SHEET NOTES <br />2 A6.11 A7.01 2 <br />294'-11 IR' OVFRAI I Rim SING <7IMFNgm <br />48'-2 7/8" <br />37'-2" 37'-2" <br />oo <br />37'-2" 24'-11 1/2" 40'-3" <br />`1 1/2" <br />1 1/2" <br />1 <br />A6.11 <br />Fourth Floor Plan <br />Building Type I <br />2 2 <br />A6.11 A7.01 <br />3/32" = 1'-0" <br />_ T <br />224'-11 3/8" OVERALL BUILDING DIMENSION <br />ol <br />48'-2 7/8" <br />37'4' <br />37'-2" <br />37'4" <br />24'-11 1/2" <br />40'-3" <br />7.1 <br />oe <br />(11 <br />1 1 /2" AV% <br />1 112" <br />WW-5 <br />TYP <br />0 <br />N <br />TYP <br />WW 9 <br />TYP 19 <br />WW 3 r <br />r <br />~ <br />TYP <br />WW-51 <br />IL — <br />UNIT C1 <br />vuW-S�TYP <br />UNIT B5 <br />UNIT B2 <br />UNIT B2 <br />UNIT Al <br />UNIT B3 <br />M <br />WW 1 <br />I <br />I <br />IAF_ <br />I <br />LIM <br />2 I <br />A8.01 <br />a o I <br />— <br />L1 ElTYP <br />2 <br />A5.81DD <br />(a <br />tyy- <br />M <br />� <br />C <br />L <br />q <br />I <br />I � <br />0 <br />L <br />J <br />oI° <br />J <br />— <br />0 <br />a <br />oI° iXi <br />X �- <br />EL <br />J <br />V <br />°ob <br />BUILDING 0 <br />ERVICES <br />I— <br />o°El <br />° <br />J <br />a <br />0 <br />b0 <br />I <br />Z <br />1350 <br />33 <br />— <br />— <br />9'-0 7/8" <br />102'-3" <br />1Y- <br />" <br />12'-2" <br />84'-01/2" <br />0 <br />o <br />7'-1" <br />4 <br />4 <br />A7.01 <br />T-1" Q <br />`= % <br />WW 52 <br />2" <br />2" <br />M <br />J <br />131 <br />132 <br />IRS <br />T <br />'STAI <br />o <br />op <br />Oo <br />° <br />o <br />El <br />o <br />° <br />00 <br />� <br />Lj <br />— <br />o <br />�o:1> <br />�° <br />q <br />IZIA�_i <br />1LjI <br />I <br />I <br />A7.01 - <br />oco <br />� <br />BB- <br />' <br />TYP WW-53 <br />UNIT A2 <br />2 <br />UNIT Al <br />UNIT Al <br />UNIT Al <br />UNIT B4 <br />WW-54 <br />UNIT B1 <br />UNIT A2 <br />A <br />w <br />a <br />o <br />ti <br />bo <br />w <br />a <br />o <br />1 <br />TYP <br />coTYP <br />1 <br />WW-1 <br />WW-9 <br />A8.11. <br />p <br />02 <br />04 <br />02 <br />0 <br />1 <br />1 <br />1 3/4" <br />1/2" <br />25'-1" <br />1 3/4" <br />- <br />1/2" <br />24'-11 1/2" <br />1 1/2" <br />24'-11 1/2" 24'-11 1/2" 1 112" <br />37'-2" <br />1/2" <br />39'-3" <br />1 34' 1 3/4" <br />- <br />112" <br />25' 1" <br />1'-11 71R" <br />Third Floor Plan <br />Building Type I <br />3/32" = 1'-0" <br />A REFER TO SHEETA1.03 FOR GENERAL NOTES <br />B REFER TO SHEET A1.04 AND A1.05 FOR CONSTRUCTION ASSEMBLIES <br />C REFER TO SHEETS A5.61 THRU A5.69 FOR UNIT PLANS <br />D REFER TO SHEETS A9.11, A9.21 AND A9.31 FOR DOOR, WINDOW AND <br />STOREFRONT SCHEDULES <br />E REFER TO STRUCTURAL DRAWINGS FOR BEARING AND SHEAR WALL <br />LOCATIONS <br />F ALL EXTERIOR WALLS SHALL BE WWA, UNO <br />G ALL UNIT TO CORRIDOR WALLS SHALL BE WW-52, UNO <br />H ALL INTERIOR BEARING / SHEAR WALLS SHALL BE WW-50, LINO <br />J ALL INTERIOR NON -BEARING / NON -SHEAR WALLS SHALL BE WW-51, UNO <br />K ALL EXTERIOR TENANT SEPARATION WALLS SHALL BE WW-9 AND <br />INTERIOR TENANT SEPARATION WALLS TO BE WW-54, UNO <br />L OPENINGS INTO AND/OR THROUGH INTERIOR WALLS REQUIRED TO BE <br />RATED AS BUILDING ELEMENTS AND NOT FOR SEPARATION SHALL BE <br />PROTECTED BY WRAPPING CONTINUOUS FIRE -RATED GYPSUM BOARD <br />INTO/THROUGH OPENING, OR BY OTHER APPROVED FIRE PROTECTIVE. <br />COORDINATE WITH MECHANICAL, ELECTRICAL, AND DOOR DETAIL <br />DRAWINGS <br />M REFER TO SHEETS A5.10 AND A5.20 FOR ARCHITECTURAL SLAB PLANS <br />WITH GROUND FLOOR SPOT ELEVATIONS. UPPER FLOOR SPOT <br />ELEVATIONS ARE DENOTED FROM TOP OF UNIT GYPSUM TOPPING. <br />REFER TO SECTIONS AND DETAILS <br />N MAINTAIN UNIFORM MAX 2% SLOPE WHERE SLOPES ARE INDICATED, <br />UNO <br />P REFER TO ENLARGED PLAN DETAILS FOR ADDITIONAL INFORMATION <br />Q REFER TO SHEET A5.91- A5.93 FOR COMMON & PUBLIC AREAS <br />ACCESSIBILITY REQUIREMENTS DIAGRAMS <br />KEYNOTES <br />01 FLOOR DRAIN, REFER TO PLUMBING DRAWINGS FOR SPECIFICATION <br />AND DETAILS, SLOPE SLAB TO DRAIN, 2% MAX, PROVIDE CONTROL JOINT <br />3 AT EACH DRAIN PERPENDICULAR TO CORRIDOR, LOCATE AT -0'-1/2" AFF, <br />A6.11 UNO <br />02 LOW ROOF, SLOPE 5:12, UNO, REFER TO EXTERIOR ELEVATIONS AND <br />STRUCTURAL DRAWINGS <br />03 STONE VENEER <br />04 PREFABRICATED SOLID AWNING W/ INTEGRAL GUTTER. CONTRACTOR <br />TO COORDINATE WITH AND PROVIDE BLOCKING FOR ALL CONNECTIONS <br />AS REQUIRED PER MFR INSTALLER. SUBMIT SHOP DRAWINGS FOR <br />ARCHITECT TO REVIEW AND COORDINATION OF WATER PENETRATION <br />DETAILS <br />05 42" HIGH GUARDRAIL, REFER TO ENLARGED PLANS FOR DETAILS 7/A8.12 <br />06 ELECTRICAL SERVICE I METER, REFER TO ELECTRICAL DRAWINGS <br />07 STANDPIPE / HOSE VALVE CONNECTION, REFER TO CONTRACTOR'S FIRE <br />PROTECTION DRAWINGS <br />08 2X6 WALL <br />09 REFER TO CIVIL DRAWINGS FOR DOWNSPOUT CONNECTIONS TO <br />UNDERGROUND STORM WATER SYSTEM. CONTRACTOR TO PROVIDE <br />CONCRETE SPLASH BLOCKS AT ALL LOCATIONS NOT TIED TO <br />UNDERGROUND STORM WATER SYSTEM <br />10 DOWNSPOUT TO TERMINATE AT SPLASHBLOCK <br />11 CONCRETE A/C PAD (4" THICK), SLOPE AWAY FROM BUILDING, REFER TO <br />SITE PLAN FOR SCHEMATIC PAD LAYOUT AND TO MECHANICAL <br />DRAWINGS FOR A/C CONDENSER DETAILS, CONTRACTOR SHALL <br />COORDINATE FINAL PLACEMENT WITH CIVIL AND LANDSCAPE <br />LEGEND <br />WALL INDICATES SPECIFIC WALL TYPE <br />I� FIRE EXTINGUISHER IN CABINET, REFER TO <br />FE GENERAL NOTES <br />INT. LOAD BRG. WALLS COORD. <br />W/ STRUCTURAL DRAWINGS <br />1REMOVEmmwf <br />ROM UNITS &ADDED FORRIDOR.GC TOO A1.03 <br />RESIDENTIAL BLDG TYPE <br />I <br />BLDG # ON SITE <br />3, 4, 5 <br /># UNITS / BLDG TYPE <br />52 (3 TOTAL ON SITE) <br />AIC <br />NON -A/C <br />GROSS <br />1ST FLOOR <br />13,650 <br />1,686 <br />15,336 <br />2ND FLOOR <br />13,647 <br />1,485 <br />1 15,132 <br />3RD FLOOR <br />13,647 <br />1,485 <br />15,132 <br />4TH FLOORS <br />13,647 <br />1,485 <br />15,132 <br />BUILDING TOTAL <br />54,591 <br />6,141 <br />60,732 <br />QUANTITY ON SITE <br />3 <br />TOTAL SF ON SITE <br />182,196 <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />z� SHEET REVISIONS: <br />r PROJECT NO. 4097 <br />U <br />z <br />Building Type I - <br />Third & Fourth <br />Floor Plan <br />A5.12 <br />