My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Gall Blvd - Zephyr Commons Bldg (3)
Zephyrhills
>
Building Department
>
Building Plans
>
Gall Blvd - Zephyr Commons Bldg (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 2:28:29 PM
Creation date
1/21/2025 4:01:34 PM
Metadata
Fields
Template:
Building Plans
Location
Gall Blvd - Zephyr Commons Bld
Contractor
Forum Architecture
Description
Building Type I
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING: Type II ATTIC SPACE: <br />QUIRED NFA VENTILATION <br />Attic area (Including Soffit): <br />NFA required (Attic Area / 300): <br />Total required ventilation area in SI (Net Free Area X 144): <br />QUIRED UPPER VENTILATION (40% TO 50% OF TOTAL REQ'D) <br />0% OF 1390 ) TO (50% OF 1390 ) = 556 SI TO 695 SI <br />1) 4 Ft Flamco Off -Ridge Vents X 138 SI/vent = <br />2) 6 Ft Flamco Off -Ridge Vents X 210 SI/vent = <br />Ipper Ventilation Provided: <br />;EQUIRED LOWER VENTILATION (TOTAL RE( <br />1390 SI - 558 SI = <br />ROPOSED LOWER VENTILK <br />IFR: Tamlyn Model: <br />otal LF of soffit to be installed: <br />�q. In. NFA per LF of soffit: <br />ower Ventilation Provided: <br />ROPOSED UPPER VENTILAI <br />558 SI / 1390 SI = 40.14% <br />ROPOSED LOWER VENTILA <br />855 SI I 1390 SI = 61.51% <br />2x BLOCKING AROUND <br />PERIMETER OF OPENING <br />SPRING HINGE <br />E M. BUILDING: Type II ATTIC SPACE <br />REQUIRED NFA VENTILATION <br />2894SF Attic area (Including Soffit): <br />9.65 SF NFA required (Attic Area 1300): <br />1390 SI Total required ventilation area in SI (Net Free Area X 144): <br />REQUIRED UPPER VENTILATION (40% TO 50% OF TOTAL REQ'D) <br />(40% OF 1153 ) TO (50% OF 1153) = 461 SI TO 577 SI <br />PROPOSED UPPER VENTILATION <br />138 SI (2) 4 Ft Flamco Off -Ridge Vents X 138 SI/vent = <br />420 SI ( 1 ) 6 Ft Flamco Off -Ridge Vents X 210 SI/vent = <br />558 SI Upper Ventilation Provided: <br />REQUIRED LOWER VENTILATION (TOTAL REQ'D-PROPOSED UNDER) <br />832 SI 1153 SI - 486 SI = <br />PROPOSED LOWER VENTILATION <br />2" Snapvent <br />MFR: Tamlyn Model: 2" Snapvent <br />95 LF <br />Total LF of soffit to be installed: <br />9 / LF <br />Sq. In. NFA per LF of soffit: <br />855 Si <br />Lower Ventilation Provided: <br />% OF REQ'D 40%-50%) <br />PROPOSED UPPER VENTILATION % OF REQ'D 40%-50%) <br />486 SI / 1153 SI = 42.15% <br />% OF REQ'D <br />PROPOSED LOWER VENTILATION % OF REQ'D <br />675 SI / 1153 SI = 58.54% <br />1413 SI <br />TOTAl VFNTII ATION PRr1VInFr). <br />WOOD SHEATHING <br />DRAFTSTOP DOOR <br />D raftsto p Door Detail <br />Roof Plan <br />Building Type II <br />ROOF TRUSS <br />\—DRAFTSTOPPING <br />i PROVIDE AUTOMATIC <br />LATCH FOR <br />DRAFTSTOP DOOR <br />i <br />1-1/2" = 1'-0" <br />D BUILDING: Type II ATTIC SPACE: <br />REQUIRED NFA VENTILATION <br />2404 SF Attic area (Including Soffit): <br />8.01 SF NFA required (Attic Area / 300): <br />1153 SI Total required ventilation area in SI (Net Free Area X 144): <br />REQUIRED UPPER VENTILATION (40% TO 50% OF TOTAL REQ'D) <br />(40% OF 1384 ) TO (50% OF 1384) = 554 SI TO 692 SI <br />PROPOSED UPPER VENTILATION <br />276 SI (1 ) 4 Ft Flamco Off -Ridge Vents X 138 SI/vent = <br />210 SI (2) 6 Ft Flamco Off -Ridge Vents X 210 SI/vent = <br />486 SI Upper Ventilation Provided: <br />REQUIRED LOWER VENTILATION (TOTAL REQ'D-PROPOSED UNDER) <br />667 SI 1384 SI - 558 SI = <br />PROPOSED LOWER VENTILATION <br />MFR: Tamlyn Model: 2" Snapvent <br />75 LF Total LF of soffit to be installed: <br />9 / LF Sq. In. NFA per LF of soffit: <br />675 SI Lower Ventilation Provided: <br />PROPOSED UPPER VENTILATION % OF REQ'D 40%-50%) <br />558 SI / 1384 SI = 40.32% <br />PROPOSED LOWER VENTILATION % OF REQ'D <br />855 SI 11384 SI = 61.78% <br />161 Si <br />C <br />LBUILDING: Type II ATTIC SPACE: <br />B <br />E BUILDING: Type II ATTIC SPACE: <br />A <br />1 <br />SHEET NOTES <br />REQUIRED NFA VENTILATION <br />REQUIRED NFA VENTILATION <br />A <br />REFER TO SHEET A1.03 FOR GENERAL NOTES <br />2883 SF <br />Attic area (Including Soffit): <br />2597SF <br />Attic area (Including Soffit): <br />2162 S <br />9.61 SF <br />NFA required (Attic Area / 300): <br />8.66 SF <br />NFA required (Attic Area / 300): <br />7.21 S <br />B <br />ALL ROOF SLOPES TO BE 5:12, UNO <br />1384 SI <br />Total required ventilation area in SI (Net Free Area X 144): <br />1247 SI <br />Total required ventilation area in SI (Net Free Area X 144): <br />1038 SI <br />C <br />ALL EAVE OVERHANGS TO BE V-4', UNO <br />REQUIRED UPPER VENTILATION 40% TO 50% OF TOTAL REQ'D) <br />REQUIRED UPPER VENTILATION (40% TO 50% OF TOTAL REQ'D) <br />D <br />ALL RAKE AND GABLE OVERHANGS TO BE 8", LINO <br />(40% OF 1247 ) TO (50% OF 1247) = 499 SI TO 624 SI <br />(40% OF 1038 ) TO (50% OF 1038) = 415 SI TO 519 SI <br />E <br />REFER TO CIVIL DRAWINGS FOR DOWNSPOUT CONNECTIONS TO <br />PROPOSED UPPER VENTILATION <br />PROPOSED UPPER VENTILATION <br />UNDERGROUND STORM WATER SYSTEM, CONTRACTOR TO PROVIDE <br />138 SI <br />( 1 ) 4 Ft Flamco Off -Ridge Vents X 138 SI/vent = <br />138 SI <br />(0) 4 Ft Flamco Off -Ridge Vents X 138 SI/vent = <br />0 S <br />CONCRETE SPLASH BLOCKS AT ALL LOCATIONS NOT TIED TO <br />420 SI <br />( 2 ) 6 Ft Flamco Off -Ridge Vents X 210 SI/vent = <br />420 SI <br />(2) 6 Ft Flamco Off -Ridge Vents X 210 SI/vent = <br />420 S <br />UNDERGROUND STORM WATER SYSTEM <br />558 SI <br />Upper Ventilation Provided: <br />558 SI <br />Upper Ventilation Provided: <br />420 S <br />F <br />REFER TO STRUCTURAL DRAWINGS FOR ALL ROOF TRUSS <br />REQUIRED LOWER VENTILATION (TOTAL REQ'D-PROPOSED UNDER) <br />REQUIRED LOWER VENTILATION (TOTAL REQ'D-PROPOSED UNDER) <br />REQUIREMENTS AND DETAILS <br />826 SI <br />1247 SI - 558 SI = <br />689 SI <br />1038 SI - 420 SI = <br />618 S <br />G <br />LOW -SLOPE ROOF TRUSSES SHALL HAVE A TOP CHORD SLOPED AT A <br />MIN 1/4" PER FOOT TO ACHIEVE THE PRIMARY ROOF SLOPE, ROOF <br />PROPOSED LOWER VENTILATION <br />PROPOSED LOWER VENTILATION <br />INSULATION SHALL BE PITCHED TO CREATE CRICKETS TO THE ROOF <br />MFR: Tamlyn Model: 2" Snapvent <br />MFR: Tamlyn Model: 2" Snapvent <br />DRAINS AT 3:1 LENGTH -TO -WIDTH RATIO <br />95 LF <br />Total LF of soffit to be installed: <br />80 LF <br />Total LF of soffit to be installed: <br />70 L <br />9 / LF <br />Sq. In. NFA per LF of soffit: <br />9 / LF <br />Sq. In. NFA per LF of soffit: <br />9 / LF <br />H <br />DOWNSPOUTS SHALL NOT TERMINATE ABOVE GRADE UNLESS <br />855 SI <br />Lower Ventilation Provided: <br />720 SI <br />Lower Ventilation Provided: <br />630 S <br />DISCHARGED DIRECTLY INTO GUTTER OF LOWER ROOF, DOWNSPOUTS <br />SHALL NOT DISCHARGE DIRECTLY ONTO A SIDEWALK OR BUILDING <br />PROPOSED UPPER VENTILATION % OF REQ'D 40%-50%) <br />PROPOSED UPPER VENTILATION % OF REQ'D 40%-50%u) <br />ACCESS <br />558 SI 1 1247 SI = 44.75% <br />420 SI 11038 Sl = 40.46% <br />J <br />DOWNSPOUTS OVER LOW ROOFS SHALL DISCHARGE IN THE DIRECTION <br />PROPOSED LOWER VENTILATION % OF REQ'D <br />PROPOSED LOWER VENTILATION % OF REQ'D <br />OF SLOPE <br />720 SI / 1247 SI = 57.74% <br />630 SI / 1038 SI = 60.69% <br />T T L V I T 0 PR V D D 1278 SI KEYNOTES PD D <br />01 OFF -RIDGE VENT, REFER TO SPECIFICATIONS <br />KEY PLAN 02 SEAMLESS ALUMINUM "A" PROFILE GUTTER, COLOR SELECTED BY <br />OWNER <br />03 3"X4" RECTANGULAR ALUMINUM DOWNSPOUT, LOCATIONS ARE <br />APPROXIMATE, CONTRACTOR TO COORDINATE CAPACITY AND <br />LOCATIONS WITH CIVIL, DOWNSPOUTS TERMINATE INTO STORM <br />DRAINAGE SYSTEM, UPPER GUTTER TO DISCHARGE INTO LOWER <br />GUTTERS, COLOR SELECTED BY OWNER <br />A 04 LOLAW ROOF, ROOF SLOPE 5:12 LINO, REFER TO ELEVATIONS OR BUILDING <br />° 05 22"X36" 1-HOUR FIRE -RATED LOCKABLE ATTIC ACCESS PANEL, <br />D-D-D- D-D-D -D D D-D-D -D-D-D COORDINATE LOCATION WITH REFLECTED CEILING PLAN AND ROOF <br />TRUSS FABRICATOR <br />C i D j E 06 22"X36" SELF -CLOSING DRAFTSTOPPING DOOR, REFER TO DETAIL 2/A5.13 <br />07 PREFABRICATED SOLID AWNING W/ INTEGRAL GUTTER, REFER TO <br />° ELEVATIONS OR BUILDING PLANS <br />° <br />LEGEND <br />3 <br />A6.21 <br />3/32" = 1'-0" <br />ATTIC ACCESS <br />m=� DOWNSPOUT <br />4 J OFF -RIDGE ROOF VENTS PER ATTIC VENTILATION <br />— — — — -1 REQUIREMENTS <br />6J <br />-D—D— DRAFTSTOPPING PER ASSEMBLY <br />° SELF -CLOSING 22"x36" DRAFTSTOP ACCESS DOOR <br />1 W/ AUTOMATIC LATCH <br />RESIDENTIAL BLDG TYPE <br />II <br />BLDG # ON SITE <br />1,2 <br /># UNITS / BLDG TYPE <br />48 (2 TOTAL ON SITE) <br />A/C <br />NON -A/C <br />GROSS <br />1ST FLOOR <br />12,652 <br />1,641 <br />14,293 <br />2ND FLOOR <br />12,650 <br />1,439 <br />14,089 <br />3RD FLOOR <br />12,650 <br />1,439 <br />14,089 <br />4TH FLOORS <br />12,650 <br />1,439 <br />14,089 <br />BUILDING TOTAL <br />50,602 <br />5,958 <br />56,560 <br />QUANTITY ON SITE <br />2 <br />TOTAL SF ON SITE <br />113,120 <br />aFORUME <br />o ARCHITECTURE & <br />a <br />INTERIOR DESIGN, INC. <br />C <br />c <br />m <br />a� <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />S 407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />AR0017018 <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Building Type II - <br />Roof Plan <br />A5.23 <br />