Laserfiche WebLink
L <br />-r <br />1 <br />ii <br />5/4X6 <br />08 <br />07 5/4X4 <br />07 5/4X6 <br />08 <br />15 <br />O7 5/4X6 <br />07 5/4X4 <br />06 <br />07 5/4X6 <br />15 <br />O <br />Foam Band Detail <br />SHEET NOTES <br />A REFER TO SHEET A1.03 FOR GENERAL NOTES <br />B REFER TO SHEET A1.04 AND A1.05 FOR CONSTRUCTION ASSEMBLIES <br />C REFER TO SHEETS A5.61 THRU A5.69 FOR UNIT PLANS <br />D REFER TO SHEETS A9.11 AND A9.21 FOR DOOR, WINDOW AND <br />STOREFRONT SCHEDULES <br />E ALL ROOF SLOPES TO BE 5:12, LINO, REFER TO ROOF PLANS FOR OTHER <br />INFORMATION RELATED TO THE ROOF, REFER TO CIVIL DRAWINGS FOR <br />DOWNSPOUT CONNECTIONS TO UNDERGROUND STORM WATER SYSTEM <br />F ALL FIBER CEMENT TRIM TO BE SMOOTH TEXTURE, ALL HORIZONTAL LAP <br />SIDING TO BE WOOD GRAIN TEXTURE <br />3112" G ALL CEMENT PLASTER TRIM TO BE SAND TEXTURE, ALL OTHER CEMENT <br />PLASTER TO BE BRUSH FINISH TEXTURE <br />H ALL EXTERIOR TRIM BANDS, FINISHES, AND COLORS TRANSITIONS TO <br />RETURN TO INTERIOR CORNERS, COLUMN TRIMS, FLASHING, ETC. TO BE <br />CONTINUOUS AROUND ALL SIDES OF THE COLUMN / PILASTER, REFER <br />TO SECTIONS FOR FLASHING DETAILS, ALL EXTERIOR COLORS TO BE <br />_ SELECTED BY OWNER, LINO <br />r- <br />J CONTRACTOR TO COORDINATE ALL EXTERIOR BUILDING LIGHTING AND <br />SIGNAGE WITH ELECTRICAL DRAWINGS AND LOCAL REQUIREMENTS, <br />p <br />REFER TO ELECTRICAL DRAWINGS FOR DETAILS <br />K CONTRACTOR TO INSTALL ALL HANDRAILS AND GUARDRAILS WITH SOLID <br />WOOD BLOCKING AND SHALL BE MOUNTED ON FIBER CEMENT BLOCKING <br />FOR FIBER CEMENT SIDING APPLICATIONS, HANDRAILS AND GUARDS <br />O SHALL MEET THE STRUCTURAL REQUIREMENTS AS NOTED IN <br />SPECIFICATION SECTION 055213 <br />L CONTROL JOINTS TO BE INSTALLED AS INDICATED IN THE ELEVATIONS, <br />PER SPECIFICATION SECTION 092400, PER ASTM C 1063 AND IN <br />MANUFACTURER RECOMMENDED LOCATIONS, INCLUDING TOP OF FINISH <br />FLOOR AND AT SUBSTRATE CHANGES <br />0 KEYNOTES <br />01 ARCHITECTURAL ROOF SHINGLE SYSTEM PER ASSEMBLY, COLOR TO BE <br />SELECTED BY OWNER <br />02 LOW ROOF WITH 5:12 SLOPE, LINO <br />03 TYPICAL FASCIA TRIM: 5/4 X 8 FIBER CEMENT FASCIA BOARD OVER 2X8 <br />WOOD SUB FASCIA W/ METAL DRIP EDGE AT ROOF PERIMETER. <br />04 ALUMINUM GUTTERS AND DOWNSPOUTS, COORDINATE DOWNSPOUT <br />LOCATIONS WITH THE ROOF PLANS AND SITE CONDITIONS, COLOR TO BE <br />SELECTED BY OWNER <br />05 DOWNSPOUTS OVER LOW ROOFS SHALL DISCHARGE IN THE DIRECTION <br />OF SLOPE <br />06 FIBER CEMENT LAP SIDING PER ASSEMBLY, 6" REVEAL <br />5AX6 07 FIBER CEMENT TRIM, SIZE AS INDICATED <br />08 FIBER CEMENT PANEL PER ASSEMBLY, WHERE INDICATED COVER AND <br />SEAL SEAM WITH BATTENS, WHERE NOT INDICATED PROVIDE FLASHING <br />5/4X4 PER MANUFACTURER <br />09 MANUFACTURED THIN STONE VENEER PER ASSEMBLY, COLOR <br />SELECTED BY OWNER <br />10 HARD COAT FOAM TRIM BAND WITH SMOOTH FINISH, REFER TO DETAIL <br />5/4X6 4/A6.61 <br />11 42" HIGH ALUMINUM GUARDRAIL WITH VERTICAL PICKETS SPACED SUCH <br />THAT A 4 INCH SPHERE CAN NOT PASS THROUGH, ALL ENDS ATTACHED <br />TO WALL, REFER TO SPECIFICATION SECTION 055213, COLOR SELECTED <br />5/4X4 BY OWNER, CONTRACTOR TO SUBMIT SIGNED & SEALED SHOP <br />DRAWINGS FOR REVIEW <br />12 PREFABRICATED POWDER COATED ALUMINUM AWNING WITH INTEGRAL <br />GUTTER AND ROD TIE -BACKS, CONTRACTOR TO COORDINATE AND <br />PROVIDE BLOCKING FOR ALL CONNECTIONS, REFER TO DETAIL 11/A7.22, <br />COLOR SELECTED BY OWNER, SUBMIT SHOP DRAWINGS FOR <br />ARCHITECTURAL REVIEW AND COORDINATION OF WATER PENETRATION <br />DETAIL <br />13 THRU-WALL SCUPPER, REFER TO SECTION DETAILS <br />5AX6 14 OVERFLOW DRAIN OUTLET NOZZLE, REFER TO PLUMBING DRAWINGS <br />15 DOORS, WINDOWS, AND STOREFRONTS PER SCHEDULES <br />16 EXHAUST VENT CAP, EXHAUST DISCHARGE SHALL TERMINATE NOT LESS <br />THAN 3 FEET IN ANY DIRECTION FROM OPENINGS (E.G, OPERABLE <br />WINDOWS AND DOORS) INTO THE BUILDING, FRESH AIR INTAKES SHALL <br />BE LOCATED 10 FEET AWAY FROM EXHAUST VENTS, CONTRACTOR TO <br />COORDINATE <br />5AX4 <br />5/4X6 <br />5/4X6 <br />5/4X4 <br />5/4X6 <br />5/4X6 <br />5/4X4 <br />17 BUILDING SIGNAGE TO BE DESIGNED BY OTHERS, COORDINATE <br />ELECTRICAL REQUIREMENTS WITH SIGNAGE VENDOR / OWNER, PROVIDE <br />SHEATHING AS REQUIRED BY SIGNAGE VENDOR AND CONFIRM EXACT <br />LOCATION WITH OWNER, VENDOR AND AHJ <br />18 ELEVATOR HOISTWAY VENT, REFER TO MECHANICAL DRAWINGS <br />19 EXHAUST VENT, REFER TO MECHANICAL DRAWINGS <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />09/16/2022 <br />Karen V McIntyre <br />AR0017018 <br />SET DISTRIBUTIONS: <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Apartments - <br />Enlarged Exterior <br />Elevations & Details <br />Enlarged Elevation <br />3/8" = 1'-0" <br />Enlarged. Elevation � Enlarged Elevation <br />3/8" = 1'-0" <br />3/8" = 1'-0" <br />A6.61 <br />