MATERIAL CONSISTING OF CRUSHED STONE AND/OR MATERIAL <br />APPROVED BY THE GEOTECHNICAL ENGINEER. THE BACKFILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY <br />AS DETERMINED BY ASTM D-1557. NO BACKFILL MATERIAL SHALL BE PLACED AGAINST WALLS WHICH DO NOT HAVE <br />PERMANENT FLOORS AT THE TOP AND BOTTOM WITHOUT PROVISIONS FOR ADEQUATE TEMPORARY BRACING OF <br />THOSE WALLS. PROVIDE ADEQUATE EXCAVATION BRACING IN ACCORD WITH GEOTECHNICAL ENGINEER <br />RECOMMENDATIONS TO MAINTAIN EXISTING FOOTINGS, UTILITIES, AND OTHER IMPROVEMENTS IN A SAFE <br />CONDITION. <br />02210 STRUCTURAL FILL: <br />FOUNDATIONS PLACED ON COMPACTED STRUCTURAL FILL HAVE BEEN DESIGNED FOR A MAXIMUM ALLOWABLE NET <br />SOIL BEARING PRESSURE OF 2,500 PSF. FILL TO BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY <br />ASTM D-1557. PLACE FILL IN LAYERS OF 12" THICK MAXIMUM AND UNDER THE DIRECT SUPERVISION OF A <br />GEOTECHNICAL ENGINEER. FILL TO BE TESTED TO VERIFY COMPACTION. <br />02260 PROOF -ROLLING: <br />ISOLATED SPREAD COLUMN FOOTINGS SHALL NOT BE LESS THAN T-0" WIDE IN EITHER DIRECTION & SHOULD BE <br />BASED F-6" MIN. BELOW THE FINISHED FLOOR OR FINAL EXTERIOR GRADES AT 2,500 PSF MAX. ALLOWABLE NET SOIL <br />BEARING PRESSURE. CONTINUOUS STRIP WALL FOOTINGS SHALL NOT BE LESS THAN T-0" WIDE & SHOULD BE BASED <br />1'-6" MIN. BELOW THE FINISHED FLOOR OR FINAL EXTERIOR GRADES AT 2,500 PSF MAX. ALLOWABLE NET SOIL <br />BEARING PRESSURE. MONOLITHIC GRADE BEAMS & THICKENED SLAB SECTIONS SHALL NOT BE LESS THAN 12" WIDE w/ <br />A 450 CHAMFER TO THE SLAB & SHOULD BE BASED F-0" MIN. BELOW THE FINISHED FLOOR ELEVATION & l'-0" MIN. <br />BELOW THE FINAL EXTERIOR GRADES AT 2,500 PSF MAX. ALLOWABLE NET SOIL BEARING PRESSURE ON SOIL <br />IMPROVED BY PROOF -ROLLING NOT LESS THAN THREE COVERAGES. FOR FOOTING WIDTHS OR EMBEDMENTS LESS <br />THAN THOSE SPECIFIED, THE ALLOWABLE BEARING PRESSURES ARE REDUCED PROPORTIONALLY. PERFORM ALL <br />PROOF -ROLLING OPERATIONS IN ACCORD WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER IN <br />THE PRESENCE OF THE OWNER'S AUTHORIZED AGENCY. <br />03100 FORMWORK: <br />CONTRACTOR SHALL DESIGN AND ERECT FORMWORK IN STRICT COMPLIANCE WITH ACI 347. SEE TYPICAL DETAILS <br />FOR CAMBER REQUIREMENTS. CONTRACTOR SHALL COORDINATE ALL OPENINGS AS REQUIRED FOR OTHER TRADES. <br />OPENINGS WHERE SHOWN ON THE STRUCTURAL DRAWINGS ARE TO IDENTIFY DESIGN INTENT ONLY. THE SPECIFIC <br />DIMENSIONS AND LOCATIONS SHALL BE FURNISHED OR CONFIRMED BY THE TRADE REQUIRING THE OPENING. <br />PROVIDE CHAMFERS AT ALL CORNERS IN CONCRETE MEMBERS EXPOSED TO VIEW. FORMWORK TO REMAIN IN PLACE <br />UNTIL CONCRETE HAS ATTAINED ENOUGH STRENGTH TO SUPPORT ALL DEAD LOADS PLUS A MINIMUM OF 50 PSF OF <br />ADDITIONAL CONSTRUCTION LOAD. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />03200 CONCRETE REINFORCEMENT: <br />WORK SHALL BE IN ACCORD WITH THE CURRENT EDITIONS OF ACI 318, ACI 318R, ACI 315, ACI 318, CRSI "MANUAL OF <br />STANDARD PRACTICE", CRSI "PLACING REINFORCING BARS", WIRE REINFORCEMENT INSTITUTE "MANUAL OF <br />STANDARD PRACTICE -STRUCTURAL WELDED WIRE REINFORCEMENT". BARS SHALL CONFORM TO ASTM <br />SPECIFICATION A615(S1), GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. CONCRETE COVER <br />REQUIRED AS FOLLOWS: <br />A. CAST AGAINST AND EXPOSED TO EARTH: 3" <br />B. FORMED, EXPOSED TO EARTH OR WEATHER: 2" (#6 & LARGER) <br />IY" (#5 & SMALLER) <br />C. SLABS AND WALLS: <br />NO EARTH OR WEATHER EXPOSURE 3/4" (#II & SMALLER) <br />3 HOUR FIRE RATING AND LESS %4" <br />LAP SPLICE LENGTHS SHALL BE AS FOLLOWS: <br />1. ALL LAP SPLICES SHALL BE TENSION CLASS "B" UNLESS OTHER LAP CONDITIONS ARE SPECIFICALLY SHOWN ON THE <br />DRAWINGS. <br />2. SPLICE LENGTHS SHALL BE SHOWN ON SHOP DRAWINGS, <br />3. USE GENERAL HOOK BAR DEVELOPMENT LENGTHS UNLESS SPECIAL CONFINEMENT CONDITIONS ARE SATISFIED <br />IN ACCORD WITH ACI 318. <br />03300 CAST -IN -PLACE CONCRETE: <br />TO BE MIXED AND PLACED IN ACCORDANCE WITH THE CURRENT EDITION OF ACI 301. ALL REINFORCED CONCRETE <br />TO HAVE 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />ALL STRUCTURAL ELEMENTS F'c = 4,000 PSI UNLESS NOTED OTHERWISE. <br />• BEAMS & COLUMNS: F'c = 4,000 PSI <br />• FOUNDATIONS: F'c = 3,000 PSI <br />• SLABS ON GRADE: F'c = 3,000 PSI <br />• LIGHTWEIGHT TOPPING: F'c = 2,200 PSI (MIN.) <br />ALL CONCRETE MIX DESIGN SUBMITTALS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE EACH <br />PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. <br />03310 CONCRETE TESTING: <br />OWNER WILL EMPLOY AN INDEPENDENT TESTING LABORATORY TO PERFORM THE FOLLOWING TESTS AND SUBMIT <br />TEST REPORTS ON CAST IN PLACE CONCRETE: <br />• ASTM C143 "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT CONCRETE." SLUMP SHALL NOT <br />EXCEED LIMIT INDICATED ON APPROVED MIX DESIGN, OR 6" (WHICHEVER IS SMALLER) <br />• ASTM C39 "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS." <br />CYLINDERS SHALL BE TAKEN FOR EACH MIX DESIGN USED, AND FOR EVERY 50 CUBIC YARDS OF CONCRETE <br />PLACED. TEST CYLINDERS AT THE FOLLOWING AGES: <br />1 CYLINDER AT 3 DAYS, 1 CYLINDER AT 7 DAYS, 2 CYLINDERS AT 28 DAYS <br />-or- <br />HOLD ONE RESERVE CYLINDER TO BE TESTED AS REQUESTED BY THE ENGINEER. IF REQUIRED <br />28 DAY STRENGTH IS ACHIEVED, THE RESERVE CYLINDER MAY BE DISCARDED. <br />03365 POST -TENSIONED CONCRETE FOR FOUNDATIONS: <br />CONCRETE STRENGTHS AT TRANSFER OF PRESTRESS FORCE TO CONCRETE SHALL BE AT 2,000 PSI (MIN.). THE <br />TENDONS SHALL BE TENSIONED AS SOON AS POSSIBLE AFTER THIS STRENGTH IS REACHED, BUT THE TENDON MUST <br />BE TENSIONED NO LATER THAT 7 DAYS AFTER CONCRETE PLACEMENT. ALL REQUIREMENTS AND <br />RECOMMENDATIONS IN ACI-318-02 AND ACI-ASCE COMMITTEE 423, SHALL APPLY TO THIS WORK. ALL FORCES ARE <br />SHOWN IN KIPS (1,000 LBS). C.G.S. - INDICATES CENTER GRAVITY OF TENDONS, C.G.C. - INDICATES CENTER GRAVITY <br />OF CONCRETE. THE CONSTRUCTION JOINT LOCATION SHALL BE LOCATED FROM THE CENTER LINE OF SUPPORT <br />WHERE THE CGS OF THE TENDONS INTERSECT THE C.G.C. OF THE CONCRETE. THOROUGHLY VIBRATE THE <br />CONCRETE BEHIND ALL TENDON ANCHOR PLATES. PROVIDE BACK-UP REBARS BEHIND ALL ANCHOR PLATES AT <br />CONCRETE EDGES AS DETAILED. SPACING OF TENDONS SHALL BE IN ACCORDANCE WITH ACI-ASCE COMMITTEE 423. <br />PROVIDE CONCRETE COVER ON REBARS AND TENDONS UNLESS DETAILED OTHERWISE. ADEQUATE SUPPORT BARS <br />AND CHAIRS SHALL BE PROVIDED TO DEFINE THE TENDON PROFILE AND TENDONS SHALL BE FIRMLY TIED IN PLACE <br />TO PREVENT DISPLACEMENT BY CONSTRUCTION LOADS AND PLACING OF CONCRETE. THE PLACEMENT TOLERANCE <br />OF TENDONS SHALL BE IN ACCORDANCE WITH ACI-ASCE 423. FASTENERS IN CONCRETE SLABS, REQUIRED FOR OTHER <br />TRADES SHALL BE CAST -IN -PLACE WHERE EVER FEASIBLE. DRILLED -IN FASTENERS MAY BE USED ONLY WHERE TENDONS <br />ARE LOCATED MAGNETICALLY OR BY OTHER MEANS PRIOR TO DRILLING. POWDER -DRIVEN FASTENERS WITH <br />PENETRATION OF Ys" LESS THAN REQUIRED COVER WILL BE PERMITTED. CHLORIDE IN CONCRETE SHALL NOT BE <br />PERMITTED. PROFILES AND FORCES BASED ON Y2" DIAMETER STRANDS (7 WIRE). EFFECTIVE STRESS IN PRESTRESSING <br />STEEL AFTER LOSSES IS ASSUMED TO BE 171 KSI WHICH SHALL BE VERIFIED OR MODIFIED BY CALCULATIONS IN <br />ACCORD WITH ACI-ASCE 423 RECOMMENDATION. YIELD STRENGTH OF PRESTRESSING STEEL = 270 KSI. <br />POST -TENSIONED FORCES SPECIFIED IN THE CONTRACT DRAWINGS ARE REQUIRED EFFECTIVE FORCES AFTER <br />APPROPRIATE LOSSES ARE ACCOUNTED FOR. CALCULATIONS SUBMITTED WITH THE POST -TENSIONING MATERIAL <br />SHOP DRAWINGS SHALL INDICATE THE VALUES FOR ALL LOSSES APPROPRIATE TO THIS PROJECT FOR THE MATERIAL <br />PROPOSED. CERTIFIED TEST DATA SUBSTANTIATING LOSS ASSUMPTIONS SHALL ALSO BE SUBMITTED. NOTE THAT <br />SUBMITTALS INDICATING EFFECTIVE FORCES DIFFERENT FROM THOSE SHOWN ON THE CONTRACT DRAWINGS <br />(SUPPLIER REDESIGN) WILL BE RETURNED, NOT REVIEWED, AS NOT RESPONSIVE TO CONTRACT REQUIREMENTS. ALL <br />STRUCTURAL SUBMITTALS (CALCULATIONS & SHOP DRAWINGS) BY THE POST -TENSIONED SUBCONTRACTOR SHALL BE <br />SIGNED AND SEALED BY THE SPECIALTY ENGINEER. <br />03600 GROUT: <br />GROUTING IS CLASSIFIED AS "PRECISION GROUTING" FOR SUPPORT OF OPERATING MACHINE BASES, EQUIPMENT <br />SUBJECT TO THERMAL MOVEMENT, AND BASE PLATES, BEARING PLATES, AND EXPANSION BEARINGS EXCEEDING 8" IN <br />LEAST DIMENSION. ALL OTHER GROUTING MAY BE "ORDINARY GROUTING". METALLIC AGGREGATE GROUT MAY BE <br />USED ONLY IN INTERIOR APPLICATIONS NOT EXPOSED TO VIEW IN FINISHED BUILDING AREAS. USE ORDINARY <br />CEMENT GROUT ONLY WHERE SPECIFICALLY NOTED AS "CEMENT GROUT" ON DETAILS. USE NON -SHRINK GROUT <br />FOR ALL OTHER LOCATIONS. PRECISION GROUT SHALL CONFORM TO CRD-C621-80 WHEN MIXED TO FLUID <br />CONSISTENCY OF 22 TO 25 SECONDS (FLOW CONE METHOD, CRD-C611-80). REQUIRED 28 DAY STRENGTHS SHALL BE <br />AS FOLLOWS: <br />• CEMENT GROUT: 1,800 PSI <br />• NON -SHRINK GROUT: 5,000 PSI <br />• PRECISION GROUT: 6,500 PSI <br />04220 CONCRETE UNIT MASONRY: <br />ALL MASONRY CONSTRUCTION TO BE IN ACCORDANCE WITH "SPECIFICATION FOR CONCRETE MASONRY <br />CONSTRUCTION", ACI 530-08 & ACI 530.1-08 AND ALL APPLICABLE LOCAL BUILDING CODE PROVISIONS. ALL MASONRY <br />WALLS TO BE CONSTRUCTED ENTIRELY OF UNITS CONFORMING TO ASTM, C 90, AND REINFORCED WITH #9 GAUGE <br />LADDER TYPE HORIZONTAL MASONRY REINFORCING LOCATED AT 16" O.C. ALL MASONRY TO BE LAID 1N TYPE "S" <br />MORTAR (1,800 PSI ON THE JOB) WITH FULL HEAD AND BED JOINTS. ALL MASONRY CONSTRUCTION TO BE EITHER <br />BOUND BY TIE BEAM, TIE COLUMN MEMBERS OR TIED TO FRAME WITH 16 GAUGE CONTINUOUS DOVETAIL SLOT <br />AND 12 GAUGE DOVETAIL ANCHOR SPACED @ 16" O.C. (TOP AND TWO VERTICAL SIDES). <br />04230 REINFORCED UNIT MASONRY: <br />ALL REINFORCED MASONRY CONSTRUCTION SHALL BE IN ACCORD WITH APPLICABLE PROVISIONS OF CONCRETE <br />REINFORCEMENT, CAST -IN -PLACE CONCRETE, AND CONCRETE MASONRY. VERTICAL REINFORCING SHALL ANCHOR <br />INTO SUPPORTING CONCRETE MEMBERS A CLASS "B" LAP LENGTH PLUS 3" OR FULL DEPTH PLUS A STANDARD HOOK. <br />LAPS WITHIN REINFORCED MASONRY SHALL BE 48 BAR DIAMETERS. CONTRACTOR SHALL COORDINATE PLACING OF <br />DOWELS TO ACCOMMODATE MODULE OF MASONRY UNITS. ALL VERTICAL CELLS AND BEAMS WITH REINFORCING <br />SHALL BE FILLED WITH COARSE GROUT CONSISTING OF 3,000 PSI CONCRETE WITH #8 COARSE AGGREGATE. USE <br />HIGH -SLUMP (SUPERPLASTICIZED) WHERE HEIGHT OF LIFT EXCEEDS 5'-0". WHERE HEIGHT OF OPEN CELL EXCEEDS 5-0", <br />USE HIGH -LIFT GROUTING TECHNIQUE WHICH REQUIRES A CLEAN -OUT OPENING AT THE BOTTOM OF ALL CELLS. <br />ALL WALLS TO BE REINFORCED WITH #5 BARS SPACED AT 48" O.C. MAX. VERTICAL, TYP. (U.N.O.) <br />05055 WELDING: <br />ALL WELDING TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY (AWS) Dl.l - <br />2001 "STRUCTURAL WELDING CODE - STEEL" AND AS INDICATED ON THE STRUCTURAL DRAWINGS. WELDING <br />ELECTRODES SHALL BE E70XX, UNLESS NOTED OTHERWISE. WELDING ELECTRODES, WELDING PROCESS, MINIMUM <br />PREHEAT AND INTERPASS TEMPERATURES TO BE IN ACCORDANCE WITH THE A.W.S. SPECIFICATIONS. ANY <br />STRUCTURAL STEEL DAMAGED IN WELDING TO BE REPLACED OR ACCEPTABLY REINFORCED. ALL FULL PENETRATION <br />GROOVE WELDS TO BE SUBJECT TO RADIOGRAPHIC, MAGNETIC PARTICLE, ULTRASONIC, AND LIQUID PENETRANT <br />INSPECTION CONDUCTED BY AN INDEPENDENT TESTING AGENCY PAID FOR BY THE OWNER. <br />05120 STRUCTURAL STEEL: <br />ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST EDITION <br />OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "SPECIFICATIONS FOR THE DESIGN, FABRICATION <br />AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". STRUCTURAL STEEL TO CONFORM TO: <br />• WF SHAPES: ASTM A572, GRADE 50 OR ASTM A992 <br />• SHAPES & PLATES: ASTM A36 <br />• PIPES: ASTM A 53 GRADE B <br />• TUBES: ASTM A 500 GRADE B <br />ALL SHOP AND FIELD CONNECTIONS SHALL BE MADE WITH ASTM A325 HIGH STRENGTH BOLTS OR WELDING. <br />BOLTING TO BE IN ACCORDANCE WITH RCRBSJ SPECIFICATIONS. ANY CONNECTION NOT SPECIFICALLY DETAILED <br />SHALL BE DESIGNED BY THE SPECIALTY ENGINEER FOR THE FORCES SHOWN ON THE STRUCTURAL CONSTRUCTION <br />DOCUMENTS. WHERE FORCES ARE NOT PROVIDED DESIGN SHALL BE BASED ON THE MAXIMUM LOAD CAPACITIES OF <br />THE CONNECTING MEMBERS. ALL STRUCTURAL SUBMITTALS REQUIRING ENGINEERING INPUT SHALL BE <br />ACCOMPANIED BY DESIGN CALCULATIONS AND BE SIGNED AND SEALED BY THE SPECIALTY ENGINEER. ALL STEEL AT <br />AND BELOW FINISHED GRADE TO BE FIELD PAINTED AND COVERED WITH A MINIMUM OF 2" CONCRETE. ALL BEAMS <br />BEARING ON CONCRETE TO HAVE A 8" x 7%" X 8" BEARING PLATE WITH TWO (2) %z' 0 HEADED ANCHOR BOLTS 12" <br />LONG (8" EMBEDMENT), TYPICAL (UNLESS NOTED OTHERWISE). <br />05510 ENGINEERED METAL STAIRS: <br />STACK STEEL STAIR SYSTEM INCLUDING MEMBERS, COMPONENTS, & CONNECTIONS SHALL BE DESIGNED BY A <br />SPECIALTY ENGINEER & DETAILED BY THE SUPPLIER. SUBMIT COMPLETE SHOP DRAWINGS & CALCULATIONS SIGNED & <br />SEALED BY A REGISTERED PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED. DESIGN LOADS <br />SHALL BE A MINIMUM OF 100 PSF UNIFORM OR 300# APPLIED TO ANY 6N6" AREA, WHICHEVER CONTROLS. PROVIDE <br />DETAILS SO THAT STAIR CAN BE ASSEMBLED AND INSTALLED IN PROPER SEQUENCE WITH ADJACENT WORK. METAL <br />PAN STAIR TREADS AND LANDINGS SHALL HAVE NOT LESS THAN 2" NOR MORE THAN 3" OF CONCRETE FILL FOR <br />WALKING SURFACES. COORDINATE WITH ARCHITECTURAL DRAWINGS & MEET ALL APPLICABLE LOCAL BUILDING <br />CODES. <br />05521 ENGINEERED STEEL/ALUMINUM HANDRAILS: <br />STEEL OR ALUMINUM RAILING SYSTEM INCLUDING MEMBERS, COMPONENTS, & CONNECTIONS SHALL BE DESIGNED <br />BY A DELEGATED SPECIALTY ENGINEER & DETAILED BY THE SUPPLIER. SUBMIT COMPLETE SHOP DRAWINGS & <br />CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS <br />LOCATED. THE CONFIGURATION OF THE RAILING SYSTEM SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS. <br />THE RAILING SYSTEM & ALL CONNECTIONS SHALL BE DESIGNED FOR APPLICABLE LOADS AS INDICATED ON THE PLANS <br />AND IN THE BUILDING CODES. ALL LOADS SHALL BE CLEARLY INDICATED ON THE CALCULATIONS & SHOP DRAWINGS. <br />SHOP DRAWINGS SHALL SHOW & SPECIFY ALL CONNECTIONS UTILIZED WITHIN THE RAILING SYSTEM AS WELL AS <br />CONNECTIONS TO & LOADS IMPOSED UPON THE STRUCTURAL FRAMING SYSTEM. <br />sA <br />W <br />3 <br />J <br />�} <br />(aW <br />FORUME <br />+- <br />In <br />05525 ENGINEERED STEEL/ALUMINUM CANOPY/SUNSHADE SYSTEMS: <br />a. <br />ARCHITECTURE & <br />0(0 <br />STEEL OR ALUMINUM CANOPY/SUNSHADE SYSTEM INCLUDING MEMBERS, COMPONENTS, & CONNECTIONS SHALL <br />`C <br />Li <br />INTERIOR DESIGN INC. <br />BE DESIGNED BY A DELEGATED SPECIALTY ENGINEER & DETAILED BY THE SUPPLIER. SUBMIT COMPLETE SHOP <br />z <br />' <br />DRAWINGS & CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE <br />_0 <br />E <br />2PLANNNG <br />I ARCHnECTU� I <br />THE PROJECT IS LOCATED. THE CONFIGURATION OF THE CANOPY/SUNSHADE SYSTEM SHALL BE AS SHOWN ON <br />Q) <br />W <br />THE ARCHITECTURAL DRAWINGS. THE CANOPY/SUNSHADE SYSTEM & ALL CONNECTIONS SHALL BE DESIGNED FOR <br />.0 <br />° <br />APPLICABLE LOADS AS INDICATED ON THE PLANS AND IN THE BUILDING CODES. ALL LOADS SHALL BE CLEARLY <br />';"' <br />2 <br />INDICATED ON THE CALCULATIONS & SHOP DRAWINGS. SHOP DRAWINGS SHALL SHOW & SPECIFY ALL <br />.0 <br />W <br />237 S. Westmonte Drive, Suite 220 <br />CONNECTIONS UTILIZED WITHIN THE CANOPY/SUNSHADE SYSTEM AS WELL AS CONNECTIONS TO & LOADS <br />Altamonte Springs, FL 32714 <br />IMPOSED UPON THE STRUCTURAL FRAMING SYSTEM. <br />3 <br />407.830.1400 <br />UU <br />fy <br />fy <br />www.forumarchitecture.com <br />06110 STRUCTURAL WOOD FRAMING: <br />C <br />ro <br />� <br />ALL DIMENSIONED LUMBER 2" & LESS IN NOMINAL THICKNESS SHALL BE SURFACED DRY & STAMPED BY AN <br />UL <br />a <br />AGENCY CERTIFIED BY THE BOARD OF REVIEW OF THE AMERICAN LUMBER STANDARDS COMMITTEE & <br />0 <br />MANUFACTURED IN ACCORD WITH PS 20-70. MEMBERS THICKER THAN 2" NOMINAL MAY BE SURFACED GREEN. <br />U <br />0 <br />IL <br />MINIMUM SPECIES AND GRADES FOR VISUALLY GRADED DIMENSION LUMBER SHALL BE AS FOLLOWS: <br />to <br />LL <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 2" to 4" WIDE VALUES AS OF JUNE 1, 2013): <br />"' <br />z <br />Zephyr <br />-REVISED <br />Fb = 1,100 PSI, Ft = 675 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,450 PSI, E = 1,400,000 PSI <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 5" to 6" WIDE - REVISED VALUES AS OF JUNE], 2013): <br />Z <br />0 <br />Commons <br />Fb = 1,000 PSI, Ft = 600 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,400 PSI, E = 1,400,000 PSI <br />0 <br />W <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 8" WIDE - REVISED VALUES AS OF JUNE 1, 2013): <br />.0 <br />E <br />Fb = 925 PSI, Ft = 550 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,350 PSI, E = 1,400,000 PSI <br />� <br />o <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 10" WIDE - REVISED VALUES AS OF JUNE 1, 2013): <br />ro <br />N <br />Fb = 800 PSI, Ft = 475 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,300 PSI, E = 1,400,000 PSI <br />Ir <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 12" WIDE -REVISED VALUES AS OF JUNE 1, 2013): <br />X <br />Fb = 750 PSI, Ft = 450 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,250 PSI, E = 1,400,000 PSI <br />0 <br />= <br />- <br />i.- <br />• DOUGLAS FIR -LARCH KD No. 2 GRADE: <br />N <br />o <br />Fb = 1,250 PSI, Ft = 725 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,600 PSI, E = 1,600,000 PSI <br />+j <br />z <br />i+ <br />ALL STUDS & HEADER SHOULDERS SHALL BE ONE PIECE BETWEEN PLATES AND/OR HEADERS. DO NOT USE <br />0 <br />z <br />BLOCKING BETWEEN HEADERS AND SHOULDER WITH SOFTER COMPRESSION PERPENDICULAR (Fcp) THAN <br />REQUIRED FOR HEADER. DO NOT CUT LET -IN BRACING INTO STUDS. PROVIDE G90 GALVANIZED HURRICANE CLIPS <br />v <br />U <br />IN ACCORD WITH LOCAL CODE AT ALL ROOF ANCHORAGES & AT ALL FLOORS, TYPICALLY. <br />tr <br />W <br />L. <br />W <br />i- <br />City of Zephyrhills, FL <br />06115 STRUCTURAL SHEATHING: <br />QJ <br />$ <br />+j <br />Q) <br />N <br />z <br />I <br />I A <br />_. <br />I ! <br />PLYWOOD SHALL CONFORM TO PSI-83 & SHALL BE APA GRADE -STAMPED. ROOF SHEATHING SHALL BE "APA RATED <br />� <br />0 <br />. <br />i� <br />.i <br />, <br />. .. , <br />i <br />" � "' <br />SHEATHING EXTERIOR EXPOSURE", Y2" or %" THICK PER PLAN WITH PLY CLIPS AT JOINTS BETWEEN JOISTS OR <br />< <br />I- <br />,E <br />TRUSSES, TYPICALLY (U.N.O.). FLOOR SHEATHING SHALL BE "APA RATED SHEATHING EXPOSURE 1", 2%2" (MIN.) <br />ro <br />u <br />o <br />� <br />� S <br />THICK TONGUE & GROOVE, TYPICALLY (U.N.O.). WALL SHEATHING SHALL BE APA RATED SHEATHING EXTERIOR <br />0 <br />i <br />I I <br />' <br />� <br />EXPOSURE" 15/ " THICK TYPICALLY U.N.O.. CONFORM TO APA RECOMMENDATIONS FOR INSTALLATION OF <br />32 (U.N.O.). <br />0 <br />o <br />- I "��� � ' <br />.. - -- - - <br />PLYWOOD WALL SHEATHING. PROVIDE P.T. PLYWOOD @ FIRST 48" ABOVE SLAB ON GRADE, TYP. TREAT ALL <br />() <br />,,; <br />2965 WEST STATE ROAD 434. SUITE 100 ■ LONGWOOD, FL 32779 <br />FRAMING IN CONTACT WITH CONCRETE OR MASONRY IN ACCORD WITH AMERICAN WOOD PRESERVER'S <br />U <br />o <br />TEL407/682-2086 FAX 407/682-2386 <br />WWW.SCD-ENG.COM <br />BUREAU LP-2 OR PROVIDEY4' THICK 60 DUROMETER BEARING PAD BETWEEN CONCRETE OR MASONRY AND <br />W <br />W <br />�J%eI1osa,l <br />UNTREATED WOOD MEMBER. <br />C <br />z <br />®\% CR®/I//// <br />- <br />®®®"\ <br />° �0� <br />ORIENTED STRAND BOARD (O.S.B.) SHALL BE APA GRADE -STAMPED. ROOF SHEATHING SHALL BE "APA RATED <br />° <br />� °° ..% , <br />SHEATHING EXTERIOR EXPOSURE", Y2" or 5/" THICK PER PLAN WITH PLY CLIPS AT JOINTS BETWEEN JOISTS OR <br />C <br />0 <br />U <br />a <br />°°°° <br />TRUSSES, TYPICALLY (U.N.O.). FLOOR SHEATHING SHALL BE "APA RATED STURD-I-FLOOR SHEATHING EXPOSURE 1", <br />2Y32" (MIN.) THICK TONGUE & GROOVE, TYPICALLY (U.N.O.). WALL SHEATHING SHALL BE "APA RATED SHEATHING <br />E <br />� <br />m <br />EXTERIOR EXPOSURE", 7/6' THICK, TYPICALLY (U.N.O.). CONFORM TO APA RECOMMENDATIONS FOR <br />INSTALLATION OF O.S.B. SHEATHING. TREAT ALL FRAMING IN CONTACT WITH CONCRETE OR MASONRY IN <br />C <br />>- <br />c <br />®'� °°° 2�7 . <br />TAT ®F e° ,fw <br />ACCORD WITH AMERICAN WOOD PRESERVER'S BUREAU LP-2 OR PROVIDE %4' THICK 60 DUROMETER BEARING PAD <br />'C <br />z <br />%®® °°°�L®V�o��°°" ��� <br />BETWEEN CONCRETE OR MASONRY AND UNTREATED WOOD MEMBER. <br />3 <br />°°�°n°°°`°° �', \ <br />®/ <br />DO <br />• EXTERIOR WALL SHEATHING: <br />a <br />o <br />®p®fig uV���®®®®®® <br />l <br />7/6' O.S.B. SHEATHING FASTENED w/ 8d RING SHANK NAILS @ 6" O.C. @ PANEL EDGES & 12" O.C. <br />_v <br />N <br />W <br />Robert C. Scroggins, P.E. <br />INFIELD, TYP. (U.N.O.) PROVIDE%2" P.T. PLYWOOD @ FIRST 48" ABOVE SLAB ON GRADE. <br />°0 <br />� <br />FL Registration No. 56158 <br />Vz <br />0 <br />This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date <br />• INTERIOR CORRIDOR WALL SHEATHING: <br />w <br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not <br />considered signed and sealed and the signature must be verified on any electronic copies. <br />%8 GYPSUM SHEATHING PER ARCH. DWGS. FASTENED w/ #6 x 1%4' BUGLE HEAD SCREWS @ 6" O.C. @ <br />a <br />0. <br />zz <br />PANEL EDGES & 12" O.C. INFIEED, TYP. (U.N.O.) <br />(a <br />W <br />SET DISTRIBUTIONS: <br />• INTERIOR UNIT & CORRIDOR FLOOR SHEATHING: <br />Q1 <br />,C <br />d <br />I2116/2021 <br />OWNER REVIEW SET <br />%4' O.S.B. TONGUE & GROOVE SHEATHING GLUED & FASTENED w/ 8d RING SHANK NAILS @ 6" O.C. <br />+'' <br />L <br />02/17/2022 <br />-- <br />PERMIT SET <br />@ PANEL EDGES & 12" O.C. INFIELD, TYP. (U.N.O.) <br />z <br />- <br />- <br />-_ - -- <br />+� <br />w <br />-. <br />... ---. <br />• BALCONY FLOOR SHEATHING: <br />7 <br />a- <br />W <br />.._ __ <br />__ <br />Y4" P.T. PLYWOOD TONGUE & GROOVE SHEATHING GLUED & FASTENED w/ 8d RING SHANK NAILS <br />I <br />w <br />___ <br />-_ _ <br />@ 6" O.C. @ PANEL EDGES & 12" O.C. INFIELD, TYP. (U.N.O.) <br />. <br />o <br />a_ <br />_ _ __ -- <br />• ROOF SHEATHING: <br />CC <br />G <br />z <br />o <br />--__ --- - <br />- ___. <br />%" O.S.B. SHEATHING w/ H-CLIPS AS REQ'D. FASTENED w/ 8d RING SHANK or 10d COMMON NAILS @ 6" <br />0 <br />W <br />- <br />- - -. _ _--- <br />O.C. @ PANEL EDGES & 12" O.C. INFIELD, TYP. (U.N.O.) <br />N <br />- _ ____ .__.. __ _._ _ <br />UW <br />Q) <br />0� <br />Q <br />_ - <br />-- - __ <br />06190 ENGINEERED WOOD TRUSSES: <br />.6 <br />0 <br />z <br />L <br />4 <br />- <br />-_ - <br />THIS IS A SYSTEM OF CUSTOM ENGINEERED COMPONENTS AND CONNECTIONS IN ACCORD WITH ALL APPLICABLE <br />0' <br />z <br />- -- <br />STANDARDS OF TRUSS PLATE INSTITUTE, INCLUDING BUT NOT LIMITED TO TPI-78 "DESIGN SPECIFICATION FOR <br />� <br />- - - - <br />METAL PLATE CONNECTED WOOD TRUSSES" AND "INTERIM GUIDELINES", CSP-78 "RECOMMENDED CODE OF <br />� <br />z <br />N <br />__ - __ -- <br />STANDARD PRACTICE," HET-80 "HANDLING AND ERECTING WOOD TRUSSES", BWT-76 "BRACING WOOD TRUSSES", <br />L <br />o <br />QCM-77 "QUALITY CONTROL MANUAL" AND THE DEPARTMENT OF PROFESSIONAL REGULATIONS GUIDELINES. <br />0 <br />o <br />SHEET REVISIONS: <br />THE ENTIRE SYSTEM INCLUDING ALL TRUSSES, CONNECTORS BETWEEN TRUSSES, BRIDGING, TEMPORARY BRACING <br />0:0 <br />FOR ERECTION, ANCHORAGE, AND EMBEDMENTS SHALL BE DESIGNED BY A SPECIALTY ENGINEER. THE REVIEW OF <br />C <br />W <br />z <br />._ <br />ALL STRUCTURAL SUBMITTALS BY THE STRUCTURAL ENGINEER OF RECORD SHALL BE TO INSURE THAT HIS INTENT <br />0 <br />as <br />HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAVE BEEN USED. A COPY OF ALL STRUCTURAL <br />'I;, <br />it <br />-- <br />-- -- - <br />SUBMITTALS WILL BE RETAINED FOR RECORD KEEPING PURPOSES ONLY. TRUSS CALCULATIONS, COMPONENT <br />U <br />� <br />- <br />- -- <br />DRAWINGS, CONNECTOR CALCULATIONS, AND ERECTION PLANS SHALL BE SIGNED AND SEALED BY TRUSS <br />,.. <br />- <br />---. _ <br />ENGINEER AND SUBMITTED TO LOCAL BUILDING OFFICIAL FOR APPROVAL. DESIGN TRUSSES FOR LOADS SHOWN <br />U <br />tw- <br />ON PLANS. IN THE ABSENCE OF LOADS, USE APPLICABLE LOCAL CODE FOR LIVE LOAD AND ACTUAL WEIGHT OF <br />Q) <br />a <br />BUILDING MATERIALS FOR DEAD LOAD. USE PATTERNED AND PARTIAL SPAN LIVE LOADS WHERE REQUIRED TO <br />CL <br />g <br />_ <br />_ ___ --- <br />PRODUCE MAXIMUM FORCE IN ANY TRUSS MEMBER. APPLY NET WIND UPLIFT ON ROOFS WHEN APPLICABLE. <br />"A <br />o <br />- <br />- <br />TRUSS TOP CHORDS SHALL BE GROUP 11 SPECIES LUMBER. EXPOSED TO VIEW TRUSSES SHALL BE OF SELECT <br />'U <br />`L <br />- - <br />- <br />-- - <br />STRUCTURAL GRADE. ALL OTHER GRADE AND SPECIES SELECTION IS AT THE DISCRETION OF THE SUPPLIER. <br />C <br />o <br />--- <br />- <br />- - <br />COORDINATE ALL TRUSS DETAILS WITH ARCHITECTURAL DRAWINGS. FOR CONCEALED TO VIEW TRUSSES, WEB <br />ro <br />i- <br />CONFIGURATIONS WHERE SHOWN ARE SUGGESTIONS AND MAY BE MODIFIED BY THE SUPPLIER FOR ECONOMY. <br />� <br />a. <br />PROVIDE SIMPSON "TSS" PLATE, TAR IMPREGNATED FELT PAPER, OR OTHER SUITABLE VAPOR BARRIER BETWEEN <br />ro <br />o <br />_ <br />� _ . _ _- --__ _ _._ <br />TRUSSES AND CONCRETE OR MASONRY BEARING SURFACES. PROVIDE G90 GALVANIZED HURRICANE ANCHORS <br />LL <br />w <br />- - <br />DESIGNED FOR NET WIND UPLIFT AT ALL BEARINGS. <br />'- <br />-_ .. - <br />+ <br />- - __ - <br />v <br />W <br />.0 <br />< <br />- <br />06200 GLUE LAMINATED WOOD PRODUCTS: <br />z <br />OJ <br />bQ <br />z <br />-. <br />_ .... <br />THIS IS A SYSTEM OF CUSTOM ENGINEERED WOOD COMPONENTS MANUFACTURED BY BOISE CASCADE, LLC WITH <br />- <br />- <br />THE FOLLOWING CERTIFIED MINIMUM PROPERTIES: <br />N <br />W <br />- <br />-r <br />r <br />r <br />- - <br />-- - <br />• VERSA -LAM 1.8 2750 SP BEAMS <br />zz <br />E = 1,800,000 PSI, Fb = 2,750 PSI, Fv = 285 PSI, Ft = 1,650 PSI, Fc (PARALLEL) = 3,000 PSI, Fc (PERP.) = 750 PSI <br />0 <br />C <br />r <br />EDITED BY: RCS, TLW <br />• VERSA -LAM 2.0 3100 SP BEAMS <br />l <br />' <br />SC&D PROJECT NO. 21-020 <br />E = 2,000,000 PSI, Fb = 3,100 PSI, Fv = 285 PSI, Ft = 1,650 PSI, Fc (PARALLEL) = 3,000 PSI, Fc (PERP.) = 750 PSI <br />FORUM PROJECT NO. 4097 <br />S <br />• VERSA -LAM 1.8 2750 SP COLUMNS &STUDS <br />nN <br />C <br />N <br />= <br />E = 1,800,000 PSI, Fb = 2,750 PSI, Fv = 285 PSI, Ft = 1,650 PSI, Fc (PARALLEL) = 3,000 PSI, Fc (PERP.) = 750 PSI <br />- <br />I-- <br />C <br />U <br />SEE PLAN FOR BEAM SIZES. ALL WOOD BEAMS WITH THE PREFIX PL ARE TO BE CONSTRUCTED AS PARALLAM <br />W <br />BEAMS, TYP. (UNLESS NOTED OR DETAILED OTHERWISE) <br />C <br />0 <br />W <br />General <br />Q)2 <br />0 <br />Structural Notes <br />Q <br />ix <br />w <br />Q) <br />L <br />�- <br />z <br />+j <br />ca <br />4. <br />0 <br />W <br />:D <br />V�i <br />w <br />Ql <br />F- <br />.0 <br />T <br />U <br />4jD <br />S3.01 <br />a <br />0 <br />0 <br />LL <br />O <br />__11111111111111111111111111111111111 <br />