Laserfiche WebLink
ABBREVIATIONS <br />GENERAL NOTES <br />LEGEND <br />ABV <br />ABOVE <br />HWR <br />HOT WATER RETURN <br />1. <br />INSTALL EQUIPMENT AND MATERIALS IN COMPLIANCE WITH MANUFACTURER'S MINIMUM CLEARANCE REQUIREMENTS AND <br />SUPPLY DIFFUSER (4-WAY) <br />0 <br />REFERENCE NOTES <br />ADJ <br />ADJUSTABLE <br />HWS <br />HOT WATER SUPPLY <br />RECOMMENDATIONS. <br />AF <br />AIRFOIL <br />HVAC <br />HEATING VENTILATION AND AIR CONDITIONING <br />2. <br />COMPLY WITH THE LATEST EDITIONS OF NFPA AND THE LATEST ADOPTED EDITION FLORIDA BUILDING CODE (MECHANICAL, <br />RETURN OR OUTDOOR AIR GRILLE <br />0 <br />REFERENCE NOTE - MULTI -DISCIPLINE SHEETS <br />AFF <br />ABOVE FINISHED FLOOR <br />HV <br />HEATING AND VENTILATING <br />PLUMBING, GAS AND ENERGY CONSERVATION). <br />AC <br />AIR CONDITIONER <br />IN.WG <br />INCHES WATER GAUGE <br />3. <br />ALL MATERIALS SHALL FIT THE SPACE AVAILABLE. VERIFY DIMENSIONS AND CLEARANCES ON BUILDING PLANS PRIOR TO <br />� <br />EXHAUST GRILLE <br />FLOW DIRECTION <br />ACU <br />AIR CONDITIONING UNIT <br />KW <br />KILOWATTS <br />COMMENCING WORK. <br />IUI <br />INDICATES POINT OF CONNECTION BETWEEN NEW <br />AHU <br />AIR HANDLING UNIT <br />L.AT <br />LEAVING DIFFUSER <br />4. <br />AN INDEPENDENT TEST AND BALANCE CONTRACTOR (TABC) SHALL BE HIRED BY THE GENERAL. CONTRACTOR. <br />AND EXISTING <br />AP <br />ACCESS PANEL <br />LD <br />LINEAR DIFFUSER <br />SUPPLY DUCT UP SECTION (RECTANGULAR) <br />C <br />POINT OF DISCONNECT <br />5. <br />TABC IS RESPONSIBLE FOR TESTING AND BALANCING OF AIR SYSTEMS IN ACCORDANCE WITH AABC GUIDELINES. A TEST AND <br />BAS <br />BUILDING AUTOMATION SYSTEM <br />LWT <br />LEAVING WATER TEMPERATURE <br />BALANCE REPORT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL. <br />BI <br />BACKWARD INCLINE <br />MAX <br />MAXIMUM <br />6. <br />PROVIDE 45 DEGREE BRANCH TAKE -OFF PER SMACNA FIG. 2-8 ON ALL RECTANGULAR DUCT TAKE -OFFS. <br />RETURN DUCT UP SECTION (RECTANGULAR) <br />CWS <br />CONDENSER WATER SUPPLY PIPING <br />BLDG <br />BUILDING <br />MBH <br />1000 X BTUH <br />BHP <br />BRAKE HORSEPOWER <br />MIN <br />MINIMUM <br />7. <br />ALL DUCTWORK TAKE -OFFS AND/OR BRANCH DUCTWORK SHALL BE PROVIDED WITH BALANCING DAMPERS (REMOTE IF IN <br />CWR <br />CONDENSER WATER RETURN PIPING <br />HARD CEILING AREAS). <br />BTUH <br />BRITISH THERMAL UNIT PER HOUR <br />MD <br />MANUAL VOLUME DAMPER <br />EXHAUST DUCT UP SECTION (RECTANGULAR) <br />BDD <br />BACKDRAFT DAMPER <br />M <br />MOTORIZED DAMPER <br />8. <br />PROVIDE AND INSTALL DUCT MOUNTED HINGED ACCESS DOORS FOR ALL SMOKE AND/OR FIRE DAMPERS, NOT OTHERWISE <br />BCWS <br />BUILDING CONDENSER WATER SUPPLY PIPING <br />ACCESSIBLE. <br />CD <br />CONDENSATE DRAIN <br />MZ <br />MULTI -ZONE <br />i �x` <br />SUPPLY DUCT DOWN SECTION (RECTANGULAR) <br />CFM <br />CUBIC FEET PER MINUTE <br />N.T.S. <br />NOT TO SCALE <br />9. <br />CONTRACTOR SHAH COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR <br />BCWR <br />BUILDING CONDENSER WATER RETURN PIPING <br />PRIOR TO ORDERING AND SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO OR INSTALLING EQUIPMENT AND MATERIALS. <br />CLG <br />CEILING <br />OA <br />OUTSIDE AIR <br />CHIN <br />CHILLED WATER <br />OBMVD <br />OPPOSED BLADE MANUAL VOLUME DAMPER <br />10. <br />COORDINATE ALL HVAC SYSTEM DRAWINGS WITH EXISTING/NEW TRUSS TO AVOID INTERFERENCE BETWEEN MECHANICAL <br />i \� � <br />RETURN DUCT DOWN SECTION (RECTANGULAR) <br />CHINS <br />CHILLED WATER SUPPLY PIPING <br />SYSTEMS AND ROOF STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH TRUSS <br />CHWR <br />CHILLED WATER RETURN <br />OPD <br />OPEN DRIP PROOF <br />INTERFERENCE THAT OCCURS IN THE FIELD DURING CONSTRUCTION. COORDINATE IN ADVANCE. DUCT SIZES MAY BE <br />CHWS <br />CHILLED WATER SUPPLY <br />PROP <br />PROPELLER <br />REVISED TO FIT TRUSS SYSTEM SO LONG AS THE EQUIVALENT INSIDE CROSS SECTIONAL AREA IS NOT DECREASED. <br />i <br />EXHAUST DUCT DOWN SECTION (RECTANGULAR) <br />CHWR <br />CHILLED WATER RETURN PIPING <br />CWR <br />CONDENSER WATER RETURN <br />PCR <br />PRE -CONDITIONED AIR SYSTEM RETURN WATER <br />11. <br />GAUGES AND CONSTRUCTION FOR DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA'S HVAC DUCT <br />CWS <br />CONDENSER WATER SUPPLY <br />PCs <br />PERCENT <br />CONSTRUCTION STANDARDS. <br />HWS <br />HEATING WATER SUPPLY PIPING <br />CONC <br />CONCRETE <br />PD <br />PRESSURE DROP <br />12. <br />TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN TOP OF DUCTWORK LEVEL AND HIGH AS POSSIBLE. <br />SUPPLY DUCT UP SECTION (ROUND) <br />CONE <br />CONDENSATE <br />PERF. PL. <br />PERFORATED PLATE <br />FLEXIBLE DUCT RUN -OUTS TO CEILING DIFFUSERS SHALL BE AS STRAIGHT AS POSSIBLE AND FREE OF SAGS AND KINKS. <br />HWR <br />HEATING WATER RETURN PIPING <br />FLEX DUCT SHALL BE THE SAME SIZE AS THE DIFFUSER NECK IT SERVES. <br />CONT <br />CONTINUOUS <br />PL.BG <br />PLUMBING <br />i <br />SUPPLY DUCT DOWN SECTION (ROUND) <br />CO <br />CARBON MONOXIDE <br />PSIA <br />POUNDS PER SQUARE INCH ABSOLUTE <br />13. <br />ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH SQUARE TO ROUND TRANSITIONS. SPIN -IN FITTINGS AT <br />_CD <br />CONDENSATE DRAIN PIPING <br />THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. <br />COP <br />COEFFICIENT OF PERFORMANCE <br />PSIG <br />POUNDS PER SQUARE INCH GAUGE <br />14. <br />THE CONTRACTOR SHALL FULFILL ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SHALL COMPLETE THE WORK <br />LINEAR SLOT DIFFUSER <br />R <br />REFRIGERANT PIPING <br />CU <br />CONDENSING UNIT <br />RA <br />RETURN AIR <br />SHOWN ON THESE DRAWINGS. ALL SYSTEMS SHALL BE FINISHED, TESTED AND BALANCED, ADJUSTED, AND PROVEN TO BE <br />DB <br />DRYBULB <br />RD <br />RADIATION DAMPER <br />FULLY OPERATIONAL AND USEABLE. <br />�FLOW <br />EXISTING LINEAR SLOT DIFFUSER (LIGHT LINETYPE) <br />y <br />SENSOR <br />DWDI <br />DOUBLE WIDTH, DOUBLE INLET <br />REG <br />REGISTER <br />15. <br />ADJUST ALL DIFFUSERS IN CORRIDORS OR WITHIN THREE (3) FEET OF A WALL TO PROVIDE 2-WAY OR 3-WAY BLOW AWAY <br />-� <br />DWGS <br />DRAWINGS <br />REQ'D <br />REQUIRED <br />FROM OR PARALLEL TO WALLS. ALL DIFFUSERS SHALL HAVE 4-WAY BLOW UNLESS NOTED OTHERWISE. <br />RECTANGULAR DUCTWORK WITH TAKE -OFF, BALANCING <br />DX <br />DIRECT EXPANSION <br />RG <br />RETURN AIR GRILLE <br />16. <br />PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. <br />A B <br />DAMPER AND INSULATED FLEXIBLE ROUND DUCT. SAME <br />SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. <br />SP <br />STATIC PRESSURE TRANSMITTER ASSEMBLY <br />EF <br />EXHAUST FAN <br />RH <br />RELATIVE HUMIDITY <br />17. <br />ALL DAMPERS IN AND ABOVE CEILING SHALL BE ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL ACCESS PANELS IN <br />FIRST DIMENSION IS THAT OF SIDE SHOWN <br />EXH <br />EXHAUST <br />RPM <br />REVOLUTIONS PER MINUTE <br />CEILINGS OR WALLS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR DRAWINGS FOR PROPER LOCATION. <br />A 0 <br />ROUND DUCTWORK <br />EA <br />EAT <br />EACH <br />ENTERING AIR TEMPERATURE <br />RR <br />RTU <br />RETURN AIR REGISTER <br />ROOFTOP UNIT <br />18. <br />MOUNT THERMOSTATS WHERE INDICATED ON PLANS 48' ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. IN HANDICAPPED <br />ACCESSIBLE AREAS, MOUNT CONTROLS AT 48" (MAXIMUM) ABOVE FINISHED FLOOR. <br />CONICAL FITTING WITH DAMPER ON BRANCH <br />CONNECTION TO RECTANGULAR MAIN <br />L <br />L-t/4w,Vw <br />RECTANGULAR BRANCH DUCT CONNECTION. <br />(PROVIDE BALANCING DAMPER AT ALL <br />(PROVIDE DAMPER. IN LOW PRESSURE DUCTWORK ONLY) <br />MN• 4' <br />BRANCH CONNECTIONS) <br />EER <br />ENERGY EFFICIENCY RATIO <br />SA <br />SUPPLY AIR <br />19. <br />COORDINATE DUCTWORK AND PIPING WITH PLUMBING, FIRE PROTECTION AND ELECTRICAL. MAKE OFFSETS AND TRANSITIONS <br />ELECT <br />ELECTRICAL <br />SF <br />SUPPLY FAN <br />TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE CONTRACT. <br />EXISTING DUCTWORK TO REMAIN (LIGHT LINETYPE) <br />ENT <br />ENTERING <br />SD <br />SMOKE DETECTOR <br />20. <br />SEAL ALL TRANSVERSE JOINTS AND FITTINGS WITH DUCT SEALER. <br />- <br />TEE (PLAN, UP, DOWN) <br />EQ <br />EQUAL <br />SDMP <br />SMOKE DAMPER <br />ER <br />EXHAUST REGISTER <br />SDMP <br />SQUARE FOOT <br />21. <br />TRAP AND ROUTE CONDENSATE DRAINS LINES, FULL SIZE OF UNIT CONNECTION, AS INDICATED. SLOPE 1/8" PER FOOT. <br />-i► R <br />DUCT OFFSETS UP (RISE) IN DIRECTION INDICATED <br />-0 <br />ELBOW (PLAN, UP, DOWN) <br />EWT <br />ENTERING WATER TEMPERATURE <br />SR <br />SUPPLY REGISTER <br />22. <br />ALTERNATE MANUFACTURERS AND MODELS WILL BE REVIEWED. THERE MAY BE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL <br />FC <br />FORWARD CURVED <br />STR <br />STARTER <br />CHANGES RESULTING FROM THE ALTERNATES. THE COST OF IMPLEMENTING AND ENGINEERING THESE CHANGES SHALL BE <br />-+-D <br />DUCT OFFSETS DOWN (DROP) IN DIRECTION INDICATED <br />BORNE BY THE MECHANICAL SUBCONTRACTOR. <br />VALVE <br />FCU <br />FAN COIL UNIT <br />SWSI <br />SINGLE WIDTH, SINGLE INLET <br />23. <br />PIPE AND DUCT ROUTING SHOWN IS SCHEMATIC. PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS, INCLUDING DIVIDED <br />FD <br />FIRE DAMPER <br />SZ <br />SINGLE ZONE <br />DUCTS, REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES AS ENCOUNTERED IN THE FIELD. <br />OPPOSED BLADE VOLUME DAMPER (OBD) <br />FL <br />FLOOR <br />TEFC <br />TOTALLY ENCLOSED FAN COOLED <br />TWO WAY MOTORIZED CONTROL VALVE <br />24. <br />COORDINATE CEILING MOUNTED AIR DEVICE LOCATION WITH REFLECTED CEILING PLAN AND OTHER <br />FLEX <br />FLEXIBLE CONNECTOR OR DUCT <br />TEMP <br />TEMPERATURE <br />.TRADES. <br />FPM <br />FEEL PER MINUTE <br />TG <br />TRANSFER GRILLE <br />25. <br />ALL CONTROL WIRING AND .CONDUIT SHALL COMPLY WITH NEC DIVISION 16 SPECIFICATIONS. <br />MANUAL DAMPER <br />THREE WAY MOTORIZED CONTROL VALVE <br />F/S <br />COMBINATION FIRE AND SMOKE DAMPER <br />T/O <br />TRANSFER OPENING ABOVE CEILING <br />26. <br />PROVIDE MATERIALS WHICH HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR <br />FT. H2O <br />FEET WATER GAUGE <br />LESS WHEN TESTED IN ACCORD WITH ASTM E84. <br />IIIII <br />FLEXIBLE DUCT CONNECTION <br />- -- <br />PRESSURE REDUCING VALVE <br />T'STAT <br />THERMOSTAT <br />F <br />DEGREES FAHRENHEIT <br />TYP <br />TYPICAL <br />27. <br />SLEEVE AND FIRE STOP PENETRATIONS THROUGH FIRE RATED SYSTEMS TO MAINTAIN RATING OF SYSTEM. USE MINIMUM <br />STEEL GAUGE DUCT AS REQUIRED TO MAINTAIN RATING OF SYSTEM. <br />FLOW CONTROL <br />GALVANIZED <br />VALVE <br />GA <br />GAUGE <br />VFDC <br />VARIABLE FREQUENCY DRIVE <br />FIRE/RADIATION DAMPER WITH ACCESS PANEL <br />GAL <br />GALLON <br />YAV <br />VARIABLE AIR VOLUME <br />28. <br />WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE DUCT <br />TAG SHALL LOCATED WITHIN 6 FEET OF THE <br />BALL VALVE FOR PIPING 2-INCHES AND SMALLER, <br />BUTTERFLY VALVE FOR PIPING 2-1/2 INCHES AND <br />SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR BE <br />--I��- <br />GALV <br />GALVANIZED <br />Vs <br />VARIABLE SPEED <br />EXHAUST DUCT CONNECTION. <br />COMBINATION FIRE/SMOKE DAMPER WITH ACCESS PANEL <br />LARGER <br />GPM <br />GALLONS PER MINUTE <br />W <br />WATTS <br />29. <br />CONTRACTOR TO ORDER ALL FIRE/SMOKE DAMPERS WITH INTEGRAL SMOKE DETECTORS AND END STOP INDICATOR OPTIONS. <br />BUTTERFLY VALVE <br />HP <br />HTWR <br />HORSEPOWER <br />HIGH TEMPERATURE HOT WATER RETURN <br />W/ <br />WITH <br />VERIFY VOLTAGE WITH ELECTRICAL DRAWINGS. IF BUILDING IS EQUIPPED WITH FIRE ALARM SYSTEM ALL FIRE/SMOKE <br />DAMPERS WILL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM. <br />EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) <br />-��I-- <br />W/0 <br />WITHOUT <br />- - - <br />CHECK VALVE <br />HTWS <br />HIGH TEMPERATURE HOT WATER SUPPLY <br />30. <br />ALL MECHANICAL EQUIPMENT SHALL BE THOROUGHLY CLEANED OF ALL DIRT, OIL, CONCRETE, ETC. ANY DENTS, SCRATCHES <br />DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY <br />HW <br />HOT WATER <br />WB <br />WETBULB <br />OR OTHER VISIBLE BLEMISHES SHALL BE CORRECTED AND THE APPEARANCE OF THE EQUIPMENT MADE "LIKE NEW" AND TO <br />ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY <br />ZD <br />ZONE DAMPER <br />THE SATISFACTION OF THE ARCHITECT/ENGINEER. UPON COMPLETION, AND BEFORE FINAL ACCEPTANCE OF THE WORK, ALL <br />MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR <br />STRAINER <br />DEBRIS, RUBBISH, LEFTOVER MATERIALS, TOOLS AND EQUIPMENT SHALL BE REMOVED FROM THE SITE. PROTECTION OF WORK <br />CONTROL REQUIREMENTS. <br />UNTIL FINAL ACCEPTANCE: PROTECT ALL MATERIALS AND EQUIPMENT FROM DAMAGE, ENTRANCE OF DIRT AND CONSTRUCTION <br />BALANCE VALVE WITH INTEGRAL TAPS FOR CONNECTION <br />DEBRIS FROM THE TIME OF INSTALLATION UNTIL FINAL ACCEPTANCE. ANY MATERIALS AND EQUIPMENT WHICH ARE DAMAGED <br />A-1 <br />AIR DEVICE TAG <br />OF DIFFERENTIAL PRESSURE METER. VALVE SHALL <br />SHALL BE REPAIRED TO "AS NEW" CONDITION OR REPLACED AT THE DIRECTION OF THE ARCHITECT/ENGINEER. WHERE <br />MARK-C <br />HAVE NAMEPLATE INDICATING WATER FLOW RATE VERSUS <br />FACTORY FINISHES OCCUR AND DAMAGE IS MINOR, FINISHES MAY BE TOUCHED UP. IF, IN THE OPINION OF THE <br />VALVE PRESSURE DROP <br />ARCHITECT/ENGINEER THE DAMAGE IS EXCESSIVE, FACTORY FINISH SHALL BE REPLACED TO "NEW" CONDITION. <br />SIDEWALL TRANSFER GRILLE <br />A <br />AUTOMATIC FLOW CONTROL VALVE WITH INTEGRAL <br />31. <br />DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT AND EXTENT OF WORK. EXACT LOCATIONS AND <br />TEMPERATURE AND PRESSURE TEST PORTS <br />ARRANGEMENT OF MATERIALS AND EQUIPMENT SHALL BE DETERMINED, WITH THE ACCEPTANCE OF THE ARCHTTECT/ENGINEER, <br />AS WORK PROGRESSES TO CONFORM IN THE BEST POSSIBLE MANNER WITH THE SURROUNDINGS AND WITH THE ADJOINING <br />WORK OF OTHER TRADES. WHERE LOCATIONS OF EQUIPMENT, DEVICES OR FIXTURES ARE CONTROLLED BY ARCHITECTURAL <br />SIDEWALL SUPPLY REGISTER <br />UNION <br />FEATURES, ESTABLISH SUCH LOCATIONS BY REFERRING TO DIMENSIONS ON ARCHITECTURAL DRAWINGS AND NOT BY SCALING <br />DRAWINGS. <br />32. <br />IN CASE OF DIFFERENCES BETWEEN DRAWINGS AND SPECIFICATIONS, OR WHERE DRAWINGS AND SPECIFICATIONS ARE NOT <br />SIDEWALL RETURN GRILLE OR OUTSIDE AIR LOWER <br />VENTURI FLOW METER <br />CLEAR OR DEFINITE, THE SUBJECT SHALL BE REFERRED TO ARCHITECT/ENGINEER FOR CLARIFICATION AND INSTRUCTIONS. <br />PRESSURE AND/OR TEMPERATURE PORT <br />33. <br />ANY INTERRUPTION OF EXISTING MECHANICAL AND ELECTRICAL SERVICES SHALL BE COORDINATED IN ADVANCE WITH THE <br />OWNER'S REPRESENTATIVE. THIS INCLUDES, BUT IS NOT LIMITED TO, SERVICES PROVIDING CHILLED WATER, Ell ECTRICITY, OR <br />SIDEWALL EXHAUST GRILLE <br />OTHER CRITICAL SYSTEMS AS MAY BE PERTINENT TO THIS PARTICULAR PROJECT. SERVICE INTERRUPTION TIMES AND <br />THERMOMETER <br />DURATION OF INTERRUPTION OF SERVICES SHALL BE DECIDED BY THE OWNER. PROVIDE APPROPRIATE PROVISIONS (SUCH AS <br />WALL MOUNTED DDC TEMPERATURE SENSOR <br />ISOLATION SHUT-OFF VALVES, DAMPERS, END CAPS, AND SIMILAR ITEMS) AS NECESSARY TO ACCOMMODATE THE REQUIRED <br />MOUNT 4'-0" ABOVE FINISHED FLOOR <br />SERVICE INTERRUPTIONS. IF SHUTDOWNS CANNOT BE ACCOMMODATED, PROVIDE MEANS FOR "WET" TAPPING OR "HOT" <br />PRESSURE GAUGE WITH GAUGE COCK <br />TAPPING OF PIPING SYSTEMS. <br />O <br />WALL MOUNTED THERMOSTAT <br />34. <br />ALL MAIN DUCTWORK SHOWN PER PLAN IS TO BE SHEET METAL OR DUCT BOARD. ALL DUCT BOARD INSTALLATIONS ARE TO <br />MOUNT 4'-0" ABOVE FINISHED FLOOR <br />FLEXIBLE CONNECTION <br />BE APPROVED BY BUILDING OWNER PRIOR TO MATERIAL PURCHASE. <br />© <br />WALL MOUNTED CO SENSOR <br />35. <br />FIRE & FIRE/SMOKE DAMPERS ARE REQUIRED TO BE UL LISTED AND APPROVED FOR THE ASSEMBLIES LISTED ON THE <br />MOUNT 4'-0" ABOVE FINISHED FLOOR <br />PRESSURE RELIEF VALVE <br />ARCHITECTURAL DRAWINGS. THESE DAMPERS MUST ALSO BE REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO <br />ORDERING. <br />H <br />O <br />WALL MOUNTED DDC HUMIDITY SENSOR <br />MOUNT 4'-0" ABOVE FINISHED FLOOR <br />OPENING IN WAIL ABOVE CEILING <br />Os <br />WAIL MOUNTED HUMIDISTAT SENSOR <br />VALUES <br />MOUNT 4'-0" ABOVE FINISHED FLOOR <br />ENERGY CALCULATION <br />A <br />PHOTO DETAIL OR SECTION IDENTIFICATION TARGET <br />� EQUIPMENT <br />3 TYPE <br />MARK <br />EQUIPMENT TAG <br />ROOF: R-30 <br />A = DETAIL NUMBER <br />WALLS: R-19 <br />NOTE: <br />B <br />B = SHEET NUMBER ON WHICH DETAIL IS LOCATED <br />1" DOOR UNDER CUT. ARROW <br />WINDOWS: <br />THIS PROJECT HAS MET THE MINIMUM ENERGY CODE REQUIREMENTS AND HAS <br />UC <br />INDICATES DIRECTION OF FLOW <br />SHGC: 25 <br />U VALUE: U-.4 <br />BEEN DESIGNED TO THE MINIMUM VALUES NOTED. ALL MATERIALS USED IN THE <br />CONSTRUCTION OF THIS PROJECT MUST MEET OR EXCEED THE MINIMUM VALUES <br />RD <br />RADIATION DAMPER INSTALLED IN AIR DEVICE <br />FLEX DUCT <br />VLT: .58 <br />NOTED PER THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE AND <br />DOORS: R-2.5 <br />FLORIDA ENERGY CODE. <br />RD <br />RADIATION DAMPER INSTALLED IN DUCT <br />Q (� <br />Joseph, LCIWPQnCe CJC 1�0 <br />FLOORS: <br />R-11 <br />NOTE. <br />SYMBOLS <br />SHOWN ON THIS MECHANICAL LEGEND ARE FOR Consulting Engineers <br />NOTE: <br />ELBOW WITH TURNING VANES REFERENCE PURPOSES ONLY. ALL <br />OF THESE SYMBOLS <br />GENERAL NOTES ON THIS MECHANICAL SHEET ARE FOR <br />MAY NOT <br />BE USED FOR THIS PROJECT. 1180 HARWOOD AVE., SUITE 3000 <br />ALTAMONTE SPRINGS, FLORIDA 32714 <br />GENERAL REFERENCE PURPOSES ONLY. ALL OF THESE <br />TEL: 321.972.4466 <br />NOTES MAY NOT BE USED FOR THIS PROJECT. <br />WWW.JLCENG.COM <br />CA NO. 28730 <br />M <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AA0002731 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />JLC21.0058.00 <br />Adam Joseph Barney <br />P.E. #: 69124 <br />SET DISTRIBUTIONS: <br />Z�, SHEET REVISIONS: <br />EDITED BY: SMB/AJB <br />N <br />PROJECT NO. <br />4097 <br />Apartments <br />Symbols, Abbreviations, <br />and General Notes - <br />Mechanical <br />M15.00 <br />