e
<br />N
<br />N
<br />O
<br />N
<br />I
<br />N
<br />O
<br />UNIT A2
<br />Typical Sheet Notes
<br />Floor & Roof Framing Plans
<br />A. SEE SHEET "S3.01" FOR GENERAL STRUCTURAL NOTES, TYP.
<br />B. SEE SHEET "S4.00.1" FOR WOOD BEAM/HEADER SCHEDULE, TRUSS FRAMING DESIGN
<br />CRITERIA, & TYPICAL BUILT-UP WOOD STUD COLUMN DETAILS, TYP.
<br />C. SEE SHEET "S4.04.1" FOR FLORIDA BUILDING CODE COMPONENT & CLADDING DESIGN
<br />WIND PRESSURE TABLE, TYP.
<br />D. EXTERIOR WALL SHEATHING TO BE 716" CDX PLYWOOD or O.S.B. FASTENED TO WOOD
<br />FRAMING w/ 8d RING SHANK NAILS @ 6" O.C. ALONG PANEL EDGES & 12" O.C. IN
<br />FIELD, TYP. (U.N.O.)
<br />G. "SW-#" INDICATES WOOD STUD SHEAR WALL. REFER TO SHEET "S4.04.2" FOR 4-STORY
<br />SHEAR WALL SCHEDULE & DETAILS, TYP.
<br />H. REFER TO SHEETS "S4.04.3" TO "S4.04.4" FOR TYPICAL WOOD WALL FRAMING
<br />ELEVATIONS w/ STRAPPING & ANCHORAGES, TYP.
<br />I. GIRDER TRUSS ACROSS CORRIDOR TO BE DESIGNED TO ALLOW MECHANICAL DUCT
<br />TO PASS THROUGH. COORDINATE w/ M.E.P. DRAWINGS, TYP.
<br />J. ALL MASONRY WALLS TO BE 8" CMU (f m = 1,500 PSI) w/ 9 GA. HORIZ. LADDER REINF.
<br />@ 16" O.C. & HAVE #5 VERTICAL BAR @ 32" O.C. IN SOLID GROUTED CELL, TYP.
<br />PROVIDE 48 BAR O LAP w/ VERTICAL REINF. ABOVE BOND BEAM WHERE REQ'D., TYP.
<br />SEE SHEET "S3.05" FOR TYPICAL MASONRY DETAILS
<br />CONTRACTOR NOTE:
<br />THRESHOLD BUILDING INSPECTIONS ARE CONSIDERED ADDITIONAL INSPECTIONS TO THE
<br />INSPECTIONS REQUIRED ON THE BUILDING PERMIT. THE CONTRACTOR SHALL BE
<br />REQUIRED TO SCHEDULE REGULAR INSPECTIONS THROUGH THE LOCAL
<br />BUILDING INSPECTION DEPARTMENT. SEESHEET S3.01A FORTHRESHOLD
<br />INSPECTION PLAN.
<br />® Key Notes
<br />4th Floor Framing Plan (4 Story Building)
<br />1. FIN. 4th FLOOR ELEVATION = 36'-11%", TYP. (U.N.O.)
<br />10. INTERIOR LOAD -BEARING STUD WALLS @ 4th FLOOR:
<br />FLOOR TRUSS BEARING ELEVATION = 33'-87/", TYP. (U.N.O.)
<br />PROVIDE 2x4 VERTICAL STUDS SPACED @ 16" O.C., TYP. PROVIDE CONT. DBL. 2x4 TOP
<br />PLATE & CONT. 2x4 P.T. PLATE FASTENED TO FLOOR FRAMING w/ 0.148"Ox3Y4" NAILS
<br />2. TRUSS SHOP DRAWINGS: PROVIDE SHOP DRAWINGS SHOWING TRUSS LAYOUT,
<br />@ 12" O.C., TYP.
<br />PROFILES, CONNECTIONS, & LOAD DIAGRAMS FOR FLOOR TRUSS SYSTEM SIGNED &
<br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA.
<br />11. LOAD -BEARING CMU WALLS @ 4th FLOOR ELEVATOR: PROVIDE 8" CMU STACKED IN
<br />RUNNING BOND w/ #5 VERT. REINF. IN SOLID GROUTED CELLS @ CORNERS, ENDS,
<br />3. FLOOR TRUSSES: PROVIDE ENGINEERED, PRE -FABRICATED 2x WOOD TRUSSES FOR
<br />INTERSECTIONS, & SPACED @ 32" O.C. (MAX.), TYP.
<br />LOADS, SPANS, & CONDITIONS SHOWN. SPACE TRUSSES @ 24" O.C. MAX. & AS
<br />REQUIRED BY TRUSS MANUF. PROVIDE ALL REQUIRED INFILL FRAMING, BLOCKING, &
<br />12. INTERIOR NON -BEARING STUD WALLS:
<br />BRACING AS REQ'D. TO FRAME ENTIRE FLOOR -CEILING ASSEMBLY. COORDINATE
<br />PROVIDE 2x4 or 2x6 VERTICAL STUDS @ 16" O.C. w/ CONT. 2x TOP PLATE & CONT. 2x
<br />TRUSS SPACING w/ MECHANICAL FIXTURES & EQUIPMENT LOCATIONS.
<br />BOTTOM PLATE PER ARCH. DWGS, TYP.
<br />4. TYPICAL UNIT FLOOR FRAMING: 20" DEEP ENGINEERED WOOD TRUSSES SPACED @
<br />13. ALL STUD WALL SILL PLATES & OTHER WOOD MEMBERS IN CONTACT w/ CONCRETE
<br />24" O.C. (MAX.) COORD. LOCATIONS w/ ARCH. & M.E.P. DRAWINGS, TYP.
<br />OR MASONRY SHALL BE PRESSURE TREATED, TYP.
<br />5. TYPICAL UNIT FLOOR DECKING: PROVIDE GYP-CRETE TOPPING PER ARCH. DWGS.
<br />OVER Y4" TONGUE & GROOVE, APA SPAN RATED, CODE CERTIFIED O.S.B. DECKING.
<br />GLUE & NAIL TO TRUSS TOP CHORDS w/ 8d RING SHANK NAILS @ 6" O.C. ALONG
<br />PANEL EDGES & 12" O.C. INFIELD, TYP.
<br />6. BALCONY FLOOR FRAMING: 18" DEEP (MAX.) ENGINEERED WOOD TRUSSES w/
<br />SLOPED TOP CHORD SPACED @ 24" O.C. (MAX.) w/ SLOPED TOP CHORDS AS REQ'D.
<br />COORD. LOCATIONS w/ ARCH. & M.E.P. DWGS., TYP.
<br />7. BALCONY FLOOR DECKING: PROVIDE 1%" MIN. (3" MAX.) LIGHTWEIGHT CONCRETE
<br />TOPPING (115 PCF MAX.) PER ARCH. DWGS. OVER Y4" TONGUE & GROOVE, APA SPAN
<br />RATED, CODE CERTIFIED PLYWOOD OR O.S.B. DECKING. GLUE & NAIL SHEATHING TO
<br />TRUSS TOP CHORDS w/ 8d RING SHANK NAILS @ 6" O.C. ALONG PANEL EDGES & 12"
<br />O.C. INFIELD, TYP.
<br />8. FLOOR TRUSS DRAFTSTOP: PROVIDE DRAFTSTOPPING AS SPECIFIED ON ARCH. DWGS.
<br />IN FLOOR TRUSS ABOVE TENANT SEPARATION WALLS, BREEZEWAY WALLS &
<br />CORRIDOR WALLS, TYP.
<br />9. EXTERIOR LOAD -BEARING STUD WALLS @ 4th FLOOR:
<br />PROVIDE 2x6 VERTICAL STUDS @ 16" O.C. w/ 2x6 SOLID BLOCKING @ 5-0" (MAX.)
<br />PROVIDE CONT. DBL. 2x6 TOP PLATE & CONT. 2x6 BOTTOM PLATE FASTENED TO
<br />FLOOR FRAMING w/ 0.148"00%4" NAILS @ 12" O.C., TYP.
<br />14. SHEARWALLS & TRUSSES: WHEN SHEARWALLS ARE PARALLEL w/ ROOF OR FLOOR
<br />TRUSSES & NORMALLY SPACED TRUSSES DO NOT ALIGN w/ SHEARWALLS, PROVIDE
<br />FULL HEIGHT INFILL TRUSSES OVER EACH SHEARWALL w/ VERTICAL MEMBERS @ 16"
<br />O.C. MAX. ANCHOR TRUSSES TO SHEARWALLS & DECK SHEATHING AS NOTED ON
<br />SHEARWALL SCHEDULES. ADJUST HEIGHT & SHAPE OF TRUSSES AS REQ'D. TO MATCH
<br />DEFLECTION OF SPANNING TRUSSES.
<br />15. STAIR FRAMING: PRE-ENGINEERED STEEL STAIRS w/ PRE -CAST CONCRETE TREADS. SEE
<br />ARCH. DWGS. FOR REQUIRED LAYOUT & DIMENSIONS, TYP. SUBMIT COMPLETE SHOP
<br />DRAWINGS & CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER
<br />REGISTERED IN THE STATE OF FLORIDA TO ARCH. & ENGINEER FOR REVIEW &
<br />APPROVAL.
<br />16. GIRDER TRUSS SUPPORT: PROVIDE (4) 2x MULTI -STUD WOOD POST FASTENED w/ 10d
<br />NAILS @ 12" O.C. STAGGERED EACH PLY UNDER BEARING POINTS OF ALL
<br />PRE-ENGINEERED GIRDER TRUSSES TO FOUNDATION w/ CRUSH BLOCKS IN FLOOR
<br />TRUSSES, TYP. (U.NO.)
<br />C4NIT B3 UNIT Al C*�� C4� C*fAl C4NIT 63
<br />I l Building Type II -Fourth Floor Framing Plan
<br />S3.24)
<br />3.24) SCALE: %" = 1'-0"
<br />UNIT Bl
<br />UNIT A2
<br />ro
<br />ro
<br />b
<br />0
<br />IL
<br />v
<br />L
<br />L
<br />,3
<br />v
<br />U
<br />C
<br />ro
<br />L
<br />0
<br />U
<br />U
<br />ro
<br />0
<br />L
<br />ro
<br />ro
<br />U
<br />0
<br />OJ
<br />r
<br />.0
<br />v
<br />C
<br />L
<br />Iv
<br />kA
<br />0
<br />bQ
<br />,II
<br />.lJ
<br />_0
<br />.0
<br />ro
<br />u
<br />n.
<br />a
<br />ro
<br />N
<br />r
<br />+r
<br />r
<br />a
<br />0
<br />U
<br />+j
<br />U
<br />N
<br />0
<br />L
<br />a
<br />L
<br />d-+
<br />L
<br />C
<br />0
<br />'+1
<br />ro
<br />U
<br />4.
<br />U
<br />OJ
<br />a
<br />ro
<br />1A
<br />ro
<br />n.
<br />Q)
<br />s
<br />+4
<br />v
<br />ao
<br />3
<br />0
<br />C
<br />V
<br />,
<br />L
<br />Iv
<br />C
<br />C
<br />W
<br />0
<br />0
<br />r
<br />+-j
<br />4-
<br />0
<br />Q)
<br />.0
<br />Q)
<br />3
<br />Q
<br />r
<br />m
<br />WFORUME
<br />0
<br />a- ARCHITECTURE &
<br />LO
<br />z INTERIOR DESIGN, INC.
<br />z PLANNEVG I ARCFIT =P2 I AJTMM DESM
<br />U)
<br />w
<br />0
<br />a
<br />W 237 S. Westmonte Drive, Suite 220
<br />z Altamonte Springs, FL 32714
<br />407.830.1400
<br />0
<br />N
<br />w
<br />z
<br />0
<br />i-
<br />U
<br />7
<br />0
<br />O
<br />K
<br />d
<br />w
<br />K
<br />z
<br />Q
<br />www.forumarchitecture.com
<br />Zephyr
<br />Commons
<br />City of Zephyrhills, FL
<br />eT'
<br />�m
<br />2965 WEST STATE ROAD 434, SUITE 100 ■ LONGWOOD, FL 32779
<br />TEL 407/682-2086 ■ FAX 407/682.2386
<br />WWW.SCD-ENG.COM
<br />���®p��80pppgQO
<br />C_
<br />TGa1T OF �U 0
<br />ONAL
<br />aa0000aOO
<br />Robert C. Scroggins, P.E.
<br />FL Registration No, 56158
<br />This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date
<br />and/or Time Stamp shown using a digital signature. Printed copies of this document are not
<br />considered signed and sealed and the signature must be verified on any electronic copies.
<br />SET DISTRIBUTIONS:
<br />SHEET REVISIONS:
<br />EDITED BY: RCS, TLW
<br />SC&D PROJECT NO. 21-020
<br />FORUM PROJECT NO. 4097
<br />U
<br />Z
<br />Building Type
<br />Fourth Floor
<br />0
<br />it
<br />w Framing Plan
<br />z
<br />00
<br />w
<br />D
<br />F-
<br />U
<br />W
<br />F
<br />T
<br />U
<br />S3.24
<br />12�
<br />W
<br />
|