Laserfiche WebLink
E ASSEMBLIES <br />PAINTING GENERAL DATA <br />11 <br />a) <br />CU <br />U) <br />TYPICAL AT EXTERIOR WALLS AT FINISHED INTERIOR SPACE <br />EXTERIOR FINISH PER ELEVATIONS: <br />A. 5/8" MIN CEMENT PLASTER FINISH, DIRECTLY <br />APPLIED <br />NONRATED <br />I <br />I <br />I <br />I <br />I <br />I <br />CMU WALL PER STRUCTURAL DRAWINGS, 8" (MIN) UNO <br />PT 2x WOOD FURRING AT 24" OC MAX <br />I <br />i <br />CONTINUOUS PERFORATED RADIANT FOIL INSULATION <br />I <br />I <br />I <br />(1) LAYER 1/2" GYPSUM BOARD <br />FINT <br />I <br />I <br />I <br />EXT j <br />TYPICAL AT EXTERIOR WALLS AT UNCONDITIONED / UNFINISHED SPACE <br />C-16 <br />I <br />-- <br />EXTERIOR FINISH PER ELEVATIONS: <br />A. 5/8" MIN CEMENT PLASTER FINISH, DIRECTLY APPLIED <br />NON RATED <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />CMU WALL PER STRUCTURAL DRAWINGS, 8" (MIN) UNO <br />I <br />I <br />PAINT FINISH AT EXPOSED SURFACES <br />I <br />I <br />EXT i <br />INT <br />TYPICAL AT PITCHED ROOF <br />RW-2 <br />ROOFING PER PLANS, ELEVATIONS AND DETAILS: <br />A. ARCHITECTURAL FIBERGLASS ASPHALT SHINGLES <br />NON -RATED <br />� <br />- -'� ROOF UNDERLAYMENT PER SPECIFICATIONS AND ROOFING <br />SYSTEM REQUIREMENTS <br />(1) LAYER 1/2"-5/8" (NOMINAL) WOOD STRUCTURAL PANEL <br />ROOF SHEATHING PER STRUCTURAL DRAWINGS <br />WOOD TRUSS AT 24" OC MAX PER STRUCTURAL DRAWINGS <br />WITH SLOPE PER ROOF PLAN(S) <br />BLOWN OR BATT INSULATION OVER CONDITIONED SPACES <br />(1) LAYER 1/2" MIN. GYPSUM BOARD (EXTERIOR GRADE AT <br />UNCONDITIONED SPACES) <br />UNO BY OWNER / INTERIOR DESIGNER <br />DOOR SCHEDULE - AMENITIES BUILDING <br />O <br />DOOR <br />FRAME <br />RATING <br />HARDWARE <br />REMARKS <br />DESC. <br />TYPE <br />SIZE <br />MATL. <br />MARK <br />W <br />H <br />MATL. <br />1 <br />EXT <br />2P <br />3'4" <br />6'-8" <br />MTL <br />MTL <br />-- <br />1 <br />-- <br />2 <br />EXT <br />OH <br />9-0" <br />T-0" <br />MTL <br />MTL <br />m <br />2 <br />- - <br />DOOR TYPES <br />2P <br />2-PANEL DOOR <br />DOOR HARDWARE <br />rMENIMI i <br />I ININIi <br />OH <br />OVERHEAD GARAGE DOOR <br />1 - DEADBOLT - KEYED OUTSIDE, BLIND INSIDE <br />-PASSAGE LATCH <br />- (1 1/2) PAIR 4"x4" SPRING HINGES <br />- BOTTOM SWEEP & DOOR SEAL <br />2 -MANUFACTURER'S STANDARD HARDWARE <br />-PROVIDE ELECTRIC GARAGE DOOR OPENER <br />-PROVIDE GARAGE DOOR OPENER KEYPAD CONTROL ON EXTERIOR <br />JAMB <br />-PROVIDE GARAGE DOOR OPENER PUSHBUTTON CONTROL ON INTERIOR <br />JAMB <br />-PROVIDE MANUAL EXTERNAL EMERGENCY KEY RELEASE <br />1. REFER TO, AND COORDINATE WITH, INTERIOR FINISH SCHEDULE AND SEPARATE DOCUMENTS PREPARED BY <br />INTERIOR DESIGNER AND/OR OWNER, WHEN APPLICABLE, FOR SPECIFIC PAINT SELECTIONS, COLORS, FINISH <br />TEXTURES, AND OTHER REQUIREMENTS. <br />2. ALL EXTERIOR VENTS AND EQUIPMENT THAT ARE VISIBLE ON EXTERIOR OF BUILDING SHALL BE PAINTED A <br />COLOR TO MATCH THE ADJACENT SURFACE, UNO. <br />3. ALL COLOR TRANSITIONS SHALL BE ON THE INSIDE CORNERS, UNLESS OTHERWISE SPECIFIED IN COLOR <br />STUDY ELEVATIONS. <br />4. CONTACT THE OWNER OR ARCHITECT IF THERE ARE ANY QUESTIONS PRIOR TO PAINTING. <br />5. PREPARATION AND APPLICATION OF PRIMER AND FINISH PAINT PRODUCTS SHALL BE DONE PER THE <br />MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />6. ALL GYPSUM BOARD FINISHED SURFACES IN CONDITIONED AND NON -CONDITIONED SPACES SHALL BE <br />PAINTED AS SPECIFIED, UNO. <br />CABINETS & COUNTERTOPS <br />1. VANITY BASE CABINETS SHALL BE 21" DEEP WITH 22" TOPS, UNO. REFER TO INTERIOR ELEVATIONS FOR <br />HEIGHTS. COUNTERTOP OVERHANG AT THE EXPOSED END OF THE VANITY CABINET SHALL NOT BE MORE <br />THAN 1". <br />2. KITCHEN BASE CABINETS TO BE 24" DEEP WITH 25" TOPS, UNO. UPPER CABINETS TO BE 12" DEEP. REFER TO <br />INTERIOR ELEVATIONS FOR HEIGHTS. <br />3. CONTRACTOR OR CABINET MANUFACTURER TO FIELD VERIFY FINISH TO FINISH DIMENSIONS PRIOR TO <br />FABRICATION OF CABINETS. <br />4. ALL EXPOSED FINISHED SURFACES SHALL MATCH THE COLOR AND FINISH OF THE ADJACENT FINISHED <br />SURFACE; INCLUDING EXPOSED CABINET ENDS SHALL MATCH CABINET FRONT. <br />5. ALL WALLS / PARTITIONS SUPPORTING WALL HUNG CABINETS SHALL HAVE FRAMING WITH 2 X 4 STUDS <br />AT 16" O.C. MAX. OR 2 X 6 STUDS AT 24" O.C. MAX., UNO. <br />E ABBREVIATION LEGEND <br />AC <br />Air Conditioned(er) <br />FPM <br />Feet Per Minute <br />PRE-ENG <br />Pre-engineered <br />AFF <br />Above Finish Floor <br />FR <br />Fire Rated <br />PSF <br />Pounds Per Square Foot <br />AHJ <br />Authority Having Jurisdiction <br />FRCP <br />Fiber Reinforced Cement <br />PSI <br />Pounds Per Square Inch <br />AHU <br />Air Handler Unit <br />Plaster <br />P-T <br />Post Tension <br />ALT <br />Alternate <br />FRP <br />Fiber Reinforced Panel <br />PT <br />Pressure Treated Wood <br />ALUM <br />Aluminum <br />FRT <br />Fire Retardant Treated <br />PTAC <br />Package Terminal AC <br />APT <br />Apartment <br />FT <br />Foot / Feet <br />PTD <br />Painted <br />BALC <br />Balcony <br />FTG <br />Footing <br />PVC <br />Poly Vinyl Chloride <br />BFF <br />Below Finish Floor <br />FND <br />Foundation <br />QT <br />Quarry Tile <br />BLDG <br />Building <br />FOB <br />Face of Beam <br />RAD <br />Radius <br />BLKG <br />Blocking <br />FOS <br />Face of Stud <br />RCP <br />Reflected Ceiling Plan <br />BM <br />Beam <br />GA <br />Gauge <br />REF <br />Reference <br />BR <br />Bedroom <br />GALV <br />Galvanized <br />REFRIG <br />Refrigerator <br />BRG <br />Bearing <br />GAR <br />Garage <br />REINF <br />Reinforce(ed/ing) <br />BRZWY <br />Breezeway <br />GC <br />General Contractor <br />REQD <br />Required <br />BTM <br />Bottom <br />GLS <br />Glass <br />RM <br />Room <br />CAB <br />Cabinet <br />GLZ <br />Glazing <br />RO <br />Rough Opening <br />CALC <br />Calculation <br />GYPBD <br />Gypsum Board <br />RS <br />Rough Sawn <br />CER <br />Ceramic <br />HC <br />Hollow Core <br />RSC <br />Rough Sawn Cedar <br />CFM <br />Cubic Feet Per Minute <br />HB <br />Hose Bibb <br />SAN <br />Sanitary <br />CFS <br />Clear Floor Space <br />HDR <br />Header <br />SC <br />Solid Core <br />CIP <br />Cast In Place <br />HDW <br />Hardware <br />SCH <br />Schedule <br />CJ <br />Control Joint <br />HORIZ <br />Horizontal <br />SEP <br />Separation <br />CL <br />Center Line <br />HR <br />Hour <br />SF <br />Square Feet <br />CLG <br />Ceiling <br />HT <br />Height <br />SGD <br />Sliding Glass Door <br />CLOS <br />Closet <br />HVAC <br />Heating, Venting & AC <br />SHT <br />Sheet <br />CLR <br />Clear <br />IBC <br />International Building Code <br />SHTG <br />Sheathing <br />CMU <br />Concrete Masonry Unit <br />ID <br />Interior Design <br />SIM <br />Similar <br />COL <br />Column <br />IN <br />Inch / Inches <br />SOG <br />Slab On Grade <br />CONC <br />Concrete <br />INST <br />Installation <br />SP <br />Spring Point <br />COND <br />Condenser / Condensate <br />INSUL <br />Insulation (ed) <br />SPEC <br />Specifications <br />CONT <br />Continuous <br />INT <br />Interior <br />SPF <br />Spruce -Pine -Fur <br />CORR <br />Corridor <br />JB <br />Junction Box <br />SQ <br />Square <br />CID <br />Cement Plaster <br />JST <br />Joist <br />SS <br />Stainless Steel <br />CPT <br />Carpet <br />JT <br />Joint <br />STC <br />Sound Transmission Class <br />CT <br />Ceramic Tile <br />KDAT <br />Kiln Dried After Treatment <br />STD <br />Standard <br />CW <br />Cold Water <br />KIT <br />Kitchen <br />STL <br />Steel <br />D <br />Dryer <br />LAM <br />Laminate <br />STO <br />Storage <br />DIA <br />Diameter <br />LAV <br />Lavatory <br />SW <br />Shear Wall <br />DIM <br />Dimension <br />LF <br />Linear Feet <br />SYM <br />Symmetrical <br />DN <br />Down <br />LIN <br />Linen <br />SYP <br />Southern Yellow Pine <br />DIN <br />Dining <br />LR <br />Living Room <br />T&B <br />Top & Bottom <br />DP <br />Deep <br />LT <br />Light <br />T&G <br />Tongue & Groove <br />DR <br />Door <br />MAX <br />Maximum <br />TB <br />Towel Bar <br />DS <br />Down Spout <br />MECH <br />Mechanical <br />TEMP <br />Tempered <br />DTL <br />Detail <br />MEM <br />Membrane <br />THK <br />Thick <br />DW <br />Dishwasher <br />MEP <br />Mechanical, Electrical, <br />TPD <br />Toilet Paper Dispenser <br />DWG <br />Drawing <br />Plumbing <br />TPH <br />Toilet Paper Holder <br />EA <br />Each <br />MFR <br />Manufacturer (ed) <br />T.O. <br />Top of <br />ELEC <br />Electric (al) <br />MIN <br />Minimum <br />TOS <br />Top of Slab <br />ELEV <br />Elevation <br />MIR <br />Mirror <br />TOFD <br />Top of Floor Deck <br />ENG <br />Engineer(ed) <br />MISC <br />Miscellaneous <br />TS <br />Tube Steel <br />EOS <br />Edge of Slab <br />MPH <br />Miles Per Hour <br />TYP <br />Typical <br />EQ <br />Equal <br />MR <br />Moisture Resistant <br />UL <br />Underwriters Laboratory <br />EQUIV <br />Equivalent <br />MTD <br />Mounted <br />UNO <br />Unless Noted Otherwise <br />EWC <br />Electric Water Cooler <br />MTL <br />Metal <br />VC <br />Vinyl Covered <br />EXP <br />Expansion <br />NUM/# <br />Number <br />VCT <br />Vinyl Composite Tile <br />EXT <br />Exterior <br />NOM <br />Nominal <br />VER <br />Verify <br />EXTG <br />Existing <br />NRC <br />Noise Reduction Class <br />VERT <br />Vertical <br />FACP <br />Fire Alarm Control Panel <br />NTS <br />Not To Scale <br />VIF <br />Verify In Field <br />FB <br />Fire Blocking <br />OC <br />On Center <br />VLT <br />Vault <br />FBC <br />Florida Building Code <br />OCC <br />Occupancy / Occupant <br />VWC <br />Vinyl Wail Covering <br />FD <br />Floor Drain <br />OFW <br />Outside Face of Wall <br />W <br />Washer <br />FE <br />Finish Elevation <br />OSB <br />Oriented Strand Board <br />W/ <br />With <br />FF <br />Finished Floor <br />PAN <br />Pantry <br />W/D <br />Washer/Dryer Combination <br />FIN <br />Finish(ed) <br />PKG <br />Package <br />W/o <br />Without <br />FJS <br />Finger Jointed Studs <br />PLAM <br />Plastic Laminate <br />WC <br />Water Closet <br />FLR <br />Floor <br />PLB <br />Plumb <br />WD <br />Wood <br />FM <br />Field Measure <br />PLMG <br />Plumbing <br />WDW <br />Window <br />FOM <br />Face of Masonry / Concrete <br />PLF <br />Pounds Per Linear Foot <br />WIC <br />Walk In Closet <br />FP <br />Fire Protection <br />PLYWD <br />Plywood <br />WH <br />Water Heater <br />1. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />PROCEEDING WITH THE WORK. <br />2. DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION <br />OF BUILDING COMPONENTS. DRAWINGS WORK IN CONJUNCTION WITH SPECIFICATIONS, PRODUCT <br />MANUFACTURER'S RECOMMENDATIONS, AND INDUSTRY STANDARDS REGARDING EXACT REQUIREMENTS OF <br />PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND CLASSIFICATIONS. <br />3. ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS AND SHALL COORDINATE AND SEQUENCE THEIR <br />WORK WITH OTHER TRADES, DO NOT BASE SCOPE OF WORK SOLELY ON A REVIEW OF THE SHEETS <br />TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />4. DO NOT SCALE DRAWINGS. USE ONLY PRINTED DIMENSIONS. <br />5. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING AND <br />PROPOSED TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES <br />PRIOR TO PROCEEDING WITH THE PROJECT. <br />6. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND <br />PROGRAMS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PROPER INSTALLATION AND APPLICATION <br />OF ALL MATERIALS AND PRODUCTS AS REQUIRED PER THE MANUFACTURER'S WRITTEN REQUIREMENTS, <br />QUALITY CONTROL, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />7. DIMENSIONS SHOWN ARE TO FACE OF THE SPECIFIED BUILDING MATERIAL; (CONCRETE, CMU, WOOD/METAL <br />STUD, ETC.), AND TO CENTERLINE OF OPENINGS, UNO. <br />8. IF REQUIRED BY THE AHJ, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND SUBMITTING <br />PRODUCT APPROVAL DOCUMENTATION TO THE AHJ IN THE FORM REQUIRED BY THE AHJ. THE CONTRACTOR <br />MUST FIRST SUBMIT THE PRODUCT DOCUMENTATION TO THE ARCHITECT FOR REVIEW AND APPROVAL <br />BEFORE SUBMITTING TO THE AHJ. <br />9. ANY ERRORS, OMISSIONS OR INCONSISTENCIES DISCOVERED IN THE DOCUMENTS, OR ANY VARIATION OR <br />AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR <br />REQUIREMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF A DISCREPANCY IS FOUND IN <br />THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING. <br />10. ANY ON SITE OBSERVATIONS BY THE ARCHITECT SHALL BE IN THE FORM OF RANDOM OBSERVATIONS ONLY <br />AND DO NOT RELIEVE THE CONTRACTOR FROM HIS RESPONSIBILITY OF BUILDING ACCORDING TO THE <br />APPROVED CONSTRUCTION DOCUMENTS, IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS, AND <br />AS REQUIRED BY THE AHJ. <br />11. ALL MATERIALS IN DIRECT CONTACT WITH OTHER MATERIALS SHALL BE COMPATIBLE AND COMPLY WITH THE <br />MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />12. ALL MATERIALS AND PRODUCTS INDICATED ON THE DRAWINGS SHALL BE AS SPECIFIED, UNO. SEE PROJECT <br />MANUAL SPECIFICATIONS. <br />13. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND INSTALL AN IDENTIFYING SYMBOL ON <br />STRUCTURES CONSTRUCTED WITH A LIGHT -FRAME TRUSS COMPONENT IN A MANNER SUFFICIENT TO COMPLY <br />WITH THE STATE OF FLORIDA FIRE MARSHAL'S OFFICE IN ACCORDANCE WITH FLORIDA STATUTE 633.027, PER <br />THE REQUIREMENTS OF THE FLORIDA ADMINISTRATIVE CODE RULE 69A-60.0081, AND AS DETERMINED BY THE <br />AHJ. <br />SITE WORK & FOUNDATION <br />1. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR ACTUAL VALUE AS SPECIFIED <br />BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS AND SLABS ARE DESIGNED <br />TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE SOILS. A CERTIFIED SOILS <br />ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE WITH SUBSURFACE SOIL <br />INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE <br />ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR REVISED DESIGNS. <br />2. THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE <br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED <br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY <br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL <br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. <br />3. REFER TO CIVIL ENGINEER'S SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, <br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, AND ALL INFORMATION RELATED TO THE PROJECTS ON -SITE <br />DEVELOPMENT AND OFF -SITE REQUIREMENTS, IF APPLICABLE. <br />4. REFER TO LANDSCAPE ARCHITECTS AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, <br />ETC. <br />SHEET INDEX <br />0 ARCHITECTURAL SHEETS Zephyr <br />A20.01 Sheet Index, Code Compliance & General Notes <br />A2.01 Architectural Site Plan <br />Commons <br />STRUCTURAL SHEETS <br />S20.30 General Structural Notes Maintenance & Trash <br />S20.31 Foundation & Roof Framing Plans <br />S20.32 Structural Sections & Details Compactor <br />S20.33 Structural Sections & Details <br />S20.34 Structural Sections & Details City of Zephyrhills, FL <br />S20.35 Structural Sections & Details <br />S20.36 Structural Sections & Details <br />ARCHITECTURAL SHEETS <br />A20.21 Plans & Elevations <br />A20.22 Section Details <br />0 PLUMBING SHEETS <br />P14.00 Apartments Symbols, Abbreviations & General Notes - Plumbing <br />P14.01 Site Plan - Plumbing <br />P20.41 Floor Plan - Plumbing <br />MECHANICAL SHEETS PROJECT INFORMATION <br />M15.00 Apartments Symbols, Abbreviations & General Notes - Mech DESCRIPTION: Proposed new Maintenance Building and Trash <br />M15.01 Site Plan - Mechanical Compactor Enclosure <br />M20.42 Floor Plan - Mechanical LOCATION: NE of Gall Blvd & Pretty Pond Rd I Zephyrhills, FL <br />M20.42A Energy Calculations - Mechanical <br />ELECTRICAL SHEETS PROJECT TEAM <br />E16.00 Apartments Symbols, Abbreviations & General Notes - Electrical <br />E16.01 Site Plan - Electrical OWNER: SF Zephyr Commons Outparcels, LP <br />E20.43 Floor Plan - Electrical 400 Clematis Street, Suite 201 1 West Palm Beach, FL 33401 <br />678.977.3362 1 taddison@nadg.com <br />CODE COMPLIANCE: MAINT. BLDG & TRASH COMPACTOR <br />OCCUPANCY TYPE UTILITY (GROUP U) <br />CONSTRUCTION TYPE TYPE V-B <br />FIRE SPRINKLER NONSPRINKLERED <br />AREA & HEIGHT LIMITATION ALLOWED PROPOSED <br />MAX HEIGHT (FBC-B 504.3) 40'-0" 15'-0" <br />MAX NUMBER OF STORIES (FBC-B 504.4) 1 STORY 1 STORY <br />MAXIMUM AREA PER FLOOR (FBC-B 506.2) 5,500 S.F. 880 S.F. LLC. <br />U. CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL MEP ENGINEERS: Joseph, Lawrence, Q. Co, <br />NOT BE LESS THAN 61NCHES, UNO. 1180 Hardwood Ave, Suite 3000 1 Altamonte Springs, FL 32714 <br />BUILDING AREA TABLE: MAINT. BLDG &TRASH COMPACTOR 321.972.4466 � adam.barney@jlceng.com <br />� WEATHERNVATER INTRUSION PREVENTION <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER INSTALLATION OF ALL MATERIALS REQUIRED TO <br />PREVENT WATER INTRUSION, INCLUDING BUT NOT LIMITED TO; FLASHINGS, WEATHERIWATER-RESISTIVE <br />BARRIERS (BUILDING WRAP), SELF -ADHERING MEMBRANES, AND SEALANTS AS INDICATED ON THE DRAWINGS <br />OR AS OTHERWISE REQUIRED IF NOT INDICATED. <br />2. ALL PENETRATIONS THROUGH THE EXTERIOR CLADDING SYSTEM SHALL BE PROPERLY SEALED. <br />DECAY & TERMITE PROTECTION <br />1. ALL BUILDINGS SHALL HAVE TERMITE PROTECTION AGAINST SUBTERRANEAN TERMITES, INCLUDING SOIL <br />APPLIED PESTICIDES, BAIT SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF <br />TERMITE PROTECTION LABELED FOR USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION TO COMPLY <br />WITH APPLICABLE BUILDING CODE AND THE AHJ. <br />2. THE CONTRACTOR SHALL PROVIDE TERMITE PROTECTION AS REQUIRED BY ALL APPLICABLE CODES. TERMITE <br />PROTECTION SHALL BE INSTALLED BY A LICENSED PEST CONTROL COMPANY PER THE TERMITICIDE <br />MANUFACTURER'S RECOMMENDATIONS AND IN ACCORDANCE WITH APPLICABLE RULES AND LAWS <br />ESTABLISHED BY THE STATE. <br />3. THE TERMITE PROTECTION SHALL BE PROVIDED BY USING REGISTERED TERMITICIDES. THE TREATMENT <br />SHALL COMPLY WITH APPLICABLE RULES AND LAWS ESTABLISHED BY THE STATE, <br />4. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED AND POSTED AS REQUIRED BY CODE OR BY THE <br />AHJ. IF REQUIRED BY THE AHJ, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE AHJ BY A LICENSED <br />PEST CONTROL COMPANY, <br />5. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM BUILDING SIDEWALLS, <br />UNO. <br />6. ALL WOOD FRAMING MEMBER AND FURRING STRIPS IN CONTACT WITH OR ATTACHED DIRECTLY TO MASONRY <br />OR CONCRETE SHALL BE OF APPROVED PRESERVATIVE TREATED (PT) WOOD AND ALL FASTENERS AND <br />ANCHORS TO BE COMPATIBLE. <br />7. PROVIDE CODE REQUIRED CLEARANCE AT EXTERIOR WALL BETWEEN WALL COVERING AND FINAL GRADE FOR <br />TERMITE INSPECTION. <br />FIRE EXTINGUISHERS <br />1. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH BUILDING AS REQUIRED AND SPECIFIED IN <br />NFPA 10, PORTABLE FIRE EXTINGUISHER SHALL BE INSTALLED IN LOCATIONS INDICATED ON THE DRAWINGS <br />OR MINIMUM OF (1) FIRE EXTINGUISHER PER BREEZEWAY, CORRIDOR, GENERAL BUILDING AREA, OR AS <br />OTHERWISE REQUIRED BY THE AHJ. FIRE EXTINGUISHERS SHALL BE LOCATED (1) PER FLOOR, WITH A <br />MAXIMUM TRAVEL DISTANCE OF 75 FEET TO THE EXTINGUISHER OR AS REQUIRED BY THE AHJ. EACH <br />EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, UNO. <br />2. WHERE REQUIRED OR AS INDICATED ON THE DRAWINGS, PROVIDE PORTABLE FIRE EXTINGUISHERS IN EACH <br />INDIVIDUAL RESIDENTIAL DWELLING UNIT AS RECOMMENDED BY NFPA 10 AND INSTALLED AS INDICATED ON <br />THE DRAWINGS OR AT A MINIMUM OF (1) FIRE EXTINGUISHER PER FLOOR LEVEL OF A LIVING UNIT WITH A <br />MAXIMUM TRAVEL DISTANCE OF 40 FEET TO THE EXTINGUISHER OR AS REQUIRED BY LOCAL AHJ. EACH <br />EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, UNO. <br />3. WHERE APPLICABLE, COMMERCIAL KITCHEN AREAS (INCLUDING OUTDOOR KITCHEN AREAS) SHALL BE <br />PROVIDED WITH WET CHEMICAL TYPE, CLASS K FIRE EXTINGUISHERS PER NFPA-10, SIZE AS REQUIRED BY THE <br />AHJ. <br />BUILDING TYPE <br />MAINTENANCE BUILDING & TRASH COMPACTOR ENCLOSURE <br />A/C <br />NON -A/C <br />GROSS <br />BUILDING TOTAL <br />293 <br />587 <br />880 <br />SYMBOLS LEGEND <br />q CENTERLINE OF BUILDING/OBJECT <br />UD OO NUMBERED DOOR SYMBOLS <br />ho'.0/1- ELEVATION TARGET, INDICATES HGT AFF <br />a% KEY NOTE WITH LEADER INDICATOR <br />QREVISION DELTA <br />TITLE MARKER <br />O LETTERED WINDOW SYMBOL <br />COMPLETE SECTION: <br />X DETAIL NUMBER <br />LOCATION & DIRECTION OF CUT <br />NOTE <br />' •XX SHEET ON WHICH DETAIL APPEARS <br />PARTIAL SECTION: <br />X DETAIL NUMBER <br />LOCATION & DIRECTION OF CUT <br />NOTE <br />AX•XX SHEET ON WHICH DETAIL APPEARS <br />A ELEVATION: <br />x DETAIL NUMBER <br />DETAIL DIVISION <br />' SHEET ON WHICH DETAIL APPEARS <br />ASSEMBLY TAG: <br />WALL DESIGNATION <br />ARCHITECT: Forum Architecture & Interior Design <br />237 S. Westmonte Drive, Suite 220 1 Altamonte Springs, FL 32714 <br />407.830.1400 1 kmcintyre@forumarchitecture.com <br />STRUCTURAL ENGINEERS: Structural Concepts & Design, LLC <br />2965 West State Road 434, Suite 100 1 Longwood, FL 32779 <br />407.682.2086 1 cscroggins@scd-eng.com <br />+LL WORK SHALL COMPLY WITH PREVAILING <br />CODE: FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />REVIEW DATE: 2 <br />CITY OF ZEPHYRHILLS <br />BUILDING OFFICIAL <br />ISSUE HISTORY <br />02/17/22 Permit Set <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />02/17/2022 <br />Karen V McIntyre <br />A r%^AA -fAA n <br />i <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Title Sheet, Drawing <br />Index & Issue History <br />r <br />A20.01 <br />