My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Gall Blvd - Zephyr Commons Bldg (3)
Zephyrhills
>
Building Department
>
Building Plans
>
Gall Blvd - Zephyr Commons Bldg (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 2:28:29 PM
Creation date
1/21/2025 4:01:34 PM
Metadata
Fields
Template:
Building Plans
Location
Gall Blvd - Zephyr Commons Bld
Contractor
Forum Architecture
Description
Building Type I
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIT FINISH SCHEDULE <br />SHEET NOTES <br />BD PER ASSEMBLY <br />WATER RESISTANT CEMENT BD OR <br />GLASS -MAT FACED GYP TILE BACKER BD <br />IS REQUIRED BEHIND TILE AT WET AREAS <br />TUB SURROUND <br />PRE -ROCK ALL WALLS SURROUNDING <br />TUB I SHOWER PER ASSEMBLY <br />TUB <br />Tub/Shower at All Adjacent Walls <br />NTS <br />LIGHT FIXTURE <br />(ABOVE MIRROR) <br />46" HIGH MIRROR, <br />WIDTH TO MATCH VANITY <br />0 <br />VSB36 <br />00 <br />BATH WI TUB IN <br />ADAPTABLE BATHROOMS <br />Cabinets & Accessory Heights <br />OUIS <br />24" <br />CA <br />O <br />COUNTERTOP SECTION DETAIL <br />,Cabinet Blocking [detail <br />FLOORING TRANSITION PER ID, <br />COORDINATE LOCATION WITH POUR BREAK <br />TO OCCUR ON UNDERLAYMENT SIDE LVT FLOORING <br />CARPET AND PAD GYPSUM TOPPING <br />GYPSUM ACOUSTICAL <br />TOPPING 314"MIN `UNDERLAYMENT <br />SUBFLOOR` WOOD POUR STOP OR <br />MFR ACCESSORY <br />METER ISOLATION <br />IF PROVIDED, THE ACOUSTICAL UNDERLAYMENT NOT REQUIRED IN CARPETED AREAS <br />Acoustical Underlayment Transition <br />at Unit <br />O <br />CABINET BLOCKING DETAIL <br />LO <br />v <br />in <br />SHELVES <br />AS NEEDED <br />:T <br />AS NEEDED <br />JNTERTOP <br />AS NEEDED <br />�n <br />,ABINET <br />SINGLE SHELF <br />IN LAUNDRY & <br />W/H <br />3" = 1'-0" <br />VINYL COATED <br />WIRE SINGLE SHELF <br />VINYL COA <br />WIRE SHEL\ <br />W/ HANGING I <br />CLOSETS <br />0 <br />CD <br />C, <br />COAT <br />CLOSETS <br />FLOOR <br />BASE <br />WALL <br />CEILING <br />� <br />o <br />o <br />z <br />o <br />w <br />z <br />o <br />z <br />w <br />z <br />Z <br />ZE <br />U <br />z <br />U <br />(D <br />Z <br />z <br />LL <br />Z <br />Y <br />U) <br />w <br />g <br />a <br />*- <br />U_ <br />o <br />o= <br />cn <br />�- <br />Z <br />3: <br />of <br />w <br />0>- <br />0 <br />z <br />V <br />Q <br />a= <br />F <br />H <br />z <br />_ <br />V <br />� <br />0 <br />0 <br />p <br />wU <br />U, <br />m <br />zUj <br />z <br />QfZ <br />0JZMD_ZZ <br />O <br />m <br />LU <br />ZzX <br />0 <br />a3 <br />d <br />ZwLU <br />� <br />0 <br />ZU <br />AREA NAME <br />1 <br />2 <br />3 <br />4 <br />5 <br />1 <br />2 <br />3 <br />1 <br />2 <br />3 <br />1 <br />2 <br />3 <br />COMMENTS <br />ENTRY <br />2 <br />1 <br />2 <br />1 <br />LIVING ROOM <br />2 <br />1 <br />2 <br />1 <br />DINING ROOM <br />2 <br />1 <br />2 <br />1 <br />KITCHEN <br />2 <br />1 <br />2 <br />1 <br />BEDROOM(S) <br />4* <br />1 <br />2 <br />1 <br />BATHROOM(S) <br />2 <br />1 <br />2 <br />1 <br />LAUNDRY ROOM <br />2 <br />1 <br />2 <br />1 <br />MECH CLOSET <br />2 <br />3 <br />2 <br />1 <br />GARAGE <br />3 <br />2 <br />1 <br />BALCONY <br />1 <br />3 <br />1 <br />1 <br />-SCHEDULE IS PRELIMINARY FOR PRICING. GC TO VERIFY ALL FINISHES, LAYOUTS & LOCATIONS WITH OWNER <br />-ALL VINYL PLANK AND CERAMIC TILE INSTALLATIONS AT UPPER FLOORS TO BE INSTALLED WITH SOUND MAT UNDER GYPCRETE TESTED FOR <br />STC/IIC RATINGS OF 50 OR BETTER ON ASSEMBLIES IDENTICAL TO SPECIFIED. ADDITIONALLY, IT IS RECOMMENDED THAT TILE BE INSTALLED ON <br />A SURFACE SOUND MAT, LVT BE PROVIDED WITH AN INTEGRAL SOUND CONTROL BACKING. <br />-REFER TO EXHIBIT H ON A1.06 FOR SPECIFIC FLOORING MATRIX <br />-*REFER TO OWNER FOR ANY "SIGNATURE UNIT" FINISH UPGRADES AND QUANTITIES/LOCATIONS. CONTRACTOR TO COORDINATE SPECIFIC <br />UNITS WITH OWNER WHERE LVT WILL BE UTILIZED IN LIEU OF CARPET AT BEDROOM AND BEDROOM CLOSETS, TO ACCOUNT FOR <br />APPROXIMATELY 30% OF THE PROJECT UNITS. <br />SHELF ONLY <br />TO CLOSETS <br />THAN 24" WITH <br />'ROVIDING LESS <br />32" CLEARANCE <br />3/8" = 1'-0" <br />Enlarged Floor Plan <br />at Second & Third Floor <br />3/8" = 1'-0" <br />A REFER TO SHEET A1.03 FOR GENERAL NOTES <br />B REFER TO SHEET A1.04 AND A1.05 FOR CONSTRUCTION ASSEMBLIES <br />C REFER TO SHEETS A5.61 THRU A5.69 FOR UNIT PLANS <br />D REFER TO SHEETS A9.11, A9.21 AND A9.31 FOR DOOR, WINDOW AND <br />STOREFRONT SCHEDULES <br />E REFER TO STRUCTURAL DRAWINGS FOR BEARING AND SHEAR WALL <br />LOCATIONS <br />F ALL EXTERIOR WALLS SHALL BE WW-1, UNO <br />G ALL UNIT TO CORRIDOR WALLS SHALL BE WW-52, LINO <br />H ALL INTERIOR BEARING / SHEAR WALLS SHALL BE WW-50, UNO <br />J ALL INTERIOR NON -BEARING / NON -SHEAR WALLS SHALL BE WW-51, LINO <br />K ALL EXTERIOR TENANT SEPARATION WALLS SHALL BE WW-9 AND <br />INTERIOR TENANT SEPARATION WALLS TO BE WW-54, LINO <br />L OPENINGS INTO AND/OR THROUGH INTERIOR WALLS REQUIRED TO BE <br />RATED AS BUILDING ELEMENTS AND NOT FOR SEPARATION SHALL BE <br />PROTECTED BY WRAPPING CONTINUOUS FIRE -RATED GYPSUM BOARD <br />INTO/THROUGH OPENING, OR BY OTHER APPROVED FIRE PROTECTIVE. <br />COORDINATE WITH MECHANICAL, ELECTRICAL, AND DOOR DETAIL <br />DRAWINGS <br />M REFER TO SHEETS A5.10 AND A5.20 FOR ARCHITECTURAL SLAB PLANS <br />WITH GROUND FLOOR SPOT ELEVATIONS. UPPER FLOOR SPOT <br />ELEVATIONS ARE DENOTED FROM TOP OF UNIT GYPSUM TOPPING. <br />REFER TO SECTIONS AND DETAILS <br />N MAINTAIN UNIFORM MAX 2% SLOPE WHERE SLOPES ARE INDICATED, <br />UNO <br />P REFER TO ENLARGED PLAN DETAILS FOR ADDITIONAL INFORMATION <br />Q REFER TO SHEET A5.91 - A5.93 FOR COMMON & PUBLIC AREAS <br />ACCESSIBILITY REQUIREMENTS DIAGRAMS <br />KEYNOTES <br />01 FLOOR DRAIN, REFER TO PLUMBING DRAWINGS FOR SPECIFICATION <br />AND DETAILS, SLOPE SLAB TO DRAIN, 2% MAX, PROVIDE CONTROL JOINT <br />AT EACH DRAIN PERPENDICULAR TO CORRIDOR, LOCATE AT 4-1/2" AFF, <br />LINO <br />02 LOW ROOF, SLOPE 5:12, LINO, REFER TO EXTERIOR ELEVATIONS AND <br />STRUCTURAL DRAWINGS <br />03 STONE VENEER <br />04 PREFABRICATED SOLID AWNING W/ INTEGRAL GUTTER. CONTRACTOR <br />TO COORDINATE WITH AND PROVIDE BLOCKING FOR ALL CONNECTIONS <br />AS REQUIRED PER MFR INSTALLER. SUBMIT SHOP DRAWINGS FOR <br />ARCHITECT TO REVIEW AND COORDINATION OF WATER PENETRATION <br />DETAILS <br />05 42" HIGH GUARDRAIL, REFER TO ENLARGED PLANS FOR DETAILS 7/A8.12 <br />06 ELECTRICAL SERVICE / METER, REFER TO ELECTRICAL DRAWINGS <br />07 STANDPIPE / HOSE VALVE CONNECTION, REFER TO CONTRACTOR'S FIRE <br />PROTECTION DRAWINGS <br />08 2X6 WALL <br />09 REFER TO CIVIL DRAWINGS FOR DOWNSPOUT CONNECTIONS TO <br />UNDERGROUND STORM WATER SYSTEM. CONTRACTOR TO PROVIDE <br />CONCRETE SPLASH BLOCKS AT ALL LOCATIONS NOT TIED TO <br />UNDERGROUND STORM WATER SYSTEM <br />10 DOWNSPOUT TO TERMINATE AT SPLASHBLOCK <br />11 CONCRETE A/C PAD (4" THICK), SLOPE AWAY FROM BUILDING, REFER TO <br />SITE PLAN FOR SCHEMATIC PAD LAYOUT AND TO MECHANICAL <br />DRAWINGS FOR A/C CONDENSER DETAILS, CONTRACTOR SHALL <br />COORDINATE FINAL PLACEMENT WITH CIVIL AND LANDSCAPE <br />LEGEND <br />WALL INDICATES SPECIFIC WALL TYPE <br />r FIRE EXTINGUISHER IN CABINET, REFER TO <br />FE GENERAL NOTES <br />INT. LOAD BRG. WALLS COORD. <br />W/ STRUCTURAL DRAWINGS <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarGhitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />AR0017018 <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />W <br />r PROJECT NO. 4097 <br />F <br />U <br />Z <br />Enlarged Plans, Unit <br />Finish Schedule & <br />Accessibility Details <br />at Kitchen <br />3/4" = 1'-0" <br />Enlarged Floor Plan <br />at Fourth Floor <br />3/8" = 1'-0" <br />Enlar <br />at First Floor <br />ed Floor Plan <br />3/8" = 1'-0" <br />A5.81 <br />
The URL can be used to link to this page
Your browser does not support the video tag.