Laserfiche WebLink
e <br />N <br />N <br />O <br />N <br />I <br />N <br />O <br />UNIT A2 <br />Typical Sheet Notes <br />Floor & Roof Framing Plans <br />A. SEE SHEET "S3.01" FOR GENERAL STRUCTURAL NOTES, TYP. <br />B. SEE SHEET "S4.00.1" FOR WOOD BEAM/HEADER SCHEDULE, TRUSS FRAMING DESIGN <br />CRITERIA, & TYPICAL BUILT-UP WOOD STUD COLUMN DETAILS, TYP. <br />C. SEE SHEET "S4.04.1" FOR FLORIDA BUILDING CODE COMPONENT & CLADDING DESIGN <br />WIND PRESSURE TABLE, TYP. <br />D. EXTERIOR WALL SHEATHING TO BE 716" CDX PLYWOOD or O.S.B. FASTENED TO WOOD <br />FRAMING w/ 8d RING SHANK NAILS @ 6" O.C. ALONG PANEL EDGES & 12" O.C. IN <br />FIELD, TYP. (U.N.O.) <br />G. "SW-#" INDICATES WOOD STUD SHEAR WALL. REFER TO SHEET "S4.04.2" FOR 4-STORY <br />SHEAR WALL SCHEDULE & DETAILS, TYP. <br />H. REFER TO SHEETS "S4.04.3" TO "S4.04.4" FOR TYPICAL WOOD WALL FRAMING <br />ELEVATIONS w/ STRAPPING & ANCHORAGES, TYP. <br />I. GIRDER TRUSS ACROSS CORRIDOR TO BE DESIGNED TO ALLOW MECHANICAL DUCT <br />TO PASS THROUGH. COORDINATE w/ M.E.P. DRAWINGS, TYP. <br />J. ALL MASONRY WALLS TO BE 8" CMU (f m = 1,500 PSI) w/ 9 GA. HORIZ. LADDER REINF. <br />@ 16" O.C. & HAVE #5 VERTICAL BAR @ 32" O.C. IN SOLID GROUTED CELL, TYP. <br />PROVIDE 48 BAR O LAP w/ VERTICAL REINF. ABOVE BOND BEAM WHERE REQ'D., TYP. <br />SEE SHEET "S3.05" FOR TYPICAL MASONRY DETAILS <br />CONTRACTOR NOTE: <br />THRESHOLD BUILDING INSPECTIONS ARE CONSIDERED ADDITIONAL INSPECTIONS TO THE <br />INSPECTIONS REQUIRED ON THE BUILDING PERMIT. THE CONTRACTOR SHALL BE <br />REQUIRED TO SCHEDULE REGULAR INSPECTIONS THROUGH THE LOCAL <br />BUILDING INSPECTION DEPARTMENT. SEESHEET S3.01A FORTHRESHOLD <br />INSPECTION PLAN. <br />® Key Notes <br />4th Floor Framing Plan (4 Story Building) <br />1. FIN. 4th FLOOR ELEVATION = 36'-11%", TYP. (U.N.O.) <br />10. INTERIOR LOAD -BEARING STUD WALLS @ 4th FLOOR: <br />FLOOR TRUSS BEARING ELEVATION = 33'-87/", TYP. (U.N.O.) <br />PROVIDE 2x4 VERTICAL STUDS SPACED @ 16" O.C., TYP. PROVIDE CONT. DBL. 2x4 TOP <br />PLATE & CONT. 2x4 P.T. PLATE FASTENED TO FLOOR FRAMING w/ 0.148"Ox3Y4" NAILS <br />2. TRUSS SHOP DRAWINGS: PROVIDE SHOP DRAWINGS SHOWING TRUSS LAYOUT, <br />@ 12" O.C., TYP. <br />PROFILES, CONNECTIONS, & LOAD DIAGRAMS FOR FLOOR TRUSS SYSTEM SIGNED & <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. <br />11. LOAD -BEARING CMU WALLS @ 4th FLOOR ELEVATOR: PROVIDE 8" CMU STACKED IN <br />RUNNING BOND w/ #5 VERT. REINF. IN SOLID GROUTED CELLS @ CORNERS, ENDS, <br />3. FLOOR TRUSSES: PROVIDE ENGINEERED, PRE -FABRICATED 2x WOOD TRUSSES FOR <br />INTERSECTIONS, & SPACED @ 32" O.C. (MAX.), TYP. <br />LOADS, SPANS, & CONDITIONS SHOWN. SPACE TRUSSES @ 24" O.C. MAX. & AS <br />REQUIRED BY TRUSS MANUF. PROVIDE ALL REQUIRED INFILL FRAMING, BLOCKING, & <br />12. INTERIOR NON -BEARING STUD WALLS: <br />BRACING AS REQ'D. TO FRAME ENTIRE FLOOR -CEILING ASSEMBLY. COORDINATE <br />PROVIDE 2x4 or 2x6 VERTICAL STUDS @ 16" O.C. w/ CONT. 2x TOP PLATE & CONT. 2x <br />TRUSS SPACING w/ MECHANICAL FIXTURES & EQUIPMENT LOCATIONS. <br />BOTTOM PLATE PER ARCH. DWGS, TYP. <br />4. TYPICAL UNIT FLOOR FRAMING: 20" DEEP ENGINEERED WOOD TRUSSES SPACED @ <br />13. ALL STUD WALL SILL PLATES & OTHER WOOD MEMBERS IN CONTACT w/ CONCRETE <br />24" O.C. (MAX.) COORD. LOCATIONS w/ ARCH. & M.E.P. DRAWINGS, TYP. <br />OR MASONRY SHALL BE PRESSURE TREATED, TYP. <br />5. TYPICAL UNIT FLOOR DECKING: PROVIDE GYP-CRETE TOPPING PER ARCH. DWGS. <br />OVER Y4" TONGUE & GROOVE, APA SPAN RATED, CODE CERTIFIED O.S.B. DECKING. <br />GLUE & NAIL TO TRUSS TOP CHORDS w/ 8d RING SHANK NAILS @ 6" O.C. ALONG <br />PANEL EDGES & 12" O.C. INFIELD, TYP. <br />6. BALCONY FLOOR FRAMING: 18" DEEP (MAX.) ENGINEERED WOOD TRUSSES w/ <br />SLOPED TOP CHORD SPACED @ 24" O.C. (MAX.) w/ SLOPED TOP CHORDS AS REQ'D. <br />COORD. LOCATIONS w/ ARCH. & M.E.P. DWGS., TYP. <br />7. BALCONY FLOOR DECKING: PROVIDE 1%" MIN. (3" MAX.) LIGHTWEIGHT CONCRETE <br />TOPPING (115 PCF MAX.) PER ARCH. DWGS. OVER Y4" TONGUE & GROOVE, APA SPAN <br />RATED, CODE CERTIFIED PLYWOOD OR O.S.B. DECKING. GLUE & NAIL SHEATHING TO <br />TRUSS TOP CHORDS w/ 8d RING SHANK NAILS @ 6" O.C. ALONG PANEL EDGES & 12" <br />O.C. INFIELD, TYP. <br />8. FLOOR TRUSS DRAFTSTOP: PROVIDE DRAFTSTOPPING AS SPECIFIED ON ARCH. DWGS. <br />IN FLOOR TRUSS ABOVE TENANT SEPARATION WALLS, BREEZEWAY WALLS & <br />CORRIDOR WALLS, TYP. <br />9. EXTERIOR LOAD -BEARING STUD WALLS @ 4th FLOOR: <br />PROVIDE 2x6 VERTICAL STUDS @ 16" O.C. w/ 2x6 SOLID BLOCKING @ 5-0" (MAX.) <br />PROVIDE CONT. DBL. 2x6 TOP PLATE & CONT. 2x6 BOTTOM PLATE FASTENED TO <br />FLOOR FRAMING w/ 0.148"00%4" NAILS @ 12" O.C., TYP. <br />14. SHEARWALLS & TRUSSES: WHEN SHEARWALLS ARE PARALLEL w/ ROOF OR FLOOR <br />TRUSSES & NORMALLY SPACED TRUSSES DO NOT ALIGN w/ SHEARWALLS, PROVIDE <br />FULL HEIGHT INFILL TRUSSES OVER EACH SHEARWALL w/ VERTICAL MEMBERS @ 16" <br />O.C. MAX. ANCHOR TRUSSES TO SHEARWALLS & DECK SHEATHING AS NOTED ON <br />SHEARWALL SCHEDULES. ADJUST HEIGHT & SHAPE OF TRUSSES AS REQ'D. TO MATCH <br />DEFLECTION OF SPANNING TRUSSES. <br />15. STAIR FRAMING: PRE-ENGINEERED STEEL STAIRS w/ PRE -CAST CONCRETE TREADS. SEE <br />ARCH. DWGS. FOR REQUIRED LAYOUT & DIMENSIONS, TYP. SUBMIT COMPLETE SHOP <br />DRAWINGS & CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER <br />REGISTERED IN THE STATE OF FLORIDA TO ARCH. & ENGINEER FOR REVIEW & <br />APPROVAL. <br />16. GIRDER TRUSS SUPPORT: PROVIDE (4) 2x MULTI -STUD WOOD POST FASTENED w/ 10d <br />NAILS @ 12" O.C. STAGGERED EACH PLY UNDER BEARING POINTS OF ALL <br />PRE-ENGINEERED GIRDER TRUSSES TO FOUNDATION w/ CRUSH BLOCKS IN FLOOR <br />TRUSSES, TYP. (U.NO.) <br />C4NIT B3 UNIT Al C*�� C4� C*fAl C4NIT 63 <br />I l Building Type II -Fourth Floor Framing Plan <br />S3.24) <br />3.24) SCALE: %" = 1'-0" <br />UNIT Bl <br />UNIT A2 <br />ro <br />ro <br />b <br />0 <br />IL <br />v <br />L <br />L <br />,3 <br />v <br />U <br />C <br />ro <br />L <br />0 <br />U <br />U <br />ro <br />0 <br />L <br />ro <br />ro <br />U <br />0 <br />OJ <br />r <br />.0 <br />v <br />C <br />L <br />Iv <br />kA <br />0 <br />bQ <br />,II <br />.lJ <br />_0 <br />.0 <br />ro <br />u <br />n. <br />a <br />ro <br />N <br />r <br />+r <br />r <br />a <br />0 <br />U <br />+j <br />U <br />N <br />0 <br />L <br />a <br />L <br />d-+ <br />L <br />C <br />0 <br />'+1 <br />ro <br />U <br />4. <br />U <br />OJ <br />a <br />ro <br />1A <br />ro <br />n. <br />Q) <br />s <br />+­4 <br />v <br />ao <br />3 <br />0 <br />C <br />V <br />, <br />L <br />Iv <br />C <br />C <br />W <br />0 <br />0 <br />r <br />+-j <br />4- <br />0 <br />Q) <br />.0 <br />Q) <br />3 <br />Q <br />r <br />m <br />WFORUME <br />0 <br />a- ARCHITECTURE & <br />LO <br />z INTERIOR DESIGN, INC. <br />z PLANNEVG I ARCFIT =P2 I AJTMM DESM <br />U) <br />w <br />0 <br />a <br />W 237 S. Westmonte Drive, Suite 220 <br />z Altamonte Springs, FL 32714 <br />407.830.1400 <br />0 <br />N <br />w <br />z <br />0 <br />i- <br />U <br />7 <br />0 <br />O <br />K <br />d <br />w <br />K <br />z <br />Q <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />City of Zephyrhills, FL <br />eT' <br />�m <br />2965 WEST STATE ROAD 434, SUITE 100 ■ LONGWOOD, FL 32779 <br />TEL 407/682-2086 ■ FAX 407/682.2386 <br />WWW.SCD-ENG.COM <br />���®p��80pppgQO <br />C_ <br />TGa1T OF �U 0 <br />ONAL <br />aa0000aOO <br />Robert C. Scroggins, P.E. <br />FL Registration No, 56158 <br />This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date <br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not <br />considered signed and sealed and the signature must be verified on any electronic copies. <br />SET DISTRIBUTIONS: <br />SHEET REVISIONS: <br />EDITED BY: RCS, TLW <br />SC&D PROJECT NO. 21-020 <br />FORUM PROJECT NO. 4097 <br />U <br />Z <br />Building Type <br />Fourth Floor <br />0 <br />it <br />w Framing Plan <br />z <br />00 <br />w <br />D <br />F- <br />U <br />W <br />F <br />T <br />U <br />S3.24 <br />12� <br />W <br />